Olson Electronics Remote Power Switching PDU

Similar documents
Olson Electronics Remote Power Monitoring Meter

Network Power Manager. User Manual

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

Easy Setup Guide for the Sony Network Camera

Chapter 1 Introduction

Port forwarding and viewing your IP camera from the internet

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo

3.5 EXTERNAL NETWORK HDD. User s Manual

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed:

Debugging Network Communications. 1 Check the Network Cabling

Installation Steps Follow these steps to install the network camera on your local network (LAN):

Gigabit Content Security Router CS-5800

Internet Telephony PBX system IPX-1980

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

User Manual. EtherUSB

EDGE FX Network configuration

Prestige 660R-6x Read Me First

Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches

Power Supply SNMP Interface User Manual for SRL versions

Ethernet Connection Setup for CCU

Connecting the DG-102S VoIP Gateway to your network

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

HWg-STE HWg-STE PoE MANUAL

Hills Professional Series NVRs and Cameras

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

IP BOOT MANAGER 9280 USERS MANUAL. IP Boot Manager 9280 User Manual

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

UPS Network Interface. Quick InstallationGuide

Quick Installation Guide DAP Wireless N 300 Access Point & Router

Cisco SPA Phones User Guide Bicom Systems

MULTIFUNCTIONAL DIGITAL SYSTEMS. TopAccess Guide

Quick Installation Guide DSL-2750U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

BiPAC 7404V series. VoIP/(802.11g) ADSL2+ (VPN) Firewall Router. Quick Start Guide

Ithaca itherm, POSjet & BANKjet Printers Ethernet Adapters Setup Guide

1. Hardware Installation

Quick Start Guide. Cisco Small Business. 200E Series Advanced Smart Switches

P-660R-T1 v3 QUICK START GUIDE. ADSL2+ Access Router DEFAULT LOGIN DETAILS. Firmware v3.40 Edition 1, 09/2008. IP Address:

Quick Installation Guide DSL-2640U. Wireless N 150 ADSL2+ Modem Router

Innovative Electronics for a Changing World INDEX

sensorprobe2 / sensorprobe8/ sensorprobe8-x20 User Manual

SNAP Printer Web Server Users Manual

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I Rev B

Quick Installation Guide

DI-634M. Check Your Package Contents. This product can be set up using any current web browser, i.e., Internet Explorer 6 or Netscape Navigator 7.

Coolmax CN-590 Network Storage Solution

PE6108/PE6208/PE8108/PE8208

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

DSL Installation Guide

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

Quick Installation Guide. Overview. GULFSIP ATA-G1S Quick Installation Guide

1 Serial RS232 to Ethernet Adapter Installation Guide

NXT Controller Manual IP Assignment in WAN Environments Application Note

Prestige 623R-T. Quick Start Guide. ADSL Dual-link Router. Version 3.40

Installation and Operation Guide

Chapter 10 Troubleshooting

2012 uptimedevices.com

Symphony Network Troubleshooting

Prestige 314 Read Me First

Setting up VPN Access for Remote Diagnostics Support

Comtrend 1 Port Router Installation Guide CT-5072T

Quick Installation Guide

NETVIGATOR Wireless Modem Setup Guide. (TG789Pvn)

P-660HWP-Dx. Quick Start Guide g HomePlug AV ADSL2+ Gateway. Version /2007 Edition 1. Copyright All rights reserved.

Web Power Switch III User s Guide Revision LPC-3

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

SATO Network Interface Card Configuration Instructions

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Quick Installation Guide

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Quick Installation Guide Network Management Card

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

Quick Installation Guide of WLAN Broadband Router

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

SOFTWARE UTILITY OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES

Prestige 202H Plus. Quick Start Guide. ISDN Internet Access Router. Version /2004

This section will focus on basic operation of the interface including pan/tilt, video, audio, etc.

OfficeConnect Internet Firewall 25 Internet Firewall DMZ. QuickStart Guide (3C16770, 3C16771)

Multi-Profile CMOS Infrared Network Camera

GV-Data Capture V3 Series User's Manual

Application & Quick-Start Guide

Configuring a customer owned router to function as a switch with Ultra TV

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

Ultra Thin Client TC-401 TC-402. Users s Guide

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

DVQ-2, DMR8RT, DMR16RT QUICK-START GUIDE

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

Internet Telephony PBX System. (30/100 SIP Users registrations) IPX-330 / IPX Quick Installation Guide

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

CCNA Discovery Networking for Homes and Small Businesses Student Packet Tracer Lab Manual

801.11n Wireless Broadband Router

User Manual. EtherUSB

Troubleshooting Guide

TL-PS310U Single USB 2.0 Port MFP and Storage Server

2M IR Mini Dome Quick Installation Guide

Quick Setup Guide High Power Wireless Ethernet Converter WLI-TX4-G54HP

DSA-1000 / PRT-1000 Device Server / Thermal Printer

Business Broadband Kit Quick Installation Guide

Aolynk DR814Q ADSL2+ Broadband Router Quick Start

Transcription:

Olson Electronics Remote Power Switching PDU Operation Guide Switching Key Features Each socket can be remotely controlled, ON/OFF/CYCLE With the cycle command, outputs are automatically powered down for 10 seconds, and then powered back on. This means that even networking equipment controlling the PDU can be reset remotely. Overall rating 32A with the output rating of the switching relay is 16A (though the socket may not be rated at this level). At power on, each socket can returns to the previous state i.e. the output state is retained when switched off. At power on, each socket can be individually programmed to have a delayed (sequential) start, within the range 0 secs to 25.5 secs. Monitoring Key Features Amps: 00.00 to 32.00A True RMS (rated short period to 40A) Volts: 200.0 to 250.0V True RMS Watts: 0000 to 9999W KWh: 000000.0 to 999999.9 KWh (approx 15 years @ full 32A load before roll-over) Power Factor:.00 to.99 (Cos) Temperature 00.0 to 95.0 C (internal to the PDU only) Technical Specification Supply Voltage 200-250VAC 50/60Hz Maximum Overall Rating 32A continuous, individual outputs 16A continuous Accuracy Better than 1% 4 digit 14mm high LED local display RJ45 10baseT Ethernet connectivity SNMP support for all socket outputs, display values and configuration parameters IP Address Configurable, static and dynamic via DHCP client Each unit can be given a real world name for easy identification Page 1 of 7

Operation Guide The Remote Power Monitoring PDU can be configured by any network enabled PC with a web browser. No CD or programs are required to configure the PDU. The unit comes with a default IP address of 192.168.0.30 and DHCP turned OFF. You can connect the PDU to an existing network via a standard RJ45 patch panel if connecting via a switch or hub. Alternatively you can connect directly to a PC with a cross over RJ45 patch panel. The setup is slightly different depending if a DHCP server is available. PDU Connected to a DHCP Server Connect the unit to the mains and to the network Next turn DHCP ON from the local push button switch and display as follows: o Repeatedly press the push button switch until the display shows IP and then release. See below for full details of Operation of the Local Display o After a 2 second delay it should display the current IP address. o When it is displaying the current IP address, press and hold the push button switch until SET is displayed. o Release the switch and it should display ON i.e. DHCP ON o If it displays OFF then you have just turned DHCP OFF! In this case repeat the above procedure, DHCP is toggled ON/OFF by this procedure. Once DHCP is enabled it can take up to a minute to find the DHCP server and get it s address. If no DHCP server is found then the default IP address continues to be used. PDU Connected Directly to a PC with Crossover Cable. The PC will need to have a static IP address on the same subnet as the PDU eg if the PDU has its factory IP address 192.168.0.30 then the PC will need an IP address in the 192.168.0.xxx range. Displaying the Units IP Address The PDU IP address can be found either by the local LED display or via the DHCP server diagnostics/log if a DHCP server is being used. To display the IP address locally, repeatedly press the push button switch to scroll through the various parameters until IP is displayed. The IP address should be displayed after 2 seconds after you release the switch. It will repeatedly scroll through the 4 IP address octets. See the Local Display section for full details of operating the local display. Page 2 of 7

Connecting to the PDU with a Web Browser NOTE. You may have to either configure or temporarily disable any firewall present to allow the web browser to connect to the PDU. Once the units IP address is known, you can connect via any popular web browser. Put http://xxx.xxx.xxx.xxx in the url address bar where xxx.xxx.xxx.xxx is the PDU IP address. In all the examples the IP address has been set to 10.1.0.8 The unit has been tested with all popular web browsers running under Windows TM, *nix and Apple OS including Internet Explorer 4.0 upwards, Firefox 1.0 upwards (and other Gecko based browsers), Opera 4.0 upwards, Safari 1.0 upwards, Galeon 1.0 upwards and Konqueror 2.0 upwards. It should work with all other standards compliant Web Browsers. If the web browser does not display a page you can ping the unit to check for network connectivity. If the PDU is not correctly connected then check the network settings, firewall settings etc. It may help to ping a known working IP address of say a server, router or other network device. Page 3 of 7

The Remote Web Interface Home Page of the PDU The Home Page of the PDU displays a snapshot of the various power parameters and is not automatically updated. To get the various power parameters continuously updated click on the Auto Update On icon. The page will then automatically refresh every 10 seconds. This update time is user adjustable and can be set from the Setup page. Page 4 of 7

The Socket Switching Page Each socket outlet can be controlled from the Output Settings page The outputs can be set to ON 1 or OFF 0 via the drop down selection in the Settings when the submit button is pressed. This can be used to power up or down a socket at any time. The Pwr (power) On State determines what happens when the unit is powered up. It can be set to ON 1 or OFF 0 or PREVIOUS P via the drop down selection. It option only becomes active once the submit button is pressed. It is envisaged that it would normally be set to previous unless there was some operational reason why equipment always had to be on or off at power up. The Pwr (power) On Timer setting allows each socket to be individually programmed to have a delayed (sequential) start, within the range 0 x 100mS (immediate on) to 255 x 100mS (25.5 secs). Note 100mS = 0.1 seconds All outputs can also be cycled On -> Off (for 10 seconds) -> On via the relevant cycle icon. There is no need to use the submit button, the action is immediate. Care must be taken to ensure that the recycle icon is not pressed when adjusting the power on timer (sequential). Output Setting Page Page 5 of 7

The Setup Page The Setup page is accessed from the Setup icon on the home page. It is password protected with factory default username and password both being olson From the setup page various parameters can be adjusted As we have a policy of continuously updating our products, you may receive a unit with a higher firmware revision number. SNMP PDU Configuration Page The PDU can be used with most SNMP management and monitoring programs. To assist in setting up SNMP programs there is a MIB file on our website. SNMP traps are not yet implemented. It is hoped these will shortly be incorporated into a firmware update. Page 6 of 7

Firmware Updates When firmware updates are available they will be posted on our website together with instructions on how to perform the update. The firmware update is performed via the network and so can be done remotely. At present the update utility software only runs on Microsoft Windows PC s Operation of the Local Display When booting it will illuminate the decimal points, right to left, while carrying out a self-diagnostic check. It will then display Olson Electronics while continuing it s self-diagnostic check and energising the sockets. It will then display the firmware version number for 2 seconds It will then display the last parameter it was displaying when powered down. You can scroll through the different parameters by the push button switch. Below is the order of displayed parameters. Pressing the switch immediately displays the header/description. The actual value is displayed after a 2 second delay from releasing the push button. You can toggle DHCP ON and OFF from the local push button switch o Repeatedly press the push button switch until the display shows IP and then release. o After a 2 second delay it should display the current IP address. o When it is displaying the current IP address, press and hold the push button switch until SET is displayed. o Release the switch and it should display ON or OFF You can force all socket outputs ON from the local display o Repeatedly press the push button switch until the display shows VOLT and then release. o After a 2 second delay it should display the current voltage. o When it is displaying the current voltage, press and hold the push button switch until the SOCKETS ON message is displayed. o Resetting the KWh Counter The KWh value is stored in E 2 PROM memory and will be retained for up to 100 years with the unit powered down. It is not possible for the user to reset the KWh meter. It can only be reset by returning it to the factory. Page 7 of 7