PXM20-E. Operator unit. Desigo PX. BACnet auf Ethernet/IP

Similar documents
PXM20-E. Operator unit DESIGO PX

Digital input modules

TX OPEN RS232/485 module

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Automation stations modular model

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

DESIGO PX PXM10 operator unit User's guide Version 2.3. Siemens Building Technologies Building Automation

PCS0100en Persy Control Services B.V. Netherlands

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

IntesisBox KNX LG Air Conditioning

IntesisBox Modbus Server SAMSUNG Air Conditioners

HWg-STE HWg-STE PoE MANUAL

HCR3.2/.. Chipcard reader HOTEL SOLUTION

RRV934. Multi-controller. Synco living

IntesisBox KNX Mitsubishi Heavy Industries AC

Air damper actuators

Drayton Digistat +2RF/+3RF

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

OZW30. Central Unit SYNERGYR

VTO6xxx. IP door stations. User manual

40.3. Control Relays and Timers

KNX Panasonic Air Conditioners

HMI display Installation Guide

Modbus Server SAMSUNG Air Conditioners

Energy Communication Unit (ECU)

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Energy Communication Unit (ECU)

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

VFS24/32HDIP. Public Display IP Monitor User Manual

Duct Humidity Transmitter

AXIS T81B22 DC 30W Midspan

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Automation stations modular series

VAV compact controller KNX / PL-Link

Setup guide. point to point wall plate extenders

Product Information Sheet UH36 Hi Pot Tester

IFS SP-PoE Splitter User Manual

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

FIREDEX Conventional Fire Panels

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

MultiViu Flex 7 Data Sheet

VAV compact controller KNX / PL-Link

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

NC-12 Modbus Application

Quick Connect. quick - simple - efficient.

IntesisBox KNX Modbus TCP master

I STAR COMPUTER CO., LTD

User Manual. EtherUSB

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

Users manual. TCW181B-CM_R1 Page 1

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

OZW V2.0. Web server. Synco TM, Synco TM living

OZS Web server. For LPB/BSB plants

GSM HOME SECURITY SYSTEM

(IR) Bullet LPR/ANPR Network Camera

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Product and functional description

SNMP Web Management. User s Manual For SNMP Web Card/Box

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Heating Controller. Building Technologies HVAC Products

Electronic Control Devices The European Product Catalogue 2007

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

DC1100 & 1400 Energy Controllers. Satchwell DC1100 & DC1400 for energy-efficient temperature control in smaller buildings.

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

Front cassettes for process units

PC Software for VAV compact and modular controllers

10/100/1000 Base-T to Gigabit Fiber Media Converter

Cisco Unified IP Phone Power Injector

How To Use An Ip Phone With A Sim Sim Sims 2 (Iphone) Or Ip Phone (Ip Phone) With A Microsoft Ip Phone 2 (Ipphone) With An Ipro (Ipro) Or Sims 1 (Ip

Index. ROPIX P18 Hardware ROPIX P18 Software ROPIX P18

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

ZMR 80 STEREO MODULAR ZONER USERS MANUAL

Firmware version: 1.10 Issue: 7 AUTODIALER GD30.2. Instruction Manual

LCD MONITOR / 8 CHANNEL DVR COMBO

Digital Keypad Use s Manual

C9 HD Video Conference Terminal

1 Serial RS232 to Ethernet Adapter Installation Guide

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

alpha DSL WTM EG Instructions for use ADSL-Modem alpha DSL WTM EG

Installation and User Guide

Uninterruptible Power Supply

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

UPS Network Interface. Quick InstallationGuide

IntesisBox KNX Modbus RTU master

8-Port PoE Network Switch

TrueAlarm Fire Alarm Systems

GV-Keyboard. User's Manual V2.0

Transcription:

9 234 Desigo PX Operator unit BACnet auf Ethernet/IP PXM20-E Network-compatible operator unit for viewing and operating one or more Desigo PX automation stations. Display with adjustable contrast Energy saving LED backlight (series B and later) Simple key operation with direct access to the required plant information Generic operation and display of plant functions (alarm handling, time schedulers, calendars, setpoint adjustments, display of current values, etc.) Integrated acoustic and/or visual collective alarm Graphic online-trend function Support of integrated access protection in the overall Desigo system Facility to add or delete new users Automatic logout Heating curve graphics System date and time setting Context-sensitive help function Installation in modular automation station PXC..-U or remote 10/100 Mbps RJ45 Ethernet connection with built-in autosensing Supports POE (Power Over Ethernet) operating voltage to IEE 802.3af CM1N9234en_04 2015-01-06 Building Technologies

Application The PXM20-E operator unit ensures the convenient display and operation of Desigo PX automation stations via BACnet network communication. The graphics-based display with clear text and direct access via the keyboard ensure a most user-friendly operation. Functions All values visible in the system can be displayed in accordance with the defined operator profile. Typical displays: Display of current values Setpoint and parameter settings Maintenance and error messages Alarm lists and single alarm messages with acknowledgement option and/or reset Time schedulers (7-day schedules and exception programs) Plant switching Login and password inputs An integrated collective alarm message system with acoustic and visual indication is provided. Operating concept User's guide As the PXM20-E operator unit is designed for end-user operation the operating concept concentrates on the simplest and clearest possible display following intuitive operating principles rather then displaying as many values as possible. Any text is displayed as clear text in the chosen language. To ensure a clear orientation for any operator the two top display lines (header lines) always show which building services system or which function is currently in operation. The basic concept of the operation ensures that it is always possible to select direct, with the click of a button on the keyboard, the plant information shown on the relevant line (direct access keys). Any settings or modifications (for example in graphics) can be followed direct on the display (e.g. graphics display for scheduler). The basic concept also ensures that all information and help functions can be called up any time (info key). The functions of the PXM20-E are described in detail in the User's guide, PXM20/PXM20-E operator unit, document CM110754. Indicators and operator controls 2/8 Siemens Operator unit PXM20-E CM1N9234en_04

1. Display 2. Navigation keys (direct access keys and PageUp/PageDown keys): The direct access keys allow direct access to the relevant line. Possible functions: Select value and start the value adjustment Confirm new value Start function Open item 3. Alarm LED: The alarm LED lights up or flashes if an alarm is present in the system. 4. The PageUp and PageDown keys are provided for page scrolling if a page contains more values than can be shown on the display at the same time. 5. Edit keys: These keys allow the selected values to be modified (<+> and < >) and confirmed (< >). 6. ESC key (Undo and GoUp): When editing a value the editing process can be cancelled by using the Undo key (previous value will be displayed again). Otherwise the GoUp key selects the hierarchically higher object. This key is placed between the two blocks containing the navigation and editing keys because, according to its function, it belongs to both. 7. <?> Info key: This key selects the information mode for the next keyboard click. Generic operation and display Depending on to the application program each menu tree is different. Navigation through the menu tree is based on the "ClickDown" procedure using the navigation keys. Alarms and events If the PXM20-E receives an alarm or an event appears on the display a pop-op window appears with the relevant information. Visual and acoustic alarm When an alarm is present the alarm LED flashes and changes to steady light when all alarms have been acknowledged. The acoustic alarm is provided as an option and can be activated optionally when an alarm is triggered. Alarm Viewer Alarms are written into the Alarm Viewer with a symbol, a description and a time/date stamp in chronological order. An acknowledgement mask to acknowledge alarms can be called up in the Alarm Viewer. After acknowledgement the alarm entry disappears from the Alarm Viewer ; however, it will continue to be saved in the history list. Further details can be viewed in the alarm history (e.g. out of service, overridden, dead band, present value, etc.) The PXM20-E history can contain max. 50 entries; the older ones are deleted. Scheduler The Scheduler allows the user a time-dependent switch on/off and the programming of time-dependent setpoint adjustments. The Scheduler consists of a 7-day schedule and an exception program. 7-day schedule With the help of the navigation and editing keys it is very simple to create, modify, delete or copy a 7-day schedule in this mask. For each day an individual "road map" is programmed. Exception programs If the field EXCEPTION OVERVIEW is clicked in the 7-day schedule (see above) the current monthly overview appears and shows as inverted all the days which are affected by an exception. All other months can be called up as overview by using the top direct access key. Siemens Operator unit PXM20-E CM1N9234en_4 3/8

In the exception program, too, the exceptions are created, modified or deleted by using the navigation and editing keys. It is possible to define exception days (e.g. a bank holiday) as well as exception periods (e.g. holiday periods). Click the EXCEPTIONS field to display a list of all programmed exceptions. Online trend The PXM20-E operator unit provides the user with five channels for trend logging, enabling 5 data points to be logged. There are three separate ways of viewing the trend data: Graphical view: In this view all the values of a trend data point stored in PXM20-E will be displayed graphically Online graphical view: In the online view the values will be displayed in a graphical and dynamic manner, i.e. in real time. List: In place of a graphic view, the values can be displayed in list form Info concept Access protection Auto logout and sleep mode Language versions Press the info key to switch to info mode. In this info mode two different kinds of information can be called up: Pressing the info key a second time displays general information for the currently displayed object (e.g. complete path, clear text of object). Pressing a direct access key in info mode displays information for the object or value on the selected line. Exit the info mode by pressing any key. Login by entering password with string editor Display and operation in accordance with user privileges Definition of user privileges during engineering of Desigo PX configurations Login always referenced to a site Alarms Alarm display depends on user privilege Alarm handling in accordance with user privileges Logout If no operator activities are carried out within a set period the device switches off automatically and the display is turned off. Pressing any key activates the device automatically again and the background lighting of the display is switched on. When the operator unit is delivered the language is set to English. The language setting can be changed internally. 4/8 Siemens Operator unit PXM20-E CM1N9234en_04

Ordering 1 PXM20-E operator unit Compatibility Device Type Data sheet Modular automation stations PXC...-U 9221 Compact automation stations PXC...E-D N9215 Modular automation stations PXC...E-D N9222 Accessories Description Connection cable (CAT5), length 3.0 m (order separately) Adapter RS232 RJ45 to connect a PXA-C1 to a PC (order separately) Adapter on PXM20-E for firmware download (order separately) Mounting frame for mounting on the wall or on the control panel door (order separately) Type PXA-C1 PXA-C2 PXA-C4 PXA-H1 Design The PXM20-E operator unit is contained in a robust plastic housing, ideally suited for its many different mounting methods. All indicators and controls are mounted on the front cover of the unit (see page 2). The connections for the automation stations are incorporated on the back of the unit (see page 7). Mounting instructions The PXM20-E is suitable for control panel front mounting or vertical panels (e.g. remote operating panels or similar units). The unit is also suitable for DIN rail snap-mounting. In addition, the PXM20-E can be mounted direct on any modular automation station. The required Ethernet network connection is an anti-kink cable which can be introduced through an aperture in the modular automation station. Commissioning Wiring test The device only supports I/Os that are not configurable, i.e. dedicated I/Os on compact automation stations and I/Os on PTM modules. No support of UIs and I/Os on TX-I/O modules. Therefore the preferred method for wiring test is the Point Test Tool. Switchless commissioning Commissioning before programming: The wiring test supports the reading of all I/Os of compact automation stations, and modular as long as the modules have an address key. In addition the wiring test supports writing to all outputs. This means you can switch on fans, pumps, lamps etc., or drive valves to a defined position. The outputs keep their state as long as the automation station is powered. Firmware download It is possible to download firmware via FTP. Siemens Operator unit PXM20-E CM1N9234en_4 5/8

Disposal The device is classified as waste electronic equipment in terms of the European Directive 2012/19/EU (WEEE) and should not be disposed of as unsorted municipal waste. The relevant national legal rules are to be adhered to. Regarding disposal, use the systems setup for collecting electronic waste. Observe all local and applicable laws. Technical data General device data Operating voltage for 2-pin connector AC 24 V ± 20 % or DC min. 12 V... max. 40 V Operating voltage when plugged into modular automation station AC 24 V ± 20 %, derived automatically from modular automation station Electrical voltage via Ethernet connection Power Over Ethernet (POE) to IEEE 802.3af Safety extra low voltage SELV Protective extra low voltage PELV HD 384 Frequency 50/60 Hz Power consumption Series B and later Series A AC 24 V max. 7 VA max. 12 VA DC 12 max. 3.5 W max. 5 W Internal fuse Thermal, self-resetting Operating data Main processor Freescale PowerPC Data backup in case of power failure Applications, parameter (FLASH) > 10 years Keyboard Type Keyboard with plastic membrane and pressure point Key area 7 x 7 mm Switching pressure 2.1 N Travel 0.6... 0.7 mm Operating life > 1 million operations Material, front membrane Polycarbonate Material, contacts Conductive silver, snap-on discs gold-plated Display Mechanical LCD display F-STN, Black & White Display area 123 x 68 mm No. of dots 240 x 128 dots Dot size 0.47 x 0.47 mm Dot area 0.50 x 0.50 mm Optical Contrast ratio 20: 1 Viewing angle ± 40 Viewing direction 6 o'clock Background lighting Series B and later Series A Type LED CCFL Cold Cathode Fluorescent Lamp Brightness 150 cd/m 2 60 cd/m 2 Rise time lamp 0 s 5 min = 80% Brightness Life span Lamp 50'000 hrs. = 50 % Brightness 20'000 hrs. = 64 % Brightness 6/8 Siemens Operator unit PXM20-E CM1N9234en_04

Ethernet interface Network 10Base-T/100Base-TX, with built-in auto-sensing Cable Min. Cat 5, shielded if >3m PHY Auto-MDI/MDIX crossover correction Power supply via Ethernet connection Supports POE (Power Over Ethernet) to IEE 802.3af Green LED Ethernet Link OK Orange LED Ethernet Signal TX Protocol BACnet over IP Buzzer Noise level at 10 cm distance Min. 85dBA Frequency 2300 ± 300 Hz Mounting options For control panel mounting, remote operating panels, etc. DIN rail mounting Direct on modular automation stations Connections see page 8 Housing protection standard Protection standard to EN 60529 IP 40 (built-in), else IP 30 Protection class Insulation protection class III Ambient conditions Operation Class 3K5 to IEC 721 Temperature 0... 45 C Humidity < 85 % rh Transport Class 2K3 to IEC 721 Temperature 20... 60 C 1) Standards, directives and approvals Humidity Product standard Automatic electronic controls for household and similar use < 85 % rh EN 60730-1 Electromagnetic compatibility (EMC) (area of use) For residential and industrial environments EU conformity (CE) CM1T9231xx *) UL approbation UL 916, http://ul.com/database Environmental compatibility The product environmental declaration contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal) CA1E9234 *) *) The documents can be downloaded from http://siemens.com/bt/download. Dimensions 117 x 210 x 37 mm (H x W x D) See Dimensions, page 8 Weight Without / with packaging + screws 514 g / 568 g Siemens Operator unit PXM20-E CM1N9234en_4 7/8

Connections 00264 RJ45 socket for Ethernet connection 1 G0 (GND -) 2 G (Plus +) Pin1 I 2 Plug-in connection for modular automation stations PXC -U Dimensions All dimensions in mm 00343 37 Drill and cut-out template 5.6 176.8 11.6 00267 47.4 ø 4.8 64.6 8/8 2005 Siemens Switzerland Ltd. Subject to changes Siemens Operator unit PXM20-E CM1N9234en_04