Instruction Manual Model

Similar documents
INSTRUCTION MANUAL T1 TO RS422 INTERFACE

Advantium 2 Plus Alarm

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

F2400 FOM II Series Fiber Optic Modem Technical Manual

Uninterruptible Power Supply

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

V-2901 UNIVERSAL DOOR ANSWERING SYSTEM

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

2-Pair HDSL1 Adtran Fiber Optic Link System

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

BroadBand PowerShield. User Manual

Installation and Operation Guide PD4600 Series Converter Replacement

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

DCX300 - DCX400 - DCX600

EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

OWNER'S MANUAL. Model CUL AC Power Inverter/Charger System OM/A96283 REV. A

Single Station Remote Alarm

INSTALLATION. Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier

Model SRMD Setra Remote Monitoring Display

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Signal Manager Installation and Operation Manual

HM-W536 Install Guide

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

Single Port Gigabit Ethernet Media Converter Board (P/N xxx) User s Manual And Troubleshooting Guide

is then retained absolutely without interruption.

EMBEDDED ACCESS CONTROL Hardware Installation Guide

User Manual. ATX12V / EPS12V Power Supply TG-I460R (460W+460W) TG-I550R (550W+550W) Switching Power Supply User Manual

PagePac PAGEPAL V

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

Contents. Safety Warnings... 1

SETUP GUIDE SNMP ALARM ADAPTOR COMPATIBLE WITH SIGMA, RADIAN, TPCMQ, auro-he & BLUEstreak POWER SHELVES

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

RIU-IP Remote IP Interface User Guide

Installation and Operation Guide for PD4000 Series Power Control Center

Perle 10/100 Ethernet Media Converters

Original instructions Tina 3A/Aps Adaptor unit

PSC POWER STAR LiFE TM

Remote Alarm Monitoring System

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

User s Manual Before using the inverter, you need to read and save the safety instructions.

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

TTL to RS232 Adapter User Guide

USER MANUAL. Kramer Electronics, Ltd. Models:

Installation and Operation Guide for PD4100 Series Power Control Centers

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Installation and Operation Back-UPS 1250, 1300, 1500

16/32 Channel 1U Rack Mount CCTV Power Supply

TrueAlarm Fire Alarm Systems

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

User Manual for CH-PFC76810

User Guide. HDMI Active Cable Extender. DVI-7370c

Applied Electronics. Commercial Dimming System UPDATE NOTICE

How To Use A Power Supply Unit (Upu)

I STAR COMPUTER CO., LTD

Model DB 750 Tube Bass Head

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

InHome Water Leak Detection Package

AUTODIALLER / QUICKDIALLER - SA132

Back-UPS Pro 1300/1500 Installation and Operation

GSD 22 Sounder Module. installation instructions

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

Comfort Control Relay Panel (CCRP)

Single Port T1/E1 Tap

Innovative Electronics for a Changing World INDEX

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Triple Expansion Chassis

Specification Requirements DBL 700MX and 1000MX Series UPS

MCR1900 Media Converter 19-Slot Chassis

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Model SPDT Relays

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

PEDAL POWER. User s Manual

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

Co-location Interconnect Power Panel (CIPP) Installation Guide

Operating Manual UWAPS-TINY Series

Manual. Solar Fountain Mobile Phone Charger

ZC-24DO CANopen I/O Module: 24 Digital Outputs

DCP Fan Controller. Version 01/2009. The engineer s choice

Zetron Desktop Microphone Manual F

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Rack mounted telephone- and leased line modem for industrial applications

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

LESTRONIC DV AUTOMATIC 12 OR 24 VOLT DUAL OUTPUT DUAL MODE BATTERY CHARGER MODEL TYPE 12/24EL40-10ET

PowerStar Mini Triple Play TM

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Installation Guide for Gig Zero Delay Tap and 10/100/1000BaseT Tap

DOSISYS. Hands Free Reader LDM LDM 220. User Manual A

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

User manual Rev. 1.2 (17/04/2015)

CONTROL SWITCHER User s Manual (Preliminary)

, User s Manual

Transcription:

Instruction Manual Model 2000-16-3624 Power Supply/ Charger September 2015, Rev. 0 Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating the equipment. When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number, equipment serial number, and a description of the part. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB: www.crosstechnologies.com E-MAIL: info@crosstechnologies.com

INSTRUCTION MANUAL MODEL 2000-16-3624 Power Supply/ Charger TABLE OF CONTENTS PAGE Warranty 2 1.0 General 3 1.1 Equipment Description 3 1.2 Technical Characteristics 5 2.0 Installation 7 2.1 Mechanical 7 2.2 Top & Side Panels, Inputs, Outputs & Indicators 8 2.3 Operation 9 2.4 Alarm Indication 10 2.5 Connector Pinouts 10 3.0 Environmental Use Information 11 WARRANTY - The following warranty applies to all Cross Technologies, Inc. products. All Cross Technologies, Inc. products are warranted against defective materials and workmanship for a period of one year after shipment to customer. Cross Technologies, Inc. s obligation under this warranty is limited to repairing or, at Cross Technologies, Inc. s option, replacing parts, subassemblies, or entire assemblies. Cross Technologies, Inc. shall not be liable for any special, indirect, or consequential damages. This warranty does not cover parts or equipment which have been subject to misuse, negligence, or accident by the customer during use. All shipping costs for warranty repairs will be prepaid by the customer. There are not other warranties, express or implied, except as stated herein. CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 (770) 886-8005 FAX (770) 886-7964 Toll Free 888-900-5588 WEB www.crosstechnologies.com E-MAIL info@crosstechnologies.com 2000-16-3624 Manual_Rev.0 Page 2 09/17/15

MODEL 2000-16-3624 Power Supply/ Charger 1.0 General 1.1 Equipment Description The 2000-16-3624 Power Supply/ Charger uses a +10VDC to +36VDC input to provide +24VDC @3A and +12VDC @3A outputs used for remote terminals. Additionally the power supply will operate from up to 4 BB-2590 type military batteries when DC input power is not available. The power supply provides all the functionality and safety features of a Level 2 charger and with optional Ethernet will provide Level 3 charger capabilities. With DC input power applied, the power supply will charge the batteries as needed based on the data collected from the batteries via the SMBus to a maximum of 8 Amps total charge current. The power supply can be used as a stand alone charger. LED indicators show battery status, Primary Power Source, +12V and +24VDC Status. The power supply is housed in a 10 X 16 X 1.5 enclosure (connector protrusion not included). SIDE PANEL (Shown with optional Ethernet) TOP PANEL FIGURE 1.1 Top and Side Panels 2000-16-3624 Manual_Rev.0 Page 3 09/17/15

1.1 Equipment Description (continued) DC IN 10-36V DC TO DC +24V@400W BAT "A " DUAL BAT MNGMT BAT "B" BAT " C" B AT "D" DU A L BAT MNGMT DUAL BAT MNGMT DUAL BAT MNGMT DC TO DC +24VDC DC TO DC +12VDC +24VDC 3A MAX +12VDC 3A MAX SMBus MICRO INDIC ATORS ETHERNET (OPTIONAL) BB -2590 TY PE BB-2590 TY PE BB-2590 TY PE BB-2590 TY PE FIGURE 1.2 2000-16-3624 Power Supply/ Charger Block Diagram DC Input Connector Terminal Block 40 A Maximum Power Switch +24 VDC Output Connector, Molex 2 Pin Female +12 Output Connector DB-9 Female RJ-45 Ethernet Connector (Optional) FIGURE 1.3 2000-16-3624 Power Supply/ Charger Side Panel 2000-16-3624 Manual_Rev.0 Page 4 09/17/15

1.2 Technical Characteristics TABLE 1.0 2000-16-3624 Power Supply/ Charger Equipment Specifications* DC Input Characteristics Voltage Input Power DC Output Characteristics Voltage/Current Load Regulation Power Supply Type Switching Frequency Charger Characteristics Number of Chargers Charger Type Charger Current Chargeable Type LED Indicators Power Alarm Primary Power (2) DC Outputs (2) SOC Indicators Green (Flashing = Charging) Yellow (Flashing = Charging) Red (Flashing = Charging) All Off Physical Characteristics Size (Excluding Connector Protrusion) Weight Environmental Temperature Humidity Options W18 W28 +10VDC to +36VDC** 400 Watts Maximum (i.e., 40 Amps with +10VDC input) +12 VDC @ 3 Amps Maximum** +24 VDC @ 3 Amps Maximum** ±5% Switcher Various 4 Dual Level 2 Smart (Level 3 with Ethernet Option) 8 Amps Maximum Total BB-2590 with SMBus or Compatible Green Red (DC Outputs, Thermal, etc.) Green (DC Input or ) Green (+24VDC and +12VDC) 61% to 100% 21% to 60% 0% to 20% No SMBus Detected 10 W x 16 L x 1.563 D (254 x 406 x 39.7 mm) 10 lbs. (4.5 kg) 10 C - 40 C < 95%, Non-Condensing Ethernet with Web Browser & SNMP Ethernet with TCP/IP, Telnet * Specifications subject to change without notice. ** Consult Factory for different Input and Output Voltage Requirements. 2000-16-3624 Manual_Rev.0 Page 5 09/17/15

1.2 Technical Characteristics Continued... TABLE 1.0 2000-16-3624 Power Supply/ Charger Equipment Specifications* Continued I/O Connectors DC Input - 1701692 (Phoenix Contact) +24VDC Output - Molex 39-30-0020 +12VDC Output - D-Sub 9-pin Female Remote On/Off - Amp 6403892 - SN0019-5NA-0-0 (5 Key) Ethernet - RJ-45 Female (Optional) Mating Connectors 1967456 - (Phoenix Contact 6 20 AWG Wire) Molex 39-01-2020 (Contact 39-00-0039) D-Sub 9-pin Male Amp 640426-2 (18 AWG Wire) - SC-C-179495 (or equivalent) RJ-45 Male (Optional) * Specifications subject to change without notice. ** Consult Factory for different Input and Output Voltage Requirements. 2000-16-3624 Manual_Rev.0 Page 6 09/17/15

2.0 Installation 2.1 Mechanical Figure 2.0 shows how the 2000-16-3624 is assembled. +12VDC DC to DC +24VDC DC to DC Converter (Charging) P Dual Charger Dual Charger Dual Charger Dual Charger FIGURE 2.1 Mechanical Assembly 2000-16-3624 Manual_Rev.0 Page 7 09/17/15

2.2 Top & Side Panels, Inputs, Outputs, and Indicators Figure 2.2 shows the input and output signals and indicators on the top panel. LED Primary Source Indicators Power Status GREEN LED Alarm Status RED LED Status RED, GREEN, YELLOW LEDs Footman Loops for 1 Straps (4 Sets) Status RED, GREEN, YELLOW LEDs Status RED, GREEN, YELLOW LEDs Status RED, GREEN, YELLOW LEDs BB-2590 Connectors (4) SN0019-5x FIGURE 2.2 Top Panel Connections and Indicators Figure 2.3 shows the signals and indicators on the side panel. DC Input Connector Terminal Block. 40 A Maximum Power Switch +24 VDC Output Connector, Molex 2 Pin Female +12 Output Connector DB-9 Female + + RJ-45 Ethernet Connector (Optional) FIGURE 2.3 Side Panel Connections 2000-16-3624 Manual_Rev.0 Page 8 09/17/15

2.3 Installation / Operation 2000-16-3624 Power Supply/ Charger 1. The power switch is shipped with a jumper to turn on the unit. If a remote power switch is desired, remove the jumper and connect a remote power switch to the terminals (Open = Off, Closed = On). Remove connector while making the following connections! 2. Connect the +24VDC and +12VDC Outputs to respective devices. 3. Connect the DC Input to the mating connector with appropriate wire gauge and insert connector into unit. The DC Input Current is inversely proportional to the Input Voltage (i.e., a +10VDC input can have as much as 40 Amps of input current, whereas a +20VDC input should have no more than 20 Amps of input current). Make sure to size the input wire gauge appropriately for your application! 4. Install up to four BB-2590 or equivalent batteries as desired. Batteries are 'Hot Swappable' and can be added or removed at any time. Use one inch straps (not provided) through the 'Footman loops' to hold batteries in place. This is critical for mobile applications. 5. Connect the RJ-45 Ethernet jack to your network with appropriate network cable (Ethernet Option ONLY). Refer to Ethernet insert for detailed operation. 6. Apply power and insert ON/Off Switch jumper and/or turn remote power switch to the ON position. 7. Initial power up begins the unit's self test which includes LED test, DC Output Voltage and Current, Temperature, Charge voltage etc. After initial power up the Power LED, Primary Power (either DC Input or ), both +12VDC and +24VDC indicators should be illuminated and the Alarm LED should be off. Status indicators for all compatible batteries installed should also be illuminated according to their status. Non-compatible batteries will not have any status indicators illuminated but can be used to supply battery power to the unit. 8. Verify the Power Supply is providing appropriate power to the external devices. 9. Verify any compatible batteries in need of charging are being charged. 10. Should an Alarm condition occur, refer to Table 2.0 for assistance in determining the cause of the error. 11. The Power Supply/Charger has the option to disable charging of one or more batteries. The interior motherboard contains a four position slide switch (S1) allowing charging to be disabled to one of more batteries (A-D). Onboard LEDs illuminate when charging is Enabled and will be extinguished if charging is Disabled. The bottom cover must be removed to access switch S1. (Continued on page 10...) 2000-16-3624 Manual_Rev.0 Page 9 09/17/15

2.3 Installation / Operation, (continued from page 9) 12. The maximum total charge current of the Power Supply/Charger is 8 Amps. In the event that multiple highly discharged batteries are installed and the total desired charging current is greater than 8 Amps, the charger will disable charging on one or more batteries as needed (beginning with D, then C etc.) to keep the charge current below 8 Amps. Charging of the disabled batteries will resume when the power load on the charger allows. 2.4 Alarm Indications TABLE 2.0 2000-16-3624 Power Supply/ Charger Alarm States Primary Alarm Indications TABLE 2.0 +24VDC 2000-16-3624 Voltage and/or Power Current Supply/ Alarm Charger Alarm Alarm LED States and +24V LED Flash Simultaneously +12VDC Voltage and/or Current Alarm Alarm LED and +12V LED Flash Simultaneously Charging Voltage and/or Current Alarm Over Temperature Alarm (Charging Disabled) Thermal Shutdown (All Outputs Disabled) Alarm Flashes twice then pauses (repeats) Alarm Flashes three times then pauses (repeats) Alarm Flashes Continuously 2.5 Connector - Side panel, DB-9 female TABLE 2.1 +12VDC DB-9 Connector Pinouts Pin 1 2 3 4 5 6 7 8 9 Function No Connection No Connection No Connection +12VDC +12VDC No Connection No Connection Ground (+12VDC Return) Ground (+12VDC Return) 2000-16-3624 Manual_Rev.0 Page 10 09/17/15

3.0 Environmental Use Information A. Reduced Air Flow - Installation of the equipment in an enclosure that limits airflow and therefore convection cooling will cause the unit to thermally shutdown. The power supply/charger is designed to be operated at elevated temperatures but must be installed so that air can move in and around its enclosure. B. Circuit Overloading - Consideration should be given to the connection of the equipment to the output devices and the effect that overloading of these circuits could have on over current protection and supply wiring. The +24V and +12V DC outputs are protected with a resettable PTC fuses. Should one or both of these outputs show a fault condition, remove the output connection(s) and reconnect. If the fault clears and then reoccurs, check the wiring on the output for shorts, etc. C. Bottom Cover - The Power Supply/Charger has the option to disable charging of one or more batteries. The interior motherboard contains a four position slide switch (S1) allowing charging to be disabled to one of more batteries (A-D). Onboard LEDs illuminate when charging is Enabled and will be extinguished if charging is Disabled. If the Bottom Cover is removed make sure to tightly reinstall all screws. No user serviceable parts inside. 2000-16-3624 Manual_Rev.0 Page 11 09/17/15

CROSS TECHNOLOGIES, INC. 6170 Shiloh Road Alpharetta, Georgia 30005 Printed in USA 2000-16-3624 Manual_Rev.0 Page 12 09/17/15