Operating Instructions

Similar documents
VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

EnduraLAM 150 User Manual

Part I - Installation

BroadBand PowerShield. User Manual

Proximity Switches RS (Reed Switch)

Manual. Solar Fountain Mobile Phone Charger

TIG INVERTER INSTRUCTION MANUAL

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

Operating Instructions Drill rig DRU160

Series 7500 Torque Sensor

LCD5500Z / PKP-LCD v3.x Installation Instructions

DIAMOND Retractable Rodding Robot Model SPRAYROD-R

Cross-beam scanning system to detect slim objects. 100 mm in

2000 Series Ultrasonic Welding

Electric Rotary Actuator - On/Off or programmable control actuator

SYSTEM 4C. C R H Electronics Design

Loewe GK Installation and operating manual

Compensation Unit in X-, Y-, and Z-Direction AGE-S-XYZ

Subminiature Load Cell Model 8417

FUJI DIGITAL SOUND DETECTOR FSB-8D INSTRUCTION MANUAL

Control blocks for two-hand start ZSB

HERZ-Thermal Actuators

USER MANUAL. Kramer Electronics, Ltd. Models:

ADM1TE 5/30A DIN rail single phase two wire energy meter

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

MB-Accumulator Operator's Manual

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

CONTOIL DFM 8EDM. Table of contents. Mounting and operating instructions

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

Ultrasonic Welding Solutions. plasquip.com.au

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

HG600/HG800. Hydro-Power Unit. Installation and Operation Guide

DC400 Dispensing Cutoff System

PTO OWNER S MANUAL ALLISON FAMILY CODE. pag.1

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Floating Switch FTS 20 Füllstandgrenzschalter Level Limit Switch Détecteur de niveau

XLS200 MKII. Subwoofer System OWNERS MANUAL

Digital Single Axis Controller

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

IQ SENSOR NET MIQ/JBR

Adjustment functions for both span and shift have been incorporated

Gemini II. Subwoofer System OWNERS MANUAL

81000 Series Aluminum Gate Valve Installation and Repair Manual

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

USER MANUAL. Kramer Electronics, Ltd. Models:

SURROUND MASTER. User Manual 1.0. English. Copyright 2012 Involve Audio

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

MODEL T10023 ACCESSORY KIT #1 FOR T10010/T10097 WET GRINDER

Deluxe Welding Tool Chest

Remote Head REMO ONE. Code Manual

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

SYSTEM 45. C R H Electronics Design

=============================== WARNING

12 Volt 30 Amp Digital Solar Charge Controller

ABB PSPS Erich Steinmann; Generator control-2013

LEDPAR64 USER MANUAL

V94 BULK TAPE DEGAUSSER

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

MODEL G300 BRAKE BLEEDER

Achat 208 HL / 208 HR passive mid-range speaker. user manual

MTX-D, Oil Temperature/Pressure Gauge

ABB Drives. User s Manual HTL Encoder Interface FEN-31

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor

SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

User Manual. RK-2d / RK-2t. dedicated KVM switch and rackmount screen technology. Designed and manufactured by Austin Hughes

zamak nitrile rubber selfestinguishing technopolymer aluminum B10 24 V DC (± 10%) holding 0,32 W, pick-up 5,5 W (25 ms) IP65 button with tool

We reserve the right to make technical changes.

WHOLESALE DIRECT INC WEST 65TH STREET

Pet hair clipper. Model Diagrams within this manual may not be drawn proportionally.

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Absolute Rotary Encoder E6CP

Water Leak Detection System

ACS-30-EU-EMDR-10-MOD

10 TON HYDRAULIC PRESS

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

Single sub-base valve

Addendum to the Operating Instructions

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

System 8. ü ( System 8

zamak nitrile rubber self-extinguishing technopolymer aluminum

Electric Meat Grinder

M A N U A L

Digital inductive conductivity transmitter

Rotary actuators Rotary wing drives Series RAK. Brochure

Model SRMD Setra Remote Monitoring Display

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Instruction Manual MSC710 MSC710-U MSC710-I

VOYAGER 570G. 744A Sprayer Control

SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

DCS Input/Output Relay Card Series

ELECTRIC CENTRAL HEATING FLOW BOILER

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

StructureScan HD Module. Installation Guide ENGLISH

Doc. No: Issue: 1 Date: Aug BTT-02 card printer manual THERMAL TRANSFER CARD PRINTER BTT-02

EC4.8. BalancedReferencePreamplifier. Owner smanual ENG

Transcription:

Operating Instructions SPECIAL FEED UNIT SV35-100-1/50-1 English

Copyright by RINCO ULTRASONICS AG, Switzerland Version 1.0 11/2002 gb, Art.-No. 34209 2

Note Please read carefully and take note of these operating instructions before unpacking the device! Only persons who are familiar with the operating instructions and the applicable regulations with regard to occupational safety and accident prevention may use, service and maintain this device. 3

Content 1 Safety 6 1.1 Explanation of symbols and signs 6 2 Safety information 7 2.1 General 7 2.2 Correct use 7 2.3 Particularly important 7 2.4 Personnel 7 2.5 Personnel protection 7 2.6 Installation of the equipment 7 2.7 Operation 8 2.8 Warranty 8 3 Transportation 9 3.1 Unpacking 9 3.2 Transport damage 9 3.3 Equipment location 9 4 Product information 10 4.1 Product overview 10 4.1.1 Special feed unit 10 4.1.2 Oscillator unit 11 4.1.3 Converter 11 4.1.4 Booster 11 4.1.5 Options 12 4.2 Technical specifications 13 4.2. 1 Feed unit 13 4.2. 2 Front 14 4.2. 3 Trigger block 15 4.2. 4 Levelling plate 15 4.2. 5 Path measurement 16 4.2. 6 Depth cut-off 16 4.2. 7 Lift stop right/left 16 4.2. 8 Compressed air 17 4.2. 9 Dimensions 17 4.2.10 Weight 17 4.2.11 Available generators 17 5 Electrical diagram 18 5.1 Connection plan for use with generator 18 5.2 Connection plan for use with PLC 19 6 Technical drawings 20 6.1 Dimensional drawing SV35-100-1 20 6.2 Dimensional drawing SV35-50-1 21 4

Important! Should you have any enquiries about your special feed unit, please quote the exact model code and serial number. These are to be found on the rating plate located on the side of the device. This device s design and circuitry are both subject to ongoing development and improvement and represent the current state of the art. RINCO ULTRASONICS AG Romanshorn, Switzerland Foreword Congratulations on purchasing the special feed unit. This manual is aimed at providing both purchaser and user with all necessary information for handling, assembly, operation and care of the special feed unit. In order to ensure that the system can be operated at all times, the information and instructions in this manual must be followed. 5

1 Safety 1.1 Explanation of symbols and signs Symbols are used to indicate dangers and modes of behaviour. The symbols are used in the operating instructions. All warning and information symbols describe situations that, if not observed, could endanger people, objects and the environment. There are two types of warning symbols in the operating instructions: Structure of the warning system Note! Particularly important information or instructions to ensure trouble-free operation. Caution! Refers to potentially dangerous situations. Failure to heed the warning could result in severe injury or damage to components. 6

2 Safety information 2.1 General The special feed unit meets the current state of the art and is safe to operate. Both the individual modules and the device as a whole are subject to ongoing quality inspections. 2.2 Correct use The special feed unit is intended exclusively for the ultrasonic welding and ultrasonic cutting of suitable! plastics. Any other or further use is unauthorised. The manufacturer is not liable for any damage caused by improper use. The risk is borne solely by the user. 2.3 Particularly important Before commissioning this device, read these operating instructions carefully. Insufficient knowledge about use and operation can result in damage to the device. These operating instructions should always be available wherever this device is in use. Changes, modifications and additions to the device that could impair its functionality may not be made without the permission of the supplier. 2.4 Personnel Only reliable personnel with the necessary training or who have been instructed accordingly may operate the special feed unit. Ensure that only authorised personnel work with the special feed unit! In accordance with the electro-technical regulations, only an electrical engineer or persons instructed and supervised by an electrical engineer may work on the electrical equipment of this device. Only trained personnel with knowledge of pneumatics may work on the pneumatic facilities! 2.5 Personnel protection With special equipment, the focus is on the design features of modularity and compactness. As the Special feed unit can be used in an infinite variety of different applications, personnel protection has to be incorporated into the equipment design. 2.6 Installation of the equipment Ensure that the equipment has been unplugged from the mains before performing any connection work! The mains connection must have a connection to ground! Observe any statutory safety requirements that may be applicable at national level! In the event of non-compliance with these instructions, the manufacturer shall not be liable for any damage to persons or property! Only personnel who have been instructed accordingly may install and set up the equipment in production facilities. When working with generators, as well as with converters and boosters, the relevant operating instructions must be observed. In order to obtain good welding results, the horn face and the surface of the parts should be exactly parallel to each other. The tools required for setting this up are included in the special machine design. Use only dry compressed air for operation. If necessary, a water separator should be connected in series. 7

2.7 Operation When operating the special feed unit, on no account must the generator or converter casing be opened. There is a high voltage inside the device danger of injury! Do not do anything that could impair safety! Only operate the special feed unit when all safety devices and facilities are in place and in good working order. Before switching on the special feed unit, ensure that there is no danger of anyone being injured when it starts up. Correct operation and the careful handling of equipment and relevant tools during operation: Maintain the operational readiness Increase the service life Reduce downtimes to a minimum 2.8 Warranty By supplying the system, RINCO ULTRASONICS AG enters a warranty obligation in accordance with the VSM (Swiss Association of Machinery Manufacturers). The user must have a knowledge of the content of these operating instructions The instructions and warnings contained in these operating instructions must be observed Unauthorised modifications or changes to parts of the special feed unit, the oscillating system and to the generator are not permitted. RINCO ULTRASONICS AG will be happy to discuss any problems over the telephone or to send trained personnel to provide the necessary instruction. 8

3 Transportation Only specially trained personnel may perform transport work. The transport information on the packaging must be observed. 3.1 Unpacking The equipment is packed at the factory for transport. The shipping container for the equipment withstands normal loads when transported by road, rail and air. On receipt of the shipment, check that all parts correspond to the packing list and also whether there is any visible damage. If you find any damage, notify the transport company immediately and retain the packaging as proof. 3.2 Transport damage The transport company is responsible for any damage that occurs during transport. A complete report detailing the damage has to be submitted to the transport company; this serves as a basis for the claim for damages. In the event of any damage to or loss of the goods supplied by us, we should be notified immediately. A copy of the above-mentioned report should also be submitted as proof of damage or loss. If the goods are delivered by RINCO ULTRASONICS AG free of all charges or CIF, the damaged goods will, if necessary, be replaced and claims will be submitted to the relevant transport insurance company. 3.3 Equipment location The location of the equipment is important. In order to guarantee a long service life, the equipment should be installed in a clean environment. Care should be taken to ensure that the electronic equipment is stored away from all vibrations. The factory settings are made at 20 C. The ambient temperature during use can be between 10 C and 45 C. 9

4 Product information 4.1 Product overview 4.1.1 Special feed unit 1 System pressure display 2 System pressure controller 3 Speed regulating valve 4 Converter casing 5 Horn 1 2 3 4 5 10

4.1.2 Oscillator unit 6 5 Horn 6 HF connection 7 Converter 8 Booster Example Converter: 5 µ Booster: 1: 2 >10 µm Horn: 1:3 >30 µm Amplitude amplification The amplitude can be amplified by means of various types of booster or horn. The individual elements are mechanically connected by means of a screw thread. The tightening torque for 35 khz systems is 15 20 Nm. We recommend the use of a RINCO-tool key. 7 8 Converter = 5 µm The permissible operating temperature is between 10 C and 50 C. 4.1.3 Converter Piezoelectric converter Type C35-10 No amplification with cooling connection as standard C35-12 No amplification, slit 5 Booster = 1:2 >10 µm 4.1.4 Booster The following booster types are available for RINCO 35 khz welding equipment: Horn = 1:3 > 30 µm Reducing Colour Material Booster Colour Material booster 1:0.5 blue Aluminium 1:1 green Aluminium 1:0.6 violet Aluminium 1:1.5 yellow Aluminium 1:2 white Titanium other ratios available 1:2.5 black Titanium on request 1:3 brown Titanium Connecting thread Converter side: M8 Horn side: M8 Before assembly, the coupling surfaces should be cleaned. Parts with a damaged coupling surface should be replaced. 11

4.1.5 Options 9 Trigger block without potentiometer 10 Trigger block with potentiometer 11 Depth cut-off 12 Lift stop left 13 Lift stop right 14 Levelling plate 15 Path measurement right 16 Path measurement left 17 Cooling set (converter cooling)* * If a cooling set is ordered, an unslit C35-10 converter is also supplied. 9 10 11 14 12 13 16 17 15 12

4.2 Technical specifications 4.2.1 Feed unit Maximum tool stroke: 100 mm or 50 mm Force at 6 bar: 745 N Adjustable depth stop with fine adjustment and scale Precision ball guidance on feed slide Dual action cylinder with magnetic ring Switch for upper cylinder position 13

4.2.2 Front The front, namely the pressure-regulating throttlevalve, was designed so that it can be placed on the pneumatic cylinder and screwed into position. The entire module can, of course, also be installed separately When selecting a valve, check whether the application requires the use of an auxiliary-control valve (operating pressure range of 0 8bar). Such a valve, with 24V DC coil, is mounted as standard. 14

4.2.3 Trigger block The trigger block (with or without potentiometer) can be placed on the front and screwed into position. A circuit-board with pressure sensor is located inside the block; this feeds the signal for the ultrasonic trigger to the generator. 4.2.4 Levelling plate The levelling plate facilitates a high degree of parallelism. 15

4.2.5 Path measurement The path measurement unit is fitted with a magnetic sensor (resolution 0.01 mm) and magnetic tape. The complete module can be attached to the side of the special feed unit (converter support). The path measurement unit can be mounted on both sides of the special feed unit. left right The path measurement unit should only be used in conjunction with the PCS generator control unit. See the PCS operating manual for information on welding in the path mode. 4.2.6 Depth cut-off The depth cut-off is fitted with an inductive sensor. The complete module can be attached to the special feed unit (cylinder support). The depth cutoff can be retrofitted as pre-assembled module. The depth cut-off is only possible with special feed unit SV35-100-1. 4.2.7 Lift stop right/left The lift stop can be attached to the special feed unit (cylinder support) as complete module. The lift stop can be mounted on both sides of the special feed unit. right left 16

4.2.8 Compressed air Ensure that only dry compressed air is connected. Minimum 5.5 bar Maximum 7 bar 4.2.9 Dimensions See diagrams on pages 20 and 21. 4.2.10 Weight SV35-100-1 SV35-50-1 6.0 kg with oscillator system 6.0 kg with oscillator system 4.2.11 Available generators Type maximum max. current output consumption SL35 400/600/900 400/600/900 W 5 A PCS35 400/600/900 400/600/900 W 5 A RL35 250/400/600/ 250/400/600/ 900 900 W 5 A 17

5 Electric diagram 5.1 Connection plan for use with generator 24 V 1 24 V 2 24 V 3 0 V 4 Upper limit stop 5 blue S1 brown Safety switch 6 blue S2 brown Trigger 7 white S3 blue red Valve 8 black Y1 red Depth cut-off 9 black S4 blue red Incremental A Incremental B 10 11 red orange S5 black brown Reserve 12 S1 Sensor upper limit stop S2 Safety switch sensor S3 Trigger S4 Depth cut-off sensor (only with SV35-100-1) S5 Magnetic sensor (path measurement) Y1 Solenoid valve 18

5.2 Connection plan for use with PLC 24 V 1 24 V 2 24 V 3 0 V 4 Upper limit stop 5 blue S1 brown Safety switch 6 blue S2 brown Trigger 7 white S3 blue red Valve 8 red Y1 black Depth cut-off 9 black S4 blue red Incremental A Incremental B 10 11 red orange S5 black brown Reserve 12 S1 Sensor upper limit stop S2 Safety switch sensor S3 Trigger S4 Depth cut-off sensor (only with SV35-100-1) S5 Magnetic sensor (path measurement) Y1 Solenoid valve 19

6 Technical drawings 6.1 Dimensional drawing SV35-100-1 20

6.2 Dimensional drawing SV35-50-1 21

RINCO ULTRASONICS AG Industriestrasse 4 CH-8590 Romanshorn 1 Switzerland Telephone +41 71 466 41 00 Fax +41 71 466 41 01 info@rincoultrasonics.com www.rincoultrasonics.com