National Food Safety Standard

Similar documents
Graphite Furnace AA, Page 1 DETERMINATION OF METALS IN FOOD SAMPLES BY GRAPHITE FURNACE ATOMIC ABSORPTION SPECTROSCOPY (VERSION 1.

HS 1003 Part 2 HS 1003 Heavy Metals Test

UNITED STATES CONSUMER PRODUCT SAFETY COMMISSION DIRECTORATE FOR LABORATORY SCIENCES DIVISION OF CHEMISTRY 5 RESEARCH PLACE ROCKVILLE, MD 20850

SODIUM CARBOXYMETHYL CELLULOSE

Solutions and Dilutions

University of Wisconsin Chemistry 524 Spectroscopic Applications (GFAA, ICP, UV/Vis, Fluorescence)

Determination of Metals in a 3% Sodium Chloride (NaCl) Matrix by Axially-Viewed ICP-OES

ZINC ACETATE Draft proposal for The International Pharmacopoeia (August 2012)

OXIDATION-REDUCTION TITRATIONS-Permanganometry

IB Chemistry. DP Chemistry Review

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Experiment 12- Classification of Matter Experiment

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Determination of the Mass Percentage of Copper in a Penny. Introduction

XI. Methods of Analysis DETERMINATION OF POTASSIUM CARBONATE CALCULATIONS REAGENTS PROCEDURE

ATOMIC ABSORTION SPECTROSCOPY: rev. 4/2011 ANALYSIS OF COPPER IN FOOD AND VITAMINS

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

Phosphorus, colorimetry, phosphomolybdate, automated-segmented flow

Determining the Quantity of Iron in a Vitamin Tablet. Evaluation copy

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

Chapter 16: Tests for ions and gases

To determine the mass of iron in one adult dose of either a ferrous sulfate or. ferrous gluconate iron supplement using a colorimetric technique.

Colorimetric Determination of Iron in Vitamin Tablets

Calculation of Molar Masses. Molar Mass. Solutions. Solutions

2. ATOMIC, MOLECULAR AND EQUIVALENT MASSES

Standard Test Method for Analysis of Barium, Calcium, Magnesium, and Zinc in Unused Lubricating Oils by Atomic Absorption Spectrometry 1

NITRIC OXIDE and NITROGEN DIOXIDE 6014

Experiment 5. Chemical Reactions A + X AX AX A + X A + BX AX + B AZ + BX AX + BZ

Elemental Analyses by ICP-AES

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

Analysis of Vitamin C Using Iodine. Introduction

Summer Holidays Questions

OLIVÉR BÁNHIDI 1. Introduction

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

Unit 6 The Mole Concept

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

POLYDIMETHYLSILOXANE

Apparatus error for each piece of equipment = 100 x margin of error quantity measured

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Mixtures and Pure Substances

Carolina s Solution Preparation Manual

HOMEWORK 4A. Definitions. Oxidation-Reduction Reactions. Questions

DETERMINING THE ENTHALPY OF FORMATION OF CaCO 3

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

CHEMICAL REACTIONS OF COPPER AND PERCENT YIELD KEY

General Chemistry Lab Experiment 6 Types of Chemical Reaction

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

EXPERIMENT 12: Empirical Formula of a Compound

3 - Atomic Absorption Spectroscopy

EXPERIMENT 4. Determination of Sodium by Flame Atomic-Emission Spectroscopy

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

Determination of calcium by Standardized EDTA Solution

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

Complexometric Titrations

EXTRACTION OF METALS

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Potentiometric determination. Application Bulletin 125/3 e. Branch General analytical laboratories; water analysis; beverages

LAB 5 - PLANT NUTRITION. Chemical Ionic forms Approximate dry Element symbol Atomic weight Absorbed by plants tissue concentration

Additional Lecture: TITRATION BASICS

Coordination Compounds with Copper (II) Prelab (Week 2)

INTERNATIONAL OLIVE COUNCIL

WHAT IS IN FERTILIZER OTHER THAN NUTRIENTS?

NUTC R304. Use of Absorption Mechanisms to Decrease Heavy Metal Mobility

Experiment 8 - Double Displacement Reactions

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Solids, Volatile Dissolved and Fixed Dissolved

Topic 4 National Chemistry Summary Notes. Formulae, Equations, Balancing Equations and The Mole

W1 WORKSHOP ON STOICHIOMETRY

Accurate Determination of Lead in Different Dairy Products by Graphite Furnace Atomic Absorption Spectrometry

Formulae, stoichiometry and the mole concept

Calcium Analysis by EDTA Titration

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Measuring Manganese Concentration Using Spectrophotometry

Chemistry Post-Enrolment Worksheet

Physical Changes and Chemical Reactions

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

General Chemistry I (FC, 09-10) Lab #3: The Empirical Formula of a Compound. Introduction

North East Regional Heat Schools Analyst Competition Coral in Distress

Question Bank Electrolysis

Stoichiometry Review

MOISTURE (Karl Fischer, Buffered)

Laboratory Procedure Manual

Complexometric Titration Analysis of Ca 2+ and Mg 2+ in seawater

Concept 1. The meaning and usefulness of the mole. The mole (or mol) represents a certain number of objects.

Determining The Properties of Colloidal Silver

Halogen Free: What, Why and How. Presented by : Jim Cronin Environmental Monitoring and Technologies, Inc.

Balancing chemical equations

Lab 2 Biochemistry. Learning Objectives. Introduction. Lipid Structure and Role in Food. The lab has the following learning objectives.

MOLES AND MOLE CALCULATIONS

PECTINS. SYNONYMS INS No. 440 DEFINITION DESCRIPTION. FUNCTIONAL USES Gelling agent, thickener, stabilizer, emulsifier CHARACTERISTICS

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

Chemistry: Chemical Equations

VALIDATION REPORT. Investigation of the major interferences for proposed Horizontal ICP AES method. ECN protocol

Name: Unit 2- Elements, Compounds and Mixtures and Physical/Chemical Properties and Changes. Elements, Compounds and Mixtures

Spectrometric Oil Analysis An Untapped Resource for Condition Monitoring

Decomposition. Composition

Experiment 9 Electrochemistry I Galvanic Cell

EXPERIMENT 8: Activity Series (Single Displacement Reactions)

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

Transcription:

National standard of People s Republic of China GB 5413.21 2010 National Food Safety Standard Determination of calcium, iron, zinc, sodium, potassium, magnesium, copper and manganese in foods for infants and young children, raw milk and dairy products Issued at 2010-03-26 Implemented 2010-06-01 Issued by the Ministry of Health, People s Republic of China

Preface This standard replace GB/T5413.21-1997, Measurement of calcium, ferrum, zinc, sodium, potassium, magnesium, copper and manganese in formulated foods and milk powder for infants and young children The main changes in this standard compared with GB 5413.21-1997 are as following: --Certified reference stock can be directly purchased in method 1 --The preparation standard stock solution and standard working solution in method 1 --The dilution steps for sample preparation in method 1. --Add the second measurement method of inductively coupled plasma atomic emission spectrometry. Versions of standard substituted by this standard are: --GB 5413-1985 GB/T 5413.21-1997.

GB Determination of calcium, ferrum, zinc, sodium, potassium, magnesium, copper and manganese in food for infants and young children and dairy products 1 Scope This standard regulate the method for the determination of calcium, ferrum, zinc, sodium, potassium, magnesium, copper and manganese in food for infants and young children and dairy products. This standard applies to the determination of calcium, ferrum, zinc, sodium, potassium, magnesium, copper and manganese in food for infants and young children and dairy products. 2 Normative cited documents The reference cited in this standard is necessary. For the cited documents which are labeled with date, all their subsequent modification sheets or modified versions are not applicable for this standard. For the cited documents which are not labeled with date, their latest versions are applicable for this standard. 3 Principle Method 1 Atomic absorption spectrometry Dry ash the samples to break down organic part. Dissolve the inorganic ions in the ash by acid. Aspirate into air-acetylene flame for atomization. Measure absorbance under specific wavelength. When measuring calcium and magnesium, lanthanum should be added as releasing agent to eliminate the interference by phosphoric acid. 4 Reagents and materials Unless additionally specified, the reagents used by this method are GR, and water is the second grade water specified by GB/T6682. 4.1 Hydrochloric acid 4.2 Nitric Acid 4.3 Lanthanum solution 4.4 Potassium chloride, molecular weight: 74.55, chromatography grade 4.5 Sodium chloride, molecular weight: 58.44, chromatography grade 4.6 Calcium carbohydrate: molecular weight: 100.05, chromatography grade 4.7 Purified magnesium, chromatography grade 4.8 Purified zinc, chromatography grade 4.9 Iron powder, chromatography grade 4.10 copper, chromatography grade 4.11 Manganese, chromatography grade 4.12 Hydrochloric acid A(2%): Dilute hydrochloric acid 2ml (4.1) to 100 ml with water. 4.13 Hydrochloric acid B(20%): Dilute hydrochloric acid 20 (4.1) to 100 with water. 4.14 Nitric acid (50%): Dilute 20 nitric acid (4.2) to 100 with water. 4.15 Lanthanum solution (50g/L): weigh 29.32g lanthanum oxide (4.3) and wet with 25 deionized water. Slowly add 125 hydrochloric acid (4.1) and dissolve the lanthanum oxide. Dilute with deionized water to 500. 4.16 Potassium standard stock solution (1000 ): Weigh 1.9067g of dried potassium chloride (4.4), Dissolve in hydrochloric acid A (4.12) and dilute to 1000 ml in volumetric flask. 4.17 Sodium standard stock solution (1000 ): Weigh 2.5420g dried sodium chloride (4.5)

Dissolve in hydrochloric acid A (4.12) and diluted to 1000 in volumetric flask. 4.18 Calcium standard stock solution (1000 ): Weigh 2.4963g dried sodium chloride (4.6) Dissolve in 100 ml hydrochloric acid B (4.13) and diluted to 1000 in volumetric flask. 4.19 Magnesium standard stock solution (1000 ): Weigh 1.0000g purified magnesium (4.7) Dissolve in 40 ml nitric acid (4.14) and diluted to 1000 in volumetric flask. 4.20 Zinc standard stock solution (1000 ): Weigh 1.0000g purified zinc (4.8).Dissolve in 40 ml nitric acid (4.12) and diluted to 1000 in volumetric flask. 4.21 Iron standard stock solution (1000 ): Weigh 1.0000g iron powder (4.9).Dissolve in 40 ml nitric acid (4.12) and diluted to 1000 in volumetric flask. 4.22 Copper standard stock solution (1000 ): Weigh 1.0000g copper (4.10).Dissolve in 40 ml nitric acid (4.12) and diluted to 1000 in volumetric flask. 4.23 Manganese standard stock solution (1000 ): Weigh 1.0000g manganese (4.11).Dissolve in 40 ml nitric acid (4.12) and diluted to 1000 in volumetric flask. 4.14 Standard stock solutions of different elements Standard stock solutions of calcium, iron, zinc, sodium, potassium and magnesium: pipette 10.0 standard solution of calcium(4.18), iron (4.21), zinc (4.20) and potassium (4.16), 5.0 standard solution of sodium (4.17) and 1.0 magnesium standard solution (4.19) into 100 quartz volumetric flask and make up to the mark with hydrochloride acid solution A (4.12) to obtain the standard stock solution of the above different elements. Concentration for calcium, iron, zinc, potassium is 100.0µg/; sodium: 50.0µg/; magnesium:10.0µg/ Standard stock solutions of manganese and copper: accurately Pipette 10.0 manganese standard solution (4.23) into 100 ml volumetric flask and make up to the mark with hydrochloric acid A(4.12), from which 4.0 is diluted with hydrochloric acid A (4.12) to 100 to obtain manganese stock solution. Accurately pipette 10.0 copper standard stock solution (4.22) into 100 ml volumetric flask and make up to the mark with hydrochloric acid A(4.12), from which 6.0 is diluted with hydrochloric acid A (4.12) to 100 to obtain copper stock solution.concentration is: manganece: 4.0µg/; copper: 6.0µg/. 5 Equipments and devices: 5.1 Atomic absorption spectrometer 5.2 Hollow cathode lamps of calcium, iron, zinc, sodium, potassium, magnesium, copper and manganese 5.3 Acetylene gas and air compressing engine 5.4 Quartz crucible or porcelain crucible 5.5 Muffule furnace 5.6 Balance: nearest to 0.1mg.

6 Analysis steps 6.1 Sample preparation Approximately weigh 5g of well-mixed solid sample or 15g (nearest to 0.0001g) in crucible (5.4) and carbonize on electric furnace with low powder until no black smoke. Heat in Muffule furnace (5.5) under 490 until the sample becomes white ash. If there are any black carbon granules, add drops of nitric acid (4.14) after cooling down. Evaporate on the electric furnace using low power and put into 490 muffule furnace again to be incinerated to white ash. After sample is cooled to room temperature, add 5 hydrochloric acid B(4.13), heat on the electric furnace to make the ash thoroughly dissolved. The sample is cooled down to room temperature and moved to 50 volumetric flask and make up to the mark with water. At the same time, at least two blank control is prepared at the same time. 6.2 Testing solution preparation of samples 6.2.1 Ca, Mg testing solution Pipette 1.0 ml accurately from 50 solution (6.1) into 100 ml volumetric flask. Add 2 ml Lanthanum solution (4.15). Make up to the mark with water. Same operation to blank solution 6.2.2 Na testing solution Pipette 1.0 ml accurately from 50 solution (6.1) into 100 ml volumetric flask. Make up to the mark with hydrochloride acid solution A (4.12). Same operation to blank solution 6.2.3 K testing solution Pipette 1.0 ml accurately from 50 solution (6.1) into 100 ml volumetric flask. Make up to the mark with hydrochloride acid solution A (4.12). Same operation to blank solution 6.2.4 Testing solution for Fe, Zn, Mn and Cu 50 ml solution (6.1) directly aspirate to the AAS. At the same time blank control solution is measured. 6.2.5 In order to make sure concentration of testing solution fall into the range of standard curve, dilution volume can be adjusted. 6.3 Determination 6.3.1 Preparation of standard curve 6.3.1.1 Preparation of standard series dilutions According to the volume listed in table 1, pipette standard stock solutions of iron, zinc, sodium, potassium, manganece and copper into 100 volumetric flask. Make up to the mark with hydrochloric acid (4.12). Pipette accurately standard stock solution of Ca and Mg into volumetric flasks and make up to the mark with water. The standard working solutions of different concentrations for different elements are prepared, concentrations are listed in table 2. Table 1 Volume of standard intermediate solutions for different elements required for the preparation of standard series dilutions Number K Ca Na Mg Zn Fe Cu Mn 1 1.0 2.0 2.0 2.0 2.0 2.0 2.0 2.0 2 2.0 4.0 4.0 4.0 4.0 4.0 4.0 4.0 3 3.0 6.0 6.0 6.0 6.0 6.0 6.0 6.0 4 4.0 8.0 8.0 8.0 8.0 8.0 8.0 8.0 5 5.0 10.0 10.0 10.0 10.0 10.0 10.0 10.0

Table 2 Concentrations of standard series dilutions for different elements Number K Ca Na Mg Zn Fe Cu µg/ Mn 1 1.0 2.0 1.0 0.2 2.0 2.0 0.12 0.08 2 2.0 4.0 2.0 0.4 4.0 4.0 0.24 0.16 3 3.0 6.0 3.0 0.6 6.0 6.0 0.36 0.24 4 4.0 8.0 4.0 0.8 8.0 8.0 0.48 0.32 5 5.0 10.0 5.0 1.0 10.0 10.0 0.60 0.40 6.3.1.2 Plotstandard curve Optimize working condition of equipment according to the equipment manual Select the sensitive absorption lines K 766.5nm Ca422.7nm Na589.0nm Mg285.2nm Fe248.3nm Cu324.7nm Mn279.5nm Zn213.9nm. After the equipment is adjusted, set zero point with hydrochloric acid (4.2) aspirated with capillary tube for measurement of iron, zinc, sodium, potassium, copper and manganese.when measuring calcium and magnesium, first pipette 2.0 lanthanum solution (4.15) and diluted to 100 with water. This solution is used to set zero point through capillary tube. Measure absorbance of standard working solution. Plot the Standard curve using concentrations of standard series solution as X-axis and corresponding absorbance as Y-axis. 6.3.2 Determination of sample solutions Optimize working condition of equipment, hydrochloric acid (4.2) is used for zeroing in the measurement of iron, zinc, sodium, potassium, copper and manganese. In the measurement of calcium and magnesium, 2.0 lanthanum solution (4.15) is diluted to 100 with water to make the solution for zeroing. Absorbance of sample solution and blank solution is measured according to the following steps. Corresponding mass concentration is obtained from standard curve. 7 Result expression The content of calcium, magnesium, sodium, potassium, iron and zinc (X) is expressed as mg/100g, and calculated using equation (1): In the equation: X content of elements in the samples, mg/100g; C1 concentration of elements in the samples, µg/; C2 concentration of elements in the blank solution, µg/; V volume of the sample solution, ; A dilution times of the sample solutions; m mass of the samples, g. The content of calcium, magnesium, sodium, potassium, iron and zinc (X) in the samples is expressed as mg/100g, and calculated using equation (2): In the equation:

X content of elements in the samples,µg/100g; C1 concentration of elements in the samples, µg/; C2 concentration of elements in the blank solution,µg/; V volume of the sample solution, ; A dilution times of the sample solutions; m mass of the samples, g. The result is expressed as the arithmetic mean value of two independent measurements. The calculation results of calcium, magnesium, sodium, potassium, manganese and copper need to be accurate to one digit after the decimal point. For iron and zinc, the result is required to be accurate to two digits after the decimal point. 8 Precision The absolute difference between two independent measurements performed under repeatability conditions should not exceed 15% of the arithmetic mean value. The second measurement method of inductively coupled plasma atomic emission spectrometry 9 Principle Sample is incinerated and digested using dry method, and measured with inductively coupled plasma atomic emission spectrometry after diluted to appropriate volume. External reference method is used for quantification. 10 Reagents and materials Unless additionally specified, the reagents used by this method are GR, and water is the first grade water specified by GB/T6682. 10.1 Hydrochloride acid 10.2 Nitric acid solution 10.3 Nitric acid solution (50%): dilute 50 ml (10.2) nitric acid to 100 ml with water. 10.4 Hydrochloric acid solution A (4%): dilute 4 ml (10.1) nitric acid to 100 ml with water. 10.5 Hydrochloric acid solution B(40%): dilute 40 ml (10.1) nitric acid to 100 ml with water. 10.6 Standard stock solution of 8 elements: Standard stock solution of single element can be prepared using method specified in GB/T602 or using certified reference material.concentration is 1.0 mg/ (or 0.5 mg/). 11 Equipments and devices: 11.1 Inductively coupled plasma atomic emission spectrometry 11.2 Analytic balance: accuracy is 1mg. 11.3 Muffle furnace 11.4 Electric furnace:1~2 kw. 11.5 Porcelain crucible 12 Analysis Procedure 12.1 Sample preparation If Samples are powder and should be mixed well before analysis. If samples are granules with bigger size, then some samples should be crashed or grinded before measurement. 12.2 Sample preparation Weigh 5g samples (nearest to 1mg) into porcelain crucible and carbonize on electric furnace using low power until no smoke can be seen. Ash in muffule furnace at 550 for 2 hours. If there are any black carbon granules, drops of nitric acid (10.1) is added after cooling down. Evaporate on the electric furnace using low power and ash in muffle furnace at 490 for 0.5 hour. Cool down and add 5 ml of Hydrochloric acid solution B (10.5) Heat on the electric furnace to completely dissolve the ashes. After cooling down, the sample is moved to 25

volumetric flask and make up to the mark with water. If there are any precipitates, the solution should be filtered. 12.3 Parallel experiment The same sample is measured in parallel according to the above steps. 12.4 Blank experiment Only no sample is added, all other steps are carried out according to the sample processing and measurement steps. 12.5 Reference operation condition of equipments Power: 1.20 kw, Plasma gas flow rate: 15L/min, Pressure of the atomizer: 200kPa, Assistant gas flow rate: 1.50L/min, Stable time lag: 15s, Sample injection time lag: 20s, Frequency of reading: 3 times, Recommended analytical spectral lines of elements are listed in table 1: Table 1 Recommended analytical spectral lines of elements Unit is nanometer Element Wavelength of analytical spectral lines Ca 315.887, 317.933 Mg 279.553,280.270 Fe 234.350,238.204,259.940 Mn 257.610 Cu 324.754,327.395 Zn 202.548,206.200 K 766.491 Na 588.995,589.592 12.6 Preparation of mixed standard solution Mixed standard solutions, whose concentrations are listed in the following table, is prepared from stock solution after series dilution with hydrochloric acid solution A (10.4). Table 4 Element concentrations of mixed standard solution Serial number Ca Mg Fe Mn Cu Zn K Na 1 0 0 0 0 0 0 0 0 2 10.0 0.5 5.0 0.1 0.2 5.0 10.0 1.0 3 15.0 1.0 10.0 0.2 0.4 10.0 20.0 3.0 4 20.0 1.5 15.0 0.3 0.6 15.0 30.0 5.0 5 25.0 2.0 20.0 0.4 0.8 20.0 40.0 7.0 12.7 Determination Optimize the Equipment with reference to condition listed in 12.5. Measure standard solution, blank solution and samples in turn. If concentration of certain element exceeded the standard curve, sample solution can be measured after diluted with hydrochloric acid solutiona (10.4). 13 Result expression Element content is calculated according to equation (3): In the equation X content of elements in the samples, mg/100g; C1 concentration of elements in the samples, µg/; C2 concentration of elements in the samples, µg/; V volume of the sample solution, ; A dilution times of the sample solutions; m mass of the samples, g.

The result is expressed as the arithmetic mean value of two independent measurements. Report results to 3 effective digit 14 Precision The absolute difference between two independent measurements performed under repeatability conditions should not exceed 10% of the arithmetic mean value. 15 Others Detection limit for Method I Ca: 1.0 mg/100g, Mg: 0.3mg/100g, Fe: 0.02mg/100g, Mn: 0.001mg/100g, Cu: 0.0045mg/100g, Zn: 0.02mg/100g, K:0.2mg/100g, Na: 1.5mg/100g Detection limit for Method II Ca: 0.7 mg/100g, Mg: 0.2mg/100g, Fe: 0.003mg/100g, Mn: 0.005mg/100g, Cu: 0.002mg/100g, Zn: 0.002mg/100g, K:0.7mg/100g, Na: 1.6mg/100g