How To Choose A Total Organic Carbon Analyzer



Similar documents
Phoenix Apollo Laboratory TOC Analyzers and Services Designed To Meet Your Needs

THE CONDUCTIVITY OF LOW CONCENTRATIONS OF CO 2 DISSOLVED IN ULTRAPURE WATER FROM C

The photoionization detector (PID) utilizes ultraviolet

Trace Gas Exchange Measurements with Standard Infrared Analyzers

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

Title: Standard Operating Procedure for Thermo-Miran SapphIRe portable gas analyzer

INFRARED SPECTROSCOPY (IR)

The Sievers 900 Series TOC Analyzers

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

On line Analysis of Organic in Water

Effects of Temperature, Pressure and Water Vapor on Gas Phase Infrared Absorption by CO 2

Conductivity Sensor Calibrations to Meet Water Industry Requirements

m/z

Chapter 1: Moles and equations. Learning outcomes. you should be able to:

LACHAT METHOD NUMBER D Rev 1, 21 March 2011 SCOPE AND APPLICATION Approximately g CN/L g CN/L. 09e

Analytical Chemistry Lab Reports

A Comparison between EPA Compendium Method TO- 15 and EPA Method 8260B for VOC Determination in Soil Gas

Name: Class: Date: 2 4 (aq)

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry

Solid Phase Extraction Products PAGE: 1. Introduction of Solid Phase Extraction (SPE) Why Choose Nano-Micro Tech SPE

Ultraviolet Spectroscopy

Cadmium Reduction Method Method to 30.0 mg/l NO 3 N (HR) Powder Pillows or AccuVac Ampuls

Introduction to Fourier Transform Infrared Spectrometry

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

DETERMINATION OF TOTAL CARBON, TOTAL ORGANIC CARBON AND INORGANIC CARBON IN SEDIMENTS

Ion Selective Electrodes

Infrared Spectroscopy 紅 外 線 光 譜 儀

FP628. Nitrogen / Protein Determination by Combustion. Rev 1-6/8/11

4.2 Bias, Standards and Standardization

5. Which temperature is equal to +20 K? 1) 253ºC 2) 293ºC 3) 253 C 4) 293 C

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Sources of TOC in Deionized Water

Supplementry Discussion Topic: Advantages and disadvantages of current analytical approaches and the best carbon pair for you

CD-Pxx-00-1 Series Duct Mount CO 2 Transmitter

Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC

FTIR Instrumentation

The Fundamentals of Infrared Spectroscopy. Joe Van Gompel, PhD

High Purity Water Resistivity/ Conductivity Measurement

Hydrogen Exchange Resin. Steam Purity Analysis

CHAPTER 7 THE DEHYDRATION AND SWEETENING OF NATURAL GAS

Physical & Chemical Properties. Properties

Gas sensors for greenhouse measurements

MOLES AND MOLE CALCULATIONS

EXPERIMENT 5. Molecular Absorption Spectroscopy: Determination of Iron With 1,10-Phenanthroline

1A Rate of reaction. AS Chemistry introduced the qualitative aspects of rates of reaction. These include:

G4 ICARUS HF. Innovation with Integrity. Simultaneous Determination of Carbon and Sulfur in Solids. Combustion Method

QUANTITATIVE INFRARED SPECTROSCOPY. Willard et. al. Instrumental Methods of Analysis, 7th edition, Wadsworth Publishing Co., Belmont, CA 1988, Ch 11.

Measurement by Ion Selective Electrodes

UVC LEDs for. Environmental Monitoring

Research for leachables of nuclear grade cation exchange resin

Experiment #5: Qualitative Absorption Spectroscopy

NITRIC OXIDE and NITROGEN DIOXIDE 6014

ZETA POTENTIAL ANALYSIS OF NANOPARTICLES

Phenolphthalein-NaOH Kinetics

Wastewater Reuse. Typical treated wastewater is:

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

Summer Holidays Questions

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

Application Note AN1

SOLAR CELLS From light to electricity

Boiler Control Solution. Boiler Control Solution. Instruments and Solution for Automatic Boiler Control LF3BUSS02-00EN.

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

A Potentiometric Analysis of Fluoride Ion in Toothpaste

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

Review - After School Matter Name: Review - After School Matter Tuesday, April 29, 2008

Alarm and Detection/Suppression

Paper No APPLICATION OF EQCM TO THE STUDY OF CO2 CORROSION

Chapter 2: The Chemical Context of Life

Elemental Analyses by ICP-AES

4. It is possible to excite, or flip the nuclear magnetic vector from the α-state to the β-state by bridging the energy gap between the two. This is a

Balancing chemical reaction equations (stoichiometry)

OEM Optical Competences. Solutions for Optical OEM Applications in Liquid Analysis.

2. DECOMPOSITION REACTION ( A couple have a heated argument and break up )

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

DIODE LASER BASED PHOTOACOUSTIC SYSTEM FOR ATMOSPHERIC WATER VAPOR MEASUREMENTS

Unit 5 Practice Test. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

Hygro-Thermometer + InfraRed Thermometer Model RH101

ABSTRACT INTRODUCTION

Chapter Test A. Elements, Compounds, and Mixtures MULTIPLE CHOICE. chemically combined? MIXs2 a. element b. compound c. mixture d.

IB Chemistry. DP Chemistry Review

DETERMINACIÓN DE ESTRUCTURAS ORGÁNICAS (ORGANIC SPECTROSCOPY) IR SPECTROSCOPY

Inferred ph in Steam Plant Water Chemistry Monitoring

ph: Measurement and Uses

SUCRALOSE. White to off-white, practically odourless crystalline powder

GUIDELINES FOR LEACHATE CONTROL

ASN Dialysis Advisory Group ASN DIALYSIS CURRICULUM

Sketch the model representation of the first step in the dissociation of water. H 2. O (l) H + (aq) + OH- (aq) + H 2. OH - (aq) + H 3 O+ (aq)

Introduction to HPLC. Basic Module in Bioorganic Chemistry January 16, 2007 Johannes Ranke. Introduction to HPLC p.1/17

This chapter is devided into two sections:

PATHOGEN DETECTION SYSTEMS BY REAL TIME PCR. Results Interpretation Guide

Deployment of networks of innovative water quality sensors for distribution network monitoring Joep van den Broeke (Ph.D.)

- 1 - BISC 367 Plant Physiology Laboratory SFU

Fiber Optics: Engineering from Global to Nanometer Dimensions

Upon completion of this lab, the student will be able to:

Effective Deoxygenation by a Hybrid Process Combining Gas Transfer Membranes with Catalytic Oxygen Reduction

DEGASSED CATION CONDUCTIVITY MEASUREMENT

Transcription:

Detection Selection for TOC Analysis: Analytical Considerations for Cleaning Validation. Applications Note By: Stephen Lawson and Brian Wallace The task of choosing a Total Organic Carbon (TOC) analyzer for cleaning validation and purified water testing brings one to consider the many techniques currently on the market. This becomes more difficult when faced with understanding that TOC analyzer manufacturers may use different detection techniques, which could affect the analytical data. This article highlights some analytical differences between the two major TOC detection techniques and offers suggestions for a process to base the choice upon the user s unique needs. A comparison of two commonly used techniques, Non-Dispersive Infrared (NDIR) and, will be given based on sample matrices. Background Conductivity The conductivity method, this includes direct and, measures the conductivity of the sample before and after it is oxidized. The differential measurement is attributed to the TOC of the sample. During the sample oxidization phase, Carbon Dioxide (CO 2 ) (directly related to the TOC in the sample) and other gases are formed. The dissolved CO 2 forms a weak acid, thereby changing the conductivity of the original sample proportionately to the TOC in the sample. In this technique, it is assumed that only CO 2 is present and, if true, the TOC of the sample may be validated by calculating by the differential measurement. Depending on the chemical species present in the sample and their individual products of oxidation, they may present either a positive or a negative interference to the actual TOC value, resulting in commensurate analytical error. TOC analyzers that employ direct conductivity detectors offer the simplest and most compact design available. However, over 50 ppm/c TOC conductivity measurements are not uniformly proportional to the TOC of the sample and vary widely with the specific carbon-containing species present, thus contributing significant error. (1) The conductivity compensation errors involving temperature and TOC concentration are little known but are of significant importance. As it is often not practical to ascertain all the chemical constituents of an analyte and measure their effects, it is equally unlikely to derive a valid algorithm compensating for both the TOC concentration conductivity error and the error deriving from temperature effects, since conductivity temperature effects are also dependent on chemical and TOC concentrations. (2) A different approach to improving the accuracy of TOC analysis using conductivity has incorporated the use of hydrophobic gas permeation membranes to allow a more selective passage of the dissolved CO 2 gas to the zero water for subsequent conductivity analysis. While this has solved certain problems, membranes have their own particular limitations. Some of these limitations include clogging, true selectivity, and a location for secondary chemical reactions that are prone to promote false negatives, a condition far more severe than false positives in critical applications. Micro leaks, flow problems, dead spots, microbial growth (blockage) are also potential problems. Certain amines will pass through membranes and add to the conductivity of the water loops. Most disconcerting is the inability of membrane methods to recover to operational performance after an overload condition arises that overranges the instrument. Often these instruments take hours before returning to reliable service and recalibration. Certain amines will pass through membranes and add to the conductivity of the water loops. Small changes in ph are also well known contributors to inaccuracy. The interference of the non-fully oxidized organics would remain, presenting both the error of incomplete oxidation and the consequent CO 2 detection interference. Sales/Support: 800-874-2004 Main: 513-229-7000 4736 Socialville Foster Rd., Mason, OH 45040 Copyright 2008 Teledyne Tekmar Company. All Rights Reserved.

NDIR Detection NDIR detectors use Infrared (IR) energy to detect the presence of CO 2. An IR beam is transmitted through the sample chamber as the sample gas containing CO 2 fills the chamber. Pressurized front and rear cells connected by a mass flow sensor are located within the detector. An optical filter allows only light of a predetermined wavelength to reach the detector cells from the IR source. When IR energy passes through CO 2 gas, it creates a unique adsorption spectrum making CO 2 distinguishable from other gases. To collimate the IR light through the sample chamber and to increase optical efficiency, the light source is surrounded by a parabolic reflector assembly usually gold lined. Any change in gas flow to the cells changes the pressure within each cell individually. This pressure difference is detected by the mass flow sensor, which then emits an electrical signal proportional to the magnitude of the flow. As this occurs, the instrument monitor displays a single point on a graph corresponding to the emitted electrical signal usually in millivolts (mv). This point represents the amount of CO 2 inside the detector only at that particular moment. As the adsorption of the infrared light is measured over time, the amount of CO 2 inside the detector increases and decreases as the sample gas flows through the detector. Displayed together the plotted points relate to the traditional flow-through cell bell shaped curve. The CO 2 sample result is calculated by the mathematical integration of the area underneath this curve. The NDIR detection technique offers a more practical, interference-free method for detecting CO 2 in TOC analysis. This technique measures the CO 2 in the gas phase, eliminating the interference effects of other compounds that remain in the sample. (3) Static Pressure Concentration (SPC) Like flow through cell NDIR detectors, an SPC-NDIR detector contains an IR light source and an optical filter. However, unlike other detectors, as the oxidation products are swept into the SPC detector the exit valve is closed allowing pressurization to occur. Once the gases inside the detector have reached equilibrium at a predetermined pressure setting, a Tungsten light source emits a single IR beam through the CO 2 gas. This beam reflects off a gold plated mirror to the detector. Prior to reaching the detector, a Fabry-Perot Interferometer (FPI) filters the light beam at an absorbance wavelength that is specific for CO 2 at 4.3 microns (μm). Under pressure and at equilibrium all of the CO 2 is then analyzed. The pressure required for static read is typically between 30-60 psig and defined in programmed methodology. Inside the SPC detector is a thermopile, which is a temperature sensor. It turns thermal energy into an electrical signal. After the CO 2 is evacuated, the same Tungsten light source sends a second beam towards the detector. This second beam is the reference beam. The FPI filters that beam at an absorbance wavelength of 3.9 μm, which is non-specific for CO 2. The thermopile measures the difference between the signal of the infrared beam that has adsorbed CO 2 and the reference beam. This difference corresponds to the amount of CO 2 inside the detector and thereby the sample aliquot, as seen in Figure 1. The Fabry-Perot Interferometer is a silicon-based micro-machine (semi-conductor). When an electrical current is applied to the semi-conductor, different absorbance wavelengths can be selected. This in turn, allows different regions of infrared spectra to be chosen for absorbing and non-absorbing CO 2 regions. Figure 1 A display of CO 2 from a NDIR detector Static Pressure Concentration (SPC) detector technology, as used in the New Teledyne Tekmar Fusion TOC Analyzer.

12 8 6 4 2 1 ppm/c + 0.8% NaCl 2 ppm/c + 0.8% NaCl 5 ppm/c + 0.8% NaCl 10 ppm/c + 0.8% NaCl 20 ppm/c + 0.8% NaCl Figure 2. A comparison of Two TOC Analyzers using vs. SPC-NDIR Detection Technology for analysis of TOC in 0.8% NaCl at increasing TOC concentrations. Each analyzer was calibrated to its manufacturing specifications prior to analysis. 15 Detector Comparison of Pharmaceutical Compound Recoveries 5 2.8 ppm/n Sulfaguanidine 2.5 ppm/s Sulfaguanidine 0.6 ppm/n Cimetidine 10 ppm/n Aspartic Acid 10 ppm/c Chloraphenicol 1 ppm/c Triflupromazine Figure 3 A Comparison of Pharmaceutical Compounds using vs. SPC-NDIR Detection Technology. Each analyzer was calibrated to its manufacturing specifications prior to analysis.

Detector Comparison of 2.0 ppm KHP in Various Concentrations of Azide Interference 15 Membrance Conductivity 5-5 2 ppm/c KHP Only + 2 ppm/n NaN3 + 5 ppm/n NaN3 + 25 ppm/n NaN3 + 50 ppm/n NaN3 2 ppm/c KHP Only - -15 Addition of Various Azide Concentrations (Samples run in order displayed on chart left to right) Figure 4. A Detector Comparison of TOC Analysis with Increasing Amounts of Azide present in an aqueous sample. Each analyzer was calibrated to its manufacturing specifications prior to analysis. Detector Comparison of 2.0 ppm/c KHP in Various Concentrations of Nitrate Interference Membrance Conductivity SPC Detection - -20-30 -40 2 ppm/c KHP Only + 2 ppm/n NaNO3 + 5 ppm/n NaNO3 + 25 ppm/n NaNO3 + 50 ppm/n NaNO3 2 ppm/c KHP Only Addition of Various Nitrate Concentrations. (Samples run in order displayed on chart left to right) -50 Figure 5. A Detector Comparison of TOC Analysis with increasing amounts of Nitrate Compounds present in an aqueous sample. Each analyzer was calibrated to its manufacturing specifications prior to analysis.

Conclusion A comparison of brine sample analysis at a concentration of 0.8% sodium chloride shown in Figure 2, demonstrates the effectiveness of proven UV /Persulfate technology combined with SPC-NDIR detection. In contrast, SPC-NDIR technology by far surpasses the ability of membrane conductivity technology to analyze brines. A comparison of hard to oxidize pharmaceutical compounds, due to their complex molecular structure and varying levels of nitrogen, sulfur, and carbon is shown in Figure 3. As illustrated, the membrane conductivity detector did not effectively recover these compounds as compared to the SPC NDIR detector. In Figures 4 5, nitrogen chemical species in the sample and their individual oxidation product interfere negatively with the membrane conductivity TOC recovery, as the nitrogen concentrations increase. 4 Whereas, the SPC NDIR detection technology achieved superior recovery and accuracy for all compounds studied. As seen in this study, the SPC NDIR technology offers the best TOC analysis performance in a wide range of sample water matrices. References 1. Light, T.S., Kingman, B., Bevilacqua, A.C., "The Conductivity of Low Concentrations of CO 2 Dissolved in Ultrapure Water From 0-100 C", 209th American Chemical Society National Meeting, Anaheim, CA, April 2-6, 1995 2. Bevilacqua, A.C., "The Effect of Temperature, Temperature Error, and Impurities on Compensated Conductivity Measurements", 16th Annual Semiconductor Pure Water and Chemicals Conference, Santa Clara, CA, March 3-6, 1997. 3. Wallace, B., Stevens, R., Evaluating Oxidation and Detection Technologies, Pharmaceutical Formulation March/ April 2004, 76 77. 4. CheckPoint A Breakthrough TOC Sensor and Its Role In UPW Applications, White Paper, GE Water & Process Technologies Analytical Instruments.