POINT OF CARE TESTING - Waived Testing Staff Competency Checklist

Similar documents
INTRODUCTION TO CLINICAL PRACTICE AND CLINICAL SKILLS 2nd Year MEDICAL YEAR 2009/2010

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM

STANDARD OPERATING PROCEDURE FOR NOVA STAT STRIP CONNECTIVITY BLOOD GLUCOSE METERS FOR USE IN LEEDS NHS TRUST

URINE DIPSTICK Multistix 10SG

PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

Hemoglobin Testing using the Data Management HemoCue Analyzer

Chapter 14 Urinalysis, Body Fluids and Other Specimens. Objectives:

Title: Fingerstick Glucose by Accu-Chek Inform

OneStep Fecal Occult Blood RapiDip InstaTest. Cat #

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

Explain the role of blood and bloodstain patterns in forensics science. Analyze and identify bloodstain patterns by performing bloodstain analysis

Contents. POCT Program Massachusetts General Hospital - Pathology Service 55 Fruit Street, Boston, MA 02114

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

The Determination of an Equilibrium Constant

Aseptic Technique. A GMP/GTP Training Module

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

APPENDIX N BULK MILK TANKER SCREENING TEST FORM

(800) Cryo-Cell.com

A Self-Study Packet for The Johns Hopkins Hospital Point-of-Care Testing Program copyright 2011 Johns Hopkins Hospital All rights reserved

Cidex OPA Solution Training Checklist and Competency for Semi-Critical Medical Devices

Blood Collection and Processing SOP

General. What is a laboratory test? What is a waived test?

POC.PC.17 Point of Care Testing AMNISURE PROCEDURE FOR RUPTURED FETAL MEMBRANES TABLE OF CONTENTS. 1.0 Principle of Procedure.. 2

HUMULIN 70/30 KwikPen

Objectives At the completion of this module, unlicensed assistive personnel (UAP) should be able to:

Caring for Your PleurX Pleural Catheter

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Anti-Zona Pellucida Antibody Latex Agglutination Test

Vaginal ph Test (ph Hydrion TM Paper )

Chapter. Guaiac Screening CHAPTER 4: GUAIAC TESTING SCREENING FOR OCCULT BLOOD. Page 1 of 5 Guaiac doc 6/24/2005

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML SINGLE-USE PEN

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

BioResearch. RAFT 3D Cell Culture Kit Protocol

Contents. Approved by: Kent Lewandrowski, M.D. 6/1/2005 Written/Updated by: Gino Pagnani Date: 4/3/09

Contents. POCT Program Massachusetts General Hospital - Pathology Service 55 Fruit Street, Boston, MA 02114

Aptima Specimen Transfer Kit

Division of Laboratory Medicine Department of Pathology and Laboratory Medicine Hospital of the University of Pennsylvania

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

The Enbrel SureClick autoinjector is a single-use prefilled autoinjector. It contains one 50-mg dose of Enbrel.

Creatine Kinase (CK) Enzymatic Assay Kit Manual Catalog #:

Transferring a Broth Culture to Fresh Broth

Ward 29 guide to the safe preparation and administration of intravenous (IV) antibiotics at home

ClikSTAR - Important facts about your new insulin delivery device.

Gravity Bag Cord Blood Collection Method Training Manual

Human Free Testosterone(F-TESTO) ELISA Kit

HUMULIN (HU-mu-lin) N

Instructions for Use

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

PEAC CENTRAL LABORATORY SAMPLING MANUAL

ABORhCard. ABORhCard Package Insert ABO and Rh Blood Grouping Device

Use of Micropipettes

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML, 20 MG/0.4 ML AND 10 MG/0.2 ML SINGLE-USE PREFILLED SYRINGE

ArtisanLink Staining System is an automated special stains slide

Cooling Rewarming QUICK REFERENCE GUIDE. First change Target Temp. Always operate in Automatic Mode. Then change Warming Rate

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

HEMOCUE Procedure 1.0. S. Terence Dunn, PhD. 23-Apr : Apr-2016

MANUAL WBC LAB OBJECTIVE

Standard Operating Procedure (SOP) Work Package 8. Sample Collection and Storage

I-140 Venipuncture for Blood Specimen Collection

CHS Medical Group Hazardous Waste Management In Service

Bacterial Transformation with Green Fluorescent Protein. Table of Contents Fall 2012

Crime Scene Unit Presumptive Testing Procedures. Evidence Collection Division

Sterile Dressing Change with Tegaderm CHG for Central Venous Catheter (CVC)

Cold Agglutination Titer detecting Cold Reacting Antibodies

Title: Microbiology Urine Screening Effective date: 05/08/2013. Summary of Significant Changes at this Revision

Appendix H IBC Managing Biohazardous Waste SOP

AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance

SAMPLE PROCEDURE , 09/11

PATIENT GUIDE. Care and Maintenance Drainage Frequency: Max. Drainage Volume: Dressing Option: Clinician s Signature: Every drainage Weekly

Appendix H Managing Biohazardous Waste SOP

Partner: Jack 17 November Determination of the Molar Mass of Volatile Liquids

The Determination of an Equilibrium Constant

VENOUS BLOOD COLLECTION

Clinitek Advantus TM Analyzer. Operator s Guide ( Rev. A),

SC, FC and ST * Hot Melt Fiber Optic Connectors

URINARY CATHETER INSERTION - STRAIGHT OR INDWELLING CATHETER

Rat Fibronectin ELISA Kit

Appendix C. Vernier Tutorial

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use.

February Xerox 8265/8290 Color Wide Format Printer User Maintenance and Cleaning Guide

Bydureon 2 mg powder and solvent for prolonged-release suspension for injection in pre-filled pen How to use Bydureon pre-filled pen

BARD MEDICAL DIVISION UROLOGICAL DRAINAGE. Foley Catheter Care & Maintenance. Patient Education Guide

USAccess System- Registrar. Help Guide. Prepared for

18 Conductometric Titration

Acids and Bases. AND a widemouth container of the following solids:

Malondialdehyde (MDA) ELISA

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Kool Demo for Acid-Base Reactions

NIH Clinical Center Patient Education Materials Giving a subcutaneous injection

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

Mouse Insulin ELISA. For the quantitative determination of insulin in mouse serum and plasma

CoaguChek System. XS Plus. User Manual

CDC-Lipid Standardization Program. Laboratory Data Collection System (LDCS) Instruction Manual

Assigning Access and Roles to FAMTest

FLASH GLUCOSE MONITORING SYSTEM. User s Manual

Determining the Free Chlorine Content of Swimming Pool Water. HOCl H + + OCl. Evaluation copy

Inform II Glucose Meter

Transcription:

POINT OF CARE TESTING - Waived Testing Staff Competency Checklist Name: Unit : Procedures are On-Line at: http://manuals.ucsfmedicalcenter.org Point of Care Testing Manuals Intitials below indicate training was successfully completed. PROCEDURE ColoScreen each time a new box of slides or a new bottle of developer is opened, Quality Control (QC) must be performed using the ColoScreen monitor on the reverse side of the slide. 1. Places a drop of ColoScreen developer between the positive and negative monitor boxes on the reverse side of the slide. 2. Reads results after 30 seconds and within 2 minutes. The Positive ColoScreen Monitor should turn blue, Negative ColoScreen Monitor should have no trace of blue. 3. Records the results of the monitors on the ColoScreen QC log, including lot # and expiration date of the newly opened product. 4. Labels box of slides and/or developer with the date of QC and initials. 5. If QC fails remove product from use and returns to Material Services. 6. Patient test must be completed, and interpreted and results noted before proceeding with the QC (ColoCheck monitors on back of card). After verifying the QC monitor results, record the patient test results and the QC Monitor results on the ColoScreen Patient Results Log, the patient's medical record or UCARE. Gastroccult each time a new box of slides or a new developer is opened, QC must be done using the performance monitor area on the Gastroccult slide. 1. Places a drop of Gastroccult developer between the positive and negative monitor boxes on the slide. 2. Reads results after 10 seconds and within 60 seconds. 3. Records the results of the monitors on the Gastroccult QC log, including the lot# and expiration date of the newly opened product. 4. Labels box of slides and/or developer with the date of QC and initials. 5. If QC fails removes product from use and returns to Material Services. 6. ph is neither used nor recorded. 7. When recording a patient s test result, also document that internal quality control (Performance Monitor Area) was used and passed quality control (QC). Record QC results on patient s medical record or UCARE. POCT Waived Competency _DEC 2010 (2)_AUG_2011 (2).doc 1 of 7

ph Determination each time a new dispenser is opened, verify QC has been performed by checking color chart for initials and the date QC was performed in the lab. To test for ph: 1. Remove one to two inches of ph paper from the holder for each test. 2. Apply the tip of the paper to pooled fluid being tested. Avoid contact with any other fluids not being tested. 3. Observe for immediate color change 4. Record ph value, corresponding to the color change, as compared to the color chart. Multistix Urinalysis each time a new bottle of Multistix reagent strips is opened a QC must be done using Chex-Stix positive and negative control strips. Subsequently, a QC must be done monthly on open bottles in use more than 30 days. 1. Fills each test tube, one labeled positive and one labeled negative, with 12ml of distilled water. 2. Places a positive check strip in the tube labeled positive, a negative check strip in the tube labeled negative. 3. Inverts the tube back and forth for 2 minutes. 4. Allows the tubes with the Chek-Stix in them to stand for 30 minutes. 5. Inverts tubes and discards the Chex-Stix. 6. Dips a Multistix reagent strip into the Negative Control Solution. Compares reagent areas to corresponding color chart on bottle, following directions for proper read time. 7. Repeats step 6 with positive control solution. 8. Records the results of the QC on the Multistix QC log, including the lot # and expiration dates of the newly open product and Chex-Stix. 9. Labels the bottle of reagent strips with the date of the QC and initials. 10. If QC fails, removes the product from use and returns to Material Services. POCT Waived Competency _DEC 2010 (2)_AUG_2011 (2).doc 2 of 7

Accu-Chek Inform Blood Glucose Meter QC consists of Coding the Inform meter and running a High and Low control each day of use, and whenever a new vial of test strips is opened. Controls and test strip vials must be dated and initialed when first opened. (Observer's Initial) (Trainee's Initial) CODING THE METER 1. Compare the three-digit number on the Code Key with the code number on the test strip vial. 2. With meter turned Off, snap the new Code Key (slots facing towards the meter) into the Code Key slot with the printed side facing up. 3. Leave the new Code Key in the meter. HIGH/LOW CONTROL SOLUTION TESTING 1. Check the expiration date on controls and test strips vials. 2. Turn on the meter. 3. Scan the operator barcode. Operator ID can also be entered manually. 4. Select Control Test on the menu screen. 5. Scan the lot number on the control vial. 6. Scan the lot number on the test strip vial. 7. Gently insert test strip with the yellow target area facing up. 8. Touch and hold drop of glucose control solution to the curved edge of the yellow target area. 9. Wait for meter to display results. 10. If Pass displays, press the forward ( ) button and repeat steps 5-9 using the next level of control solution. 11. If Fail displays, repeat the test using the same control solution. 12. Enter up to 3 preprogrammed comments under the Comment menu screen. 13. Write the date and initials on the controls and test strip vials (not on the lid). 14. Place the meter in the docking station to download the information to the Clinical Laboratory. POCT Waived Competency _DEC 2010 (2)_AUG_2011 (2).doc 3 of 7

QuickVue+ Urine Pregnancy - QC consists of conducting a check with the control set each time a box of 30 QuickVue+ Urine Pregnancy tests are opened. The control set includes one bottle (4.5ml) of hcg Negative Control and one bottle (4.5ml) of hcg Positive Control. 1. Store hcg Urine Control Set at room temperature. 2. Check expiration dates on device pouches and hcg control reagents. 3. If new bottles of controls are opened, write opened date, and your initials on the bottle of control reagent. Do not use reagents beyond printed expiration date. 4. Remove 2 devices from their protective pouches. 5. Thoroughly mix contents of each bottle of control reagent by gently swirling. 6. Hold the bottle in a straight up and down position, dispense 4 drops of hcg Urine Control set Positive Control into the sample well of one device. 7. Wait 3 minutes for the colored bands to appear. 8. A Positive reading should appear on the Positive Control device. In addition to the blue band in the control window, a distinct pink band appears in the test region, creating a + sign with the preprinted horizontal blue line and the appearance of the vertical pink line. 9. Repeat the above procedure using the Negative Control into the sample well of the second device. 10. A Negative result should appear on the negative control device. Only the blue color band appears in the control window. The test region will only display the pre-printed horizontal blue line. A negative result cannot be read prior to 3 minutes. 11. Record the QC results on the QC log, along with the lot numbers and expiration dates of the newly opened product and control solutions. For the QC log, document the Lot Number printed on the exterior of the box of test devices. Test devices and controls expire on the printed expiration date on the pouches and vials. 12. Write date of QC and your initials on the box with a permanent marker to indicate that the box has passed QC. If the QC fails, remove the product from use and return to Material Services and note on log. 13. For each patient test, the appearance of the blue control band in the control window of the test device must be documented along with patient test results. POCT Waived Competency _DEC 2010 (2)_AUG_2011 (2).doc 4 of 7

Name: Unit : QuickVue Influenza Test QC consists of performing 3 external procedural controls each time a new box of 25 QuickVue Influenza test strips is opened. The external procedural control consists of Positive A, Positive B and a Negative Control. In addition, there is a Built In procedural control which consists of a Positive Control indicated by the appearance of a blue band on the test strip and a Negative Control indicated by a red background color changing to a light pink/white background color. The Built In procedural control is documented with each patient test. QuickVue Influenza Test does not differentiate between Influenza A and B. 1. Check expiration dates on the test strips and reagents. 2. Remove 1 test strip from its protective pouch. 3. Dispense one vial of extraction reagent into an extraction tube, gently swirl to mix. 4. Place the Positive A Control swab into the extraction tube, rotate the swab 3 times in the solution, then press the swab on the side of the extraction tube as the swab is removed. 5. Discard the swab in a biohazard bin or sharps container. 6. Place the test strip into the extraction tube, with the arrows pointing down. 7. Wait 10 minutes to read the results, do not handle or move the test strip during this time. 8. Record the QC results on the External QC log, along with the lot numbers and expiration dates of the newly opened product and control solutions. 9. Repeat steps 2 through 8 using the Positive B and Negative Control swabs. 10. Write date of QC and initials on the box to indicate that the box has passed QC. If QC fails, remove the product from use, return to Material Services, and note on log. 10. The Built In procedural control is documented with every patient test. 11. A Built In Positive Control is incorporated in each test strip. It is the appearance of a blue band in the upper region of the strip. 12. A Built In Negative Control is the clearing of a red background color to a light pink/white background. 13. Record the procedural QC results on the Patient Control Log with each patient test. 14. If procedural QC fails, remove the product from use, return to Material Services. Name: Unit : POCT Waived Competency _DEC 2010 (2)_AUG_2011 (2).doc 5 of 7

BINAX NOW RSV Test QC consists of performing 2 external procedural controls each time a new box of 10 BINAX NOW RSV test devices are opened. The external procedural control consists of Positive and a Negative Control. The Built In procedural control consists of a Positive Control indicated by the blue control band changing to pink and the Negative Control indicated by the background clearing to a light pink / white color. The Built In procedural control is documented with each patient test. 1. Check expiration dates on the test devices and reagents. 2. Remove 1 test device from its protective pouch 3. Twist the vial cap off the elution solution vial. 4. Place the Positive control swab into the test vial, rotate the swab 3 times in the solution, then press the swab on the side of the extraction tube as the swab is removed. 5. Discard the swab in a biohazard bin or sharps container. 6. Fill a pipette by firmly squeezing the top bulb and placing the pipette tip into the liquid sample. 7. SLOWLY add the contents of the pipette to the MIDDLE of the white sample pad, by the arrow. 8. Immediately peel off the brown adhesive liner from the test device, close the device. 9. Keeping the device horizontal, read results in the window 15 minutes after closing the device. 10. Record the results on the External QC log sheet. 11. Repeat steps 2 through 10 for the Negative Control. 12. Write date of QC and initials on the box to indicate that the box has passed QC. If QC fails, remove the product from use, return to Material Services, and note on log. 13. The Built In procedural control is documented with each patient test. 14. A Built In Positive Control is incorporated in each test strip. It is the change of the blue control band to pink. 15. A Built In Negative Control is the background of the test window clearing to light pink / white. 16. Record the procedural QC results on the Patient Control log, along with each patient test. 17. If procedural QC fails, remove the product from use, return to Material Services. Name: Unit : Signify Strep A - QC consists of performing 2 External procedural controls and documenting the extraction reagent color change, each time a new test kit, a new bottle of reagent, or a new POCT Waived Competency _DEC 2010 (2)_AUG_2011 (2).doc 6 of 7

canister of dipsticks is opened. The External procedural controls consist of a Positive Control indicated by 2 red lines and a Negative Control indicated by 1 red line in the control region on the test strip. The External procedural control is documented on the External QC log. The Internal procedural control is indicated by a red line in the control region, a clear background in the test region, and a color change with the extraction reagent. The Internal Procedural Control is documented with each patient test on the Patient Control log. 1. Check expiration dates on the test dipsticks and reagents. 2. Dispense 4 drops of Reagent 1 into the extraction tube. 3. Dispense 4 drops of Reagent 2 into the same tube. The solution must turn yellow. 4. Add 1 drop of Positive Control into the extraction tube. 5. Place a sterile swab into the tube and rotate 10 times using a circular motion so liquid is expressed and absorbed. 6. Allow solution to stand for 1 minute. 7. Gently squeeze the swab firmly against the tube to expel as much liquid as possible. 8. Discard the swab in a biohazard bin. 9. Remove the test dipstick from canister and immediately recap the canister. 10. Place the test dipstick into the tube with the arrows pointing down. 11. Read the results in 5 minutes, do not handle or move the test stick during this time (do not read after 10 minutes). 12. Positive Results: Two red lines, one in the test region and the other in the control region. 13. Document results on the Signify Strep A External QC log. 14. Repeat steps 2 through 14 for the Negative control. 15. Negative Results: One red line in the control region. 16. Invalid test results: No red line in the control region. 17. Write date of QC and initials on the test kit box & QC d bottles of reagents to indicate that the kit, and opened reagent have passed QC. If QC fails, repeat the test. If it fails again, return the box to Material Services, and note on log. 18. Write open date, expiration date (12 months after initial opening) & initials on the QC d dipstick canister. 19. Internal Procedural Control. Follow steps above except do not use the liquid controls provided. Use a throat swab specimen. 20. A Positive Internal Procedural control is indicated by the appearance of a red line in the control region. 21. A Clear Background in the test area ensures that the reagents are working properly. 22. Document procedural control results with each patient test on the Signify Strep A Patient Control Log. 23. If the procedural QC fails, remove the product from use and return to Material Services. POCT Waived Competency _DEC 2010 (2)_AUG_2011 (2).doc 7 of 7