HYDRUS. 1. Installation guide

Similar documents
HYDRUS ULTRASONIC METER

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

MOUNTING AND OPERATING INSTRUCTIONS

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

The multi-functional integrator Supercal 531

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

SHARKY 775 Ultrasonic Compact Energy Meter. Installation and User Guide

Drayton Digistat +2RF/+3RF

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Multifunction devices

Contents. Document information

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

GREISINGER electronic GmbH

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

HERZ-Thermal Actuators

is then retained absolutely without interruption.

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

Digital input modules

IN-OUT Thermometer with Cable Free Sensor and Clock

TMS TANK MANAGEMENT SYSTEM

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

PC INTERFACE MODULES FOR TOLL-PLAZA CLASSIFICATION SENSORS

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Operating instructions Diffuse reflection sensor. OJ50xx / / 2004

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Polyphase kwh Electricity Meter

Manual & Technical Documentation V1.1

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Operating Manual UMB Analogue/Digital Converter ANACON Order Number: 8160.UANA

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Voltage Regulator SPAU 341 C. Product Guide

Mobile Data Power Model: MDP-25

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

MULTICAL 21 DATA SHEET. Electronic ultrasonic cold and hot water meter

Brunata Optuna W (171)

Electronic Pressure Switch EDS 3000

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

MultiViu Flex 7 Data Sheet

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

OZW30. Central Unit SYNERGYR

SONOMETER TM 1000 Ultrasonic compact heat meter

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Modular I/O System Analog and Digital Interface Modules

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Remote Monitoring and REC 501 Control Unit Product Guide

4-Channel Thermometer / Datalogger

with Electronic Assistant

DMX2PWM 9 Channel Dimmer Setup Manual

Combi switchbox with integrated 3/2 way pilot valve

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

Energy Management Energy Meter Type EM23 DIN

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Documentation for. KL2602 and KL2622. Two-channel Relay Output Terminals for 230 V AC / 30 V DC. Version: 1.4 Date:

MINI MCR-SL-R-UI(-SP)

Duct Humidity Transmitter

ABB i-bus KNX SA/S Switch Actuators Product Manual

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

5235 Single Phase Credit Meter

Instruction Manual. T3111 T3111L T3111P T3111Ex

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

1 Safety instructions. 2 Device components. 3 Function. Leader in Led solutions. Compact presence detector. Operating instructions

Electronic Pressure Switch EDS 300

Adjustment functions for both span and shift have been incorporated

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Cable Plug acc. to DIN EN , Form A

Quick Connect. quick - simple - efficient.

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

How To Use A Flowmeter

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

R60 USB to CAN interface Manual (1.5 EN)

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

EXTERNAL DIMENSIONS AND PARTS

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Operating instructions Switching amplifier for fibre optics. OBF5xx / / 2010

A RF18 Remote control receiver MODULE

Installation guide H A. HSI hardwired system interface

crm+25/d/tc/e Extract from our online catalogue: Current to:

Safety technique. Emergency stop module BO 5988 safemaster

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

DALI RC BASIC SO. Control unit Operating instructions

evohome Wireless Radiator Zoning Kit Installation & User Guide

Certificate of EC type-examination of a measuring instrument Number: UK/0126/0102

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Transcription:

Deutsch Table of content 1. Installation guide... 14 2. Transport and storage... 15 3. Installation / Initial operation... 15 4. Battery power supply (one or two batteries)... 16 5. Pin assignment of cable... 16 6. Due date function... 18 7. Pulse outputs (open collector) and pulse rates... 18 8. Interfaces... 19 9. User guide... 19 10. Displays... 22 11. Environmental note... 23 12. Declaration of conformity for MID meters... 23 1. Installation guide These instructions are intended for trained specialised personnel. For this reason no basic working steps are included. The seal on the meter (see fig. IV, pos. 17) must not be damaged! A damaged seal will result in immediate invalidation of the factory warranty and calibration/conformity. The meter must be installed in compliance with the requirements of EN 14151 and the EC Type Examination Certificate! The standards for drinking water installations (e.g. DIN 1988) must be observed! Medium: Water without additives The IZAR@SET software is used for readout/parametrization and is available online at www.diehl.com/metering. Note on radio function The radio function is switched off on delivery and activated automatically when water is detected in the meter. The radio function remains permanently active after a period of continuous operation (>3 hours) with water. -14-

Deutsch 2. Transport and storage Water meters are precision devices and must be protected against impact and vibration! Store meters in a frost-free place (also during transport). The meter can be damaged by frost. 3. Installation / Initial operation If a risk of frost exists, empty the system and, if necessary, remove the meter. Thoroughly flush out the pipes before installing the meter. If the water is soiled, fit the strainer in the pipe before the meter. The meter is to be installed so that the direction of the arrow on the meter housing corresponds to the direction of flow. Avoid the collection of air bubbles in the meter during the installation process. Make sure the meter is installed sufficiently far away from possible sources of electromagnetic interference (switches, electric motors, fluorescent lamps, etc.). Calming sections before and after the meter are not necessary. The meter must not be under any mechanical stress when installed in the pipe. Depending on the version, the meter is suitable for water temperatures from 0.1 C to 90 C. Slowly fill the pipe with water on completion of the installation. The meter must always be filled full with water. The meter must be protected against pressure shocks in the pipe. The meter may only be installed in frost-free areas. Non-return valve The meter can be supplied with a non-return valve (accessory) on request (nominal diameter DN 15 - DN 40). The non-return valve must be mounted in the meter outlet as shown in fig I for meters with a nominal diameter of DN 15 or fig II for meters with a nominal diameter for DN 20 and DN 40 or larger. For meters with a nominal diameter of DN 25/32, a compensating ring must be used to centre the non-return valve. (fig. III). During the installation, the water meter must be held in this position (see fig. III) with a suitable tool to prevent damage to the plastic housing. -15-

Deutsch 4. Battery power supply (one or two batteries) Standard version with one 3.6 VDC lithium battery with a battery lifetime of up to 12 years depending on configuration and installation location. Meter version with two 3.6 VDC lithium batteries with a battery life time of up to 16 years depending on configuration and installation location. Batteries cannot be retrofitted or replaced! 5. Pin assignment of cable The M-Bus, L-Bus or pulse variant of the meter is supplied with a 1.5-m long 3-wire cable with wire end ferrules. Power supply takes place via the internal battery. An external power supply via a M-Bus Master is not possible. Version/colour Pulse L-Bus/pulse M-Bus (2 wire) white Pulse 2 Pulse 2 M-Bus brown GND (ground) GND (ground) green Pulse 1 L-Bus M-Bus Galvanic isolation Because of possible damage due to electrical corrosion a potential tension between the ground connection of the L-Bus / Pulse output and the meter housing (brass) should be avoided. -16-

Deutsch Wiring diagram VCC = 24 V Protective resistance Pulse 1 green Pulse 2 white pulse Rsps = 5k6 brown ground The pulse outputs are open-collector circuits. The collector branch has a resistance of just 0 ohm, i.e. there is no internal current limiting. If required, this must be provided by an external protective resistance. The internal resistance of the switching device must be 5x of the protective resistance. 6. Due date function The consumption values are stored in the memory on the set due date and kept until the next due date. They can be read off the display or transmitted over the M-Bus or optical interface. The due date can be programmed as required. Ex works default setting = 31.12 of the year of delivery. -17-

Deutsch 7. Pulse outputs (open collector) and pulse rates Input voltage Input current Voltage drop at the active output Current through inactive output Reverse current Pulse duration Pulse break Pulse frequency max. 30 V max. 27 ma max. 2 V / 27 ma max. 5 μa / 30 V max. 27 ma min. 125 ms (max. pulse frequency 20 Hz) min. 125 ms max. 4 Hz Available pulse variants: Pulse 1: Total volume or forward volume Pulse 2: Forward volume or direction or fault The pulse values can be configured as desired in the specified value range. Nominal flow rate Q3 [m³/h] 1.6 / 2.5 / 4.0 6.3 / 10 / 16 25 Unit of display m³ m³ m³ shown pre-decimal position shown post-decimal position Pulse value 5 6 6 3 2 2 decadic 0.1 100 L/ pulse 1 1.000 L/ pulse 10 1.000 L/ pulse Pulse value 1 0.1 L/pulse 10 L/pulse 10 L/pulse Pulse value 2 1 L/pulse Direction Direction -18-

Deutsch 8. Interfaces The meter is equipped with various communication interfaces depending on the variant selected: Optical (standard) Radio 434 / 868 MHz (OMS or Real Data) Radio 868 MHz / L-Bus Radio 434 MHz / L-Bus M-Bus Pulse The Communication Description of the interfaces is available on the Internet at www.diehl.com/metering 9. User guide To show the data read by the meter in the display, various windows have been created as functions that can be called up in succession to display the assigned system information (e.g. flow rate, volume, date, due date, medium temperature). IV 17 QUALITY CERTIFIED Made in Germany 2015 LNE-14586 M15 0102.de 1 2 3 16 m³ m³/h 4 5 15 7 14 13 8 9 10 18 Type 171 A Q3: 4 m³/h, DN 20 868. OMS R 250, p 0,4 MAP 16 class 2 T50, IP 68 3021234 8 DME70 1234 5678 6 11 12-19-

Deutsch 1 Conformity label 10 Protection class 2 Year of declaration of conformity 3 Design examination certificate number 11 Optical sensing device 12 Position aid optical head 4 Water volume 13 Pressure stage 5 Flow 14 Dynamics 6 Serial number 15 Rated flow, internal diameter 7 Radio frequency MHz 16 Pressure drop 8 Metrological class 17 Lead seal 9 Max. Temperature 18 Article number An optical touch button is mounted on the front of the meter(see fig. IV pos. 11). This push button is used to switch to the various displays. To save the battery, the meter switches to sleep mode (display off) if the button is not pressed for approx. 4 minutes; it can be woken up by pressing the button. After wake-up, the current status appears in the display for approx. 2 seconds if an error exists; e.g. error message E -- 7 -- A (air in the pipe). Ex works setting for operating mode of optical touch button (short press): Current total volume Display test (alternates between all on and all off) Error messages (if errors exist, e.g. "E -- 7 -- A") Flow rate (m³/h), display > "Err" if not installed Alternates between total volume on due date and due date Current reverse volume Alternates between software version and software checksum (e.g. "F04-005" > "C 7395") Battery lifetime (display alternates between "batt" and date) The loop settings can be programmed to suit customer-specific requirements using the IZAR@SET software. -20-

Deutsch Additional display information (configurable) Medium temperature in C or F Date and time Primary and secondary address Radio signal ON/OFF Pulse value (at interface Pulse) Forward volume Operating hours Due date reverse volume High resolution volume Error hours Error Display / symbols Forward flow Reverse flow Alarm / fault Due date Reverse volume Calibration value Button Water volume information arrow Flow information arrow Service value Test mode Forward volume -21-

Deutsch 10. Displays Error display (visual indication on the LC display in the event of an error) Fault code C1 E1 E4 E5 Description Basic parameter error in flash or RAM - Meter must be replaced The meter must be replaced. Temperature measurement error (temp. outside range, sensor short-circuit, sensor break) Replace meter if sensor short-circuit or sensor break Hardware error, faulty ultrasonic transducer or short-circuit in ultrasonic transducer The meter must be replaced. Too frequent reading (no communication possible for short time) E7* No meaningful ultrasonic signal, air in the measuring path EH Flow overload Alarms (Permanent visual indication on the LC display) Alarm messages A1 A3 A4 A5 A6 Description Reverse flow no consumption Fault / failure of ultrasonic or temperature measurement Leakage alarm Low temperatures (below 3 C) A7* Air in the measuring path, no volume measurement A9 AH Low battery Overload alarm *) If air is trapped in the measuring path, E7 is output to the display. After a defined time (standard 15 min.) the E7 changes to an A7. The A7 is output to the display and saved in the fault memory. -22-

Deutsch Combinations of error and alarm messages can occur simultaneously, e.g. E17, corresponds to E1 and E7. 11. Environmental note The device must not be disposed together with the domestic waste. Return it to the manufacturer for recycling. 12. Declaration of conformity for MID meters Diehl Metering GmbH hereby declares that these products conform to the essential requirements of the following directives: EMC Directive (2004/108/EC) R&TTE Directive (1999/5/EC) MID Directive (2004/22/EC) LNE-14586 EC Type Examination Certificate Number for model 171 A / B The full declaration of conformity is available at http://www.diehl.com/en/diehl-metering/products-solutions/productdownload/ Please select the partner Diehl Metering GmbH and the product area Water metering. -23-