INSTALLATION AND OPERATING INSTRUCTIONS

Similar documents
Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

SCHWINTEK IN-WALL SLIDEOUT TROUBLESHOOTING AND COMPONENT REPLACEMENT

Model Owner s Manual. Español - P. 19 Français - P. 39

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

ENERGY SMART TROUBLESHOOTING GUIDE TABLE OF CONTENTS:

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

Wireless Indoor/ Outdoor Thermometer

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

AMS-1000 Multi-Channel Air Management System for Boost Control

i ChatterBox! Motorcycle Security

Water Leak Detection System

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

12 Volt 30 Amp Digital Solar Charge Controller

INSTALLATION INSTRUCTIONS BOOST CONTROLLER. Pro Control Input (Optional) Tach. Signal. Speed. Gray. Signal. Green Blue. Orange.

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Data-Logging Rain Gauge PRODUCT MANUAL

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE.

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

Troubleshooting Guide for Dispenser Model #900172

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Utility Distribution Systems

LED Security Spotlight User Manual

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Installation Manual. Features SMART SWITCH OCCUPANCY SENSOR. Maximum Energy savings

WARNING: FAILURE TO FOLLOW THESE RULES MAY RESULT IN SERIOUS PERSONAL INJURY CAUTION: INSTALLATION LOCATION:

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

CMD-8000 rev. A COMMANDER SERIES REMOTE CONTROL ENTRY SYSTEM

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

LUCCI AIRFUSION QUEST II CEILING FAN

Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

Amps Per Bank. Total Output. Battery System. Model Name. 6 amps 12 amps 10 amps 20 amps 30 amps 40 amps 15 amps 30 amps 45 amps

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Autotrol 460i and 460TC Control System

Heat Tracing Sales Mt. Airy, Maryland Installation Instructions

Installation and Operating Instructions (for chargers shown below)

Thermo Top - Troubleshooting Tree

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting


Advantium 2 Plus Alarm

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Single Station Remote Alarm

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

73 Chevy C10 Ammeter to Volt Gauge Conversion Mark and Michael Olson 2013 Rev 1.0

Manual Ranging MultiMeter

4.3-inch Back-Up Camera

Troubleshooting Salt Generators

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

GreenWay Solar LED Path and Trail Lighting System. Installation and Owner s Manual

HYDRA HV OPERATION MANUAL. 2.0 Making Connections on your HYDRA speed control. Rosin core electrical solder

INSTALLATION & SERVICE MANUAL. Display Panel

Installation and maintenance instructions. Danfoss Vent

MODEL 5010 DUAL CHANNEL SMOKE/FIRE DETECTION MODULE

EK908FHL - Thermostat for floor heating

Instruction Manual CPPM-4

Automatic Phone-Out Home Monitoring Systems

INSTALLATION MANUAL 3RP / 5RP 4-BUTTON SERIES VEHICLE SECURITY SYSTEMS

WARRANTY AND DISCLAIMER

ELECTRIC BICYCLE OWNER S MANUAL

Odyssey of the Mind Technology Fair. Simple Electronics

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

Pre-Fab Easy Installation For Models: 006-CT-USK, 008-CT-USK Installation and Operating Instructions for Existing Homes with Standard Piping

Technical Guide 08/15/14

12-Volt Negative Ground Installation Instructions

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

Wireless Home Security Alarm System AM 500

MCR1900 Media Converter 19-Slot Chassis

Installer Guide smart connect

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

User Manual for CH-PFC76810

ELECTRONIC THERMOSTAT AND THERMOMETER With SPEED CONTROL

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

Installation and Operation Guide for PD4000 Series Power Control Center

Wireless 7 Day Programmable Room Thermostat

Field-Tested and Fixed in Five!

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Drayton Digistat +2RF/+3RF

Operator: Save these instructions for future use!

SECUREPAK DIGITAL TORQUE TESTER

Transcription:

INSTALLATION AND OPERATING INSTRUCTIONS SPECIFICATIONS Normal Display Outside temperature (coldest of sensors) Power Required.. 120 volt wall outlet Output Voltage 24 or 120 depending on input voltage Output 1 Operation Cycles normally open solenoid off and on Output 2 Operation On or off on rise or fall of temperature Output 1 Cycle Length.. Adjustable in 30 second increments Output 1 Cycle Start Temperature.. 35 F (operator adjustable) Continuous Weep Temperature.. 14 F (operator adjustable) Sensor Length 25 Ft standard. 50-75-100 ft available Memory Retention. Long life lithium battery Maximum Output Load. 3 amps Fuse (protects output circuit)... 5 amp maximum Warranty.. Two year limited

INTRODUCTION The DX1000 WEEP MIZER is a microprocessor controlled system which will automatically cycle your existing normally open solenoid valve (normally closed optional with modification to electronics), depending on outside temperature. When it starts its cycle it only opens your valve for a few seconds and as the temperature drops it automatically increases the amount of time that the valve stays open until it finally opens the valve 100% of the time. The WEEP MIZER also has a secondary output which can be programmed to turn on or off depending on a rise or fall of temperature. You may install temperature sensors in two different locations and the unit will operate from the colder of the two. The WEEP MIZER comes preprogrammed with what we refer to as the fail safe program. This program was used for development and testing in the Denver area with excellent results and average weep water savings of 65%. The fail safe program operates as follows: Temperature Cycle Length % of cycle water runs 35 1 minute 10% or 6 seconds 25 1 minute 50% or 30 seconds 15 1 minute 90% or 54 seconds 14 100% or full on As you can see we are using a one minute cycle so that for every degree the temperature drops your water will run approximately two seconds longer. PROGRAMMING The DX1000 WEEP MIZER comes programmed from the factory with the fail safe program and adjustments are not necessary in most cases. In some instances where there is a long run to the farthest bay, or there are a number of nozzles to weep as may be the case with an automatic, it may be necessary to increase the percentage of cycle time that the water runs at the initial turn on temperature. Beneath the temperature display are two white squares marked A MODE and B + / - These are the pushbuttons that are used for programming. There are five main menu items in the WEEP MIZER. Push the A button to advance from item to item and push the B button to enter that section. Use B button to make any adjustments in that section. PUSH DISPLAY SHOWS REPRESENTS A?_ Log Data storage section A?_ Prog Programming section A?_ Out1 Manual operation of output 1 A?_ Out2 Manual operation of output 2 A?_ Clr Used to clear data stored in Log section LOG SECTION (?_ Log) PUSH DISPLAY SHOWS REPRESENTS A?_ Log Data storage section B LO -22 Lowest temperature recorded since last cleared A HI -22 Highest temperature recorded since last cleared A ON 0000 Number of hours water has run since last cleared A IF 38 Average turn on temperature of normal weep system A IF 0000 Hours temperature has been below average turn on temperature shown above

PROGRAMMING SECTION (?_ Prog) PUSH DISPLAY SHOWS REPRESENTS A Two times?_ Prog Programming section B At 35 System turn on temperature. Weep cycling starts. (P1) A By 25 Middle set point in program (P2) A to 15 Lowest set point in program (P3) A P1 01:00 Cycle length, in minutes, for P1 A P1 10% % of cycle P1 that water flows A P2 01:00 Cycle length, in minutes, for P2 A P2 50% % of cycle P2 that water flows A P3 01:00 Cycle length, in minutes, for P3 A P3 90% % of cycle P3 that water flows A LL -22 Low limit setting for output 2 A HL 113 High limit setting for output 2 A F - - Normal display showing outside temperature Any of the above settings can be reprogrammed by using the B button while that particular item is being displayed. Press the B button repeatedly to increase the number. Hold the B button in to decrease the number. MANUAL OPERATION OF OUTPUTS (?_ Out1 and?_ Out2) These sections are used for the manual operation of output 1 and output 2. They enable you to manually turn on or off the outputs for service or troubleshooting. For output 1: PUSH A Three times B A For output 2: PUSH A Four times B A DISPLAY SHOWS?_ Out1 IS ON or IS OFF (depending on the state of the output at the time) Use the B button to turn the output off or on as required. F - - (normal operation) DISPLAY SHOWS?_ Out2 IS ON or IS OFF (depending on the state of the output at the time) Use the B button to turn the output on or off as required. F - - (normal operation) CLEARING THE LOG (?_ Log) Push the A button five times. Display will show?_ Log. Push and hold the B button until display shows SURE then DONE. All information stored in the log has now been reset. OUTPUT 2 OPERATION Output 2 is designed to be an on-off switch. This output is programmed using the LL and HL settings in the programming section. If the temperature is between the LL and HL settings, the output will be OFF. If the temperature is 1 below the LL setting or 1 above the HL setting the output will turn ON and remain on until the temperature rises to 1 above the LL setting or falls to 1 below the HL setting. Should you wish to control output 2 based on a temperature other than the outside temperature, connect a sensor in the number 3 sensor position. Output 2 will then operate using the temperature from that sensor. Output 1 will continue to operate on the outside temperature.

INSTALLATION Pick a location on your wall that is near a 120 volt outlet and easily accessible. Mount the sensor outside in a location that is not in direct sunlight or near any light fixtures. We recommend mounting the sensor on an angle bracket at least 3 inches from the wall on the north side of your building. Sensor should NOT be mounted to the equipment room wall due to the heat that leaks through the walls. If you cannot get to the north side of your building or far enough away from any heat sources we recommend using two sensors, one mounted on the east side and one mounted on the west side. The WEEP MIZER will operate off the colder of the two sensors. DO NOT attach sensor wire to any conduit as that can cause erratic temperature readings. The sensors are sealed against normal rain and etc. but should not be submersed in water. The green connector is designed so that it can only be plugged in one way. However, there is always the possibility that it may be plugged in backwards. If you should plug the connector in backwards it will damage the unit beyond repair and void the warranty. BE CAREFUL. When installed, the screw heads should be facing away from you. When installing the wires into the connector be careful not to strip too much insulation from wire, ¼ maximum. Also be sure that all strands of the wire are fully in the proper slot and not shorted to the wire next to it. MINIMUM 18 GAUGE WIRE MUST BE USED FOR ALL POWER WHATEVER VOLTAGE YOU PUT INTO 9 AND 10 WILL DETERMINE OUTPUT VOLTAGE PINS 6 AND 10 ARE CONNECTED INTERNALLY AND SHOULD BE NEUTRAL ON 120 VOLT ALL WIRES MUST BE CONNECTED TO SLOT 1 ALL WIRES MUST BE CONNECTED TO SLOT 5 TROUBLESHOOTING Problem Cause Solution Sensor is picking up heat from Relocate sensor Temperature reads high 1 an external source Sensor is defective Replace sensor Temperature reads low Unit needs recalibrated Return unit for service Sensor is defective Replace sensor Temperature reads -22 or 112 Sensor is defective Replace sensor Unit is defective Return unit for service Weep runs continuous (output light is on) 2 Fuse is blown in unit Replace fuse (5 amp maximum) 3 Solenoid valve is stuck open Take valve apart and clean Component failure in unit Return unit for service Weep runs continuous (output light is off) Unit needs reset Programming is scrambled Unplug unit from wall and plug back in Reprogram unit 1. Sensor itself may be calibrated by turning the small screw located on the back of the sensor in the silicone Turn screw clockwise to lower the temperature, counterclockwise to raise. 1/2 turn per degree. Do not adjust more than 10 degrees. 2. To check for power to your solenoid valve without a meter: press "A" button 3 times. Press "B" button once. Now press "B" button repeatedly and listen for solenoid to click. If you hear it click, weep mizer is working and solenoid is stuck or bad. 3. Fuse holder is located on bottom of unit next to the green wiring connector. Turn counterclockwise with a small screwdriver to remove.

WEEP MIZER WIRING 120 VOLT SOLENOID REMOVE GREEN WIRING CONNECTOR BY PULLING DOWN ON IT CONNECT WIRES AS SHOWN IN DIAGRAM BE SURE ALL CONNECTIONS ARE PROPER AND TIGHT 10 9 8 7 6 5 4 3 2 1 120 VOLT NEUTRAL 120 VOLT HOT OUTPUT 2 120 VAC HOT OUTPUT 2 120 VAC NEUTRAL 1 OUTPUT 1 120 VOLT NORMALLY OPEN SOLENOID 2 (OPTIONAL ) 3 (OPTIONAL ) NOTE: When installing extra sensors, put all black wires to #1, all bare wires to #5, and red wires to appropriate positions. If sensor is installed as sensor 3, output 2 will operate on the temperature from that sensor instead of temperature from sensor 1 or 2.

WEEP MIZER WIRING 24 VOLT SOLENOID REMOVE GREEN WIRING CONNECTOR BY PULLING DOWN ON IT CONNECT WIRES AS SHOWN IN DIAGRAM BE SURE ALL CONNECTIONS ARE PROPER AND TIGHT 10 9 8 7 6 5 4 3 2 1 24 VOLT COMMON 24 VOLT HOT OUTPUT 2 24 VAC HOT OUTPUT 2 24 VAC COMMON 1 OUTPUT 1 24 VOLT NORMALLY OPEN SOLENOID 2 (OPTIONAL) 3 (OPTIONAL) NOTE: When installing extra sensors, put all black wires to #1, all bare wires to #5, and red wires to appropriate positions. If sensor is installed as sensor 3, output 2 will operate on the temperature from that sensor instead of temperature from sensor 1 or 2. 5755 S. Gallup St Littleton, CO 80120 303-794-1387 Fax 303-794-0597