Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION The high accuracy Model TJE low range wet/wet differential pressure transducer offers a stainless steel assembly. The Model TJE line pressure zero shift specification can be reduced to less than 0.5 % FS/1000 psi by the use of an internal line pressure sensor and analog correction circuit. Line pressures are available up to 5000 psig with safe overload of either side up to the maximum line rating. The natural resonant frequency is increased with the Model TJE because of a stiffer pressure sensing element. A variety of options are available with the Model TJE including choice of removeable pressure adaptors, pressure ports, internal amplifiers, and electrical terminations. FEATURES 0.1 % FS accuracy 0.5 psid to 30 psid mv/v (standard), 4 ma to 20 ma, 0 Vdc to 5 Vdc, or 0 Vdc to 10 Vdc output Intrinsically safe available (2N option only) 10 CE approved 11
PERFORMANCE SPECIFICATIONS Pressure ranges Accuracy Output (standard) 0.5 psid Output (standard) 1 psid to 4 psid Output (standard) 5 psid to 30 psid Line pressure Resolution ±0.5, 1, 2, 5, 10,15, 25, 30 psid** ±0.1 % full scale 1.0 mv/v (nominal) 1.5 mv/v (nominal) 2.0 mv/v (nominal) 1500 psi Infinite RANGE CODES Range Code Available ranges Range Code AP ±1 psid BJ ±15 psid AR ±2 psid BL ±25 psid AT ±5 psid BM ±30 psid AV ±10 psid Available ranges Mounting dimensions and characteristics ENVIRONMENTAL SPECIFICATIONS Temperature, operating -1 C to 88 C [30 F to 190 F] Temperature, compensated -1 C to 54 C [30 F to 130 F] Temperature, effect, zero ±0.5 % full scale/100 F Temperature, effect, span ±0.5 % reading/100 F 50,8 mm [2 in] max. ELECTRICAL SPECIFICATIONS Strain gage type Bonded foil Excitation (calibration) 10 Vdc Excitation (acceptable) Up to 10 Vdc or ac Insulation resistance 5000 mohm @ 50 Vdc max. Bridge resistance 350 ohm (nominal) Shunt calibration data Included Elec. termination (std) Bendix PTIH-10-6P or equivalent Mating connector (not incl.) Bendix PT06A-10-6S or equiv. (AA111) Typical system diagram MECHANICAL SPECIFICATIONS Media All fluid and gases compatible with 316 stainless steel Overload-safe 1500 psi Pressure port 1/8-27 NPT female (2) Dead volume Wetted parts material Weight Case material 0.4 cu. in 316 stainless steel 3.6 kg [8 lb] Stainless steel 2 Honeywell Sensing and Control
Low Range Wet/Wet Differential Pressure Transducer OPTION CODES Pressure ranges (psid) Temperature compensation Internal amplifiers Internal amp enhancements Many range/option combinations are available in our quick-ship and fast-track manufacture programs. Please see http://sensing.honeywell.com/ TMsensor-ship for updated listings. 1, 2, 5, 10, 15, 25, 30 1a. 60 F to 160 F 1b. 30 F to 130 F 1c. 0 F to 185 F 2u. Unamplified, mv/v output 2b. 4 wire ±5 Vdc 2c. 0 Vdc to 5 Vdc 2j. 4 ma to 20 ma (three-wire) output 1d. -20 F to 130 F 1j. 0 C to 50 C 2k. 4 ma to 20 ma (two-wire) output 12 2n. (2N) 4 ma to 20 ma (two-wire) intrinsically safe 12 2t. 0 Vdc to 10 Vdc 3a. Input/output isolation 8 3d. Remote buffered shunt calibration WIRING CODES Connector Unamplified A, B (+) excitation C, D (-) excitation E (-) output F (+) output 5h. 1/8-27 NPT female (2) Pressure ports 5 5a. 1/4-18 NPT female 5c. 7/16-20 UNF female Electrical termination Shunt calibration Special calibration Wetted diaphragm 6a. Bendix PTIH-10-6P (or equiv.) 6 pin (max. 120 C) 6e. Integral cable: Teflon (-54 C to 245 C) 6f. Integral cable: PVC (-30 C to 70 C) 6g. Integral cable: Neoprene (-20 C to 80 C) 1 6h. Integral cable: Silicone (-54 C to 150 C) 8a. Precision internal resistor 6 6i. Integral underwater cable (8m [26 ft]) (max. 80 C) 1 6j. 1/2-14 conduit fitting with 1,5 m [5 ft] of 4 conductor PVC cable 6m. DIN 43650 6q. Molded integral cable: Polyurethane 1 6t. Integral cable with heyco spring strain relief (1.6 m [5.2 ft]) 9a. 10 point (5 up/5 down) 20% increments @ 20 C 9b. 20 point (10 up/10 down) 10% increments @ 20 C 10a. 316 stainless steel Bridge type 11a. Square bridge 6 11b. Symmetrical bridge 6 11c. Square & symmetrical bridge 6 Zero and span adjustment 14a. No acces to pots 14b. Top access to pots 7 Interfaces 53e. Signature calibration 6 53t. TEDS IEEE 1451.4 module 9 Honeywell Sensing and Control 3
INTERNAL AMPLIFIERS Amplifier specifications Option 2b Option 2c Output signal ±5 V 0 V to 5 V or ±5 V @ 5 ma Option 2t 0 V to 10 V or ±10 V @ 5 ma Current three-wire: Option 2j Current two-wire: Option 2k Intrinsically safe amp: Option 2n (2N)*** 4 ma to 20 ma 4 ma to 20 ma 4 ma to 20 ma Input power (voltage) ±15 V or 26 Vdc to 32 Vdc 11 Vdc to 28 Vdc 15 Vdc to 28 Vdc 22 Vdc to 32 Vdc 9 Vdc to 32 Vdc 9 Vdc to 28 Vdc Input power (current) 45 ma 40 ma 40 ma 65 ma 4 ma to 28 ma 4 ma to 24 ma Freq. response (amp) 3000 Hz 3000 Hz 3000 Hz 2500 Hz 300 Hz 2000 Hz Power supply rejection 60 db 60 db 60 db 60 db 60 db 60 db Operating temperature -20 F to 185 F -20 F to 185 F -20 F to 185 F 0 F to 185 F 0 F to 185 F -20 F to 185 F Reverse volt. protection Yes Yes Yes Yes Yes Yes Short circuit protection Momentary Momentary Momentary Yes Yes Yes Wiring code: connector (std) 2 B Output common C Supply return C Supply return ** C Supply return** C Supply return** B No connection C No connection E Case ground F No connection B No connection C No connection E Case ground F No connection Wiring code: cable 2,3,4 Bl Output common G Supply return Bl (+) Output W Case ground Bl (+) Output W Case ground * Black and green wires are internally connected. ** Pins B and C are internally connected. *** See Honeywell s Web site for the most up-to-date information regarding Intrinsically safe approvals, ref #008-0547-00. 4 Honeywell Sensing and Control
Low Range Wet/Wet Differential Pressure Transducer NOTES 1. Availability varies according to range. 2. Interconnecting shunt cal. 1 terminal with shunt cal. 2 terminal provides 50% (unamplified units), 75% (4 ma to 20 ma 3-wire units) or 80% (voltage amplified units of full scale output for quick calibration. Shunt calibration comes standard with internal amplifier options 2b, 2c, 2t and 2j.) 3. O=Orange, Y=Yellow, B=Blue, Bl=Black, R=Red, Br=Brown, W=White, G=Green. Color specifying cable and number or letter specifying connector. 4. No mating connector necessary for cable option. 5. Some pressure port options may require axial orientation. 6. Only available with unamplified option 2u. 7. Only available with amplified options. 8. Only available with Vdc output options 2b, 2c. 9. Consult factory for TEDS availability with amplified models. 10. Range dependent; consult factory. Termination dependent; consult factory. 11. Internal amp and termination dependent; consult factory. 12. 5000 ohm bridge required. ** Option: also available, equivalent inches of water column, inches of HG column, mbar or kpa for pressure ranges Note: Unless otherwise specified on order, amplified units with 4 ma to 20 ma output will provide 4 ma at 0 psid and 20 ma at positive full scale and the unit will not operate in the negative direction. An available is to specify 4 ma at negative full scale and 20 ma at positive full scale. All amps add 2 in to housing. Warranty. Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. For more information about Sensing and Control products, visit www.honeywell.com/sensing or call +1-815-235-6847 Email inquiries to info.sc@honeywell.com WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION The information presented in this catalogue is for reference only. DO NOT USE this document as product installation information. Complete installation, operation and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. Sensing and Control Automation and Control Solutions Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 USA +1-815-235-6847 www.honeywell.com/sensing 008767-1-EN IL50 GLO May 2008 Copyright 2008 Honeywell International Inc. All rights reserved.