FOR LIQUIDS LEVEL TRANSMITTERS CAPACITIVE LEVEL TRANSMITTERS

Similar documents
NIVOCONT CONDUCTIVE LEVEL SWITCHES LEVEL SWITCHES

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

CAPACITIVE LEVEL METERS CLM 36

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

3DLevelScanner II TECHNICAL DATA SHEET

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

How To Use A Flowmeter

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

SITRANS F flowmeters SITRANS F M

Flow switches Series AD/VH

Dimensions. LUC-M20 with F12 housing and process connection 2" approx. 86 AF60 G2 2 NPT Ø50. Additional dimensions see section dimensions.

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

Plastic tube flowmeters Series PT/PS

Micro Motion Model D and DL Coriolis Flow and Density Meters

Digital inductive conductivity transmitter

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

Microcor Wireless Transmitter (MWT)

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

IFC 070 Technical Datasheet

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Features. Picture. Specifications

Technical Data Sheet. 3DLevelScanner

How To Use A Ds340 (Dsp)

Variable V Area Flowmeter Rotameter The Original

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Control- and feedback head for integrated mounting on Robolux valves Type 2036

T U R B I N E G A S M E T E R

Inductive sensor NI10-M18-Y1X-H1141

OPTIMASS 6000 Technical Datasheet

Turbine Flow Sensor Series VTR

Instruction Manual. T3111 T3111L T3111P T3111Ex

API Marine. BMS Presentation. Ballast Measurement Systems

Electromagnetic Flow Meter

TEIP11 I/P signal converter for standard signals. Measurement made easy

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Technical Information RIA14

Technical Data. Dimensions

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

For Multi-Parameter Meters see mvx

OPTIMASS 1400 Technical Datasheet

Relative pressure transmitter type 520

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MG Transmitter with Digital Output.

Pressure transmitter For general industrial applications Model A-10

Compact pressure switch Flameproof enclosure Ex d Model PCA

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Heating, air-conditioning, cooling

Typical Aluminum GFM Mass Flow Meter

Replacing Displacers with Guided Wave Radar

Duct Humidity Transmitter

Design of intrinsically safe systems

40.3. Control Relays and Timers

Assisted lift operated 2/2-way solenoid valves Type EV250B

TX2123 RS485 TO ETHERNET ADAPTOR

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

The L&J Engineering Model MCG 1500SFI Servo Gauge

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Threaded Resistance Thermometers Model TR10-D, Miniature Design

3/2-way Solenoid Valve, direct-acting, NC or NO

Explosion proof enclosures

ELECTROMAGNETIC FLOWMETER COMPACT

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

Series DFMT Digital Paddlewheel Flowmeter

Rosemount 333 HART Tri-Loop

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Software and Display instruments

Fluxi 2000/TZ Turbine Gas Meter

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Sanitary Type Electronic Flow Switches

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

How To Use A Corona Mdi 110

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

Electric Rotary Actuator - On/Off or programmable control actuator

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

TEIP11-PS I/P signal converter for standard signals. Measurement made easy

4 Posiflow Proportional Solenoid Valves

3500/93 System Display

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electronic Control Devices The European Product Catalogue 2007

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Rosemount 1199 Submersible Seal

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

SEISMIC VELOCITY TRANSDUCER T1-40

HARDWARE MANUAL. Ixx24-A 1/20. Val Controls A/S Limfjordsvej 3 DK-6715 Esbjerg N Tel vc@valcontrols.com

SITRANS F flowmeters SITRANS F M. Transmitter MAG 5000/ /32 Siemens FI Overview

Transcription:

FOR LIQUIDS LEVEL TRANSMITTERS CAPACITIVE LEVEL TRANSMITTERS

O U R P R O F E S S I O N NIVOCAP CAPACITIVE LEVEL TRANSMITTERS MAIN FEATURES Max. 20 m (65.5 ft) measurement range Vertical mounting Rod or cable probe versions -30 +200 C (-22...+392 F) medium temperature Max. 40 bar g (580 psi g) medium pressure 32-point linearization table Indirect assignment of 0% and 100% 4-20 ma + HART output Ex version IP67 protection APPLICATIONS Level and volume measurement Level measurement of conductive and non-conductive materials Level measurement of liquids For high pressure and high temperature mediums GENERAL DESCRIPTION NIVOCAP 2-wire capacitive level transmitters provide an ideal solution for level measurement of conductive or non-conductive liquids. The probe of the instrument and the (which can be either the metal wall of the tank or installed separately) operate as opposing plates of a capacitor. Between the plates of this capacitor the air is replaced by a medium with greater dielectric constant than the air during filling the tank, therefore the capacitance is changing directly proportional to the level. The incorporated electronic circuitry measures the capacitance difference and converts it to an output signal proportional to level. OPERATION, SETTING UP The plates of the capacitor are the probe and the (wall of the tank). The dielectric constant of the air is e r =1. The basic capacity of the probe mounted in empty tank is C 0, which depends on the relative dielectric constant of the air and the mounting position. During filling the capacitance between probe and reference will increase proportionally with the level and the (e r ) relative dielectric constant of the medium. The condition of an accurate level metering is that the change of capacity has to be proportional to the change in level. To comply with the above the probe and the referential probe have to be parallel, because capacity depends on the distance between the two plates. Best suited for the most accurate level measurement is the so called coaxial arrangement. Setting up the NIVOCAP is easy. Using a simple technique the unit is to be taught the minimal (close to minimal) and maximal (close to maximal) levels. If fully filling and draining is inconvenient or not feasible, the teaching is possible at any odd levels with the help of indirect assignment feature. C 0 = basic capacitance C T = end capacitance C = capacitance change MEASUREMENT ARRANGEMENTS Partily insulated probe Coaxial tube weight Metal tank and non-conductive medium. The rod probe is insulated partly at the process connection. With coaxial tube With reference rod probe Cable probe with weight Metal tank

I S Y O U R L E V E L TECHNICAL DATA Version High temp. type with rod probe Cable probe Measurement range (L n ) 0.2 3 m (7.85-120 inch) 1 20 m (3.3-65.5 ft) Capacitance range 0 pf 5 nf Min. capacitance change Saturation capacitance of the insulated probe Max. (Iout) SPAN: 10 pf or 10% FS Relative dielectric constant e r min. 1.5 ~600 pf/m ~200 pf/m Process connection As per order codes Material of wetted parts Threaded part 1.4571 (316Ti) stainless steel Probe Fully or partially PFA coated 1.4301 (304) stainless steel Fully FEP coated steel cable Housing Medium temperature (see: temperature diagram) Ambient temperature Paint coated aluminium or plastic (PBT) 30 C +130 C (-22 F...+266 F) 30 C +200 C (-22 F...+392 F) 30 C +130 C (-22 F...+266 F) 25 C +70 C (-13 F...+158 F), see: temperature diagram Medium pressure max. 4 MPa (40 bar g / 580 psi g), see: pressure diagram max. 1.6 MPa (16 bar g / 232 psi g) Power supply / consumption Output signals 12 36 V DC / max. 800 mw, overvoltage protection against transients Analogue: 4 20 ma (3.9 20.5 ma) Rmax = U t 11.4 V/0.02A Error indication: 3.8 ma vagy 22 ma Digital communication: 4 20 ma + HART Output data Damping time Linearity error Display: SAP-202, 6-digit LCD, dimensions, bargraph 0, 3, 6 300 sec selectable ±0.3% FS Temperature error ±0.02% / C Electrical connection Electrical connection 2x M20 x1.5 cable glands + internal thread for 2x ½ NPT cable protective pipe, cable outer diameter: Ø7 Ø13 mm (0.3...0.5 inch), wire cross section: max.1.5 mm2 (AWG 15) Class III. Ingress protection IP67 Mass 2.5 kg (5.5 lb) with 0.5 m (20 inch) probe 3 kg (6.6 lb) with 0.5 m (20 inch) probe 2 kg (4.4 lb) with 3 m (10 feet) probe SPECIAL DATA FOR Ex CERTIFIED MODELS Protection type Ex marking Intrinsically safe data Ex approved power supply and limit data Temperature classification ia ATEX x II 1G EEx ia IIB T6 Ci 15 nf; Li 200 µh; Ui 30 V; Ii 140 ma; Pi 1 W Uo < 30 V; Io < 140 ma; Po < 1 W Temperature class: T6; T ambient : 70 C (158 F); T medium : 80 C (176 F) TEMPERATURE AND PRESSURE DATA Temperature diagram Pressure diagram T ambient P medium (bar) T medium T medium

DIMENSIONS High temp. type with rod probe Cable probe Coaxial tube Rod Counterweight PROBE SELECTION Consequences of the capacitive operation principle: Relative dielectric constant of the medium should be taken into consideration. Measurement will be accurate only in case of suitable probe and selection. Medium Insulated probe, Partly insulated probe, Conductive Non-conductive er > 2 2 > er > 1,5 Reference probe Rod Tube Tank wall Conductive tank Non-conductive tank Informative e r values Air 1 Butanol 11 Liquid gases 1.2 1.7 Isopropyl alcohol 18 Fuel oil 1.9 4 Ammonia 21 Standard oils 2 4 Ethyl alcohol 24 Petrol 2.3 Glucose 30 Bitumen 2.6 Glycerol 37 Motor-oil 2.6 Water 80 Acids 4 6 Sulphuric acid (T=20 C) 84

DISPLAY Basic functions can be configured by the programming buttons. With the help of the SAP-202 plug-in display a simplified programming can be accomplished which covers full parameter programming. WIRING Display module connector Loop current measuring connector U- U+ 1 2 4-20 ma current output and power supply (HART) I- I+ 2 3 NIVOCAP TRANSMITTERS IN HART MULTIDROP LOOP The MultiCONT processes and displays measurement data supplied by NIVELCO s HART equipped transmitters connected to a Multidrop loop. Up to 15 transmitters (also mixed models) can be connected and remote programming can be also performed through the MultiCONT. Re-transmission of the data is possible via RS485 communication line to a PC or PLC when needed. NIVOCAP TRANSMITTERS IN SYSTEM WITH A PC Instruments with HART output can be connected to a PC interfaced by a UNICOMM HART-USB modem. A HART multidrop loop can consist of a maximum of 15 transmitters. All measured values can be visualized and /or the NIVOCAP transmitters can be remote programmed by the PC. Applicable software: EView2 configuration software or NIVISION process visualization software.

cbr2s15a0602b ORDER CODES ( n o t a l l c o m b i n a t i o n s a v a i l a b l e) NIVOCAP capacitive level transmitters NIVOCAP C - - (1) Probe length Type Transmitter Transmitter+display High temperature transmitter (2) High temperature transmitter+display (2) Housing (1) The order code of an Ex version should end in Ex (2) Not available in Ex version (3) Special process connections are available on request, e.g.: TRICLAMP, sanitary T B H P Aluminium 2 Plastic 3 Probe Process connection (3) 1 BSP 1 NPT Cable probe Cable probe Output / Ex 4-20 ma 2 4-20 ma + HART 4 4-20 ma / Ex ia 6 4-20 ma +HART / Ex ia 8 R P K L A C E G Rod 0 0 m 0 m 0 1 1 m 0.1 m 1 2 2 m 0.2 m 2 3 3 m 0.3 m 3 Cable 0.9 m 9 0 0 m 0 m 0 1 10 m 1 m 1 2 20 m 2 m 2 3 m 3 9 m 9 Nivelco reserves the right to change technical data without notice! ACCESSORIES NIVOCAP s for capacitive rod probes NIVOCAP C - 1 Probe length Process connection 1 ½ BSP A 1 ½ NPT D 1 BSP F 1 NPT E Flanges Probe type Coaxial (4) Rod, (5) Rod, (5) (4) Only with 1 ½" process connection (5) Only with 1" process connection F R P 0 0 m 0 m 0 1 1 m 0.1 m 1 2 2 m 0.2 m 2 3 3 m 0.3 m 3 0.9 m 9 MFT- - Specifications in metric and US units! Standard / Material DIN/1.0037 (A283) 1 DIN/1.4571 (316Ti) 2 DIN/PP 3 DIN/1.0037 (A283)+PTFE 4 ANSI/1.0037 (A283) 5 ANSI/1.4571 (316Ti) 6 ANSI/PP 7 ANSI/1.0037 (A283)+PTFE 8 Size Pressure Instrument connection DIN ANSI PN16/150 psi 1 1 BSP 2 DN50 2 0 PN25/300 psi 2 1 NPT 5 DN65 2 ½ 1 PN40/600 psi 3 1 ½ BSP 7 DN80 3 2 1 ½ NPT 8 DN100 4 3 Other accessories Order Plug-in display module SAP-202 Counterweight for cable probe CTK-103-0M-400-01 Multichannel process controller and display unit MultiCONT P-200 24V DC power supply module, DIN rail mountable NIPOWER PPK-331 Intrinsically safe isolator power supply module, DIN rail mountable UNICONT PGK-301 Ex HART-USB/RS485 modem for remote programming with PC, DIN rail mountable UNICOMM SAK-305 HART-USB modem for remoteprogramming with PC UNICOMM SAT-304 EView2 configuration software for remote programming with PC FREE download! NIVELCO PROCESS CONTROL CO. H-1043 BUDAPEST, DUGONICS U. 11. TEL.: (36-1) 889-0100 FAX: (36-1) 889-0200 E-mail: sales@nivelco.com http://www.nivelco.com