Microfluidic Electrochemical Sensors

Similar documents
Mitos P-Pump. product datasheet

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Fabrication Challenges for Point-ofcare Diagnostics and Organ-on-chip

Local Heating Attacks on Flash Memory Devices. Dr Sergei Skorobogatov

CRITICAL MATERIALS HANDLING INVUE INTEGRATED FLOW CONTROLLERS NT6510, NT6520

Flow Injection Analysis

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

JUMO tecline HD ph and JUMO tecline HD Rd

Silicon-On-Glass MEMS. Design. Handbook

Miniaturizing Flexible Circuits for use in Medical Electronics. Nate Kreutter 3M

ESRF Upgrade Phase II: le nuove opportunitá per le linee da magnete curvante

Rapid Prototyping and Development of Microfluidic and BioMEMS Devices

A CRITICAL NATIONAL NEED IDEA

Projet ConProMi : convergence Microtechnologie / Plasturgie dans la fabrication des outillages et l intégration des capteurs

Detailed Design Review. P15611: Digital Microfluidics Packaging

Development of High-Speed High-Precision Cooling Plate

Keysight Technologies How to Choose your MAC Lever. Technical Overview

Lab-on-a-Chip Design + Foundry Service

Microstockage d énergie Les dernières avancées. S. Martin (CEA-LITEN / LCMS Grenoble)

一 Development of microchip integrated with electrochemical sensor in conjunction with indium tin oxide electrode

Anodes and Misc Equipment

OEM-EP Pressure Controllers

SUCRALOSE. White to off-white, practically odourless crystalline powder

Appendix 5 Overview of requirements in English

Amino Acid Analyzer L-8900

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Protein Interaction Analysis

Paper No APPLICATION OF EQCM TO THE STUDY OF CO2 CORROSION

TENDER DOCUMENT PURCHASING EQUIPMENT FOR PEPTIDE SYNTHESIS

INTERNATIONAL ATOMIC ENERGY AGENCY INSTRUMENTATION UNIT SMD (SURFACE MOUNTED DEVICES) REPAIR S. WIERZBINSKI FEBRUARY 1999

TC50 High Precision Power Thin Film chip resistors (RoHS compliant Halogen Free) Size 1206, 0805, 0603

WW12X, WW08X, WW06X, WW04X ±1%, ±5% Thick Film Low ohm chip resistors

E F G. Overview of the activities. SAPIE ZA Università di Roma - Laboratorio di Fotonica Molecolare

Corrosion experiments in amine solutions

The role of the magnetic hard disk drive

Data Sheet VITOSOL 100. Flat collectors for the utilisation of solar energy. Vitosol 100. Part nos. and prices: see price list

Galvanic cell and Nernst equation

Karl-Fischer Titration the method for determining water

Organic semiconductors

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

Design for Microfluidic Device Manufacture Guidelines

High Sensitivity MS Determination of Carryover in a New Autosampler Design

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

AT11805: Capacitive Touch Long Slider Design with PTC. Introduction. Features. Touch Solutions APPLICATION NOTE

THERMAL TRANSFER GARMENT LABEL SYSTEM. LCD screen on top of printer

Excerpt Direct Bonded Copper

Sony LTO Data Media Storage Tapes

Sensors for plastic manufacturing Solutions in partnership from a single source

Type RP73 Series. SMD High Power Precision Resistors. Key Features. Applications. Characteristics - Electrical - RP73 Series - Standard

RESULTS OF ICARUS 9 EXPERIMENTS RUN AT IMRA EUROPE

Dry Film Photoresist & Material Solutions for 3D/TSV

PART 1 - INTRODUCTION...

Simulation of Thermal Transport Based Flow Meter for Microfluidics Applications

WŝŽŶĞĞƌŝŶŐ > ĞdžƉĞƌŝĞŶĐĞ ƐŝŶĐĞ ϭϵϳϰ WŝĐŽƐƵŶ ^he > Ρ ZͲƐĞƌŝĞƐ > ƐLJƐƚĞŵƐ ƌŝěőŝŷő ƚśğ ŐĂƉ ďğƚǁğğŷ ƌğɛğăƌđś ĂŶĚ ƉƌŽĚƵĐƟŽŶ d, &hdhz K& d,/e &/>D /^, Z

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

A.17. OXIDIZING PROPERTIES (SOLIDS)

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Dew-Point Measurement Solutions

Injection moulding and modelling on a micro scale

Flexible Mehrlagen-Schaltungen in Dünnschichttechnik:

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Journal bearings/sliding bearings

Lisboa, July 2, Bioelectronics. Luís Alcácer. 2005, it - instituto de telecomunicações. Todos os direitos reservados.

HSeries. High Power High Quality. Ultra-High Speed, Sensing Ionizer SJ-H Series

Water Visualization and Flooding in Polymer Electrolyte Membrane Fuel Cells. Brian Holsclaw

Fabrication of Complex Circuit Using Electrochemical Micromachining on Printed Circuit Board (PCB)

ÄKTA system Training Guide

Combined atomic force microscope and acoustic wave devices: application to electrodeposition.

Dependency of heat transfer rate on the Brinkman number in microchannels

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Technology Developments Towars Silicon Photonics Integration

Power Dissipation Considerations in High Precision Vishay Sfernice Thin Film Chips Resistors and Arrays (P, PRA etc.) (High Temperature Applications)

General Purpose ph/orp Sensors

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

Split / Splitless Injection for Capillary GC

CHAPTER CONTENT PAGE. Hybrid: The perfect solution for all systems. Explanation of the - Heat Exchanger 4. Finishes 12

Application Note. Determination of Nitrite and Nitrate in Fruit Juices by UV Detection. Summary. Introduction. Experimental Sample Preparation

Pulse Withstanding Thick Film Chip Resistor-SMDP Series. official distributor of

VIESMANN. Datasheet Part numbers and prices: see pricelist VITOSOL 200-F. Flat-plate collector for the utilisation of solar energy

Electrodeionization (EDI)

Machine needle shut-off nozzle type-a

Multi-elemental determination of gasoline using Agilent 5100 ICP-OES with oxygen injection and a temperature controlled spray chamber

The Determination of Sugars in Molasses by High-Performance Anion Exchange with Pulsed Amperometric Detection

How To Make A Plasma Control System

Potentials of Aerosoljet Printing for Manufacturing 3-D MID

YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

Digital inductive conductivity transmitter

10 is a soft polymer clay that can easily be moulded by hands (S1-Left). The simplest option is to create

Supporting Information: Electrochemical imaging for microfluidics: a full-system approach

How MOCVD. Works Deposition Technology for Beginners

Planar interdigitated electrolyte-conductivity sensors on an insulating substrate covered with Ta 2 O 5

SALES SPECIFICATION. SC7640 Auto/Manual High Resolution Sputter Coater

Preparation of ZnS and SnS Nanopowders by Modified SILAR Technique

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Jeong-Yeol Yoon. Introduction to Biosensors. From Electric Circuits to Immunosensors. f) Springer

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

900 series. Flat panel Floor stands. The 900 series Flat panel Floor stands.

Submersion/Insertion Toroidal Sensor

450TOC Analyzer. Portable, Real-time, Continuous Total Organic Carbon Measurement. 450TOC Analyzer

Solar Photovoltaic (PV) Cells

Transcription:

Microfluidics and electrochemical sensors are integrated in a single chip by thin-film technologies. Integrated thinlayer hybrid SU-8/Glass chips offer a suitable analytical solution for multiple applications.» Microfluidic features Thin-film technologies enable the integration of microfluidics and (micro)electrodes in an small chip with high resolution and precision. Oulet Inlet WE WE1 WE2» External dimensions: 10 x 6 x 0.8 mm» Substrate: Glass» Microfluidic stage: SU-8 resin» Channel width: 250 µm / 1 mm (EC cell)» Channel height: 40 µm» Channel volume: 55 nl» Inlet / outlet: 0.7 mm Ø» Electrode material: Platinum or Gold» Thin-film electrode packs Microfluidic EC Sensors are supplied in 20 units packs. They should be stored at room temperature in a dry place.» Applications Integrating microfluidics with electrochemical sensors allow to improve the control of fluids on the electrode surface. Microfluidic electrochemical sensors are used as thin-layer based flow-cell in flow injection analysis (FIA) systems. Microfluidics enable the accurate control of low sample/ reagents volume (55 nl internal channel volume) through the electrodes. It offers several advantages for the modification of the electrode surface and the development of chemical sensors and biosensors. MICRUX 02

Microfluidic» Microfluidic / electrochemical structures Different single-electrodes (SE) or interdigitated array (IDA) microelectrodes are integrated on the microfluidic structure on-chip. The basic microfluidic structure (single-channel) is manufactured in SU-8 resin on a glass substrate containing the metal-based (micro)electrodes.» Microfluidic single-electrode (SE)» Microfluidic interdigitated array (IDA) SU-8 top layer (inlet/outlet) SU-8 microfluidic structure Metal electrodes on glass Electrochemical Cell» TL-SE1-Pt» TL-SE1-Au» TL-IDA-Pt» TL-IDA-Au WE1 WE2 WE WE WE1 WE2 Microfluidic channels enable a high control of the samples/fluids through the electrode surface. Thus, the electrochemical reactions, modifications and other processes related to the electrode surface are enhanced. MICRUX 03

» Microfluidic Single-Electrode Sensors Single electrodes integrated on thin-layer chips are available in platinum and gold. Reference Material WE area Thickness» TL-SE1-Pt Ti/Pt 0.3 mm 2 50/150 nm» TL-SE1-Au Ti/Au 0.3 mm 2 50/150 nm» Precision Intra- & Inter-chip Successive injections of 1 10-5 M pap in a FIA system using a thin-layer microfluidic single platinum electrode (TL-SE1-Pt). Carrier: 0.1 M PBS, ph = 7.4, flow rate = 1,0 ml/min, E d = +0.4 V. RSD = 2%, n = 13. Amperometric response for 1 10-5 M pap in a FIA system using different thin-layer microfluidic chips (TL-SE1-Pt).» Microfluidic Interdigitated Array Sensors Interdigitated microelectrodes integrated on thin-layer chips are available in platinum and gold with different sizes. Reference Material µelectrode width µelectrode gap Number of feet Thickness» TL-IDA1-Pt Ti/Pt 10 µm 10 µm 15 pairs 50/150 nm» TL-IDA1-Au Ti/Au 10 µm 10 µm 15 pairs 50/150 nm» TL-IDA5-Pt Ti/Pt 5 µm 5 µm 30 pairs 50/150 nm» TL-IDA5-Au Ti/Au 5 µm 5 µm 30 pairs 50/150 nm» Same detection potential» Different detection potential WE1= +0,4V WE1= +0,4V WE2= +0,4V WE2= -0,1V Amperograms for 1 10-5 M pap in a FIA system using a thin-layer microfluidic interdigitated array platinum electrode (TL- IDA1-Pt) applying same and different detection potentials. Carrier: 0.1 M PBS, ph = 7.4, flow rate = 1,0 ml/min. MICRUX 04

» Microfluidic sensors related accessories Microfluidic sensors are compatible with the innovative All-in-One (AIO) platform. The AIO cell (Ref. ED-AIO-CELL) provides an unique multipurpose interface with movable add-ons that can be easily interchanged for using the standard (10 x 6 mm) chips. A special add-on has been developed to enable the use of microfluidic electrochemical sensors in a flow system with a thin-layer approach. The thin-layer based flow-cell improves the control of fluids getting better precision with lower dead volume and low sample requirements.» Thin-layer Add-on (Ref. TL-PMMA-1,0 / TL-PEEK-1,0) Thin-layer add-on is available in PMMA or PEEK. Add-ons TL-PMMA-1,0 & TL-PEEK-1,0 are compatible with the microfluidic electrochemical sensors, TL-SE1 & TL-IDA1. The add-on is joined to the base-cell (AIO) by means of magnets. The inlet/outlet of the microfluidic channel is sealed with two 1,15 mm I.D. O-rings. The add-on integrates standard fluidic ports (¼ - 28 UNF) with inlet channel of 0.5 mm I.D. MICRUX 05

Severo Ochoa Building Floor -1 Room 4 & 6 Julián Clavería s/n 33006 Oviedo (Asturias) SPAIN Phone/FAX: +34 984151019 E-mail: info@micruxfluidic.com Web: Smart Microfluidic and Electrochemical olutions for Research Science