QFM4160. Duct Sensor. Siemens Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Similar documents
Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Duct Humidity Transmitter

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Heating Controller. Building Technologies HVAC Products

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

RRV934. Multi-controller. Synco living

Digital input modules

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

HCR3.2/.. Chipcard reader HOTEL SOLUTION

TX OPEN RS232/485 module

OZS Web server. For LPB/BSB plants

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

J TB/TW Temperature limiter, temperature monitor

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Incubator with mechanical convection

Digital inductive conductivity transmitter

OZW30. Central Unit SYNERGYR

Electronic Control Devices The European Product Catalogue 2007

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Capteur température et humidité pour HVAC

DS 600. A contact free flux gate based current measurement sensor 600A rms

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Pressure transmitter For general industrial applications Model A-10

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

Material test chamber with mechanical convection

Hand-held thermometer Model CTH7000

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

AXIS T81B22 DC 30W Midspan

Flush-mount room temperature sensor AQR2531ANW.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

HMI display Installation Guide

Temp-485-Pt100. A temperature sensor (Pt100 or Pt1000) communicating over the RS-485 bus with a simple communication protocol

Air damper actuators

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

USER'S GUIDE. Vaisala HUMICAP Humidity Transmitter Series HMP140A U175EN15

INPUT/OUTPUT MODULE CONVERT INPUTS AND OUTPUTS TO WIRELESS

HERZ-Thermal Actuators

Adjustment functions for both span and shift have been incorporated

Cross-beam scanning system to detect slim objects. 100 mm in

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Cable Plug acc. to DIN EN , Form A

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

H45 LED - Direct and indirect pendant

Mounting Instructions. Torque Transducer. A en

RM4TG20 three-phase network control relay RM4-T - range V

Adjustable room thermostat for heating only or cooling only systems

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Electronic Pressure Switch EDS 300

OZW V2.0. Web server. Synco TM, Synco TM living

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Inductive sensor NI10-M18-Y1X-H1141

How To Power A Schen

Technical Data. Dimensions

Vario-Series Accessories

Radiant Temperature Sensor TY7321

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

OLI. Oil level indicator

Material: Weight: Bearing Life: Shaft Speed: Starting Torque: Mass Moment of Inertia: Shaft Loads:

Small U-shaped Micro Photoelectric Sensor. Enables space saving and quick installation!

T0118 T2118 T3118. Instruction Manual

IPThermo206G. Offline/online data collector, SMS alarm sender, watchdog terminal for IPThermo Pro network

SINEAX U553 Transducer for AC Voltage

Drayton Digistat +2RF/+3RF

Electronic Control Devices The European Product Catalogue 2007

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Quick Connect. quick - simple - efficient.

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

ATL Fuel Level Sender Probes

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Modular I/O System Analog and Digital Interface Modules

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

CompactLogix Power Supplies Specifications

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Room Temperature Sensors

PCS0100en Persy Control Services B.V. Netherlands

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

How To Use A Flowmeter

Installation, operation and maintenance manual TX 35A

Vacuum drying oven for non-flammable solvents

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Terminal Boxes Series 8146

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Transcription:

1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensor for relative humidity and temperature with calibration certificates QFM4160 Operating voltage AC 24 V or DC 13.5...3 Signal output DC 0...10 V for relative humidity and temperature Very high measuring accuracy throughout the entire measuring range Capacitive humidity measurement Recalibration service Use The QFM4160 sensor is used in ventilation and air conditioning plants requiring: Very high accuracy and reliability for measuring relative humidity and temperature Regular recalibration and readjustment of the sensors Examples: Storage and production facilities in the paper, textiles, pharmaceutical, chemical, electronics industries, etc. Laboratories Hospitals Computer centers Greenhouses CE1N1883en 26.07.2004 Siemens Building Technologies HVAC Products

Ordering and delivery When ordering, please give name and type reference: Room sensor QFM4160 The circular connector with its screwed plug is delivered uninstalled. Equipment combinations The QFM4160 is for use with all types of systems and devices that can acquire and handle the sensor s DC 0...10 V output signal. Technical design Relative humidity Temperature The sensor acquires relative humidity via its capacitive sensing element whose capacitance varies as a function of the relative humidity of the ambient air. An electronic circuit converts the sensor s signal to a continuous DC 0...10 V signal, corresponding to a relative humidity of 0...100 %. The sensor acquires the temperature via its sensing element whose electrical resistance varies according to the temperature of the ambient air. This variation is converted to an active DC 0...10 V output signal, corresponding to a temperature range of 0...50 C, 35...+35 C, or 0...70 C. The measuring range can be selected. Ausführung Setting element The duct sensor consists of housing, printed circuit board, connection terminals, immersion rod with measuring probe and circular connector. The housing consists of 2 parts: Base and removable cover (screwed). A rubber seal is installed between the housing and cover in order to satisfy the requirements of IP 65 degree of protection. The measuring circuit and the setting element are accommodated on the printed circuit board inside the cover the connection terminals on the base. The sensing elements are located at the end of the measuring probe, protected by a screw-on filter cap. Cable entry is made via the circular connector, which consists of coupling piece with M16 thread and screwed plug. The coupling piece is secured to the housing and internally wired. Immersion rod and housing are made of plastic and rigidly connected. The sensor is designed for screwed or flanged mounting. It can be fitted as follows: With the mounting flange supplied with the sensor (recommended), which is to be fitted to the sensor and then secured in accordance with the required immersion length, or Without mounting flange (making use of the maximum immersion length). For that propose, the housing has 4 holes for fitting the sensor directly to the air duct Range 1 2 3 Measuring range 123 Test function active U1 U2 10 V 0 V 10 V 0 V 1883Z03 The setting element is located inside the cover. It consists of 6 pins and a shorting plug. It is used for selecting the required temperature measuring range and for activating the test function. 2/6

The different shorting plug positions have the following meaning: For the active temperature measuring range: Shorting plug in the left position (R1) = 35...+35 C, Shorting plug in the mid position (R2) = 0...50 C (factory setting) Shorting plug in the right position (R3) = 0...70 C For the active test function: Shorting plug in the horizontal position: The values available at the signal output are those given in the table Test function active Behavior in the event of fault Calibration certificates If the temperature sensor is faulty, the voltage at signal output U2 is 0 V and the humidity signal at signal output U1 increases to 10 V If the humidity sensor is faulty, the voltage at signal output U1 is 10 V after 60 seconds; the temperature signal remains active The sensor and its exchangeable AQF4150 measuring tip are numbered, registered and calibrated prior to delivery. The associated calibration certificates are supplied with the sensor. Accessories Name Measuring tip (exchangeable) Filter cap (for replacement) Type reference AQF4150 AQF3101 Engineering notes To power the sensor, a transformer for safety extra low-voltage (SELV) with separate windings for 100 % duty is required. When sizing and protecting the transformer, the local safety regulations must be observed. When sizing the transformer, the power consumption of the duct sensor must be taken into consideration. For correct wiring of the sensor, refer to the Data Sheets of the devices with which the sensor is used. The permissible line lengths must be observed. Cable routing and cable selection When laying the cables, it must be observed that the longer the cables run side by side and the smaller the distance between them, the greater the electrical interference. Shielded cables must be used in environments with EMC problems. Twisted pair cables are required for the secondary supply lines and the signal lines. Mounting notes Location Caution! Fitting instructions The sensor should be mounted in the middle of the duct wall. If used in connection with steam humidifiers, the minimum distance after the humidifier should be 3 m, the maximum distance 10 m. If the application involves dew point shifting, the sensor must be fitted in the extract air duct. Only the flange must be fitted to the duct wall. The sensor is then inserted through the flange and engaged. The seal between housing and cover must not be removed, or else degree of protection IP 65 will be no longer ensured. The measuring rod's sensing elements are sensitive to impact. Avoid any such impact on mounting. Mounting Instructions are printed on the inner side of the package. 3/6

Commissioning notes Check wiring before switching on power. The temperature measuring range must be selected on the sensor, if required. Recalibration service SBT HVAC Products provides a recalibration service for used sensors. The recalibration should be performed at 12-month intervals under "normal" conditions, i.e. within the comfort range for humidity and temperature, and at air contamination levels that are not above average. Services provided The recalibration service includes the following: Delivery and invoicing of the new AQF4150 measuring tip complete with calibration certificate Delivery of a calibration certificate for the (old) measuring tip returned to SBT HVAC Products, enabling the customer to assess the time of usage of the measuring tip Technical data Power supply Cable lengths for the measuring signal U1, U2 Functional data Humidity sensor" Functional data "Temperature sensor" Degree of protection Electrical connections Operating voltage Frequency Power consumption Max. perm. cable lengths Copper cable 0.6 mm dia. Copper cable 1 mm 2 Copper cable 1.5 mm 2 AC 24 V ±20 % or DC 13.5...3 50/60 Hz 1 VA 50 m 150 m 300 m Measuring range 0...100 % r. h. Measuring accuracy at 23 C 0...100 % r. h. ±2 % Temperature dependency Time constant 0.05 % r. h./ C approx. 20 s in moving air Output signal, linear (terminal U1) DC 0...10 V 0...100 % r. h., ±1 ma max. Measuring range Sensing element Measuring accuracy in the range of 15...35 C 35...+70 C Time constant Output signal, linear (terminal U2) 0...50 C (R2 = factory setting), 35...+35 C (R1), 0...70 C (R3) Pt 1000 class B ±0.6 K ±0.8 K approx. 20 s in moving air Housing IP 65 to IEC 529 Safety class III to EN 60 730 Connector with screwed plug Screw terminals for Cable entry DC 0...10 V 0...50 C / 35...+35 C / 0...70 C max. ±1 ma Lumberg RSC 4/9 0.75 mm 2 max. 4 8 mm dia. 4/6

Environmental conditions Operation to Climatic conditions Temperature (housing with electronics) Humidity Mechanical conditions Transport to Climatic condition Temperature Humidity Mechanical conditions IEC 721-3-3 class 4K2 40...+70 C 0...100 % r. h. (with condensation) class 3M2 IEC 721-3-2 class 2K3 25...+70 C <95 % r. h. class 2M2 Materials and colors Base polycarbonate, RAL 7001 (silver-grey) Standards Cover Immersion rod Filter cap Mounting flange Circular connector Connector with screwed plug Contact carrier and body Knurled nut and contact Coupling piece Contact carrier Casing and contact Sensor (complete assembly) Packaging polycarbonate, RAL 7035 (light-grey) polycarbonate, RAL 7001 (silver-grey) polycarbonate, RAL 7001 (silver-grey) PA 66 (black) Lumberg RSC 4/9 PA, black CuZn, nickel-plated Lumberg RKFM 4/0,5 M TPU CuZn, nickel-plated silicon-free corrugated cardboard Product safety Automatic electrical controls for household and similar use EN 60 730-1 Electromagnetic compatibility Emissions Immunity conformity to conformity to Australian EMC framework Radio Interference Emission Standard EN 61 000-6-1 EN 61 000-6-3 Weight Incl. packaging 0.244 kg EMC directive 89/336/EEC Radio Communication Act 1992 AS/NZS 3548 Connection terminals G (R1 = 35...+35 C / R2 = 0...50 C / (r.h.) R3 = 0...70 C) G0 U1 U2 1883G01 G0 (3) U1 (2) 3 2 4 1 G (4) U2 (1) 1883G02 Front view: Connector fitted, body removed G, G0 Operating voltage AC 24 V (SELV) or DC 13,5...3 U1 Signal output DC 0...10 V for relative humidity 0...100 % U2 Signal output DC 0...10 V for temperature 0...50 C (R2 = factory setting) or 35...+35 C (R1) or 0...70 C (R3) 5/6

Dimensions 80 60 57 14,5 274 235 39 ø 20 ø 15 (41) 1883M01 28 3 80 50 min. 90 AQF4150 (62,8) 21(16) 60 Fixing holes with (without) mounting flange Dimensions in mm 6/6 2004 Siemens Building Technologies AG Subject to alteration