HA7402C PHASE NOISE ANALYZER

Similar documents
APSYN420A/B Specification GHz Low Phase Noise Synthesizer

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent E5100A Network Analyzer

PERF10 Rubidium Atomic Clock

R&S ZNBT8 Vector Network Analyzer Specifications

Multi-Range Programmable DC Power Supplies 9115 Series

INTELLIGENT INTERACTIVE SYNTHESIZER SURFACE MOUNT MODEL: MFSH

Multi-Range Programmable DC Power Supplies 9115 Series

Agilent P940xA/C Solid State PIN Diode Switches

iva Cable & Antenna Analyzer

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

How To Use A Sound Card With A Subsonic Sound Card

iva Cable & Antenna Analyzer

DCS Series 1 kw, 1.2 kw, & 3 kw

R&S ZNC Vector Network Analyzer Specifications

Research RF Sputtering Packages

USB Smart Power Sensor

LT-82 Stationary IR Transmitter

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

R&S ZVA Vector Network Analyzer Specifications

Ideal for high dynamic range measurements from compression to noise floor

One Port Network Analyzer

Impedance 50 (75 connectors via adapters)

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

R&S ZCxxx Millimeter-Wave Converters Specifications

1. SAFETY INFORMATION

Signal and Tracking Generator

SOUND LEVEL METER 94405

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

USB Smart Power Sensor

R&S SMZ Frequency Multiplier Specifications

Keysight N9320B RF Spectrum Analyzer

RFSPACE CLOUD-IQ #CONNECTED SOFTWARE DEFINED RADIO

HDO700 P FIBRE OPTIC TRANSMITTER

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Optimizing VCO PLL Evaluations & PLL Synthesizer Designs

Agilent. E5071C ENA Network Analyzer. E5092A Configurable Multiport Test Set. Data Sheet

HIGH RELIABILITY POWER SUPPLY TESTING

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Keysight N4877A Clock Data Recovery and Demultiplexer 1:2

Telephone- and leased line modem for industrial applications TD-36

High Power Programmable DC Power Supplies PVS Series

Keysight Technologies N9320B RF Spectrum Analyzer

DSA800 Series Spectrum Analyzer

Model CFA-24 Transparent Cable Farm Automation Switch

NGSS Data Consolidator (DC)

1.44 kw Programmable DC Power Supplies XLN Series

NEW. EVEN MORE data acquisition and test stand automation

USB Smart Power Sensor

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

USB I/O CONTROL BOX 8 relays, 8 digital I/O lines and 8 HV inputs

NI USB-5681 RF Power Meter Specifications

User's Guide. Integrating Sound Level Datalogger. Model Introduction

DP800. Programmable Linear DC Power Supply RIGOL TECHNOLOGIES, INC.

Rack mounted telephone- and leased line modem for industrial applications

R&S ZVA-Z75, -Z110, -Z140, -Z170, -Z220, -Z325, -Z500 Converters Quick Start Guide

5 in 1 DVB-T Transmitter & Dual Cast Agile Digital Transposer TV EQUIPMENT

Raptor RXi Ultra-fast scanning Countersurveillance Receiver

TOTALLY SOLID STATE NON-DIRECTIONAL RADIO BEACONS khz

Model GS Port Node 1 GHz with 40/52 MHz split

Name Description Model Number. Parameters Min. Typ. Max. Note. Vaux Voltage 9.8 V 12 V 13.2 V Auxiliary Supply Voltage

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

airmax Wireless Broadband CPE Datasheet Models: AG-HP-2G16, AG-HP-2G20, AG-HP-5G23, AG-HP-5G27 High Performance, Long Range Integrated InnerFeed CPE

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

khz to 2.7 GHz Spectrum Analyzer

FREQUENCY RESPONSE ANALYZERS

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

DS 600. A contact free flux gate based current measurement sensor 600A rms

Features, Benefits, and Operation

USER GUIDE. For more information visit

Physical Specifications (Custom design available.)

IntesisBox KNX Mitsubishi Heavy Industries AC

Uninterruptible Power Supply

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

Measurement, analysis, and monitoring of RF signals

Agilent Test Solutions for Multiport and Balanced Devices

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Cisco Model EPC2100 EuroDOCSIS 2.0 Cable Modem

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

Agilent 8753ET/8753ES Network Analyzers

DRM compatible RF Tuner Unit DRT1

PSC RF Multi SR Six Pack

Industrial Bar Code Scanners

VCL-MX Version 6 DXC 80 T1, 120Mbps Digital Access Cross Connect Switch. System Guide. VCL-MX Version 6 - T1 120Mbps Voice & Data Multiplexer

LOXONE 12 Channel Amplifier

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Product Specifications

A-307. Mobile Data Terminal. Android OS Platform Datasheet

3500/22M Transient Data Interface

Wideband Driver Amplifiers

Agilent 8762/3/4A,B,C Coaxial Switches

4-Channel Thermometer / Datalogger

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

INTRODUCTION. Please read this manual carefully for a through explanation of the Decimator ProRackG and its functions.

Chassis, Power Supply, and Element Management

Transcription:

REAL TIME CROSS CORRELATION HA7402C 10 MHz to 6GHz Optional to 20GHz Cross Correlation Fast Data Acquisition DATA SHEET April 2016 RoHS

PRODUCT SUMMARY The HA7402C tunable phase noise analyzer responds to industry demands for a no frills phase noise measurement system that is highly reliable and intuitive while offering measurement speeds that eliminate bottlenecks on manufacturing test lines. The HA7402C is also an incredibly cost effective solution for R&D, offering measurement floors below -190dBc/Hz. The core engine combines the best of traditional analog phase noise measurement front-ends (being virtually spur free) with the latest technology in cross correlation analysis. The digital analysis system leverages a proprietary DSP with a powerful cross correlation engine. External LOs are used with this unique architecture to achieve the lowest phase noise floors as well as blazing fast measurement speeds. Two separate LOs are necessary, as the engine requires non-coherent signals in order to cross correlate. The integrated frequency counters and power meters make the use of external LOs straight forward with a fully automated calibration routine. Phase noise measurements do not benefit from modular analyzer architectures. Holzworth s fully shielded, fan-less 1U chassis completely eliminates ground loops and troublesome microphonics for uncompromising performance when compared to traditional rack and stack style systems. ANSI Z540 CALIBRATED ACCURACY SIMULTANEOUS AM/PM MEASUREMENTS ULTRA LOW PHASE NOISE FLOORS HIGH SPEED DATA ACQUISITION AUTOMATED - ABSOLUTE & RESIDUAL 3 YEAR MANUFACTURER WARRANTY Email: sales@holzworth.com All rights reserved. Page 2 of 13

PRODUCT SUMMARY - BLOCK DIAGRAM Figure 1: HA7402C Front End Block Diagram Email: sales@holzworth.com All rights reserved. Page 3 of 13

SPECIFICATIONS - ELECTRICAL The HA7402C is designed for high speed and precise phase noise measurements. The specifications outlined here capture the baseline performance and features that are currently available from the HA7402C phase noise analyzer. The highly reliable hardware is capable of additional functionality for custom requirements. Inquire with Holzworth Instrumentation or your local sales representative. RF INPUT (DUT/LO) RF Input Connector RF Input Frequency Range (standard) RF Frequency Extension (>20GHz) RF Input Measurement Level Input Damage Level SPECIFICATION SMA (female), 50 ohm 10 MHz to 6 GHz Option OPT-DUT20 enables >20GHz frequency measurements 0 dbm to +20 dbm +22 dbm Input VSWR < 2.0:1 PHASE NOISE MEASUREMENTS SPECIFICATION RF Input Frequency Range 10 MHz to 6 GHz RF Frequency Extension (>20GHz) RF Tracking Range Offset Frequency Range Phase Noise Uncertainty 1 Hz to 1 khz offset 1 khz to 1 MHz offset 1 MHz to40 MHz offset Option OPT-DUT20 enables >20GHz frequency measurements ±10ppm (typical), ± 5ppm (specified) 1 Hz 40 MHz (Settable to 0.1Hz Offset) ± 4 db (to be updated with improved uncertainty resulting from z540.1 calibration statistics) ± 2 db (to be updated with improved uncertainty resulting from z540.1 calibration statistics) ± 2 db (to be updated with improved uncertainty resulting from z540.1 calibration statistics) x Correlation See pages 5-7 Measurement (Sample) Time See Table 1 Email: sales@holzworth.com All rights reserved. Page 4 of 13

TABLE 1: PHASE NOISE MEASUREMENT SPEED (SAMPLE TIME) Frequency Offset Range Sample Time 10kHz - 40MHz 1kHz - 40MHz 100Hz - 40MHz 10Hz - 40MHz 1Hz - 40MHz 10x period of minimum offset frequency. TABLE 2: x CORRELATIONS vs. PHASE NOISE IMPROVEMENT Improvement factor: db = 5logN (N = No. of correlations) Number of Correlations 1 10 100 1,000 10,000 db Improvement 0dB 5dB 10dB 15dB 20dB INTERNAL TIME BASE (10MHz Reference) Frequency Uncertainty / Stability Frequency Temperature Effects Frequency Aging Rate 10MHz External Lock Range SPECIFICATION < ± 1Hz at 10MHz (±100 ppb) At time of shipment. Factory calibrated at +21C. < 10ppb < 100ppb/yr ± 20Hz (typical), ± 10Hz (specified). 10MHz is for frequency counters only. LO MODES MODE External LO Mode User supplied LO sources. Auto calibration of LO sources and auto phase lock. Pages 10-11. Email: sales@holzworth.com All rights reserved. Page 5 of 13

REAL TIME CROSS CORRELATION PROCESSING ADVANTAGE HA7402C The HA7402C processes data across the entire measurement offset bandwidth in real time. Data at higher frequency offsets undergoes continuous processing while the system is accumulating data closer to the carrier. This results in improved phase noise floor performance at higher offset frequencies. The plot below demonstrates the phase noise improvement that can be expected based on the minimum frequency offset chosen. Email: sales@holzworth.com All rights reserved. Page 6 of 13

CONFIGURATION FRONT PANEL The HA7402C allows for a high level of measurement flexibility to accommodate different test scenarios by allowing the user access to various system inputs points. However, only the DUT Input port is necessary for making straight forward absolute phase noise measurements of a frequency source. Front Panel Connector(s) Type DUT Input Frequency Range (standard) Power Level Range Input Damage Level DUT Tune Voltage Voltage Tune Range Max Current DUT Power Supply Voltage Supply Range Maximum Current LO1/LO2 Input(s) Frequency Range (standard) Power Level Range Input Damage Level LO1/LO2 Tune Voltage Voltage Tune Range Max Current Tuning Sensitivity ch1/ch2 Splitter Bypass Input(s) Frequency Range (standard) Power Level Range Input Damage Level ch1/ch2 Splitter Bypass Output(s) ch1/ch2 Baseband Input(s) Frequency Range Power Level Range Input Damage Level SPECIFICATION SMA (3.5mm), 50ohm 10MHz to 6GHz 0dBm to +20dBm > +22dBm For Vcc control of some DUTs. Limited current for operation as a power supply. -10V to +10V 5mA Integrated power supply. 0V to +12V 300mA Connect to LO1/LO2 Output(s) for standard operation. 10MHz to 6GHz 0dBm to +20dBm > +22dBm For independent Vcc control of external LO sources during External LO Mode of operation. -10V to +10V 5mA TBD Allows user to bypass DUT power splitter for direct access to the FFT engine. Connect to ch1/ch2 Splitter Bypass Output(s) for standard operation. 10MHz to 6GHz 0dBm to +14dBm > +16dBm Connect to ch1/ch2 Splitter Bypass Input(s) for standard operation. DC to 40MHz ± 1Vdc ± 2Vdc, or 50mA (whichever is greater) Email: sales@holzworth.com All rights reserved. Page 7 of 13

CONFIGURATION (continued) REAR PANEL Reference Output Port Connector Type Output Frequency Output Level Output Waveform Reference Input Port Connector Type Input Frequency Input Level AC Power Input Connector Type AC Input Rating Data I/O Interface Connectivity Storage SPECIFICATION SMA, 50ohm 10MHz ±10Hz +5dBm ±2dBm Sinusoid ONLY FOR FREQUENCY COUNTERS - DOES NOT AFFECT MEASUREMENT SENSITIVITY SMA, 50ohm 10MHz ±10Hz 0dBm to +10dBm (Sinusoid or Square) IEC 320-C13 100-240VAC, 47-63Hz. Specify country at time of order. USB B-Type (virtual comm. port), Ethernet, RS-232, GPIB SD Card Reader Figure 3: HA7402C Communication Ports Email: sales@holzworth.com All rights reserved. Page 8 of 13

MECHANICAL DIMENSIONS The HA7402C comes complete in a 1U high, rack mountable chassis. The chassis is a fan-less design to eliminate microphonics. A universal rack mount bracket kit is an available accessory (Part No.: RACK-1U). Mechanical dimensions are listed in inches (and millimeters). 17.00 (432) TOP 15.00 (381) 1.75 (44.45) Email: sales@holzworth.com All rights reserved. Page 9 of 13

STANDARD AC SUPPLY The HA7402C utilizes an ultra-clean AC switching power supply. Units ship with a standard AC supply cable that is used to provide power to the instrument. ENVIRONMENTAL Operating Environment Temperature Humidity Altitude Vibration Storage (Non-Operating) Temperature Humidity Altitude Vibration SPECIFICATION (by design) +10C to +40C RH 20% to 80% at wet bulb temp. <29C (non-condensing) 0 to 2,000m (0 to 6,561 feet) 0.21 G-rms maximum, 5Hz to 500Hz -10C to + 60C RH 20% to 80% at wet bulb temp. <40C (non-condensing) 0 to 4,572m (0 to 15,000 feet) 0.5 G-rms maximum, 5Hz to 500Hz Email: sales@holzworth.com All rights reserved. Page 10 of 13

OPTIONS & ACCESSORIES Holzworth offers options and accessories to optimize the analyzer for an intended application. Specify all required options and/or accessories when requesting a quotation or placing a purchase order. PART No. CLASSIFICATION OPT-DUT20 Enables DUT measurements to >20GHz via Internal LO Mode OPTION CASE-1U Ruggedized Carrying Case with TSA security lock ACCESSORY RACK-1U 19 Rack mount bracket kit for HA7000 Series. L rear bracket. ACCESSORY RACK2-1U 19 Rack mount bracket kit for HA7000 Series. Straight rear bracket. ACCESSORY INCLUDED HARDWARE AND CERTIFICATIONS Each product delivery includes specific, standard hardware and certifications. TYPE COMMENTS HARDWARE HA7402C DELIVERABLE HARDWARE AC POWER CABLE (Specify country at time of order) DELIVERABLE CERTIFICATE ANSI z540.1 CALIBRATION CERTIFICATE DELIVERABLE WARRANTY 3 YEAR MANUFACTURER S WARRANTY NON-APPLICABLE CERTIFICATE CERTIFICATE CERTIFICATE CE COMPLIANCE CERTIFICATE DIRECTIVE: 2004/108/EC, TEST STANDARD: EN 61326-1: 2006 RoHS COMPLIANCE CERTIFICATE DIRECTIVE: 2002/95/EC WEEE COMPLIANCE STATEMENT DIRECTIVE: 2002/96/EC WEB DOWNLOAD WEB DOWNLOAD WEB DOWNLOAD Email: sales@holzworth.com All rights reserved. Page 11 of 13

HA7402C. OPERATION The HA7402C performs all data processing internally. Measurement settings can be changed using serial commands sent to the HA7402C using any of the included communication options (see CONFIGURATION on page 9). Alternatively, measurement results can be read from the instrument directly without requiring a specific operating system. This capability provides unparalleled operational flexibility. The hardware purchase includes a MATLAB compiled GUI for hardware operation and viewing/saving data. Each unit comes with an open license to operate the MATLAB Runtime based application on any standard PC. MATLAB Runtime is MathWorks shareware that can be used without the purchase of MATLAB. Email: sales@holzworth.com All rights reserved. Page 12 of 13

3 YEAR WARRANTY All Holzworth phase noise analyzer products come with a standard 3 year 100% product warranty covering manufacturing defects. All product repairs and maintenance must be performed by Holzworth Instrumentation. Holzworth reserves the right to invalidate the warranty for any products that have been tampered with or used improperly. Refer to Holzworth Terms & Conditions of Sales for more details. Holzworth products are proudly designed and manufactured in the USA. CONTACT INFORMATION Contact Holzworth directly for a product quotation, a product demonstration, or for technical inquiries. Holzworth Instrumentation Sales Support Phone: +1.303.325.3473 (option 1) Email: sales@holzworth.com Holzworth Instrumentation Technical Support Phone: +1.303.325.3473 (option 2) Email: support@holzworth.com www.holzworth.com RoHS Email: sales@holzworth.com All rights reserved. Page 13 of 13