Electronic pressure switch with integrated analogue output

Similar documents
PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Conductive Level Switch FK 2 Technical Data:

Electronic Pressure Switch EDS 3000

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Pressure transmitter For general industrial applications Model A-10

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

Series 7500 Torque Sensor

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Series 6000 Torque measured metal bellow coupling

Electronic Pressure Switch EDS 300

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Rotary actuators Rotary wing drives Series RAK. Brochure

Features. Picture. Specifications

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Electrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

Inductive sensor NI10-M18-Y1X-H1141

EFC Frequency converters

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

Data Sheet PS1B Pressure Switch

Relative and absolute pressure switch type 529

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Frequency Converter Fv

Turbine Flow Sensor Series VTR

How To Use A Flowmeter

Series 8146/5-V37 and Series 8150/5-V37

Analog Command Value Card Type VT-SWKA-1

Givare NC-SRS 280 och 880

Pressure reducing valve, direct operated, Type ZDR 6 D

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Analog signal converters CC-E I/I Current / current isolators

Fixed displacement vane pumps

49 Series - Relay interface modules A. Features

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Proportional pressure regulators VPPE

Digital input modules

Cable Plug acc. to DIN EN , Form A

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Electronic Pressure Monitoring New Products

Digital inductive conductivity transmitter

Dimensional drawing. Connection type IME08-1B5NOZT0S IME08-1B5NSZT0S IME08-1B5POZT0S IME08-1B5PSZT0S. 3 x 0.14 mm². brn. L+ Schließer/ Öffner M.

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Technical Data. Dimensions

2/ These vacuum switches are used in measuring ranges between -1 and 0 bar.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Reaction Torque Sensor

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Air damper actuators

3/2-way Solenoid Valve, direct-acting, NC or NO

Single sub-base valve

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

RM4TG20 three-phase network control relay RM4-T - range V

Safety technique. Emergency stop module BO 5988 safemaster

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Table of Contents, Magnetic Field Sensors. Introduction to Magnetic Field Sensors

Supplementary instructions. Connection cable IP 66/IP 68 (1 bar) Retrofitting set/accessory for instruments of the plics family. Document ID: 34107

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

RY2 miniature industrial relays

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

48 SERIES Relay interface modules 10 A

3-phase, bidirectional energy meter

3-Component Measuring System

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Energy Management Energy Meter Type EM23 DIN

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Operating instructions Optical distance sensor O1D100 O1D / / 2012

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Digital display DA 48

4 Posiflow Proportional Solenoid Valves

ATL Fuel Level Sender Probes

Relative pressure transmitter type 520

How To Read A Pipe From A Sensor

crm+25/d/tc/e Extract from our online catalogue: Current to:

BOS 73K... BOS 74K...

38 Series - Relay interface modules A

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

Description. Specifications and Ordering Information and Accelerometer Acceleration Transducers

Inductive proximity sensors IM 12 series, sensing range 2 / 4 mm DC 3-wire, metal housing

2-way flow control valve Type 2FRM 6

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

Duct Humidity Transmitter

3/2- and 2/2-way cartridge valve type BVE

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Transcription:

Electronic pressure switch with integrated analogue output RE 30276/03.06 Replaces: 01.06 RE 30275 1/6 Type HEDE 10 /1/ Component series 2X tb0002 Table of contents Contents Page Features 1 Ordering code 2 Technical data 2 and 3 Pin assignment K41 3 Unit dimensions 4 Accessories 5 and 6 Features Suitable for measuring pressures and converting the measured values into electrical signal variables in hydraulic systems EMC properties allow the use of this pressure switch also in critical applications Ceramic / capacitive sensor Connecting cable with 4-pin M12 plug on housing Accuracy class 1.0 Connection thread G1/4 Parts in contact with media are made of stainless steel, ceramic and FKM Compact design One switching output and one analogue output

2/6 Bosch Rexroth AG Hydraulics HEDE 10 /1/ RE 30276/03.06 Ordering code HED E 10 A1 2X K41 G24 1 V * Hydraulic electrical pressure switch Integrated electronics = E Component type = 10 Hydraulic interface 1/4 = A1 Component series = 2X Pressure stages 100 bar = 100 250 bar = 200 400 bar = 400 600 bar = 600 K41 = G 24 = Further details in clear text V = FKM seals Caution! Observe compatibility of seals with hydraulic fluid used! 1 = One switching and one analogue output Supply voltage Plug variant M12, 4-pin as standard Technical data (for applications outside these parameters, please consult us!) Input variables Auxiliary energy U O 18 to 36 VDC Current consumption I < 50 ma Measuring range p N in bar 100 250 400 600 Overload safety p max in bar 300 400 600 800 Burst pressure p in bar 650 850 1000 1200 Output variables Analogue output U 0 to 10 VDC minimum load 2000 Ω I 4 20 ma (max. load (U O 10) x 50 Ω) Rise time (10 to 90 %) t 3 ms Switching output Current carrying capacity I 250 ma Response time t < 3 ms (with response time set to dap = 3) Max. switching frequency f 170 Hz (at dap = 3) Characteristic curve deviation: < ±0.5 % (initial point setting according to DIN16086) Temperature coefficient within nominal temperature range Highest TC of zero point Highest TC of span 0.2 % / 10 k 0.2 % / 10 k Hysteresis < ±0.1 % Repeatability 0.1 % Long-term drift under reference conditions (6 months) 0.05 % Ambient conditions Limit temperature range ϑ 20 to +80 C Storage temperature range ϑ 40 to +100 C Medium temperature range ϑ 25 to +80 C Mechanical data Pressure port G1/4 Electrical connection M12 plug-in connection

RE 30276/03.06 HEDE 10 /1/ Hydraulics Bosch Rexroth AG 3/6 Technical data (continued) Programming options Hysteresis / window; normally open / normally closed; pickup, drop-out delay; attenuation; display unit / analogue output: voltage or current Pressure stages 100 250 400 600 Switching point SP bar 1.0... 100 2... 250 4... 400 6... 600 Release position, rp bar 0.5... 99.5 1... 249 2... 398 3... 597 In increments of bar 0.5 1 2 3 Adjustable response time of a switching output and resulting switching frequency Response time (dap) ms Hz 3... 500 170... 1 Adjustable delay time ds, dr s 0.0; 0.2... 50.0 Environmental compatibility Type of protection / housing to IEC 60529 IP67 Class of protection EN 50178 III Insulation resistance MΩ > 100 (500 VDC) Resistane to shock to IEC 60068-2-27 g 50 g, 11 ms Resistance to vibration to IEC 60068-2-6 g 20 g, 10... 2000 Hz Switching cycles min. 100 million / 50 million with pressure stage 600 bar Approval culus EMC Housing material Materials in contact with the medium Connection EN 61000-4-2 ESD EN 61000-4-3 HF radiated EN 61000-4-4 burst EN 61000-4-5 surge EN 61000-4-6 HF cable-bound 4 / 8 kv 10 V/m 2 kv 0.5 / 1 kv 10 V EPDM/X (Santoprene); FKM; PBTP (Pocan); PC (Macrolon); V2A (1.4301) V2A (1.4305); ceramic; FKM M12 plug-in connection, gold-plated contacts Pin assignment K41 One switching and one analogue output: HEDE 10 1 BN 4 BK 2 WH 3 BU L + L Detail of plug on the device: 2 3 4 1 1 BN Brown 2 WH White 3 BU Blue 4 BK Black

4/6 Bosch Rexroth AG Hydraulics HEDE 10 /1/ RE 30276/03.06 Unit dimensions (nominal dimensions in mm) 1 2 3 Ø 34 4 48 M12 x 1 1 Status LEDs 2 4-digit alphanumerical display 3 Programming key 4 Dimension for pressure stage 100 bar and 250 bar 5 Dimension for pressure stage 400 bar and 600 bar 91,5 (94) 4 M12 x 1 5 57,3 (59,8) Ø 21,5 1,3 30 13,5 5 Recommended installation: Vibration-free installation! Ø 27 G1/4 Tightening torque 20 to 30 Nm

RE 30276/03.06 HEDE 10 /1/ Hydraulics Bosch Rexroth AG 5/6 Accessories Cable sockets: Technical data: Designation Material no. Current carrying capacity 4 A 04 POL (with 2 m cable) R900773031 15 42 Temperature range 25...90 C 04 POL (with 5 m cable) R900779498 Type of protection IP 67 Contacts CuZn Contact surface Gold-plated M 12x1 Housing TPU Seal FKM 04 POL (with 2 m cable) R900779504 Fitting CuZn/Ni 15 27 04 POL (with 5 m cable) R900779503 Wire cross-section 4 x 0,34 mm Sheath material PUR Shield Not connected on plug side Sheath diameter Ø 5.0 mm M 12x1 Sheath colour Black Bending radius for min. 50 mm Ø10,5 dyn. application Connection: 20 39 17 22 19 G 1/4 5 Ø10,5 46 04 POL (without cable) 1) R900773042 1 BN 2 WH 2 M12x1 3 BU 1 3 20 36 04 POL (without cable) 1) R900779509 4 BK 4 30 Ø18 M12x1 Ø15 1) Type of protection IP68 Hydraulic fitting: Designation AB 20-28 Material no. R900012451 Elastic profiled seal 12 2 49 O-ring

6/6 Bosch Rexroth AG Hydraulics HEDE 10 /1/ RE 30276/03.06 Accessories (continued) Mounting clamp for HEDE 10 Designation Mounting clamp Material no. R900786138 70 58 12 6,5 ø34 29 52 Protective cap for HEDE 10 Designation Protective cap M12 Material no. R900786141 ø37 45 35 ø3 ø16 Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

RE 30276/03.06 HEDE 10 /1/ Hydraulics Bosch Rexroth AG 7/6 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

8/6 Bosch Rexroth AG Hydraulics HEDE 10 /1/ RE 30276/03.06 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Phone +49 (0) 93 52 / 18-0 Fax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.