36J Gas Control Product Information

Similar documents
36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Operator: Save these instructions for future use!


G670 Intermittent Pilot Ignition Controls

Your safety and the safety of others are very important.

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Fossil fuel heating equipment

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

WARNING CAUTION 21V51U-843 DESCRIPTION PRECAUTIONS

Heating Basics Gas Valve Systems

37E73A-903 & 906 INTELLI-VENT

80UHG. Service Literature

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

M/MR Modulating Valves TABLE OF CONTENTS DESCRIPTION SPECIFICATIONS. For Atmospheric, Infrared, and Direct Fired Burners

Cooling Capacity CFM in. w.c. (125 Pa)

PRODUCT DESIGN. 5. Furnace awaits call from thermostat.


Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

, User s Manual

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Installation Instructions

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

COMMERCIAL GAS DRYER

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Commercial Gas Furnace Upflow

Cooling Capacity CFM in. w.c. (125 Pa)

COMMERCIAL GAS DRYER

Your safety and the safety of others are very important.

Air Conditioning Sign-Off Sheet

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

SV9501/SV9502/SV9601/SV9602 SmartValve TM System Control

Cooling Capacity CFM in. w.c. (125 Pa)

Pilot Water Heater 6-10 Gallon

Gas Valves. Thermocouples. Pilots. Thermopiles. Water Heating WH/HVAC PRODUCT INFORMATION

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

G9MXE. Product Specifications

Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483

XV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

COMMERCIAL GAS DRYER

Commercial Gas Cooking Thermostats

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

VR46../VR86.. series COMPACT AUTOMATIC COMBINATION GAS CONTROLS APPLICATION. Contents PRODUCT HANDBOOK

SELECTION, APPLICATION AND MAINTENANCE

Model Description / Applications. Intermittent Pilot Gas Ignition Control

AFE424 SERVICE PARTS

Stainless Steel Single and Dual Circulation Kits

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

INTELLI-VENT CONTROL INFORMATION When Used On Gas, Residential, Power Vented Water Heaters

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Oil and Coolant Circulating Heating System. Model - OCSM

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model. CELTIC RSc b CUENOD. R EN - Edition 02-21/04/2005

MDT5N25 & MTD5N40 SERVICE PARTS

Communicating Controls Service Manual

F9MXE. Product Specifications

Gas Oven Repair Guide

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard


Assisted lift operated 2/2-way solenoid valves Type EV250B

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

OBSOLETE. VS8420 Millivolt Gas Valve

VX 2400 Dimmer User's Manual

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

3/2-way Solenoid Valve, direct-acting, NC or NO

Not required for most applications Not required for most applications High pressure ( provided) High pressure ( provided)

VSO MAX HP High Flow Proportional Valve

Commercial Gas Water Heater

DC Series Digital Conversion Alarm Operator s Manual

Preventing Overheated Boiler Incidents

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Service Handbook Commercial / Residential gas water heater

Universal electronic. Application: Integrates control of combustion blower and circulating fan operations for a gas warm air appliance

LPM-06 CONVERSION KIT

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

Why and How we Use Capacity Control

OPERATIONAL CHECKS & SAFETY CIRCUIT DESCRIPTION

M A N U A L

FOXAIR 60/50 ALL MODELS

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

STC 3S A Series Solenoid Valves

LOBOY 16 AIR CONDITIONERS

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Before installation it is important to know what parts you have and what the capabilities of these parts are.

OBSOLETE. VS8510,VS8520 Millivolt Gas Valve

SERVICE MANUAL FOR 6535 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

MCR1900 Media Converter 19-Slot Chassis

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

INSTALLATION INSTRUCTIONS FOR MODELS 16NG50/16LP50, 16NG60/16LP60, 20NG50/20LP50, 20NG60/20LP60, 26NG50/26LP50, 26NG60/26LP60

For installation guide see reverse of book

Transcription:

Single Stage 6J Two Stage 6J 6J Gas Control Product Information The 6J combination gas control valve is a versatile multifunction control designed to meet the requirements for use with non-piloted intermittent ignition systems (Direct Spark Ignition, Hot Surface Ignition). Models include fast and slow open single and two stage valves. These valves are also convertible for natural/lp gases. Along with its reduced size, all control adjustments and features, as well as the system interface-wiring panel, have been designed on the top surface of the control for simplified application and easy accessibility. The 6J gas control is designed to meet today s requirement for maximum capacity, smaller size and highly efficient gas systems. Features include: Patented coaxial solenoid design. Inlet and optional outlet screens help protect from debris. Controlled gasket compression. Tamper resistant screws. Built-in hose connections for simplified field service or Std. /8" NPT (optional). Conveniently located electric on-off switch. Versatile mounting. Information in this manual is provided to qualified HVAC Professionals Only for the installation and replacement of gas valves. Homeowners must contact their local HVAC Contractor for gas valve replacement. Any gas valve suspected of damage or if it has been flooded with water must be replaced immediately. There are no serviceable parts on a gas valve.

Contents Product Description Overview... General Specifications Standard Features... Optional Features... Regulator Adjustment Range... " Pressure Drop Capacity... Single Stage Model Schematic Gas Flow Diagram... Standard Open Control... 6 Slow Open Control... 6 Convertible Regulator... 6 System Applications... 7 Electrical Connections... 8 Dimensions... 8 Two Stage Model Schematic Gas Flow Diagram... 9 Standard Open Control... Slow Open Control... Electrical Connections... Dimensions... Models Available Model & Type Number Designations... R-7B

General Specifications Standard Features Inlet/Outlet screen Ambient temperature for F to 7 F Mounting (Any position) Quiet redundant Electrical shut-off Top mounted components Outlet pressure tap (/6" I.D. hose connection) Vent connection (/6" I.D. hose connection) Quick-connect terminals (/") Mounting holes for 8- screws Adjustable regulator(s) Maximum pressure (/ PSI) CSA approved Single Two V, /6 HZ.8A V, /6 HZ.A Optional Features Ground terminal Natural to LP regulator selector (convertible; single stage only) Slow open Inlet pressure tap (/6" I.D. hose connection) Right-angle outlet (bottom) Limited maximum adjustable regulator Vent fitting for /" I.D. hose (9 elbow) /8" N.P.T. Pressure taps (inlet and outlet) Flange mount [inlet and outlet (/" or /8" NPT)] Regulator Adjustment Range Valve (Stages) Pipe Sizes CSA Std. Gas.6 Sp. Gr. ( BTU/CU. FT.) LP Gas Sp. Gr. ( BTU/CU. FT.) Adjustment Range (NAT., IN. W.C.) Adjustment Range (LP., IN. W.C.) Single / x / NPT,, 6,,. -. 7. -. Two / x / NPT,,,,. -. low. -. high. -. low 6. -. high R-7B

General Specifications " Pressure Drop Capacity " PRESSURE DROP CAPACITY (/" x /" PIPE SIZE) NAT. GAS FLOW (KBTU/HR)..6.8...6.8 DIFFERENTIAL PRESSURE (IN. W.C.) Pipe Sizes (NPT) / x /." PRESSURE DROP CAPACITY CSA Std. Gas.6 Sp. Gr. ( BTU/CU. FT.), BTU/HR LP Gas Sp. Gr. ( BTU/CU. FT.) 6,8 BTU/HR R-7B

Single Stage Model Schematic Gas Flow Diagram Main Valve Regulator Cap Screw Outlet Pressure Tap Regulator Adjust Screw Redundant Solenoid Vent (Leak Limited) Inlet Pressure Tap Outlet Inlet Screen Inlet Outlet Screen Control Gas Orifice Diaphragm Opening Orifice DIAGRAM FOR ILLUSTRATION ONLY, NOT ALL DETAILS ARE INCLUDED R-7B

Single Stage Model Standard Open Control This control has a standard opening characteristic, which is suitable for a wide range of applications. It provides a fast rise to full pressure upon energizing the solenoid. Regulator LP spring conversion kits are available for this control. 6J STANDARD OPEN GAS VALVE (.9 OPENING ORIFICE).... 6 7 8 9 NOTE: TYPICAL OPENING CURVE NATURAL GAS, BTU/HR. 7" W.C. INLET /." W.C. OUTLET Slow Open Control This control has a slow opening characteristic. It provides a slow increase of gas to full pressure for smoother ignition, as may be required by some applications. There are options available: B. Very Slow Opening orifice C. Slow Opening orifice D. Intermediate Opening orifice NOTE: TYPICAL OPENING CURVE NATURAL GAS, BTU/HR. 7" W.C. INLET /." W.C. OUTLET OPENING CHARACTERISTICS WILL VARY WITH FLOW RATE AND APPLICATION. 6J SLOW B.... 6 7 8 9 Convertible Regulator 6J SLOW C.... 6 7 8 9 The convertible regulator option for this control involves a construction, which permits easy Natural to LP conversion (or vice versa) by removing, inverting and replacing the regulator cap screw. This feature easily lends itself to use in mobile homes and infra-red applications NOTE: TYPICAL OPENING CURVE NATURAL GAS, BTU/HR. 7" W.C. INLET /." W.C. OUTLET 6J SLOW D.... 6 7 8 9 6J CONVERTIBLE GAS VALVE.... 6 7 8 9 6 R-7B

Single Stage Model System Applications Hot Surface Ignition HSI CONTROL. The thermostat calls for heat and energizes the HSI control. If system is equipped with prepurge, the purge fan is energized and power will be delayed thirty seconds before application to the silicon carbide ignitor. If prepurge is not selected, the ignitor is powered within one second. The ignitor heats up and at the end of the heating period, the redundant and main valves are opened. A flame must be detected within a fixed time period or both valves close, the ignitor is turned off and the HSI control locks out unless the system is equipped with retry. Retry indicates the ignition sequence will be repeated for a total of three tries if flame is undetected or lost within seconds of ignition. Accessories: HSI control, Sense Electrode, Silicon Carbide Ignitor, Silicon Nitride Ignitor BLACK HOT LINE VOLTAGE NEUTRAL LIMIT W REDUNDANT VALVE TRANSFORMER VOLTS AC 6 Hz R THERMOSTAT MAIN VALVE FLAME SENSOR PROBE LINE VOLTAGE LOW VOLTAGE MV MV TR TH FP GND L IGN COMMON ( C ) SILICON CARBIDE IGNITOR BLACK WHITE INTEGRATED CONTROL. The A or A6 Integrated Hot Surface Ignition controls employ a microprocessor to continuously monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. Signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shut-off during normal operation. The control incorporates system fault analysis for quick gas flow shut-off, coupled with automatic ignition retry upon sensing a fault correction. LINE HOT VAC LINE NEU CIRCULATOR BLOWER Ka FLAME FP FP IGN SENSE PROBE IGNITOR HEAT COOL PARK PARK L K K b GND K7 MV GAS VALVE CIRC NEU K8 MV PS HLO K PRESSURE SWITCH HIGH LIMIT INDUCER IND IND NEU AU. LIMIT HLI R RO ROLLOUT SWITCH RO TH FMR HOT VAC FMR NEU TR C Y G W COMPRESSOR CONTACTOR COIL R Y G W THERMOSTAT System Applications Direct Spark Ignition The thermostat calls for heat and simultaneously energizes the DSI control module and gas valve solenoid. Sparks at the ignition electrodes ignite the gas at the main burner. Flame is sensed through the electrodes by the flame detection circuit and shuts off the sparking. If flame is not established within a fixed time period (lock-out time) main and redundant valves close, sparking ceases and the control module locks out. H.V. DSI CONTROL SPARK RETURN LEAD TR MV MV MAIN VALVE REDUNDANT VALVE V. Accessories: DSI control, Electrodes TH GND THERMOSTAT R-7B 7

Single Stage Model Electrical Connections () or () Optional /" Male Quick Connect Terminals For Ground Connection Dimensions 6J Standard/Slow Open Control /" x." THK. MALE SPADE TERMINALS () CONTROL I.D. LABEL REGULATOR COVER SCREW (REG. ADJ. BENEATH THIS SCREW) INLET PRESSURE POST.9 DIA. +DFT. (SET SCREW: /" HE HEAD) ACCEPT /6" ID HOSE CONNECTION.6 OUTLET PRESSURE POST.9 DIA. +DFT. (SET SCREW: /" HE HEAD) ACCEPT /6" ID HOSE CONNECTION SWITCH (SHIPPED IN "ON" POSITION) PLASTIC PLUGS ().7 SWING RADIUS.78 OUTLET /" N.P.T..69.8.68.88. INLET /" N.P.T..9 6 MOUNTING HOLES () FOR #8- THREAD FORMING SCREWS.76.69 8 R-7B

Two Stage Model Schematic Gas Flow Diagram Redundant Solenoid Hi Fire Regulator Main Valve Outlet Pressure Tap Regulator Selector Valve Lo Fire Regulator Vent (Leak Limited) Inlet Pressure Tap Outlet Inlet Screen Inlet Outlet Screen Control Gas Orifice Opening Orifice Diaphragm DIAGRAM FOR ILLUSTRATION ONLY, NOT ALL DETAILS ARE INCLUDED R-7B 9

Two Stage Model Standard Open Control This control has dual outlet pressure levels, which is desirable for high efficiency applications. It provides a fast rise to first stage pressure upon energizing the single stage solenoid. Then, if more pressure level is required to satisfy heating requirement, energizing a second stage solenoid can attain a higher pressure level. Regulator LP spring conversion kits are available for both pressure levels on this control. 6J TWO STAGE GAS VALVE.... 6 7 8 9 NOTE: TYPICAL OPENING CURVE NATURAL GAS, BTU/HR. 7" W.C. INLET /." W.C. OUTLET Slow Open Control This control has dual outlet pressure levels, which is desirable for high efficiency applications. It provides a slower rise to first stage pressure upon energizing the single stage solenoid. If more pressure is required to satisfy heating requirement, energizing a second stage solenoid can attain a slower rise to a higher pressure level. This slower rise condition is dependent on the size of orifice used. Regulator LP spring conversion kits for both pressure levels are available for this control..... 6J TWO STAGE GAS VALVE 6 7 8 9 67 NOTE: TYPICAL OPENING CURVE NATURAL GAS, BTU/HR. 7" W.C. INLET /." W.C. OUTLET R-7B

Two Stage Model Electrical Connections () MALE QUICK CONNECT TERMINALS -PIN AMP CONNECTOR () OR () OPTIONAL /" MALE QUICK CONNECT TERMINALS FOR GROUND CONNECTION () OR () OPTIONAL /" MALE QUICK CONNECT TERMINALS FOR GROUND CONNECTION Dimensions AMP MATE-N-LOK CONNECTOR CONNECTS AMP 87.7 INLET PRESSURE POST SET SCREW: /" HE HEAD (.9 DIA. + DFT.) ACCEPTS /6" HOSE CONNECTION REGULATOR COVER SCREWS (REG. ADJ. BENEATH THESE SCREWS).79.6 () Quick Connect Terminals OUTLET PRESSURE POST SET SCREW: /" HE HEAD (.9 DIA. + DFT.) ACCEPTS /6" HOSE CONNECTION CONTROL I.D. LABEL 7,6 OUTLET - /" N.P.T. (DUST PLUG INSTALLED),.7 SWING RADIUS SWITCH (SHIPPED IN "ON" POSITION).78...9.68.88.9.9 6.76 INLET - /" N.P.T. (DUST PLUG INSTALLED).69 R-7B

Models Available 6J TYPE BASIC MODEL NUMBER SERIES OPTIONS FEATURES PACK OPTION Pack Code Description Blank Single Pack B Bulk Pack P Pallet Pack Model Number 6J 6J 6J 6J6 6J9 6J 6J 6J 6J Fast Open Slow Open Convertible Two Stage Notes A B C F A C D A C Number 6 TYPE NUMBER CODING Pipe Size (inlet x outlet) / NPT x / NPT Pressure Tap Towers / NPT x / NPT /8 NPT Press. Taps / NPT x / NPT Bottom Outlet /8 NPT Press. Taps VOLTAGE / FEATURE LETTER CODING Notes: A Standard Opening Orifice B Very Slow Opening Orifice C Slow Opening Orifice D Intermediate Opening Orifice E Stage Slow Opening Orifice F No Switch Alpha Numeric None Y Voltage V /6 HZ V /6 HZ Additional Features Std. Adj. Limited Max. Adj. Reg. ACCESSORIES Regulator Conversion Kits F9-69 Natural Gas to LP Single Stage F9-77 Natural Gas to Unregulated LP Single Stage F9-8 Natural Gas to LP Two Stage F9-66 LP to Natural Gas Single Stage F9- LP to Natural Gas Two Stage F7-7 Flange Mount Kit Single or Two Stage White-Rodgers is a division of Emerson Electric Co. The Emerson logo is a trademark and service mark of Emerson Electric Co. R-7B www.white-rodgers.com www.emersonclimate.com