9180 Electrolyte Analyzer Electrolyte Analysis you can count on

Similar documents
YSI 2900 Series Biochemistry Analyzers FERMENTATION CONTROL FOOD & BEVERAGE CLINICAL RESEARCH

Cedex Bio HT Bioprocess Analyzer. Be Confident. Be Assured.

Unleash Your Potential

Discover Your Potential

Ion Selective Electrodes

Discover Your Potential

INNOVATION TO MEET YOUR NEEDS

Symmetry in Diagnostics HPLC ANALYZER. Gold Standard Accuracy by Ion-Exchange HbA1c. TOSOH BIOSCIENCE

ADU 5. Automatic Distillation Unit

for patient monitoring

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

2.24. Pump Controller 704. Data Sheet

When your applications demand more than a standard balance, the OHAUS Voyager Pro is up to the task.

BC Auto Hematology Analyzer

cobas 6500 urine analyzer series Fully automated urine work area on a modular platform

KNC Model 3666 Automatic Pressure Calibration System

Your Personal Pipetting Robot

ph and Acidity in Wine and Fruit Juice

ph Alkalinity of Water

Compact Water Quality Meter B-700 series

TBA-FX8 Automated Clinical Chemistry Analyzer with Flexibility to Respond to Demands of Large-Scale Clinical Laboratories

Measurement by Ion Selective Electrodes

akku-drive HiClass electronic control for titration and dispensing excellent precision, comfort, flexibility

Sterilizers with extra class

OPTI CCA-TS Analyzer. Operator s Manual

Name: OMRON M3 HEM-7200-E Upper Arm Blood Pressure Monitor

Density/Specific Gravity/ Concentration Meter DMA 500

Ion-selective Measurements

Mitos P-Pump. product datasheet

EBI 300 / 310 / 330 USB DATA LOGGERS FOR COLD CHAIN MONITORING

TurbiDirect TurbiCheck TurbiCheck WL

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Car and commercial cial air conditioning service solutions

Relative Humidity Calibration Kit

Biochemistry Validation Form

Truck: A :22 PM ton. Maximize payload, maximize profit. LOADRITE X2650 Excavator Scales. transforming the way the world works

Product Information Fire alarm panel 8000 C

PortaSens ll G AS DETECTOR

OPSIS LiquidLINE KjelROC Distillation Unit

How to Verify Performance Specifications

OT 40L / 90L. Laboratory Steam Sterilizers

EXPERIMENT # 3 ELECTROLYTES AND NON-ELECTROLYTES

AU480 Chemistry Analyzer In-Lab Training Manual

RAINCONTROL LCD Special

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

DataView DVTH Data Logger for Temperature and Humidity

2 WORD A4 E / / C A GA + Kal GA Alle Sprachen

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

ACE. Automated Soil CO 2 Exchange System. Soil flux: an important component of total carbon budget

Titrette. class A precision. The next generation Digital Burette!

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

cobas c 111 analyzer Small box. Big performance

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Portable digital microprocessor thermometers with interchangeable probes

User Guide. Temperature and Humidity Datalogger. Model 42280

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

Product Information Sheet UH28CS-12kV Hi Pot Tester

ASN Dialysis Advisory Group ASN DIALYSIS CURRICULUM

Product Information Sheet UH36 Hi Pot Tester

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM

Datex-Ohmeda Critical Care Monitor

MCP 100 MCP 150. Modular Compact Polarimeters. ::: Superior Optical Instruments

Compact ph Measuring Instruments

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

Thermo Scientific Sorvall T3 and G3 Centrifuge Series. Capacity, reliability and performance for routine applications

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

MagIC Installation Manual. Point of Sales Terminals TD06014B

How To Test For Creatinine

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

TR Series Surface Roughness Tester for workshop and laboratory

ph and Acidity in Tomato Sauce

Laboratory Electrochemistry Products. ph Conductivity Dissolved Oxygen

The photoionization detector (PID) utilizes ultraviolet

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

MD SD MS SS MH SH ML SL MT ST

Melting Point Apparatus

OPERATION MANUAL. Pen type, separate electrode SOIL PH METER Model : PH-220S

Portable Density/Specific Gravity/Concentration Meter DMA 35

Wirbelstrom Prüfsysteme. eddyliner. digital

An important first step in identifying those at risk for Cardiovascular disease The Accutrend Plus system: from the makers of the ACCU-CHEK and

AU680 Every Other Week or Every 3,000 Samples (ISE) Maintenance. AU680 Weekly (Analyzer and ISE) Maintenance

Thermal Values. Melting-, Dropping- and Softening Point Simple, fast and reliable

Direct ISE Method Method to 1000 mg/l Na + Sodium ISE

Galvanic Parts Per Million Dissolved Oxygen Systems

PRODUCT NO.: PT-P1SD PRODUCT NAME: Digital SD Slide Projector

Vacuum drying oven for non-flammable solvents

Connect to a remote PC via Ethernet with a monitor, keyboard, and mouse. This network monitor offers both long distance and wireless transmission.

Hygro-Thermometer + InfraRed Thermometer Model RH101

Chemistry 52. Reacts with active metals to produce hydrogen gas. Have a slippery, soapy feeling. React with carbonates to produce CO 2

Application Sheet for Rivaroxaban (Xarelto ) Standard Range with. BIOPHEN Heparin LRT (#221011/221013) RUO

SWISS MADE. Moisture Analyzers. PREMIUM AND MASTER Series 330 XM

Testomat AW101 Water Hardness Monitor. A unique water hardness monitoring system with superior performance

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

DICKSON PR100/PR300/PR500 DICKSON. Pressure Logger Operation. Contents:

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Lovis 2000 M/ME. Microviscometer. ::: Viscometry at its best

X2 series balances INNOVATIVE FUNCTIONAL SOLUTIONS

Back-UPS Pro 1300/1500 Installation and Operation

Transcription:

9180 Electrolyte Analyzer Electrolyte Analysis you can count on The Power of Combination Hospital Point of Care

The concept The 9180 Electrolyte Analyzer combines the advantages of automated analysis with the testing capabilities of several other types of instruments in a single, stand-alone unit, designed to meet the needs of today s medical professional. Simple operation Electrolyte results can be obtained from just 95 µl of whole blood, serum, plasma, acetate or bicarbonate dialysate, or pre-diluted urine using a simple Yes/No dialog. Several kind of sample container collection tube, syringe, capillary or sample cup, Roche MICROSAMPLER can be presented to the instrument probe for sampling. All reagents, as well as waste, are sealed in the convenient SnapPak container. The Electrolyte Analyzer monitors the amount of remaining reagent and prompts the user to insert a fresh SnapPak container when required. As a safeguard, a built-in sensor ensures that SnapPak has been correctly installed. Full automation The analyzer is fully automatic. A two-point calibration is carried out every four hours and a one-point calibration with each test, ensuring precision and conformity to even the most stringent regulatory requirements. Reagent remaining in the SnapPak container is displayed for user reference with each calibration. To conserve reagents and maximize efficiency, the 9180 Electrolyte Analyzer can automatically enter stand-by mode during idle periods. Flexibility The innovative 9180 Electrolyte Analyzer is one of the instruments on the market to give you a choice of seven different, interchangeable electrolyte configurations to fit your immediate and future testing needs. To change the configuration, all you have to do is substitute the electrode and recalibrate. There is no need to change reagents or replace any tubing. The 9180 Electrolyte Analyzer can be configured in the following ways: Na +,K + Na +,K +,Cl Na +,K +,Ca 2+ Na +,K +,Li + Na +,Li + Na +,Ca 2+,Li + Li + Na +,Cl Na +,Ca 2+ Informative display Patient, QC results and user menus are all shown clearly on the backlit display, while the built-in printer provides hard copy of patient sample, QC and calibration results if required. Universal SnapPak The feature that best demonstrates the 9180 Electrolyte Analyzer user-friendliness is the convenient SnapPak container, which contains all the solutions required for any electrolyte parameter configuration together with a sealed waste container for convenience and safety.

Yes/No Easy operation The complete operation is controlled with the Yes/No buttons. Low maintenance Low maintenance is one of the hallmarks of analyzers, and the 9180 Electrolyte Analyzer is no exception. With his long-life, zero-maintenance electrodes, single-pump design and simple fluidic path, the 9180 Electrolyte Analyzer keeps routine service to a minimum. Reagents and waste are sealed in the SnapPak container, eliminating the need to change individual bottles or handle bio-waste. Interchangeable electrodes The combination of measured parameters can be changed to one of several different configurations simply by installing the necessary electrodes. Precision sensors The long-life, maintenance-free electrodes are at the heart of every Electrolyte Analyzer. They form a totally visible sample chamber and ensures a high precision and reliability. Quality assurance The 9180 Electrolyte Analyzer incorporates a Quality Control program, which stores up to 35 values of each of three control levels and automatically flags out-of-range results. QC statistics, including a running mean value, standard deviation and coefficient of variation, can be printed out on all three QC levels at any time, providing the user with an immediate trend analysis of instrument performance. Quality control solution ISETROL, a precisely formulated control, that needs no refrigeration, is the product of choice to monitor the performance of the 9180 Electrolyte Analyzer.

9180 Electrolyte Analyzer Reliability, flexibility and ease of use All the features you have wanted in an electrolyte analyzer come together in the 9180 Electrolyte Analyzer. For the first time, reliability, flexibility, ease of use and low running costs are combined in a single, competitively priced instrument. You can count on the 9180 Electrolyte Analyzer, with their simple, hands-on operation and low maintenance, to go on delivering reliable results time after time. You can count on the 9180 Electrolyte Analyzer to provide the testing flexibility you need for your changing workload, with their interchangeable electrodes, multiple sampling and stand-by mode. And you can count on the 9180 Electrolyte Analyzer to bring you consistently high quality and performance, with their maintenance-free electrodes, combined with extensive performance monitoring.

9180 Electrolyte Analyzer Specifications Electrodes Sodium Sensor Na + ion selective, flow-through, glass capillary electrode Potassium Sensor K + ion selective, flow-through, liquid membrane electrode Chloride Sensor CI ion selective, flow-through, liquid membrane electrode Ionized Calcium Sensor Ca 2+ ion selective, flow-through, liquid membrane electrode Lithium Sensor Li + ion selective, flow-through, liquid membrane electrode Reference System open liquid junction, flow-through electrode Measuring Range (in mmol/l) Whole Blood, Serum, Plasma, QC-Material Na + resolution 0.1 mmol/l range 40 205 mmol/l K + resolution 0.01 mmol/l range 1.5 15 mmol/l CI resolution 0.1 mmol/l range 50 200 mmol/l Ca 2+ resolution 0.001 mmol/l range 0.2 5.0 mmol/l Li + resolution 0.001 mmol/l range 0.1 6.0 mmol/l Dialysate Na + resolution 0.1 mmol/l range 40 205 mmol/l K + resolution 0.01 mmol/l range 0.8 15.0 mmol/l CI resolution 0.1 mmol/l range 50 200 mmol/l Ca 2+ resolution 0.001 mmol/l range 0.2 5.0 mmol/l Urine Na + resolution 1.0 mmol/l range 1 300 mmol/l K + resolution 0.1 mmol/l range 4.5 120 mmol/l CI resolution 1.0 mmol/l range 1 300 mmol/l Calcium is not measured on urine. Lithium is not measured on urine or dialysate fluid. Operating Parameters Sample Size Sample Type Sample Application Analysis Time Sample Rate Calibration Data Management Correlation Factors Normal Values Standby Mode Diagnostic Programs Electronics Display Printout Languages Computer Interface Data Link Temperature Relative Humidity Power Requirements Dimensions Weight Approvals Declaration of Conformity 95 µl typical whole blood, serum, plasma, urine dialysate, aqueous stds, QC syringe, sample cup, collection tube, capillary Roche MICROSAMPLER 50 seconds 60 samples/hour without printout; 45 samples/hour with printout fully automatic, 1-point with every sample; 2-point every 4 hours quality control storage: 3 levels, 34 days; calculation of mean, SD and CV user programmable for sample types: blood, urine, dialysate types flagging of abnormal results; user programmable ranges user or automatically controlled user-controlled diagnostics with easy to understand messages microprocessor controlled; memory for last 20 error messages dot matrix, 2 lines, 16 characters wide built-in, thermal roll priner; 16 characters wide on-board; English, German, French, Spanish, Japanese, Italian, Polish RS-232C (standard serial port) Interface to COMPACT 2 and 3 Blood Gas Analyzer room temperature, 15 C 32 C (60 F 90 F) < 85%, non-condensing 110 240 V, 50/60 Hz (self-adjusting) 1.4 Amp Max H W D: 33.5 31.5 29.5 cm (13.2 12.4 12.0 in) 6 Kgs (13 lbs) approx. CSA CE (EN45014) SNAPPAK, ISETROL and Roche MICROSAMPLER are trademarks of a member of the Roche Group. www.roche-diagnostics.com/npt Roche Diagnostics GmbH Roche Near Patient Testing D-68298 Mannheim Germany