TECHNICAL BULLETIN. SKIPPED-FLOOR SYSTEM (Not Recommended) ALL-FLOORS-TIED-OFF SYSTEM (Recommended) A single point of restraint for multiple levels

Similar documents
Wood Truss Restraint and Bracing Guide

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

Simpson s Tyrell Gilb Research Laboratory: Where Discovery Meets Development

Perforated Shearwall Design Method 1

4B The stiffness of the floor and roof diaphragms. 3. The relative flexural and shear stiffness of the shear walls and of connections.

Steel joists and joist girders are

Chapter 3 DESIGN AND CONSTRUCTION FEATURES IMPORTANT TO SEISMIC PERFORMANCE

Bolting: Attachment Of The Mudsill To The Foundation

SINGLE-FAMILY EARTHQUAKE (SEISMIC) RETROFITS

6 RETROFITTING POST & PIER HOUSES

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

Bracing Webs in Trusses that have Dissimilar Configurations

What is Seismic Retrofitting?

The Base Shear Formula

Timber Frame Construction

Handling, Erection and Bracing of Wood Trusses

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Code Compliant Repair and Protection Guide

METHOD OF STATEMENT FOR STATIC LOADING TEST

Page & Turnbull imagining change in historic environments through design, research, and technology

Formwork for Concrete

Chapter 6 ROOF-CEILING SYSTEMS

Seismic Retrofit Guide

National Council of Examiners for Engineering and Surveying. Principles and Practice of Engineering Structural Examination

SECTION 7 Engineered Buildings Field Investigation

System. Stability. Security. Integrity. 150 Helical Anchor

Hybrid simulation evaluation of the suspended zipper braced frame

bi directional loading). Prototype ten story

Introduction to Solid Modeling Using SolidWorks 2012 SolidWorks Simulation Tutorial Page 1

Chapter 3 - Structural Design

Wisconsin Building Products Evaluation

Five reasons buildings fail in an earthquake and how to avoid them

Prepared For San Francisco Community College District 33 Gough Street San Francisco, California Prepared By

Structural Design for Residential Construction

Common Errors in Truss Design

Discipline: Structural Issued

Featuring TJ Rim Board and TimberStrand LSL

OPTIMAL DIAGRID ANGLE TO MINIMIZE DRIFT IN HIGH-RISE STEEL BUILDINGS SUBJECTED TO WIND LOADS

The Stabilizer TM. Benefits. Supplemental support system for sagging beams and floor joists within a crawl space

Chapter 10 - Scaffolding Systems

Expected Performance Rating System

Breakaway Walls

TYPICAL PATIO COVERS 111

DESIGN OF BLAST RESISTANT BUILDINGS IN AN LNG PROCESSING PLANT

STANDARD OPEN PATIO COVER

[TECHNICAL REPORT I:]

1997 Uniform Administrative Code Amendment for Earthen Material and Straw Bale Structures Tucson/Pima County, Arizona

Guide to Safe Building Practices

Structural Axial, Shear and Bending Moments

MODULE E: BEAM-COLUMNS

DISASTER RESISTANCE EARTHQUAKES AND STRUCTURES

Seismic Assessment of Engineering Systems in Hospitals A Challenge for Operational Continuity

Post and Beam Construction

research report Residential Hip Roof Framing Using Cold-Formed Steel Members RESEARCH REPORT RP06-2 American Iron and Steel Institute

Stability. Security. Integrity.

Structural Seismic Retrofits For Hawaii Single Family Residences With Post and Pier Foundations

Elevating Your House. Introduction CHAPTER 5

Connection Solutions

TRAINING OUTLINE FOR PART TIME BUILDERS

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

Type of Force 1 Axial (tension / compression) Shear. 3 Bending 4 Torsion 5 Images 6 Symbol (+ -)

ETABS. Integrated Building Design Software. Concrete Shear Wall Design Manual. Computers and Structures, Inc. Berkeley, California, USA

Watts Spacemaker. Sa f e t y Wa t e r He a t e r. Enclosures Stands Restraints

Chapter 3 Pre-Installation, Foundations and Piers

INTERIM REPORT ON TESTING OF TENSION- ONLY STEEL ANCHOR RODS EMBEDDED IN REINFORCED CONCRETE SLABS

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Timber frame structures platform frame construction (part 1)

ICC-ES Evaluation Report

T-14 Tilt-Up Wall Braces

RZ Guardrail System Installation Manual

Structural Foundation System

Seismic Retrofit Guide

POST AND FRAME STRUCTURES (Pole Barns)

ARCH 331 Structural Glossary S2014abn. Structural Glossary

Chapter 3 FOUNDATIONS AND FOUNDATION WALLS

Building Construction. Lightweight construction. Conventional Construction

A Solid Foundation Solution for Homeowners. from. Our products are made with 90% Recycled Material Down. Right. Solid. GREEN.

LINKED COLUMN FRAME STEEL SYSTEM PERFORMANCE VALIDATION USING HYBRID SIMULATION

INSTALLATION. General. Important Note. Design. Transport

Analysis and Repair of an Earthquake-Damaged High-rise Building in Santiago, Chile

Collapse of Underground Storm Water Detention System

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

STRUCTURAL ASSESSMENT REPORT BOLINAS MARINE STATION - BOLINAS, CALIFORNIA

THE DESIGN OF BUILDING SERVICES FOR EARTHQUAKE RESISTANCE

Technical Notes 3B - Brick Masonry Section Properties May 1993

Statics of Structural Supports

Miss S. S. Nibhorkar 1 1 M. E (Structure) Scholar,

Green Thread Product Data

March 14, Installation of Bay, Bow and Garden Windows

Shaft- Mounted Speed Reducers

Collective Chord Behavior in Large Flexible Diaphragms

ARCHITECTURE. Asst. Prof. Meltem VATAN KAPTAN

CPA Steel Stud Framing Page 1 of 11

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Firewalls. By Gary Sturgeon, B.Eng., MSc., P.Eng. Technical Services Engineer, CCMPA. w w w. c c m p a. c a 5A-0

Seismic Analysis and Design of Steel Liquid Storage Tanks

Hunter College school of Social Work Thesis Proposal

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Transcription:

OVERVIEW Page 1 of 8 In multi-story, light-frame structures, site-built shear walls may be required to resist extremely high overturning forces. These shear walls often require an alternative system to conventional holdowns. Continuous tie-down systems have emerged as a solution to resist these loads. At times, plans may include continuous tie-down systems that skip floors as a means of reducing project costs. Skipping a floor means that one point of restraint is expected to support more than one building level. After extensive testing and analysis Simpson Strong Tie determined that skipping floors results in significant loss of shear wall performance when compared with shear wall performance in an all-stories-tied-off system. Moreover, skipping floors results in other issues to consider, such as increased component sizes, increased drift, reduced redundancy, shrinkage and construction stability. Component Sizes. In a skipped-floor system, the overturning forces transfer further up the building until a restraint is reached. As a result, elements at and below the restrained point have to resist higher uplift forces necessary to constrain the unrestrained stories below. This results in increased lumber, threaded rod, and bearing plate sizes. In a tied-off system, the incremental forces at each level are transferred directly into the tie-down system at that level. Drift. Shear walls must be designed for both strength and lateral stiffness. A skipped-floor system that is designed only for strength probably will not be sufficient to satisfy drift requirements. Test results indicate that skipping floors has the potential to substantially increase inter-story drift. Drift analysis is important for all shear walls, but it is particularly critical in skipped-floor systems. Redundancy. Even when they are appropriately designed, structural elements can perform unexpectedly during major seismic and high-wind events. In a skipped-floor system, multiple floors rely on a single component for their performance. If that element fails, the entire uplift resistance for all non-restrained floors below may be compromised. With an all-floors-tied-off system, the lower floors do not rely on the stability of the upper floors for their performance. Construction Stability. When a system is designed to be tied off at each story, it allows the contractor to laterally restrain the building as construction progresses. In a skipped-floor system, the Designer or builder should consider a temporary bracing method during construction until the tie-down system is fully engaged, to prevent collapse or damage during a seismic or wind event. SKIPPED-FLOOR SYSTEM (Not Recommended) ALL-FLOORS-TIED-OFF SYSTEM (Recommended) Point of Restraint Points of Restraint A single point of restraint for multiple levels Overturning restraint provided at each level Patent Pending

SKIPPED-FLOOR SYSTEMS Page 2 of 8 The illustration below shows an example of a skipped-floor system in a three-story structure second- and third-floor restraints are not provided (skipped). A single bearing plate at the top level is the sole point of restraint. Lack of system redundancy with respect to top-down load path: Single restraint at top receives total uplift force from bottom. If element fails, whole system fails overall cost: Post size at upper floors must be larger than post size for all-floorstied-off system drift: Effect of rod elongation accumulates at lower floors overall cost: Bearing plate must be sized for total uplift force from all floors Single device must accommodate shrinkage from all floors: Shrinkage device at top receives cumulative shrinkage Upper floor elements must resist lower floor loads: No bearing plates or shrinkage devices at floors drift: compression forces increase crushing overall cost: Rod size of bottom floor must be same for all floors SUMMARY: cost for posts, rods and bearing plates drift Lack of system redundancy Shrinkage not accommodated at each floor Inefficient load path Lack of construction stability

ALL-FLOORS-TIED-OFF SYSTEMS Page 3 of 8 The illustration below shows an example of an all-floors-tied-off system. Each floor is restrained with a bearing plate and nut. Lower overall cost: Post and rods can decrease in size on upper floors Accommodates shrinkage at each floor independently: Individual rods are connected at each floor by a coupler take-up device Greater system redundancy and is consistent with typical design load path: Restraint provided at all floors. Lower levels are not dependent on restraint of floors above Reduced drift: Tying off at each floor does not allow the effect of rod elongation to accumulate at lower floors Reduced drift: Lower compression forces reduce crushing Forces in the elements get smaller as they move up the structure: Bearing plate restraints provided at all floors. As a result, tension loads are smaller on upper floors SUMMARY: Cost savings on posts, rods and bearing plates Reduced drift System redundancy Shrinkage accommodated at each floor Efficient load path Construction stability

UPLIFT LOAD PATH OF A SKIPPED-FLOOR SYSTEM Page 4 of 8 Detail A Steel bearing plate is designed for bending and perpendicular-to-grain bearing load of 27 kips. ROOF Distributed compression load from sheathing to posts Detail A F3 = 4 kips T3 = 27 kips C3 = 13 + 10 + 4 = 27 kips Post compression due to uplift forces on uplift side of wall 27 kips 13.5 kips 13.5 kips Posts are designed for buckling load and perpendicular-to-grain bearing loads on top plates of 13.5 kips each. 3rd FLOOR F2 = 10 kips T2 = 27 kips C2 = 13 + 10 = 23 kips 23 kips 27 kips 2nd FLOOR 13 kips LOAD PATH: Load path is from bottom to top and then back to bottom not efficient. Overturning loads are transferred to posts through boundary nailing and travel upward through compression until finding a point of restraint at the top of the building. The whole system is restrained at the upper most top plate by a large steel bearing plate. Bearing plate transfers the load to the nut and then the rod. The free body-diagram shows that top floor tension force is a result of all of the lower posts transferring the cumulative uplift load upward to the top floor before coming back down. In order for this to happen, the posts in the lower floors must carry that force up in compression. Therefore, posts in the top floor must resist the uplift force from bottom floor. 1st FLOOR TTOT = 27 kips F1 = 13 kips T1 = 27 kips C1 = 13 kips Note: F1, F2 and F3 are inter-story uplift forces. T1, T2 and T3 are rod tension loads. C1, C2 and C3 are the post compression loads due to uplift forces. Example does not include gravity loads. Axial Load Diagram of Posts on Uplift Side of Wall

UPLIFT LOAD PATH OF AN ALL-FLOORS-TIED-OFF SYSTEM Page 5 of 8 2 kips Detail B Steel bearing plate is designed for bending and perpendicular-to-grain bearing load of 4 kips on top plates. 2 kips Posts are designed for buckling load and perpendicular-to-grain bearing loads on top plates of 2 kips each. Detail C 14 kips ROOF Distributed compression load from sheathing to posts Coupler 3rd FLOOR 2nd FLOOR Detail B F3 = 4 kips T3 = 4 kips C3 = 4 kips F2 = 10 kips T2 = 10 + 4 = 14 kips C2 = 10 kips Post compression due to uplift forces on uplift side of wall 4 kips 10 kips 13 kips LOAD PATH: 4 kips Overturning loads are transferred to posts through boundary nailing and travel upward through the floor system until finding a point of restraint at each story. Floor system or roof top plates resist the post uplift from each floor below. The posts are engaged in compression because of uplift from the inter-story load. Floor system or roof top plates are held down by the bearing plate on the sole plate or roof top plates. The bearing plates resist inter-story uplift load at each floor. Bearing plates transfer the incremental load to the nut and then the rod. The free-body diagram shows that posts on top floor resist the uplift force from the top floor only. 13 Kips 27 kips Incremental Bearing at each floor allows tie off to occur. Upper floors are no longer required to resist uplift forces from floors below. 1st FLOOR TTOT = 27 kips F1 = 13 kips T1 = 13 + 10 + 4 = 27 kips C1 = 13 kips Note: F1, F2 and F3 are inter-story uplift forces. T1, T2 and T3 are rod tension loads. C1, C2 and C3 are the post compression loads due to uplift forces. Example does not include gravity loads. Axial Load Diagram of Posts on Uplift Side of Wall

TEST RESULTS MEASURING INTER-STORY DRIFT Page 6 of 8 Simpson Strong-Tie conducted a series of tests to compare the differences between skipped-floor and tied-off systems. Four types of three-story shearwall systems were tested on a shake table at the state-of-the-art Simpson Strong-Tie Tyrell Gilb research laboratory in Stockton, California. The four systems included: All floors tied off All floors skipped Second floor skipped Third floor skipped The testing simulated a 6.7 magnitude earthquake ground motion to compare the drift for each story (inter-story drift) of each system. Building codes require the inter-story drift to be less than 2.5% of the story height. In this case, the tested shearwall systems measured 96" in height for each story, resulting in a 2.4" allowable inter-story drift. The test results concluded that skipping floors has the potential to significantly increase inter-story drift and reduce shearwall performance. The three skipped-floor systems did not perform as well as the all-floors-tied-off system and in this case, did not meet code drift limitations on the lowest floor of the set of skipped floors. The significant increase in the drift can be mainly attributed to: Full-scale test set up for a three-story skipped-floor system. First Floor SHAKE TABLE All Floors Second FLOOR SKIPPED at Top and Lowest Story of Set of 2 Stories Tied Together First Floor SHAKE TABLE LARGE UPLIFT & ACCUMULATED ELONGATION Effect of rod elongation accumulated at the lowest floor of a set of skipped-floors Accumulated elastic compression of the floor systems on the uplifting side of the wall Accumulated compression (perpendicular-to-grain deformation) of top plates and sill plates on the uplifting side of the wall ALL FLOORS SKIPPED at Top Only Lowest Story of Set of 3 Stories Tied Together First Floor SHAKE TABLE LARGE UPLIFT & ACCUMULATED ELONGATION THIRD FLOOR SKIPPED Lowest Story of Set of 2 Stories Tied Together First Floor SHAKE TABLE at Top and LARGE UPLIFT & ACCUMULATED ELONGATION NOTE: Deflected shapes are exaggerated for illustration clarity.

First STORY INTER-STORY DRIFT COMPARISON For the all-floors-skipped and the second-floor-skipped configurations, the first story is the bottom story of the group of stories tied together (see system illustrations on page 6). This story experiences the greatest increase in inter-story drift. The graph below compares this drift with that from the tied-off system. 14000 12000 10000 CODE = ALLOW = 2.4'' for 8'-0'' Plate Height 100% Increase in First Story Interstory Drift Skipped* Page 7 of 8 8000 All Floors Applied First Story Shear, lbs. 6000 4000 2000 0-2000 -4000 All Floors Skipped* -6000-8000 -10000-2.5-2 -1.5-1 -0.5 0 0.5 1 1.5 2 2.5 3 3.5 *Did not meet code drift limit. First Story Inter-Story Drift, inches Second STORY INTER-STORY DRIFT COMPARISON For the third-floor-skipped configuration, the second story is the bottom story of the group of stories tied together (see system illustrations at right). This story experiences the greatest increase in inter-story drift. The graph below compares this drift with the second story drift of the tied-off system. Applied Second Story Shear, lbs. 10000 8000 6000 4000 2000 0-2000 -4000 CODE = ALLOW = 2.4" for 8'-0'' Plate Height All Floors Skipped* -6000-8000 -10000-2.5-2 -1.5-1 -0.5 0 0.5 1 1.5 2 2.5 3 3.5 Second Story Inter-Story Drift, inches *Did not meet code drift limit.

Continuous Tiedown STRONG-DRIVE Systems FOR SHEAR WALLS: SCREW APPLICATIONS Four Methods for Specifying ATS We recognize that specifying Simpson Strong-Tie ATS is unlike choosing any other product we offer. You must first address several design questions and considerations to ensure that the system will be configured to meet the design intent. These considerations might include whether to use ATS, or conventional holdowns and strapping; determining the project s incremental and cumulative loads; or, specification of elongation limits, for example. For more on these issues and many others, please visit www.strongtie.com/ats. We currently offer the following four methods of specifying ATS: Page 8 of 8 ATS Selector Software 1. Use our ATS Selector software for customized runs Many Designers find it convenient to use our free ATS Selector software to design custom runs to meet their exact demand loads. With this method of specification the ATS Selector software creates drawings of the custom runs for placement in the construction documents. Since the runs are customized, they are less expensive than comparable catalog runs. The current ATS Selector software does not yet optimize the runs with the latest improvements in the ATS product line, but Simpson Strong-Tie can review these jobs to ensure the most cost-effective solutions are specified on the construction documents; this service is provided at no additional cost. For this review, the Designer need only e-mail the ATS design file to engineeringservices@strongtie.com. Our team will optimize the runs to include the most cost-effective ATS products, and quickly return installation drawings and calculations to the Designer. 2. Send us your loads and we ll optimize the runs Designers who do not use the ATS Selector software can also receive customized run drawings that incorporate the cost-savings from the expanded ATS product line. After sending us your project loads and criteria in a spreadsheet, we will customize the runs and quickly return installation drawings and calculations. To utilize this free service, please download a copy of the spreadsheet at www.strongtie.com/ats. E-mail the completed spreadsheet to engineeringservices@strongtie.com. Our team will optimize the runs to include the most cost-effective ATS products, and quickly return installation drawings and calculations to the Designer. Generic Installation Details ATS Design Load Spreadsheet 3. Provide loads and generic specifications on drawings Simpson Strong-Tie can also provide customized runs for Designers who prefer to include only design loads and generic specifications on their construction drawings. This works well, provided that all the design information is clearly specified, including: cumulative tension and compression loads, anchorage requirements, elongation limits, run locations, etc. All this information is critical to specifying a system that meets the Designer's intent. To assist Designers who prefer this method of specification we have created recommended installation drawings and notes. These details contain the critical information needed to design the runs properly. Download them at www.strongtie.com/ats. Our team will optimize the runs to include the most cost-effective ATS products and provide installation drawings and calculations for review and approval. 4. Specify catalog runs from the ATS catalog For years, Simpson Strong-Tie has listed model numbers for catalog ATS runs in the Anchor Tiedown System for Multi-Story Overturning Restraint catalog. This enables Designers to easily specify ATS without having to provide ATS run details and installation drawings on their construction documents. While this specification method does not offer the same customized, cost-saving features as other methods, Simpson Strong-Tie does provide support for jobs specified with catalog runs. During the design review phase of the project, our team will optimize the runs to include the most cost-effective ATS products and provide installation drawings and calculations for review and approval as a cost-effective alternative to the catalog runs. ATS-N Nut ATS-BP Bearing Plate ATS-SR Strong-Rod CNW/ATS-C Coupler Nut ATS-IN Nut ATS-BP Bearing Plate ATS-SR Strong-Rod ATS-CTUD Coupling Take-Up Device ATS-IN Nut ATS-BP Bearing Plate ATS-SR Strong-Rod ATS-CTUD Coupling Take-Up Device ATS-AB Anchor Bolt Catalog ATS Run DBL TOP PLATES 6" 6" 6" This technical bulletin is effective until June 30, 2013, and reflects information available as of February 1, 2011. This information is updated periodically and should not be relied upon after June 30, 2013; contact Simpson Strong-Tie for current information and limited warranty or see www.strongtie.com. 2011 Simpson Strong-Tie Company Inc. P.O. Box 10789, Pleasanton, CA 94588 T-SKIPfLOORS11 2/11 exp. 12/31/15 800-999-5099 www.strongtie.com