PSEN cs4.1a/b/p/m12. PSEN sensor technology. Operating Manual EN-02

Similar documents
PNOZ s3. Safety relays. Operating Manual EN-10

PNOZ s5. Safety relays. Operating Manual EN-09

Units PSENmag. PSEN 2.2p Unit features. Function description

PNOZsigma - Base units

E-STOP relays, safety gate monitors

Contact expansion modules

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Contact expander modules

E-STOP relays, safety gate monitors

Safe timer relay/contact expansion modules

E-STOP relays, safety gate monitors

E-STOP relays, safety gate monitors

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

E-STOP relays, safety gate monitors

RM4TG20 three-phase network control relay RM4-T - range V

Safety technique. Emergency stop module BO 5988 safemaster

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Cross-beam scanning system to detect slim objects. 100 mm in

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

ABB i-bus KNX SA/S Switch Actuators Product Manual

Digital input modules

PNOZmulti error messages. Configurable Control System PNOZmulti. Error list EN 01

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Pluggable interface relays CR-P Pcb relays

Type: DILM9 10(24VDC) Article No.:

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

ADM1TE 5/30A DIN rail single phase two wire energy meter

Original instructions Tina 3A/Aps Adaptor unit

Inductive sensor NI10-M18-Y1X-H1141

PHOENIX CONTACT Features

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

RY2 miniature industrial relays

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

DS 600. A contact free flux gate based current measurement sensor 600A rms

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Electronic overload relay EF19 and EF45

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Safety automation solutions

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Safety Manual BT50(T) Safety relay / Expansion relay

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Electronic overload relay EF65, EF96 and EF146

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Technical Data. Dimensions

Description. Dimensions. Features. precision works better

Type: DILM32 10(24V50HZ) Article No.:

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Cable Plug acc. to DIN EN , Form A

Safety Relays ESM/ESM-F

Thermal-Magnetic Circuit Breaker M1-..

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Adjustment functions for both span and shift have been incorporated

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

SKR - industry relay

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Preset Counter signo 721

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Control Devices Catalogue. Control Devices. Preferred and Standard Products

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

CONFIGURABLE SAFETY RELAYS

Tina 2A/B Adaptor unit

Givare NC-SRS 280 och 880

Redundancy Module QUINT-DIODE/40

Modular I/O System Analog and Digital Interface Modules

Three-phase monitoring relay CM-PFE

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

38 Series - Relay interface modules A

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Transcription:

PSEN sensor technology Operating Manual-

Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received. Pilz, PIT, PMI, PNOZ, Primo, PSEN, PSS, PVIS, SafetyBUS p, SafetyEYE, SafetyNET p, the spirit of safety are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. SD means Secure Digital

Content Introduction 4 Validity of documentation 4 Retaining the documentation 4 Definition of symbols 4 Safety switch PSEN cs4.1 5 For your safety 5 Unit features 5 Function description 6 Block diagram 6 Operating distances 7 Lateral and vertical offset 7 Wiring 8 Pin assignment, connector and cable 8 Connection to evaluation devices 8 Single connection 9 Series connection 10 Connection to PNOZ X, PNOZpower, PNOZsigma, PNOZelog 11 Connection to PNOZmulti 13 Connection to PSS 13 Teaching in the actuator 13 Installation 14 Parallel assembly 14 Orthogonal assembly 16 Adjustment 17 Operation 17 Error display through flashing codes 18 Dimensions in mm 19 PSEN cs4.1a, PSEN cs4.1b 19 PSEN cs4.1p 19 PSEN cs4.1 M12/8-0.15m 20 Technical details 20 Safety characteristic data 25 Order reference 26 3

Introduction Validity of documentation This documentation is valid for the product PSEN cs4.1a/b/p/m12. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. Retaining the documentation This documentation is intended for instruction and should be retained for future reference. Definition of symbols Information that is particularly important is identified as follows: DANGER! This warning must be heeded! It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken. WARNING! This warning must be heeded! It warns of a hazardous situation that could lead to serious injury and death and indicates preventive measures that can be taken. CAUTION! This refers to a hazard that can lead to a less serious or minor injury plus material damage, and also provides information on preventive measures that can be taken. NOTICE This describes a situation in which the product or devices could be damaged and also provides information on preventive measures that can be taken. It also highlights areas within the text that are of particular importance. INFORMATION This gives advice on applications and provides information on special features. 4

Safety switch PSEN cs4.1 The safety switch meets the requirements in accordance with: } EN 60204-1 and IEC 60204-1 } EN 60947-5-3 with the actuator PSEN cs4.1 } EN 62061: SIL CL 3 } EN ISO 13849-1: PL e and Cat. 4 The safety switch may only be used with the corresponding actuator PSEN cs4.1. The safety outputs must use 2-channel processing. For your safety } Only install and commission the unit if you have read and understood these operating instructions and are familiar with the applicable regulations for health and safety at work and accident prevention. Ensure VDE and local regulations are met, especially those relating to safety. } Any guarantee is rendered invalid if the housing is opened or unauthorised modifications are carried out. } Do not remove the protective cap until you are just about to connect the unit. Unit features } Transponder technology } Coding: fully coded } Dual-channel operation } 2 safety inputs for series connection of multiple safety switches } 2 safety outputs } 1 signal output } LED for: State of the actuator State of the inputs Supply voltage/fault } 1 direction of actuation } Connection types: PSEN cs4.1a: Cable, 5 m PSEN cs4.1b: Cable, 10 m PSEN cs4.1p: 8 pin M8 connector PSEN cs4.1 M12/8-0.15m: Connector 8 pin M12 5

Function description There is a high signal or a low signal at the safety outputs, depending on the position of the actuator and the state of the inputs. The signal output Y32 signals the position of the actuator. State of the inputs and outputs: Actuator in the response range Input S11 Input S21 Safety output 12 Safety output Yes High Low High Low High Yes Low High Low High High Yes High High High High High Yes Low Low Low Low High No x x Low Low Low Signal output Y32 x: High or low signal The outputs cannot be switched back on until there is a low signal at both inputs simultaneously. Safety inputs S11 and S21 are monitored for feasibility. A high signal can be present at the inputs at offset times; the low signal must be present at both inputs simultaneously (partial operation lock). Block diagram A1 A2 S11 S21 Input Power & Receiver Actuator 12 Y32 6

Operating distances On Off Legend: } : Lateral offset } : Vertical offset } : Switch states (y-axis) dependent on operating distances (x-axis) } S ao : Assured operating distance: 8,0 mm } S o : Typical operating distance: 11,0 mm } S r : Typical release distance: 14,0 mm } S ar : Assured release distance: 20,0 mm Lateral and vertical offset 3 4 4 0 5 10-10 -8 4 2-10 -8-6 -4 0 4 6 8 10 mm -6 10 5 10 5 5-4 0 0 0 4 6 8 4 1 6 10 0 5 10 mm Legend: } : Hysteresis } : Typical operating distance S O } : Typical release distance S r } : Offset in mm } : Switching distance in mm } : Response range 7

Wiring Please note: } Information given in the "Technical details" must be followed. } Calculation of the max. cable length l max in the input circuit: I max = R lmax R l / km R lmax = Max. overall cable resistance (see Technical details [ 20] R l / km = cable resistance/km Pin assignment, connector and cable 5 6 4 8 7 3 1 2 Fig.: 8 pin M8/M12 connector PIN Pin designation Function Wire colour 1 S21 Input, channel 2 White 2 A1 +24 VUB Brown 3 12 Output, channel 1 Green 4 Output, channel 2 Yellow 5 Y32 Signal output Grey 6 S11 Input, channel 1 Pink 7 A2 0 V UB Blue 8 - Do not connect Red The wire colour also applies for the cable available from Pilz as an accessory. Connection to evaluation devices Please note: } The power supply must meet the regulations for extra low voltages with safe separation (SELV, PELV). } The inputs and outputs of the safety switch must have a safe separation to voltages over 60 V AC. CAUTION! The safety outputs must use 2-channel processing. 8

Single connection Actuator Receiver Evaluation device 9

Series connection CAUTION! Extension of delay-on de-energisation When several units are connected in series, the delay-on de-energisation time increases in direct proportion to the number of interconnected safety switches. Actuator Receiver Control system Actuator Receiver Actuator Receiver Evaluation device 10

Connection to PNOZ X, PNOZpower, PNOZsigma, PNOZelog INFORMATION Only use safety relays with a 24 VDC supply voltage. Safety relays with universal power supply or in AC unit versions have internal potential isolation and are not suitable as evaluation devices. PNOZ X2.7P PNOZ X2.8P PNOZ X4 PNOZ X8P PNOZ X9P PNOZ A1 A2 0 V 24 V PSENcode 2 A1 7 A2 5 Y32 S21 8 n.c. S 6 S11 S12 1 3 S21 12 S52 4 PNOZ X3P PNOZ X3.10P PNOZ XV3P PNOZ X3.1P PNOZ A1 0 V 24 V PSENcode 2 A1 A2 7 A2 5 Y32 S21 8 n.c. S 6 S11 S12 1 3 S21 12 S32 4 PNOZ s3 PNOZ s4 PNOZ s4.1 PNOZ s5 PNOZ X5 PNOZ A1 A2 0 V 24 V PSENcode 2 A1 7 A2 5 Y32 8 n.c. 6 S11 S12 1 3 S21 12 S 4 11

PNOZ X2.9P PNOZ PSENcode 0 V 24 V A1 A2 S12 S52 2 7 5 8 6 1 3 4 A1 A2 Y32 n.c. S11 S21 12 PNOZ X10.1 PNOZ X10.11P PNOZ 0 V 24 V PSENcode A1 A2 S21 S S12 Y3 2 7 5 8 6 1 3 4 A1 A2 Y32 n.c. S11 S21 12 PNOZ e1.1p PNOZ e1vp PNOZ e6.1p PNOZ e6vp PNOZ A1 0 V 24 V PSENcode 2 A1 A2 7 A2 5 Y32 Y4 8 n.c. S11 6 S11 S12 1 3 S21 12 S 4 PNOZ e5.11p PNOZ e5.13p PNOZ 0 V 24 V PSENcode A1 A2 Y37 S11 S12 S 2 7 5 8 6 1 3 4 A1 A2 Y32 n.c. S11 S21 12 12

Connection to PNOZmulti Safety gate with switch type 3 I0, I1: Inputs OSSD I2: Signal input I0 I1 I2 grün gelb grau Connection to PSS Safety gate standard block SB64 I00, I01: OSSD inputs I02: Signal input grün gelb grau Teaching in the actuator Teaching in the actuator for the first time: The first actuator detected by the safety switch (PSEN cs4.1) is automatically taught in as soon as it is brought into the response range. To teach in a new actuator: } The actuator that is to be taught in must be brought into the safety switch's response range as the only transponder. As soon as the actuator is detected, the "Safety Gate" LED will flash yellow. } After 20 s has elapsed, the "Safety Gate" LED turns to quick yellow flashes. Trigger a system reset in the next 120 s by interrupting the power supply. } When the supply voltage is switched back on, the learning procedure is complete and the number of permitted additional learning procedures is reduced by 1. } A maximum of 8 learning procedures are possible. NOTICE The actuator must not be removed during the learning procedure. This actuator cannot be retaught on the same safety switch. 13

Installation } The safety switch and actuator should be installed opposite each other in parallel. CAUTION! The unit's properties may be affected if installed in an environment containing electrically or magnetically conductive material. Please check the operating distances and the assured release distance. } Safety switches and actuators should only be secured using M4 screws with a flat head (e.g. M4 cheese-head or pan head screws). } The actuator should be protected from unauthorised removal and from contamination. Close the mounting holes using the seals provided. } Torque setting: Max. 0.8 Nm. } The distance between two safety switches must be maintained (see Technical Details [ 20]). Safety switches and actuators } Should not be exposed to heavy shock or vibration and } Should not be used as a limit stop. Parallel assembly Drill holes in the mounting surface (see Dimensions [ 19]) and cut threads in the holes for M4 screws. Use a screw to fix the safety switch in place. 1. Do not fully tighten the 2nd screw on the safety switch. 2. Attach the screws for the actuator, leaving a distance of 3 6 mm between the screw head and plate. Slide the actuator on to the mounting surface. The inscribed area on the actuator (sensing face) should face the safety switch. 14

Slide the actuator on to the screws. Align the safety switch and tighten the screws. Align the actuator and tighten the screws. For the next steps you will need the seals as illustrated. Use the seals to close the screws' mounting holes on the actuator } (4): Without UL approval } (1): For UL approval Use the seals (2) to close the unused mounting holes on the actuator. 15

Use the seals (3) to close the mounting holes on the sensing face of the safety switch. Orthogonal assembly Drill holes in the mounting surface (see Dimensions [ 19]) and cut threads in the holes for M4 screws. Use a screw to fix the safety switch in place. 1. Do not fully tighten the 2nd screw on the safety switch. 2. Attach the screws for the actuator, leaving a distance of 3 6 mm between the screw head and plate. For the next steps you will need the seals as illustrated. Use the seals (2) to close the unused mounting holes on the actuator. Slide the actuator on to the screws. 16

Align the actuator and tighten the screws. Use the seals to close the screws' mounting holes on the actuator } (4): Without UL approval } (1): For UL approval Use the seals (3) to close the mounting holes on the sensing face of the safety switch. Adjustment } The stated operating distances (see Technical details [ 20]) only apply when the safety switch and actuator are installed facing each other in parallel. Operating distances may deviate if other arrangements are used. } Note the maximum permitted lateral and vertical offset (see Operating distances [ 7] and Lateral and vertical offset [ 7]). Operation Check the function of the safety switch before commissioning. Status indicators: } "POWER/Fault" LED lights up green: The unit is ready for operation } "Safety Gate" LED lights up yellow: Actuator is within the response range } "Input" LED lights up yellow: There is a high signal at both inputs. Error display through periodic flashing: } "Input" LED lights up yellow: the signal switches from high to low at one input, while a high signal remains on the other input (partial operation). Remedy: Open both channels of the input circuit. } "POWER/Fault" LED lights up red: Error message Flashing codes for fault diagnostics are output to the "Safety Gate" and "Input" LEDs (see Error display through flashing codes). Remedy: Rectify fault and interrupt power supply. Please note the different switch-on delay after U B is applied and after the recovery time of the sensor and evaluation device. 17

Error display through flashing codes The "Safetygate" and "Input" LEDs send flash signals; an error code can be established from the number and sequence. The "Power/Fault" LED illuminates red. Each error code is indicated by three short flashes of the "Input" or "Safetygate" LED. After a longer pause, the LED will then flash at one second intervals. The number of LED flashes corresponds to a digit in the error code. The error code can consist of up to 4 digits. The digits are separated by a longer period without flashing. The entire sequence is constantly repeated. Number of flashes 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Decimal error code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 Example: Error code 1,4,1: Flash frequency of the Safetygate or Input LED I II III IV V Meaning of flash frequency: Flash frequency Meaning I 3 times, short Code for error message II Once for one second Code for 1st digit III 4 times, for one second each Code for 2nd digit IV Once for one second Code for 3rd digit V 3 times, short Code for error message repeated Table of error codes Error code Number of flashes Description Remedy decimal 1,4,1 3x short 1x long At least one of the two safety outputs Check the wiring of safety outputs 12 and have voltage ap- 4x long 1x long 3x 12 and, rectify the wiring error short plied during system run-up 1,12 3x short 1x long 12x long 3x short 1,13 3x short 1x long 13x long 3x short 14 3x short 14x long 3x short 15 3x short 15x long 3x short During operation, short circuit between safety output 12 and 0 VDC During operation, short circuit between safety output and 0 VDC During operation, short circuit between safety output 12 and 24 VDC During operation, short circuit between safety output and 24 VDC Rectify wiring error at safety output 12 Rectify wiring error at safety output Rectify wiring error at safety output 12 Rectify wiring error at safety output 18

Dimensions in mm PSEN cs4.1a, PSEN cs4.1b 19 14,4 14,4 8 4,5 37 4,5 37 18 R 8 26,4 18 18 PSEN cs4.1p M 8 33 26 140 ± 10 19 14,4 14,4 8 4,5 37 4,5 37 18 R8 26,4 18 18 19

PSEN cs4.1 M12/8-0.15m M 12 31 48.5 160±10 19 14,4 14,4 8 4,5 37 4,5 37 18 R 8 26,4 18 18 Technical details PSEN cs4.1a and PSEN cs4.1b General 541111 541112 Approvals CE, GOST, TÜV, culus Listed CE, GOST, TÜV, culus Listed Sensor's mode of operation Transponder Transponder Electrical data 541111 541112 Supply voltage Voltage 24 V 24 V Type DC DC Voltage tolerance -20 %/+20 % -20 %/+20 % Output of external power supply (DC) 1,0 W 1,0 W Max. switching frequency 3 Hz 3 Hz Switching current per output 100 ma 100 ma Breaking capacity per output 2,4 W 2,4 W 20

Electrical data 541111 541112 Max. cable capacitance at the safety outputs No-load, PNOZ with relay contacts 400 nf 400 nf PNOZmulti, PNOZelog, PSS 400 nf 400 nf Max. inrush current impulse Current pulse, A1 0,58 A 0,58 A Pulse duration, A1 1,0000 ms 1,0000 ms Max. overall cable resistance Rlmax Single-channel at UB DC 1000 Ohm 1000 Ohm Inputs 541111 541112 Number 2 2 Voltage at inputs 24 V DC 24 V DC Input current range 5,0 ma 5,0 ma Potential isolation between input and voltage for the internal module bus No No Semiconductor outputs 541111 541112 OSSD safety outputs 2 2 Signal outputs 1 1 Potential isolation from system voltage No No Short circuit-proof Yes Yes Times 541111 541112 Test pulse duration, safety outputs 450 µs 450 µs Switch-on delay After UB is applied 1,0 s 1,0 s Inputs typ. 13 ms 13 ms Inputs max. 20 ms 20 ms Actuator typ. 45 ms 45 ms Actuator max. 120 ms 120 ms Delay-on de-energisation Inputs typ. 15 ms 15 ms Inputs max. 20 ms 20 ms Actuator typ. 40 ms 40 ms Actuator max. 260 ms 260 ms Supply interruption before de-energisation in the input circuit 10,0 ms 10,0 ms Simultaneity, channel 1 and 2 Environmental data 541111 541112 Ambient temperature In accordance with the standard EN 60068-2-14 EN 60068-2-14 Temperature range -25-70 C -25-70 C Storage temperature In accordance with the standard EN 60068-2-1/-2 EN 60068-2-1/-2 Temperature range -25-70 C -25-70 C 21

Environmental data 541111 541112 Climatic suitability In accordance with the standard EN 60068-2-78 EN 60068-2-78 Humidity 93 % r. h. at 40 C 93 % r. h. at 40 C EMC EN 60947-5-3 EN 60947-5-3 Vibration In accordance with the standard EN 60947-5-2 EN 60947-5-2 Frequency 10,0-55,0 Hz 10,0-55,0 Hz Amplitude 1,00 mm 1,00 mm Shock stress In accordance with the standard EN 60947-5-2 EN 60947-5-2 Acceleration 30g 30g Duration 18 ms 18 ms Airgap creepage Overvoltage category III III Pollution degree 3 3 Rated insulation voltage 75 V 75 V Rated impulse withstand voltage 0,80 kv 0,80 kv Protection type Housing IP6K9K IP6K9K Mechanical data 541111 541112 Change of switching distance with fluctions in temperature +-0,01mm/ C +-0,01mm/ C Actuator 1 PSEN cs4.1 PSEN cs4.1 Typ. hysteresis 2,0 mm 2,0 mm Operating distances Assured operating distance Sao 8,0 mm 8,0 mm Typical operating distance So 11,0 mm 11,0 mm Assured release distance Sar 20,0 mm 20,0 mm Typical release distance Sr 14,0 mm 14,0 mm Min. distance between safety switches 100 mm 100 mm Connection type 5 m cable 10 m cable Cable LiYY 8 x 0.14 mm2 LiYY 8 x 0.14 mm2 Material Top PBT PBT Dimensions Height 37,0 mm 37,0 mm Width 26,0 mm 26,0 mm Depth 18,0 mm 18,0 mm Actuator dimensions Height 37,0 mm 37,0 mm Width 18,0 mm 18,0 mm Depth 18,0 mm 18,0 mm Weight of safety switch 205 g 380 g Weight of actuator 10 g 10 g Weight 215 g 390 g

PSEN cs4.1 M12 and PSEN cs4.1p General 541109 541110 Approvals CE, GOST, TÜV, culus Listed CE, GOST, TÜV, culus Listed Sensor's mode of operation Transponder Transponder Electrical data 541109 541110 Supply voltage Voltage 24 V 24 V Type DC DC Voltage tolerance -20 %/+20 % -20 %/+20 % Output of external power supply (DC) 1,0 W 1,0 W Max. switching frequency 3 Hz 3 Hz Switching current per output 100 ma 100 ma Breaking capacity per output 2,4 W 2,4 W Max. cable capacitance at the safety outputs No-load, PNOZ with relay contacts 400 nf 400 nf PNOZmulti, PNOZelog, PSS 400 nf 400 nf Max. inrush current impulse Current pulse, A1 0,58 A 0,58 A Pulse duration, A1 1,0000 ms 1,0000 ms Max. overall cable resistance Rlmax Single-channel at UB DC 1000 Ohm 1000 Ohm Inputs 541109 541110 Number 2 2 Voltage at inputs 24 V DC 24 V DC Input current range 5,0 ma 5,0 ma Potential isolation between input and voltage for the internal module bus No No Semiconductor outputs 541109 541110 OSSD safety outputs 2 2 Signal outputs 1 1 Potential isolation from system voltage No No Short circuit-proof Yes Yes Times 541109 541110 Test pulse duration, safety outputs 450 µs 450 µs Switch-on delay After UB is applied 1,0 s 1,0 s Inputs typ. 13 ms 13 ms Inputs max. 20 ms 20 ms Actuator typ. 45 ms 45 ms Actuator max. 120 ms 120 ms 23

Times 541109 541110 Delay-on de-energisation Inputs typ. 15 ms 15 ms Inputs max. 20 ms 20 ms Actuator typ. 40 ms 40 ms Actuator max. 260 ms 260 ms Supply interruption before de-energisation in the input circuit 10,0 ms 10,0 ms Simultaneity, channel 1 and 2 Environmental data 541109 541110 Ambient temperature In accordance with the standard EN 60068-2-14 EN 60068-2-14 Temperature range -25-70 C -25-70 C Storage temperature In accordance with the standard EN 60068-2-1/-2 EN 60068-2-1/-2 Temperature range -25-70 C -25-70 C Climatic suitability In accordance with the standard EN 60068-2-78 EN 60068-2-78 Humidity 93 % r. h. at 40 C 93 % r. h. at 40 C EMC EN 60947-5-3 EN 60947-5-3 Vibration In accordance with the standard EN 60947-5-2 EN 60947-5-2 Frequency 10,0-55,0 Hz 10,0-55,0 Hz Amplitude 1,00 mm 1,00 mm Shock stress In accordance with the standard EN 60947-5-2 EN 60947-5-2 Acceleration 30g 30g Duration 18 ms 18 ms Airgap creepage Overvoltage category III III Pollution degree 3 3 Rated insulation voltage 75 V 75 V Rated impulse withstand voltage 0,80 kv 0,80 kv Protection type Housing IP67 IP67 Mechanical data 541109 541110 Change of switching distance with fluctions in temperature +-0,01mm/ C +-0,01mm/ C Actuator 1 PSEN cs4.1 PSEN cs4.1 Typ. hysteresis 2,0 mm 2,0 mm Operating distances Assured operating distance Sao 8,0 mm 8,0 mm Typical operating distance So 11,0 mm 11,0 mm Assured release distance Sar 20,0 mm 20,0 mm Typical release distance Sr 14,0 mm 14,0 mm Min. distance between safety switches 100 mm 100 mm 24

Mechanical data 541109 541110 Connection type M12, 8-pin male connector M8, 8-pin male connector Cable LiYY 8 x 0.14 mm2 LiYY 8 x 0.14 mm2 Material Top PBT PBT Dimensions Height 37,0 mm 37,0 mm Width 26,0 mm 26,0 mm Depth 18,0 mm 18,0 mm Actuator dimensions Height 37,0 mm 37,0 mm Width 18,0 mm 18,0 mm Depth 18,0 mm 18,0 mm Weight of safety switch 40 g 35 g Weight of actuator 10 g 10 g Weight 50 g 45 g The standards current on 2009-01 apply. Safety characteristic data Operating mode EN ISO 13849-1: 2008 PL EN ISO 13849-1: 2008 Category EN IEC 62061 SIL CL EN IEC 62061 PFH D [1/h] IEC 61511 SIL IEC 61511 PFD 2-ch. OSSD PL e Cat. 4 SIL CL 3 2,62E-09 SIL 3 7,68E-05 20 EN ISO 13849-1: 2008 T M [year] All the units used within a safety function must be considered when calculating the safety characteristic data. INFORMATION A safety function's SIL/PL values are not identical to the SIL/PL values of the units that are used and may be different. We recommend that you use the PAScal software tool to calculate the safety function's SIL/PL values. 25

Order reference Product type Features Connection type Order no. PSEN cs4.1 M12/8-0.15m/ PSEN cs4.1 PSEN cs4.1p/psen cs4.1 PSEN cs4.1a/psen cs4.1 PSEN cs4.1b/psen cs4.1 PSEN cs4.1 M12/8-0.15m (switch) Safety gate system, fully coded Safety gate system, fully coded Safety gate system, fully coded Safety gate system, fully coded 8-pin M12 connector 541 109 8-pin M8 connector 541 110 Cable, 5 m 541 111 Cable, 10 m 541 112 Safety switch, fully coded 8-pin M12 connector 541 159 PSEN cs4.1p (switch) Safety switch, fully coded 8-pin M8 connector 541 160 PSEN cs4.1a (switch) Safety switch, fully coded Cable, 5 m 541 161 PSEN cs4.1b (switch) Safety switch, fully coded Cable, 10 m 541 162 PSEN cs4.1 Actuator, coded 541 180 26

Back cover, Sachnummer 2013-08 Printed in Printed Germany in Germany Pilz GmbH & Co. Pilz KG, GmbH 2011 & Co. KG, 2011... In many countries we are represented by our subsidiaries and sales partners. Please refer to our homepage for further details or contact our headquarters. Pilz GmbH & Co. KG Felix-Wankel-Straße 2 73760 Ostfildern, Germany Telephone: +49 711 3409-0 Telefax: +49 711 3409-133 E-Mail: pilz.gmbh@pilz.de Internet: www.pilz.com Technical support +49 711 3409-444 support@pilz.com InduraNET p, Pilz, PIT, PMCprotego, PMI, PNOZ, Primo, PSEN, PSS, PVIS, SafetyBUS p, SafetyEYE, SafetyNET p, the spirit of safety are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. We would point out that product features may vary from the details stated in this document, depending on the status at the time of publication and the scope of the equipment. We accept no responsibility for the validity, accuracy and entirety of the text and graphics presented in this information. Please contact our Technical Support if you have any questions.