MNS -Up. Power distribution and UPS in a single, compact system

Similar documents
ABB PSPS Erich Steinmann; Generator control-2013

Low Voltage Switchgear MNS is with MSpeed

EssPro Energy Storage Grid Substation The power to control energy

Medium Voltage Products. ZN1 12 kv arc-proof air-insulated switchgear for primary distribution

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

Modular architecture for high power UPS systems. A White Paper from the experts in Business-Critical Continuity

The Intelligent AX1 Switchgear for Medium Voltage

New SACE Emax 2 for UL 1066 From Circuit Breaker to Power Manager

Ralf Christian, CEO Low and Medium Voltage. Making Things Right with Totally Integrated Power (TIP)

Server Technology, Inc.

Qualitative Analysis of Power Distribution Configurations for Data Centers

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

4.0 UPS dedicated to ICT for unmatched energy savings

Power protection for data centers

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

DC Power Solutions Overview. DC Power Solutions for EVERY Network Application.

UniGear ZS1. Medium voltage, arc proof, air insulated switchgear for primary distribution

Modular Systems, PPMV, 2014 UniPack-G Glass Fiber Reinforced Polyester Compact Secondary Substation

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Product catalog ABB UPS products and solutions Power protection for critical infrastructures

Galaxy VM. Three-phase power protection. schneider-electric.com

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Phase Modular Finally the benefits of Modular ups are for all

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

High-Efficiency AC Power Distribution for Data Centers

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

The easy way to build switchgear and controlgear assemblies in compliance with the regulations

Data Center Uninterrupted efficiency, guaranteed reliability and continuous modularity. ABB solutions always work.

Franco Vecchiato, SAM LPBS Regional Manager New SACE Emax 2 From Circuit-breaker to Power Manager

Cisco Nexus 7000 Series Power Supply Modules

An Uninterruptible Power Supply Topology to Manage the Arrival of Big Data Kenny Green

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Data centre experts. Advanced power protection for data centres

415V DISTRIBUTION FOR GREEN DATA CENTERS

ABB Inc. April 19, 2011 Slide 1

Liebert NXC from 10 to 200 kva

UPS Topologies & Architectures. Don Lemmon Tubbesing Solutions (214) don@tubbesing.com

Arc Terminator Active Arc-Resistant Switchgear

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

415V DISTRIBUTION FOR GREEN DATA CENTERS

PowerGem Pro Uninterruptible Power Supply

BU Control Technologies, Decathlon TM Product Overview. ABB in the Data Center Overview

ABB in data centers Comprehensive products and systems for your most critical infrastructure

Industrial IT for Substation Automation & Protection

Contractors Guide Central Inverter System Installation

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

MCB Tripping Characteristics. MCB s Knowhow ABB STOTZ KONTAKT ABB STOTZ KONTAKT

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

MAJORSINE Power Inverter

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Up-to-Date with Electrical Equipment

Emirates Aluminium starts up World s first fully integrated power distribution system from ABB

Symmetra PX. Industry-leading efficiency, availability, and performance for small, medium, and large data centers and mission critical environments

ABB in data centers Comprehensive products and systems for your most critical infrastructure

DATA CENTER UNIQUE CHARACTERISTICS AND THE ROLE OF MEDIUM VOLTAGE VACUUM CIRCUIT BREAKERS

High-Voltage GIS yesterday - today - tomorrow

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

Data Center Facility Basics

Medium voltage products UniSec for Smart Grid Air-insulated medium-voltage secondary distribution switchgear

EMI in Electric Vehicles

Electrical safety requirements in DC distribution systems

Standardization and modularity as the foundation of data center UPS infrastructure

The Pros and Cons of Modular Systems

Electric Vehicle Charging Solutions

Evaluating the Opportunity for DC Power in the Data Center

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

User s Manual Before using the inverter, you need to read and save the safety instructions.

The most comfortable air-conditioning systems for yachts and superyachts

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Cisco Redundant Power System 2300

Securing your electrical installations Prisma,

Installation manual. Generator Paralleling Controller GPC multi-line C

RIELLO ELETTRONICA. Master HP

38 Series - Relay interface modules A

WIND Power Technology: IMD Integrated Motor Drive

Increasing Data Center Efficiency by Using Improved High Density Power Distribution

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

SG Series UPS kva three phase 400 Vac

Designed for uptime. Defining data center availability via a tier classification system

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Conceptpower DPA kva. True modular UPS system for critical applications. Modular Three-phase UPS system

Contactless Power Transfer : Inductive charging of EV

AC versus DC Power Distribution in the Data Center

Guideline for Energy Efficient Electrical systems for building. Presentation by TERI

Installation and Operation Guide PD4600 Series Converter Replacement

Gas turbine power plants

S c h n e i d e r E l e c t r i c BUSINESS IMPACT. Jack Hack Enterprise System Engineer 19 November 2015

Il Progetto INTEGRIS. Risultati e nuove prospettive per lo sviluppo delle Smart Grid October 2nd 2013 Brescia

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

Cesar RF Power Supplies: 2, 4, 13.56, 27.12, and MHz; 300 W to 5 kw

Transcription:

MNS -Up Power distribution and UPS in a single, compact system Slide 1

About us ABB is the industry leader in low-voltage power supply Proven expertise in data center technology and uninterruptible power supply (UPS) Factories and service centers in 106 countries Fast deliveries and responsive, professional local support Slide 2

Data center drivers Data centers need compact, configurable, switchgear and UPS that are easy to buy, install and maintain Scale fewer, larger facilities Diversity of supply multiple power sources Intelligence smart components that communicate and self-supervise Failing small failures contained, limiting impact on availability Slide 3

What this means for data center managers Data center managers need to: Address mismatches between IT and power facilities, limiting physical data center space Scale power supply more effectively Find space savings for additional IT Improve up-time and productivity Improve energy efficiency Franz Grüter CEO Green Data Center Slide 4

How ABB responds We at ABB understand: Overcapacity is just as serious a topic for data center operators as uptime Data center power supplies need to grow step by step in ways that save space and energy and that make investments predictable With fast installation and can-do, responsive support, ABB works hard to deliver to every customer the same high level of quality service Andre Schaerer Managing Director ABB Low Voltage Systems Switzerland Slide 5

Conventional power supply solutions Conventional power supply architectures use standalone assemblies for input and output switchgear and UPS. Assemblies physically separated Well known and established architecture Expensive and space-consuming topology Extensive power cabling / bus duct/ bus way Separate incoming / outgoing breaker sections Complex to scale Conventional power distribution system layout, with external bus duct or cable connections MNS-Up combines switchgear and UPS into an integrated, fully scalable assembly MNS-Up: highly integrated layout, with internal bus bar connections Slide 6

Integrated power supply solution: MNS-Up Compact assembly Less installation work Lower operation and maintenance cost Ease of service All-in-one: integrated modular scalable MNS-Up: highly integrated layout, with internal bus bar connections Slide 7

What s inside MNS-Up Proven technologies integrated: Modular ABB Conceptpower DPA500 uninterruptible power supply (UPS) with decentralized parallel architecture Design-verified ABB MNS switchgear with space-saving Emax 2 circuit breakers Slide 8

What it means to you Rapid growth without over-investment More available IT space Planned incremental additions ensure responsible energy consumption and facility growth match with business growth Lower maintenance costs and maintaining uptime Higher levels of quality and safety Responsive, professional local support by ABB Slide 9

Additional information Technical data Input voltage Output voltage Battery voltage 380/400/415 VAC +/- 15%, 35-70 Hz 380/400/415 VAC +/- 1%, 50 or 60 Hz 400-650 VDC Power factor Input: 0.99 Output: 1.0 Efficiency Capacity Paralleling capability Bus bar IEC 61439-1/ -2 IEC TR 61641 IEC 60950-1 IEC 62040-1/ -2/ -3 up to 96% in double conversion mode >99% in eco mode 500 kw (5x100 kw) per frame Up to 6 frames (6 x 500 kw = 3.0 MW) Main AC: 4-pole (100% N) up to 6300 A AC out: 3-pole up to 6300 A Low-voltage switchgear and controlgear assemblies Part 1: General rules Part 2: Power switchgear and controlgear assemblies Guide for testing under conditions of arcing due to internal fault Information Technology Equipment Safety Part 1: General requirements Uninterruptible Power Systems (UPS) Part 1: General and safety requirements for UPS Part 2: Electromagnetic compatibility (EMC) requirements Part 3: Method of specifying the performance and test requirements Slide 10

Slide 11