Processing 2D NMR Data with MestReNova

Similar documents
MestRe-C User Guide Megan Bragg 04/14/05

Introduction to ACD version 12 NMR Software

Creating a Poster in PowerPoint A. Set Up Your Poster

Instructions for Formatting APA Style Papers in Microsoft Word 2010

Creating an invitation

Welcome to CorelDRAW, a comprehensive vector-based drawing and graphic-design program for the graphics professional.

Education Solutions Development, Inc. APECS Navigation: Business Systems Getting Started Reference Guide

Introduction to the TI-Nspire CX

Creating and Using Links and Bookmarks in PDF Documents

Creating an invitation

Epson Brightlink Interactive Board and Pen Training. Step One: Install the Brightlink Easy Interactive Driver

BD CellQuest Pro Software Analysis Tutorial

ACS Version Check Layout Design

Petrel TIPS&TRICKS from SCM

Microsoft Word Quick Reference Guide. Union Institute & University

Creating Fill-able Forms using Acrobat 8.0: Part 1

7.0 BW Budget Formulation Report Tips and Tricks

NMR Spectroscopy in Notre Dame

Google SketchUp Design Exercise 3

Introduction to Autodesk Inventor for F1 in Schools

Tutorial for Tracker and Supporting Software By David Chandler

Hands-On Practice. Using Notebook Software in the Office

Inside Blackboard Collaborate for Moderators

DCAD Website Instruction Manual

If you know exactly how you want your business forms to look and don t mind

DOING MORE WITH WORD: MICROSOFT OFFICE 2010

Quick Guide. pdoc Forms Designer. Copyright Topaz Systems Inc. All rights reserved.

TOPSPIN INSTRUCTIONS

LESSON 7: IMPORTING AND VECTORIZING A BITMAP IMAGE

Open icon. The Select Layer To Add dialog opens. Click here to display

WHAT S NEW IN WORD 2010 & HOW TO CUSTOMIZE IT

Graphic Design Studio Guide

Handout: Word 2010 Tips and Shortcuts

Task Card #2 SMART Board: Notebook

SMART Board Tips & Tricks (version 9.0) Getting Started. SMART Tools vs. SMART Notebook software

Introduction to Autodesk Inventor for F1 in Schools

3D Viewer. user's manual _2

Communicate: In Print

Using Excel to find Perimeter, Area & Volume

Wincopy Screen Capture

Making Visio Diagrams Come Alive with Data

MICROSOFT WORD TUTORIAL

Digital Marketing EasyEditor Guide Dynamic

HSQC and HMBC for Topspin

Sage Accountants Business Cloud EasyEditor Quick Start Guide

Creating Forms With Adobe LiveCycle Designer 8.2

Using the Cute Rich-Text Editor

Excel 2007 Basic knowledge

Microsoft PowerPoint 2007

Why Use OneNote? Creating a New Notebook

Longitudinal Relaxation Time (T 1 ) Measurement for 1 H on VnmrJ2.2D (use on Ra, Mut, and Isis)

NMR Processing on PCs outside the NMR laboratory

1. Installing The Monitoring Software

A Tutorial for Chemists: Using Mnova to Process, Analyze and Report 1D and 2D NMR on Your Desktop

Create a Poster Using Publisher

Adobe Digital Signatures in Adobe Acrobat X Pro

GoodReader User Guide. Version 1.0 GoodReader version

Protocol for Microscope Calibration

NIS-Elements Viewer. User's Guide

Drip Marketing Campaign Manual

Instructions for Formatting MLA Style Papers in Microsoft Word 2010

CorelDRAW X5 & CorelDRAW X6

Applying a circular load. Immediate and consolidation settlement. Deformed contours. Query points and query lines. Graph query.

paragraph(s). The bottom mark is for all following lines in that paragraph. The rectangle below the marks moves both marks at the same time.

Introduction to Word 2007

Mimio Interactive. Pad and Bar. Technology Integration Department. Last update: 2/15/2013

Chapter 1. Creating Sketches in. the Sketch Mode-I. Evaluation chapter. Logon to for more details. Learning Objectives

CATIA Basic Concepts TABLE OF CONTENTS

Adobe Illustrator CS5 Part 1: Introduction to Illustrator

CREATE A 3D MOVIE IN DIRECTOR

Kodu Curriculum: Getting Started with Keyboard and Mouse

Lync 2013 FAQ s. How do I keep my Lync conversation window on top of all the other windows on my computer, so I can see it while I work?

Beginners Guide to CQG FX

MET 306. Activity 8a. Mechanism Design Creo 2.0 Level 7 POINT A GROUND LINK LINK 1 LINK 2 LINK 3 POINT B 10/15/2010 1

Geocortex HTML 5 Viewer Manual

Ortelia Space Builder User Manual

How to create pop-up menus

Microsoft Excel 2010 Tutorial

Visual Tutorial Basic Edition 1. Visual. Basic Edition Tutorial.

Adobe InDesign Creative Cloud

PowerPoint 2007 Lesson 1: Getting Started

Basic Pivot Tables. To begin your pivot table, choose Data, Pivot Table and Pivot Chart Report. 1 of 18

Gestation Period as a function of Lifespan

User Guide. emoney for Outlook

DWGSee Professional User Guide

Boardmaker Plus Basics

SMART Sympodium and Notebook Software 9.5

Table Of Contents. iii

Mapping with CMap Software Jamie Armstrong

SketchUp Instructions

How To Write A Cq5 Authoring Manual On An Ubuntu Cq (Windows) (Windows 5) (Mac) (Apple) (Amd) (Powerbook) (Html) (Web) (Font

Instructions for Creating a Poster for Arts and Humanities Research Day Using PowerPoint

New Features in Microsoft Office 2007

LYON COUNTY GEOMOOSE 2 HELP DOCUMENT

Using PowerPoint To Create Art History Presentations For Macintosh computers running OSX with Microsoft Office 2008

5. Tutorial. Starting FlashCut CNC

Using Microsoft Word. Working With Objects

If you know exactly how you want your business forms to look and don t mind detail

To Begin Customize Office

Florence School District #1

Transcription:

Processing 2D NMR Data with MestReNova 1. Open the 2D Data File. On your PC or Mac you can rename the Bruker Experiment Number folder (1, 2, 3 ) to HSQC, COSY, HMBC, ROESY, etc. before dragging it into MestReNova. Drag this folder into the main window of MestReNova. For Varian data just drag the filename.fid folder into the MestReNova window. 2. Set Up Data Processing Method. These parameters control the peak shape and resolution in both dimensions, and different values are required depending on the type of 2D spectrum. Click on the drop-down menu Processing and select Processing Template. With the f2 tab highlighted, Click on the button to the right and just below Apodization. Set the window function in F 2 as follows: COSY: Sine Bell, 0.00 Deg HSQC or TOCSY: Sine Bell, 45.00 Deg HMBC, ROESY or NOESY: Sine Bell, 90.00 Deg (45.00 Deg if S/N is good) Be sure to turn off (uncheck) any other Apodization settings besides Sine Bell. Click OK. Click on the next button down, next to Spectrum Size, and set to 2048. Click OK. Click on the f1 tab. Make sure that the Truncate box is NOT checked. Click on the first button ( ) under the Apodization heading, and set the F 1 window function as follows: COSY: Sine Bell, 0.00 Deg HSQC or TOCSY: Sine Bell, 45.00 Deg HMBC (magnitude mode): Sine Square, 0.00 Deg ROESY or NOESY: Sine Bell, 90.00 Deg Be sure to turn off (uncheck) any other Apodization settings besides the one you want (Sine Bell or Sine Square). Click OK. Click on the next button ( ) down, next to Spectrum Size, and set to 1024. Click OK. Click OK on the Processing Template window. It will take a few seconds as it re-processes the 2D data. 3. Choose Contour Display Setup. For consistency, always use red for positive intensities and blue for negative. Right-click on your 2D spectrum and select Properties (near the bottom). Click on 2D (at the left) and select Red-Blue for Palette, Contour for Plotting method, 10 for Number of Positive Contours, 10 for Number of Negative Contours, and 1.100 for Scaling and 8.0 for Line Width. Click on Set as Default and then OK. 4. Open 1D Spectra for Traces. You will want to have a 1D spectrum corresponding to the F 2 dimension nucleus displayed along the top of the 2D rectangle, and another corresponding to the F 1 dimension nucleus displayed along the left side. MestReNova calls these 1D spectra Traces. For a heteronuclear inverse (HSQC or HMBC) spectrum, you will want a 1 H spectrum in the F 2 dimension and a 13 C spectrum for the F 1 dimension. For a homonuclear (COSY, ROESY, NOESY, TOCSY) spectrum you will want a 1 H spectrum in both dimensions.

Very Important: First, set the reference for the 1D spectra before using them as traces. Reference the 1 H spectrum using TMS or the residual solvent (CHCl 3, d 5 -DMSO, etc.) peak, and reference the 13 C spectrum using the solvent peak (CDCl 3, d 6 -DMSO, etc.). These reference values are posted in the NMR labs in tables of solvent and residual solvent shifts for all of the NMR solvents. Right-click just above the top of the 2D display rectangle and select Show Traces with the right mouse button. This will put traces on the top (F 2 trace) and left side (F 1 trace) that are just projections of the 2D data, so the spectra will be broad and ugly. Right-click again on the top trace and select Setup with the right mouse button. Using the left mouse button now, select the 1 H spectrum in the list of Available 1D Spectra (proton spectra have an H at the left) and click on the top green arrow button (under Horizontal Trace). For a COSY spectrum, also click on the bottom green arrow button (under Vertical Trace). For an HSQC or HMBC spectrum, select the 13 C spectrum in the list of Available 1D Spectra (carbon spectra have an C at the left) and click on the bottom green arrow button (under Vertical Trace). When you have selected both traces (Horizontal and Vertical), click OK. Holding the cursor over the top (Horizontal) trace, you can use the mouse wheel to adjust the vertical scale of the 1D proton spectrum. Holding the cursor over the left side (Vertical) trace, you can use the mouse wheel to adjust the vertical scale of the F 1 trace. 5. 2D Phase Correction. For HSQC, this is phase-sensitive data, meaning that positive crosspeaks (red) are for CH and CH 3 groups and negative crosspeaks (blue) are for CH 2 groups. You will need to PHASE CORRECT the data to get these right. There is no need to phase correct 2D COSY or HMBC spectra. Be careful to make minimal changes to phase parameters because you can change the meaning (positive or negative) of the data by making big changes in the phase correction parameters. ROESY and NOESY are also phase sensitive (positive diagonal peaks and negative NOE crosspeaks) as is TOCSY (positive diagonal peaks and positive crosspeaks). Phase errors appear in the HSQC spectrum as streaks coming out of a crosspeak. Errors in the horizontal (F 2 ) dimension are streaks to the left and right of the crosspeak: red on the left and blue on the right, or vice-versa. Errors in the vertical (F 1 ) dimension are streaks above and below the crosspeak: red above and blue below or vice-versa. To correct the errors, click on the drop-down menu at the right of the Phase Correction icon and select Manual Correction. This brings up a phase correction box in the upper left corner. At the top, select f2 to correct the horizontal dimension:. Below this is a blue rectangle with text instructions: Click here and drag mouse up or down. Ignore this for now and go to the slider at the bottom of the Phase Correction box. Move this left and right to position the vertical line on a crosspeak at the right side of the 2D spectrum. This is the pivot peak. Now click and drag up and down GENTLY with the left mouse button on the blue rectangle with text instructions. You will see the phase errors in the horizontal dimension on the pivot peak. Move the mouse up and down to

minimize these phase error streaks around the pivot peak. Now look at another crosspeak, near the left side of the 2D spectrum, and use the right mouse button to click and drag up and down to correct the horizontal phase errors of this crosspeak. To correct the vertical (F 1 ) phase errors, select f1 at the top of the Phase Correction box:. Now use the slider to position the horizontal cursor on a prominent crosspeak near the top of the 2D spectrum. This will be the pivot peak. Click in the blue rectangle using the left mouse button to click and drag up and down to correct the phase errors (streaks above and below) for the pivot peak. Do the same with the right mouse button to minimize the phase errors for a prominent peak near the bottom of the 2D spectrum display. With both dimensions phase-corrected, click on the X in the upper right corner of the Phase Correction box. 6. Expand Region with Crosspeaks. Click on the magnifying glass (+) icon or enter e at the keyboard. Click and drag from lower left to upper right of the region you want to expand. [To return to the full spectrum, Enter f or click on the full spectrum icon ] 7. Contour Plot. The default display is an intensity plot. To get a contour plot, right click on the 2D spectrum and select 2D Plotting Method and Contour Plot in the dropdown menu. Adjust the contour threshold by clicking on the reduce intensity button repeatedly until the least intense crosspeak disappears. Then click on the increase intensity button until this weakest peak is again visible. Setting the threshold reduces the intensity of streaks and artifacts while making sure you don t miss any real crosspeaks. 8. Referencing the 2D Spectrum. You are wasting your time trying to reference the 2D spectrum if you have not first referenced the 1D spectra you have displayed as traces. If you have not done this, go back and reference these 1D spectra (step 4 above) and redisplay the traces (Setup window for traces). The crosspeaks (and diagonal peaks in COSY) will not at first line up with the corresponding peaks in the 1D traces. To fix this, expand a crosspeak that you know should line up with a simple peak in the 1 H spectrum. In a COSY spectrum it should be an unoverlapped diagonal peak; in an HSQC or HMBC it should be a strong methyl crosspeak. Click on the Reference icon and hit the Shift key once to free up the cursor to move continuously without trying to latch onto a crosspeak. Line the vertical crosshair up precisely with a prominent peak in the top 1D proton spectrum, and note the exact value of the first number, the F 2 (proton) chemical shift. HSQC or HMBC (F 2 ): Now put the vertical crosshair in the center of the crosspeak corresponding to the peak you used in the 1D proton (top) spectrum and click the left mouse button. In an HMBC be sure that you are not using a one-bond artifact peak; instead use the intense methyl proton crosspeaks. In the Reference along f2 box, with

the blue f2 button selected, enter the New Shift as the value you noted from the 1D proton spectrum. Click OK and make sure that the crosspeak now aligns perfectly with the 1D proton peak. COSY (F 2 and F 1 ): If you are referencing a COSY spectrum, you can reference both dimensions at the same time by using a diagonal peak. Instead of aligning the vertical cursor with the diagonal peak, place the center circle (intersection of the vertical and horizontal cursors) in the center of the diagonal peak and click the left mouse button. With the blue f2 button selected, enter the precise proton chemical shift from the 1D spectrum in the New Shift box. Then click on the red f1 button and enter the same number in the New Shift box for F 1. Click OK and check to make sure that the 1D proton peak aligns with the diagonal peak in both (horizontal and vertical) dimensions. HSQC and HMBC (F 1 ): After setting the reference in F 2, again click on the Reference icon and hit the Shift key once to free up the cursor to move continuously. Now align the horizontal cursor precisely with a peak in the 13 C spectrum on the left side of the 2D display. Note the exact value of the second number (after the comma), which is the F 1 (carbon) chemical shift. Align the horizontal cursor with the center of the corresponding crosspeak (in an HMBC this can be a one-bond artifact pair for a methyl carbon) and click the left mouse button. Click on the red f1 button and enter the same number in the New Shift box for F 1. Click OK and check to make sure that the 1D carbon peak now aligns with the crosspeak in the vertical dimension. Especially with the 13 C (F 1 ) dimension of HSQC and HMBC, it s easy to reference the wrong crosspeak. Look at the whole spectrum and make sure the most upfield 1D peak corresponds to the most upfield crosspeak, and likewise with the most downfield peak. If all crosspeaks don t align with the 1D spectra, you need to start over with referencing. 9. Plotting. The best way to plot is to save the view as a pdf file. With the desired 2D display highlighted, click on File and Export to PDF, navigate to the correct folder and edit the filename, leaving the pdf extension unchanged. Click OK and then with Current Page selected click OK again. Then you can print from the pdf file to your printer or move the file elsewhere for printing. 10. Analysis. Click on the crosshair icon or enter c at the keyboard. Position the crosshair on a crosspeak and read the 1D peak on the trace at the left and the other 1D peak on the trace at the top. These two 1D peaks are correlated by that crosspeak. For example, for an HSQC, the vertical line points to the 1 H peak in the top trace and the horizontal line points to the 13 C peak in the left side trace. You can also use the crosshair to measure distances, for example to extract J values from the fine structure of a COSY crosspeak. 11. 1D Slices. You can slice the 2D spectrum horizontally or vertically at any position to create a 1D spectrum or slice. Usually this is done in the horizontal (F 2 ) dimension because the resolution is best in this dimension. For example, for a 2D HSQC spectrum a

horizontal (F 2 ) 1D slice would be a proton spectrum of just the protons directly attached to one carbon atom. The resolution will be worse than a 1D proton spectrum, so you won t see small splittings (J < 8 Hz). 2D slices are handled as traces in MestReNova. With the traces displayed on the top and left side of the 2D spectrum, click on the dropdown arrow at the right side of the Show Traces icon:. This icon is located on the left side of the MestReNova frame, near the top. On the drop-down menu, click on Select Traces Graphically. This brings up the crosshair on the 2D spectrum. Position the crosshair on the crosspeak of interest and left-click. The horizontal slice at that position will be displayed above the 2D spectrum and the vertical slice will be displayed on the left side. If you re only interested in the horizontal slice, you can pay attention only to the horizontal line of the crosshair when you click. You can also move the position of the slice up and down in the Setup Traces window. Right-click on the top trace (horizontal trace) above the 2D spectrum and select Setup. In the Setup Traces window, the green check mark is no longer highlighted and instead it says something like Internal Trace #388 of 512 (31.628 ppm) under the Horizontal Trace checkbox. To the right of this is a box with the number:. You can click on the up and down arrows to the right of the number to increase or decrease the number, moving the slice up or down in the 2D spectrum. The Trace shows this slice as you change the number. At any time in this process you can click on the Extract Current Horizontal Trace as New Item icon:. This will take the 1D slice and add it as a 1D spectrum in your Pages at the left of the main display window. This spectrum can them be analyzed to extract coupling constants. To return to using the real 1D spectra (rather than slices) as the traces above and to the left of the 2D spectrum, highlight the 1 H spectrum in the Available 1D Spectra: display and click on the green check box under the Horizontal Trace heading. Do the same for the 13 C spectrum, clicking on the green check box under the Vertical Trace heading. Then click OK.