UFGS (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

CLEAR-DIVISIONS CENTERFOLD

PART 1 GENERAL 1.1 SECTION INCLUDES

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION CHAIN LINK FENCES AND GATES

SECTION PIPE HANGERS AND SUPPORTS

CLEAR-DIVISIONS VARIOFOLD

HMMA 810 HOLLOW METAL DOORS HOLLOW METAL MANUAL -87 NAAMM STANDARD FOURTH EDITION METAL DOORS & FRAMES NAAMM 2 NAAMM 2 METAL DOORS & FRAMES

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

CHALKBOARDS, MARKERBOARDS, TACKBOARDS, DISPLAY CASES, AND BULLETIN BOARD CABINETS

-1- SPECIFICATIONS CONE SETTER PLATFORM ATTACHMENT INDEX

How to secure your property after a disaster

SECTION FREIGHT & PARKING GARAGE ELEVATORS PART I - GENERAL

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

The following symbol denotes a generally compliant condition: The following symbol denotes a generally noncompliant condition:

James M. Pleasants Company

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION WINDOW WASHING SYSTEMS

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

glass & Glazing Products

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

SECTION 6. Glass Storefront Doors:

1.02 SYSTEM DESCRIPTION

UNIFIED FACILITIES GUIDE SPECIFICATIONS

CLEAR-DIVISIONS APERTO

SECTION CABLE TRAYS. A. Continuous, rigid, welded steel or stainless steel wire mesh cable management system.

UFGS (February 2011) UNIFIED FACILITIES GUIDE SPECIFICATIONS

TARIFF CODE and updates standard

Sports and High Mast Lighting Poles Phone: (866) Fax: (817)

EXTeRUS. EXTeRUS - With patented design, able to join technology. and quality of materials with a charming shape. Unique

HARDWARE LOCATIONS FOR HOLLOW METAL DOORS AND FRAMES

Cluster Box Units. (CBU s) 3300 Series CBU Door Sizes. Fully Integrated Parcel Lockers CLUSTER BOX UNITS FRONT LOADING. continued on pages 7-11

CHARISMA SHOWER/TUB DOOR INSTALLATION INSTRUCTIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

39HQ Airovision Air Handling Units

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Code of Standard Practice for Timber Frame Structures

Includes specifications for: Surface Cleaning & Mounting Hardware.

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

security solutions for your home

SECTION SERIES 1500 VINYL PATIO DOORS

DENVER MODEL 30 X 30 SPECIFICATIONS

Architectural Specifications* MODEL HDE

Select Radiators Installation Guide

MONDOATHENS BASKETBALL SET (Reference PK110)

Preformed Metal Roofing and Siding

DOORS HOLLOW METAL MANUAL NAAMM STANDARD NAAMM HMMA METAL DOORS & FRAMES METAL. A Division of

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Lunette 2 Series. Curved Fixed Frame Projection Screen. User s Guide

SPIRAL STAIR KIT INSTALLATION MANUAL

SECTION ALUMINUM HANDRAIL AND RAILING SYSTEMS WITH DECORATIVE METAL PANEL INFILLS

Automatic Door Selection Guide

Residential Garage Door Terminology

PRO PANELS the artist s choice in display designed by artists, for artists. voice: fax:

Retail Reception kiosk

PLASTIC CONTAINERS CONTAINER HOLDING TROLLEYS CONTAINER HOLDING CABINETS PLASTIC DRAWER UNITS DRAWER UNIT HOLDER SHELVES FOOD CONTAINERS

INSTRUCTIONS: LocknCharge Laptop Carts

DIVISION 8, METAL SOUND CONTROL DOOR ASSEMBLIES PART 1 GENERAL 1.1 RELATED DOCUMENTS

DE Frame with C Series Sidelight

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

PUMP JACK SYSTEM AND ACCESSORIES

AIRPORT SECURITY FENCING. A. American Society for Testing and Materials (ASTM):

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

STANDARD SPECIFICATIONS SECTION METAL FABRICATIONS

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

2.02. Specifications. General. Products. Execution. Offset Pivots P-694 Top and Bottom Pivots

City of San Diego, CWP Guidelines

Type 1, 3, & 3R Enclosures

Mechanical arms, belts and sheets

Calvert USA, Inc. Attic Stairs

MGB Chrome Bumper Conversion

Speed-Mat Rectangle Cutter

DELTA3-1. Delta 3 Data Centre Rack Solution

2. Division 05 Structural Steel Framing for steel framework requirements

DCF Optimized Rack System

rousseau MODULAR DRAWER SYSTEMS

MODEL HSR-007 Direct Drive Rolling Steel

contents classic 3 switch 4 mini swing 5 sign wedge 6 chalkboards 7 all purpose A frames 8 H2O swingmaster 9 café banner 10 vision 11

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

March 14, Installation of Bay, Bow and Garden Windows

CHAIN-LINK FENCES BID SPECIFICATIONS DESCRIPTION

WARNING: Important: Keep these instructions for future reference. Gate Instructions (1) Assembly and Installation Instructions

SECTION GUARDA SECURITY WINDOW SCREENS

Chapter 3 Pre-Installation, Foundations and Piers

Fabrication Illustration Part No. Description Door Frame. P092 Mortised Butt Hinge P092D P092F (includes P2092 $ 48 $ 21 frame/door reinforcing)

Reduced depth High Density Cabinet HDC with 19 swing frame 36, 40 and 45 U

Base Cabinet with Self-storing Folding Doors and Floor

SECTION GUARDRAILS

Simplified Steel Stair Design for Commercial and Institutional Buildings

WARNING! DO NOT ATTEMPT TO INSTALL THIS KIT IN A POWERED CONVEYOR.

BUILDINGA 1/10 SCALE FLATBED TRAILER

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

BASIC FIRE DOOR REQUIREMENTS TECHNICAL DATA SHEET NO. 401

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Transcription:

USACE / NAVFAC / AFCESA / NASA UFGS-10 22 13 (August 2010) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-10 22 13 (April 2006) UFGS-10605 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated January 2011 SECTION TABLE OF CONTENTS DIVISION 10 - SPECIALTIES SECTION 10 22 13 WIRE MESH PARTITIONS 08/10 PART 1 GENERAL 1.1 REFERENCES 1.2 SUBMITTALS 1.3 DELIVERY, STORAGE, AND HANDLING 1.4 SUSTAINABLE DESIGN CERTIFICATION 1.5 DESCRIPTION OF WORK PART 2 PRODUCTS 2.1 MATERIALS 2.1.1 Steel Shapes, Plates, and Bars 2.1.2 Cold-Formed Steel 2.1.3 Wire Mesh 2.1.4 Floor Sockets 2.2 NORMAL DUTY PARTITIONS 2.2.1 Wire Mesh 2.2.2 Vertical Frames 2.2.3 Horizontal Frames 2.2.4 Center Reinforcing Bar 2.2.5 Capping Bar 2.2.6 Corner Posts 2.2.7 Line Posts 2.2.8 Hinged Doors 2.2.9 Sheet Metal Base 2.3 HEAVY DUTY PARTITIONS 2.3.1 Wire Mesh 2.3.2 Panel Frames 2.3.3 Center Reinforcing Bar 2.3.4 Capping Bar 2.3.5 Corner Posts 2.3.6 Line Posts 2.3.7 Hinged Doors 2.4 SLIDING DOORS 2.5 DOOR OPENING FRAMES SECTION 10 22 13 Page 1

2.6 LOCKS 2.7 SERVICE WINDOWS 2.8 FABRICATION 2.8.1 Standard Panels 2.8.2 Sheet Metal Base Panels 2.8.3 Doors [and Service Windows] 2.8.4 Finish PART 3 EXECUTION 3.1 INSTALLATION 3.1.1 Wire Mesh Partitions 3.1.2 Doors [and Service Windows] 3.1.3 Bracing 3.1.4 Touch-Up -- End of Section Table of Contents -- SECTION 10 22 13 Page 2

USACE / NAVFAC / AFCESA / NASA UFGS-10 22 13 (August 2010) --------------------------- Preparing Activity: NAVFAC Superseding UFGS-10 22 13 (April 2006) UFGS-10605 (August 2004) UNIFIED FACILITIES GUIDE SPECIFICATIONS References are in agreement with UMRL dated January 2011 SECTION 10 22 13 WIRE MESH PARTITIONS 08/10 NOTE: This guide specification covers the requirements for wire mesh partitions for normal and for extra heavy industrial use. Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information. Remove information and requirements not required in respective project, whether or not brackets are present. Comments, suggestions and recommended changes for this guide specification are welcome and should be submitted as a Criteria Change Request (CCR). NOTE: The following information shall be indicated on the project drawings: 1. Location, extent, height, and configuration of wire mesh partitions. 2. All openings, direction of door swing. 3. If the project includes both normal duty and heavy duty partitions, indicate the extent of each type. PART 1 GENERAL 1.1 REFERENCES NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are referred to in SECTION 10 22 13 Page 3

the text by basic designation only and listed in this paragraph by organization, designation, date, and title. Use the Reference Wizard's Check Reference feature when you add a RID outside of the Section's Reference Article to automatically place the reference in the Reference Article. Also use the Reference Wizard's Check Reference feature to update the issue dates. References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process. The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. AMERICAN IRON AND STEEL INSTITUTE (AISI) AISI SG03-3 (2002; Suppl 2001-2004; R 2008) Cold-Formed Steel Design Manual Set ASTM INTERNATIONAL (ASTM) ASTM A 36/A 36M (2008) Standard Specification for Carbon Structural Steel GREENGUARD ENVIRONMENTAL INSTITUTE (GEI) GEI Greenguard Standards for Low Emitting Products SCIENTIFIC CERTIFICATION SYSTEMS (SCS) SCS Scientific Certification Systems (SCS)Indoor Advantage 1.2 SUBMITTALS NOTE: Review submittal description (SD) definitions in Section 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control. A G following a submittal item indicates that the submittal requires Government approval. Some submittals are already marked with a G. Only delete an existing G if the submittal item is not complex and can be reviewed through the Contractor s Quality Control system. Only add a G if the submittal is sufficiently important or complex in context of the project. SECTION 10 22 13 Page 4

For submittals requiring Government approval on Army projects, a code of up to three characters within the submittal tags may be used following the "G" designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: "AE" for Architect-Engineer; "DO" for District Office (Engineering Division or other organization in the District Office); "AO" for Area Office; "RO" for Resident Office; and "PO" for Project Office. Codes following the "G" typically are not used for Navy, Air Force, and NASA projects. Choose the first bracketed item for Navy, Air Force and NASA projects, or choose the second bracketed item for Army projects. Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are [for Contractor Quality Control approval.][for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government.] The following shall be submitted in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-02 Shop Drawings Wire mesh partitions Show layout, details, materials, dimensions, finishes, and all information necessary for fabrication and installation. SD-03 Product Data Wire mesh partitions Submit for each type of partition, door, and window. Certification 1.3 DELIVERY, STORAGE, AND HANDLING Deliver materials in manufacturer's original, unopened containers or packaging with labels intact and legible. Deliver, store, and handle materials so as to prevent damage. Replace damaged or defective materials with new. [1.4 SUSTAINABLE DESIGN CERTIFICATION Product shall be third party certified by GEI Greenguard Indoor Air Quality Certified, SCS Scientific Certification Systems Indoor Advantage or equal. Certification shall be performed annually and shall be current.] 1.5 DESCRIPTION OF WORK Wire mesh partitions shall be [all wire type] [sheet metal base type], [normal duty for normal industrial use] [heavy duty for extra heavy industrial use], and shall be provided complete with fasteners, capping bars, adjustable floor sockets, bracing, doors, [service windows,] SECTION 10 22 13 Page 5

hardware, and other items necessary for a complete, useable, and rigid installation. PART 2 PRODUCTS 2.1 MATERIALS 2.1.1 Steel Shapes, Plates, and Bars ASTM A 36/A 36M. 2.1.2 Cold-Formed Steel AISI SG03-3. 2.1.3 Wire Mesh Carbon steel wire, woven diamond mesh, intermediate crimped. 2.1.4 Floor Sockets Cast or forged steel or ductile iron, adjustable, approximately 64 mm 2-1/2 inches high. 2.2 NORMAL DUTY PARTITIONS 2.2.1 Wire Mesh 10 gage wire, 38 mm 1-1/2 inch mesh. 2.2.2 Vertical Frames 32 by 16 mm 1-1/4 by 5/8 inch cold-rolled C section channels or 32 by 16 by 3 mm 1-1/4 by 5/8 by 1/8 inch channels. [Provide only C channels where frames are installed toe to toe without posts.] 2.2.3 Horizontal Frames 25 by 16 mm 1 by 5/8 inch channels. 2.2.4 Center Reinforcing Bar One 25 by 13 by 3 mm 1 by 1/2 by 1/8 inch channel with all wires woven through, or two 25 by 10 by 3 mm 1 by 3/8 by 1/8 inch channels bolted together with mesh in between. 2.2.5 Capping Bar 56 by 25 by 3 mm 2-1/4 by one by 1/8 inch channel or 50 by 6 mm 2 by 1/4 inch flat bar. 2.2.6 Corner Posts Structural steel angles, 32 by 32 by 3 mm 1-1/4 by 1-1/4 by 1/8 inch. 2.2.7 Line Posts Unless otherwise indicated, provide partitions more than 3600 mm 12 feet high with flat bar line posts bolted between vertical frame channels. SECTION 10 22 13 Page 6

Sizes of posts shall be as follows: Partition Height Size of Posts 3600 to 4400 mm 44 by 7.9 mm or 50 by 6 mm 4400 to 5900 mm 63 by 7.9 mm 5900 to 7100 mm 75 to 7.9 mm Partition Height Size of Posts 12 feet to 14 feet 8 inches 1-3/4 by 5/16 inch or 2 by 1/4 inch 14 feet 8 inches to 19 feet 8 inches 2-1/2 by 5/16 inch 19 feet 8 inches to 23 feet 8 inches 3 by 5/16 inch 2.2.8 Hinged Doors Frames shall be 32 by 13 by 3 mm 1-1/4 by 1/2 by 1/8 inch channels with 32 by 3 mm 1-1/4 by 1/8 inch flat bar cover on top and bottom rails and on hinge stile and a 35 by 20 by 3 mm 1-3/8 by 3/4 by 1/8 inch angle riveted to the lock stile. Provide 1 1/2 pairs of regular weight, wrought steel, non-removable pin, butt hinges riveted or welded to the door and the door opening frame for each door. 2.2.9 Sheet Metal Base Hot- or cold-rolled sheet steel, not lighter than 16 gage. 2.3 HEAVY DUTY PARTITIONS 2.3.1 Wire Mesh 6 gage wire, 50 mm 2 inch mesh. 2.3.2 Panel Frames 38 by 20 by 3 mm 1-1/2 by 3/4 by 1/8 inch steel channels. 2.3.3 Center Reinforcing Bar One 38 by 20 by 3 mm 1-1/2 by 3/4 by 1/8 inch channel with all wires woven through, or two 32 by 10 by 3 mm 1-1/4 by 3/8 by 1/8 inch channels bolted together with mesh in between. 2.3.4 Capping Bar Structural steel channel, 75 mm by 1.9 kg 3 inch by 4.1 pounds. 2.3.5 Corner Posts Structural steel angles, 45 by 45 by 3 mm 1-3/4 by 1-3/4 by 1/8 inch. 2.3.6 Line Posts Unless otherwise indicated, provide partitions with flat bar line posts SECTION 10 22 13 Page 7

bolted between vertical frame channels. Sizes of posts shall be as follows: Partition Height Size of Posts 2100 to 3600 mm 62 by 7.9 mm 3600 to 4800 mm 75 by 7.9 mm or 62 by 10 mm 4800 to 6000 mm 87 by 7.9 mm Partition Height Size of Posts 7 feet to 12 feet 2-1/2 by 5/16 inch 12 feet to 16 feet 3 by 5/16 inch or 2-1/2 by 3/8 inch 16 feet to 20 feet 3-1/2 by 5/16 inch 2.3.7 Hinged Doors Frames shall be 38 by 20 by 3 mm 1-1/2 by 3/4 by 1/8 inch channels with 38 by 3 mm 1-1/2 by 1/8 inch flat bar cover on top and bottom rails and on hinge stile and a 41 by 22 by 3 mm 1-5/8 by 7/8 by 1/8 inch angle riveted to the lock stile. Provide 1-1/2 pairs of heavyweight, wrought steel, non-removable pin, butt hinges riveted or welded to the door and the door opening frame for each door. 2.4 SLIDING DOORS Frames shall be 38 by 20 by 3 mm 1-1/2 by 3/4 by 1/8 inch channels with 38 by 3 mm 1-1/2 by 1/8 inch flat bar cover all around. Provide two four-wheel, roller bearing hangers and steel box track for each door. 2.5 DOOR OPENING FRAMES Provide frames the same size and shape as the vertical frames for the mesh panels. 2.6 LOCKS Provide each door with a mortise type lock with a six-pin tumbler lock cylinder on the outside and a recessed knob on the inside. 2.7 SERVICE WINDOWS Slide up type, mounted in standard mesh panel reinforced with channel tracks. Opening shall be 600 mm wide by 450 mm high 24 inches wide by 15 inches high unless otherwise indicated. Provide two spring loaded latches, operable only from the inside, to lock window in open and closed positions. [Form shelf of 12 gage sheet steel, 300 mm deep by 625 mm wide 12 inches deep by 25 inches wide, unless otherwise indicated.] 2.8 FABRICATION 2.8.1 Standard Panels Wire shall be woven into diamond mesh, intermediate crimped, and securely clinched to frames. Joints shall be mortised and tenoned. Wire shall be continuous at center reinforcing bars, either woven through a single SECTION 10 22 13 Page 8

channel or bolted between two channels. Panel vertical frames shall have [ 6 mm 1/4 inch bolt holes 300 mm 12 inches o.c. for normal duty partitions] [ 10 mm 3/8 inch bolt holes 450 mm 18 inches o.c. for heavy duty partitions]. 2.8.2 Sheet Metal Base Panels Upper portion shall be as specified for standard panels, except that the wire shall be clinched into the center reinforcing bar. Form sheet steel to fit between the panel frames and securely bolt to the frames. 2.8.3 Doors [and Service Windows] Construction shall be similar to that specified for panels. Wire mesh shall be the same as that used in the adjacent partition panels. 2.8.4 Finish Thoroughly clean ferrous metal, treat with phosphate, and paint with [green] [black] [gray] enamel in the shop. PART 3 EXECUTION 3.1 INSTALLATION 3.1.1 Wire Mesh Partitions Install plumb, level, and true to line, within a tolerance of 3 mm in 3 m 1/8 inch in 10 feet or the height or run of the partition, if less than 3 meters 10 feet. Anchor floor sockets to the floor with expansion bolts. Vertical frames and posts shall be bolted together with [ 6 mm bolts 300 mm o.c. 1/4 inch bolts 12 inches o.c. for normal duty partitions] [ 10 mm bolts 450 mm o.c. 3/8 inch bolts 18 inches o.c. for heavy duty partitions]. Secure top frames to a continuous capping bar with 6 mm 1/4 inch diameter U bolts not more than 650 mm 28 inches o.c. 3.1.2 Doors [and Service Windows] Install in accordance with the manufacturers' recommendations. Adjust as required so that doors [, windows,] and hardware operate freely and properly. 3.1.3 Bracing Brace free standing partitions more than 6 meters 20 feet in length, at intervals not greater than 6 meters 20 feet [with a steel channel brace connected to the capping bar and anchored to the building wall or framing member] [with a structural steel I section or tube post welded to a 225 by 225 mm 9 by 9 inch steel base plate anchored to the floor with 4 expansion bolts] [or as indicated]. 3.1.4 Touch-Up Clean and paint scratches, abrasions, and other damage to shop painted surfaces to match the shop-applied finish. -- End of Section -- SECTION 10 22 13 Page 9