INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING

Similar documents
ASX7-4-IOM-7 J

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS

AZB 800. Vertical Flue Gas Ducting Ø60/100mm

Flue Installation. High Efficiency Condensing Boilers

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

GREENSTAR 60/100 HORIZONTAL FLUE

NAVIEN AMERICA INC FITCH AVENUE

Flue Options. Ace Finest Finest Gold Best 30/40/50/60 Best 80. Flue Options Flue Options Flue Options Flue Options

Your safety and the safety of others are very important.

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

DRYER VENTING SPECIFICATIONS DRYER SAFETY

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Twin Pipe PVC / CPVC Venting options for Rinnai Ultra Series Condensing Tankless Water Heaters.

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

3 IN 1 BATHROOM HEATER

Morco House Riverview Road Beverley HU17 0LD. Retrofit or Upgrade a Water Heater in a Caravan Holiday home

TITAN Fuel Tanks. INSTALLATION INSTRUCTIONS G e n e r a t i o n V

XL PREMIUM OIL COOLER KIT

Installation Instructions

Important: Please read these instructions carefully and completely before starting the installation. TITAN Fuel Tanks

Air Conditioner Duct Construction & Repair

Installation Instructions

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

with installation dynafact boost GAUGE this manual is for use with systems

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

Figure 22: Typical Individual Venting. Figure 21: Single Water Heater Venting

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

HEAT WAVE DUCT KIT KIT #

CUSTOM AUXILIARY FORWARD LIGHTING KIT

Installation Instructions For Slider Casement Air Conditioners

RZ Guardrail System Installation Manual

Installation Operation & Maintenance Manual

DYNA RIDER FOOTBOARD KIT

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

NFPA31FuelOilPiping 1 Revised

BILLET HEADLAMP WITH SHORT/TALL MOUNTS

Installation Instructions

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Gas-Fired, Residential Storage Type Water Heaters

Installation Instructions

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

1. Description. 2. List of Accessories included A B C F G H

How To Install An Evaporator Coil

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

TITAN Fuel Tanks. Extended Capacity Replacement Tank for Diesel Chevrolet / GMC Trucks

INFRARED QUARTZ WALL HEATER

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS

INSTALLATION INSTRUCTIONS SLP98UHV DAVE LENNOX SIGNATURE COLLECTION GAS FURNACE UPFLOW / HORIZONTAL AIR DISCHARGE

Tech. Services: (800) Fax: (800) Order Entry: (800) Fax: (800) Internet Address:

Your safety and the safety of others are very important.

Installation & Operation Manual Models: ER152, ER202, ER252, ER302, and ER402

SIMPLAIR PIPING TOOL

Cooktop Low-Profile Ventilation Hoods

Arctic Leash Instruction Manual Alaskan Products Company LLC.

Installation Instructions - For the following HEATER model numbers: 200, 300, 400, 500 Series Hydronic Heaters

Installation Instructions:

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

V47 Series Temperature Actuated Modulating Water Valves

Chapter 10 - Scaffolding Systems

INSTALLATION AND OPERATING INSTRUCTION MANUAL

AM/FM ANTENNA KIT (TOUR-PAK MOUNT)

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

INSTALLATION INSTRUCTIONS FOR INTERNATIONAL 9000 SERIES ROOF TOP AIR CONDITIONERS

FREESTANDING CLEAN AIR WOODBURNER

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Exhaust Calculation Booklet

Sliding Barn Door Hardware Installation Instructions BALDUR and ODEN

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

2" & 3" Poly Wet Seal Pump Instruction Manual

OWNER S MANUAL DRAINVAC ATOMIK PRINTED APRIL

PURCHASED. IF YOU ARE UNSUCCESSFUL, PLEASE WRITE TO THE COMPANY LISTED ON THE RATING PLATE ON THE WATER HEATER.

Cooling Capacity CFM in. w.c. (125 Pa)

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

San josé OWNER S MANUAL

IMPORTANT SAFETY UPDATE

Instruction No. AERCO INTERNATIONAL, Inc., Northvale, New Jersey, USA. Venting Guide

Installation Instructions

Float and Thermostatic Traps Series H, C and X

L /96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

James M. Pleasants Company

StorMax Cable and Interconnect Installation Instructions

EASY$ TIP SHEETS. Energy Advice Saving Yukoners Money

Packaged Terminal Air Conditioner Wall Sleeve Installation

HC-3000 SERIES RAKE Parts Breakdown DURABILT INDUSTRIES, LLC AIRPORT ROAD POCAHONTAS ARKANSAS 72455

Installer s Guide 18-AH39D1-13

2010 Residential Water Heater Replacement Check List

AZEK Rail Install Guide

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Welding Reel ERA 4000 Service Manual

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

High efficiency, cast-iron gas boiler

MFH-5057 Ford Small-Block V-8 Fresh Water Cooling Kit Instructions

Transcription:

INSTALLATION OF VENTING SYSTEM COMPONENTS WARNING When installing the EVERHOT IGI model series direct vent water heaters, use only EVERHOT vent/air intake system kits and components. Installation and service must be performed by a qualified installer, service agency or the gas supplier. Installation must meet all state and local codes regarding installation and location of vent systems for direct vent appliances. In the absence of local codes, the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/or CSA B149.1, Natural Gas and Propane Installation Code. The maximum vent length, as stated in the EVERHOT IGI model series Water Heater Installation and Operating Instruction Manual and these instructions, should never be exceeded. Follow the instructions below and all instructions located in the EVERHOT IGI model series Water Heater Installation and Operating Instruction Manual when installing a vent pipe system. Improper installation of vent piping, or failure to follow all installation instructions completely, can result in property damage, and/or death. WARNING Refer to the LAARS EVERHOT IGI series Water Heater Installation and Operating Instruction Manual for details concerning vent system termination positions/clearances, allowable vent pipe lengths, and in what position dip switch #1 should be placed. If you do not understand how to configure your vent pipe system and/or which position dip switch #1 should be placed in, please contact your supplier for assistance. WARNING All joints in the vent/air intake piping must be taped with aluminum tape at the completion of the venting system installation to prevent any possible leakage into the room. Make sure all the pipe connections are firmly pressed together so that the gaskets form a tight seal. Prior to the Installation of EVERHOT direct vent systems: The EVERHOT IGI water heaters have two adjustable wall mounting support brackets fitted on the top and bottom of the appliance. When installing a Standard Vent Discharge Kit" to vent directly through the wall to the back of the water heater, these brackets should be adjusted so that the water heater is spaced its maximum distance of 2" (5.1 cm) away from the wall. Before cutting the vent terminal to the appropriate length, ensure you have taken into account just how far the heater has been spaced away from the wall. NOTICE When mounting the water heater on an outside wall, be sure the Vent/Air Intake Pipe will exit between the wall studs. DO NOT cut through the wall studs for the Vent/Air Intake Pipe opening.

WARNING All joints in the vent/air intake piping must be taped with aluminum tape at the completion of the venting system installation to prevent any possible leakage into the room. Make sure all the pipe connections are firmly pressed together so that the gaskets form a tight seal. WARNING Before installation inspect each vent component for damage and correct seal placement. Do not attempt to fix or install any damaged vent components. Condensate When the total vent system length is greater than 5 ft. (1,52 m), condensate will form which could damage the water heater. For vent lengths greater than 5 ft. (1,52 m), a condensate collector and trap must be installed. Recommended vent/air intake terminal position Terminals should be so positioned as to avoid products of combustion entering openings into buildings or other flues or vents. Figure 12 2

* For clearances not specified in ANSI Z223.1 / NFP A 54 or CGA-B149, please use clearances in accordance with local installation codes and the requirements of the gas supplier. ** For other than Direct Vent Appliance, 4 feet (1.22 m) below or to side of opening; 1 foot (300 mm) above opening. 3

General Installation Instructions Joint connection Figure 13 Vent connections others must be firmly pressed together so that the gaskets form an airtight seal. Coping with condensation Figure 14 Make sure that the sockets are pointed 1 upwards in order to keep the gaskets dry. (Except for the (short distance) standard horizontal discharge vent system without extensions. See Figure 34.) Appliance connection Figure 15 The first vent component to the appliance must be a vertical discharge adapter or a horizontal discharge adapter. Never use an extension as the first component, this might cause damage to the water heater and vent system. Secure vent connections with pipe clamps or perforated hanger. 4

Condensate drain Every vent system should have a condensate collector unless installed with a total vent length of less than 5 ft. (1,52 m). To prevent condensate from draining back to the appliance, a condensate collector (B) and trap (C) should be installed. Attach condensate collector to the discharge adapter (A). The trap must be inspected annually for obstructions and water content in the trap. Provisions must be made to properly drain and dispose of condensate; be aware that condensate is a highly corrosive substance that could damage metals. The hose (D) should be subject to inspection; kinks must be avoided. Dispose of condensate in accordance with local codes. Minimum water level in the condensate trap must be 3 (75 mm). Figure 16 Shortening of vent extensions Figure 17 The aluminum inside pipe should always extend 0.4" (10 mm) beyond the white plastic outside pipe on the male end of the vent extension. Always cut the male end of the vent pipe extension. Do not attempt to cut the female end. Figure 18 Pipes overlap by 2.5 (65 mm). Therefore when cutting to size, add 2.5 (65 mm) to the extension pipe length (X) needed for installation. Deburr the sharp edges, other wise the gaskets may get damaged, which can result in the system no longer being air tight. 5

WARNING Improper installations of vent system and components, or failure to follow all installation instructions, can result in property damage or serious injury. Parts & Dimensions Components needed for direct vent applications: Figure 19 Figure 20 1) horizontal discharge adapter 2) vertical discharge adapter BWC p/n 239-44506-00 BWC p/n 239-44500-00 Figure 21 Figure 22 3) wall discharge terminal plate 4) rubber wall Length = 12 (305mm) BWC p/n 239-46848-00 Part of BWC vent kit 6

Figure 23 Figure 24 Figure 25 5) vent extension 6) 45º vent pipe elbow 7) 90 º vent pipe elbow 10 BWC p/n 239-44496-00 (sold in pairs only) BWC p/n 239-44499-00 19.5 BWC p/n 239-44497-00 BWC p/n 239-44495-00 39 BWC p/n 239-44498-00 Figure 26 Figure 27 8) condensate collector 9) vent pipe clamp BWC p/n 239-44501-00 BWC p/n 239-44493-00 Figure 28 Figure 29 10) vertical discharge roof terminal 11) pitch roof flashing BWC p/n 239-44494-00 (1/12) BWC p/n 239-44502-00 (8/12) BWC p/n 239-44503-00 (6/12) BWC p/n 239-44504-00 7

Figure 30 Figure 31 12) flat roof flashing 13) condensate trap kit BWC p/n 239-44492-00 8

Installation Instructions Everhot Horizontal Discharge Vent System Identify the vent location Figure 32 Steps: - Place horizontal discharge adapter on water heater - Mark position on wall - Or use template provided with water heater - Cut hole, covering the top of the water heater to prevent debris from entering Measure dimension to fit Figure 33 Figure 34 NOTICE Note: if the vent system is shorter than 5 ft. (1,52 m) and no condensate collector is installed, be sure to install the wall terminal with a 1 angle to the outside of the building. 9

NOTICE Note: 3.5 (90 mm) is the minimum outer cap length. If needed the length outside the wall may exceed this dimension. Final installation of the venting system Figure 35 From the outside of the building, slide the wall discharge terminal through the vent wall passage. A supplied rubber wall plate can be installed on the exterior of the building. Slide the inner wall plate onto the terminal. If necessary apply silicon sealant to fill up spaces between vent terminal and the wall. Vent connections must be firmly pressed together so that the gaskets form an airtight seal. NOTE When the total vent system length is greater than 5ft. (1,52 m), condensate will form which could damage the water heater. For vent lengths greater than 5ft. (1,52 m), a condensate collector and trap must be installed. 10

Horizontal Vent System Installation examples Figure 36 11

Installation Instructions Everhot Vertical Discharge Vent System Identify the vent location Figure 37 Determine the location where the roof discharge terminal will be installed. Taking into account the angle of the roof, cut the hole with a dimension that allows the vertical discharge roof terminal to be installed. Cut to fit The terminal can be shortened by removing the components A+B+C, and then shortening both the inside and outside pipes with the same length X. Re-assemble the terminal by attaching the components A, B, and C in the correct order. Tighten component B securely. Figure 38 12

Mounting the vent system Figure 39 Vent connections must be firmly pressed together so that the gaskets form an airtightseal. Secure the system with the supplied vent pipe clamp or perforated hanger iron. NOTE When the total vent system length is greater than 5ft. (1,52 m), condensate will form which could damage the water heater. For vent lengths greater than 5ft. (1,52 m), a condensate collector and trap must be installed. 13

Vertical Vent System Installation examples Figure 40 14

Cut Line Template 15

800.900.9276 Fax 800.559.1583 (Customer Service, Service Advisors) 20 Industrial Way, Rochester, NH 03867 603.335.6300 Fax 603.335.3355 (Applications Engineering) 1869 Sismet Road, Mississauga, Ontario, Canada L4W 1W8 905.238.0100 Fax 905.366.0130 www.laars.com Litho in U.S.A. Laars Heating Systems 0810 Document 11046