Communication Networks DLTC - Power Line Carrier Line Traps

Similar documents
Transformer Bushings for GIS

Transmission Silicone Insulators Line Post 69 kv to 161 kv

Capacitor Voltage Transformer. Answers for energy.

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

Power transformers. Special transformers Railway

ALTERNATIVE METHODS FOR INTERNAL ARC TESTS ON 12 KV AND 24 KV METAL-ENCLOSED SWITCHGEARS WITH COMPACT RMU

MEASUREMENT SET-UP FOR TRAPS

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Transformers. Special transformers Reactors products

SF 6 Gas Insulated Switchgear Type SDF for 170 kv

Lightning Arresters P KVA P KVA. Description & Installation

Design of Bidirectional Coupling Circuit for Broadband Power-Line Communications

Line Reactors and AC Drives

1ZSC AAC en, Rev. 7. Resin impregnated paper bushing, oil to air, type GSB Technical guide

ELECTRICAL INSULATION TESTING OF HV EQUIPMENT UP TO 33kV

Grounding Demystified

APPLICATION NOTE How to Deal with Electrical Noise and Interference in the Measuring Chain using a NEXUS

ELECTRICAL ENGINEERING DESIGN CRITERIA APPENDIX F

EMTP STUDIES PERFORMED TO INSERT LONG AC CABLES IN THE FRENCH GRID

New Distribution Class Arrester Ground Lead Disconnector Design Enhances Detonation Reliability and Improves Arrester Performance

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

Substation Grounding Study Specification

INTERNATIONAL STANDARD

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements

POWER LINE CARRIER CHANNEL & APPLICATION CONSIDERATIONS FOR TRANSMISSION LINE RELAYING

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

World Leader in HV Testing Technology

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

3. Cooling System Closed-loop Pure Water-cooling. Rated Voltage: 6 ~ 66kV. Rated Current: 4000A (phase current).

OMNIYIG. .5 TO 2 GHz, 1 TO 4 GHz, 6 to 18 GHz Thin Film YIG-TUNED OSCILLATORS OUTLINE DIMESIONS MOUNTING SURFACE GND +15V + TUNE - HTR HTR

High Voltage Power Supplies for Analytical Instrumentation

Lightning current simulation in the laboratory - parameters, procedures and test equipment -

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

1ZSE en, Rev. 8. Transformer bushings, type GOE and GOE(2) Technical guide

understanding medium frequency induction melting furnace and its components

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

Assessment of the Technical Issues relating to Significant Amounts of EHV Underground Cable in the All-island Electricity Transmission System

Product brochure Multi Functional Switchgear PASS M kv Flexible and compact switchgear solutions for windfarms

Modular Systems wind portfolio overview Power Collection and Grid Connection products

Power transformers. Generator step-up and system intertie power transformers Securing high-quality AC transmission

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

Unified requirements for systems with voltages above 1 kv up to 15 kv

LUXEON LEDs. Circuit Design and Layout Practices to Minimize Electrical Stress. Introduction. Scope LED PORTFOLIO

UFES Active protection for switchgear

IEC ESD Immunity and Transient Current Capability for the SP72X Series Protection Arrays

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

Common Mode Filter Inductor Analysis

SPECIFICATIONS FOR 220KV CAPACITOR VOLTAGE TRANSFORMER. The equipment is required for 220KV system. The system data is given as under:

Technical Article. EMC filters for medical devices

RC NETWORKS SALES GUIDE

Instrument Transformers Application Guide

45. The peak value of an alternating current in a 1500-W device is 5.4 A. What is the rms voltage across?

Bourns Resistive Products

Charged cable event. 1 Goal of the ongoing investigation. 2 Energy sources for the CDE. Content

Iron Powder Cores for Switchmode Power Supply Inductors. by: Jim Cox

Metal-Oxide Varistors (MOVs) Surface Mount Multilayer Varistors (MLVs) > MLN Series. MLN SurgeArray TM Suppressor. Description

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

Joslyn Clark Controls, Inc.

MODEL 2202IQ (1991-MSRP $549.00)

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Power over Ethernet plus Isolation requirements. David Law 3Com

Nano Stepping Notch Filter Jim Hagerman

EMI in Electric Vehicles

Secondary Unit Substations

Single Transistor FM Transmitter Design

Chapter 4. LLC Resonant Converter

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Application Note, Rev.1.0, September 2008 TLE8366. Application Information. Automotive Power

Powerformer chosen for Swedish combined heat and power plant

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

LR Phono Preamps. Pete Millett ETF.13.

INTRODUCTION TO SYSTEM PROTECTION. Hands-On Relay School 2012

PROPER SELECTION OF CONTROL CIRCUIT TRANSFORMERS WHITE PAPER BULLETIN 1497, 1497A, AND 1497B

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Guide to the electrical parameter classifications of IEC and IEC safety standards

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Tag Tuning/RFID. Application Note. Tag Tuning. Introduction. Antenna Equivalent Circuit

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

e 2 ALPHA Medium Voltage Switchgear Data Sheet K EN

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Power Capacitor Units for improved power quality

Improved PFC Boost Choke using a Quasi-Planar Winding Configuration Dave Shonts Schott Corporation 1000 Parkers Lake Road Wayzata, MN 55391

Teleprotection Schemes and Equipment. James W. Ebrecht Young Power Equipment Scottsdale, AZ

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

Mylar polyester film. Electrical Properties. Product Information. Dielectric Strength. Electrode Size. Film Thickness

Adaption of Cable Accessories for Onshore and Offshore Substation

MINISTERIE VAN ECONOMISCHE ZAKEN GENERAL COST COMPARISON BETWEEN UNDERGROUND CABLES AND O.H. LINE SYSTEMS FOR H.V. TRANSMISSION

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

MRF175GU MRF175GV The RF MOSFET Line 200/150W, 500MHz, 28V

SECTION 13. Multipliers. Outline of Multiplier Design Process:

Power supply output voltages are dropping with each

38 Series - Relay interface modules A

Power Voltage Transformers for Air Insulated Substations. THE PROVEN POWER.

Transcription:

Communication Networks DLTC - Power Line Carrier Line Traps

ABB Line Traps Type DLTC A reliable component for PLC communication Transmitting information along high-voltage lines (PLC) has been one of the main and certainly the most economic means of communication in electric power systems for more than 5 years. The purpose of PLC line traps: Provision of defined high voltage line impedances regardless of the configuration of the primary system switchgear. Prevention of signal losses due to propagation into other lines. Attenuation of RF signals from other parts of the power system, thus permitting multiple use of the same frequency bands. PLC line traps are connected in series with the high-tension lines and must therefore be rated for the maximum continuous load current and be able to withstand the maximum fault current at the place of installation. DLTC line traps fulfill all the RF requirements as well as all the power system requirements of the latest IEC recommendations. Principal advantages of PLC line traps type DLTC Low volume and small diameter due to multilayer techniques. Hence less wind resistance and simpler maintenance of spacing between conductors. Open construction and therefore better cooling. No danger of local hot-spots or cracking of insulating material. Excellent RF characteristics with high Q and low stray capacitance. Higher resonant frequencies than those used for PLC transmission. All versions available for either pedestal mounting or suspended installation. Wide choice of pedestals suitable for mounting on insulator posts, coupling capacitors and instrument transformers. Provision for nearly every type of conductor terminal. Solid construction permits high mechanical loads on terminals. High voltage withstand of tuning devices ensures high reliability. Tuning devices are tuned for either broadband blocking or damped single frequency blocking. Transient overvoltage protection by metal oxide arresters with better characteristics than arc-gap arresters. Only arresters with a rating of 1 ka are used. Integrates optimally in the overall PLC network, because ABB not only supplies the line traps, but everything else for PLC systems. Modern production techniques ensure consistent product quality. Backed by 5 years of experience in the design, manufacture and operation of PLC line traps. Quality management systems according to ISO 91. Environmental management system according to ISO 141. Occupational health and safety management system according to ISO 181. Transport of Electrical Energy Substation Line Trap HV Line Line Trap Substation Impedance Z L Coupling Capacitor or CVT Coupling Capacitor or CVT PLC Terminal Coupling Device Coupling Device Z 1 MCD8 MCD8 Z 1 Transmission of Data, Speech and Protection Signals PLC Terminal 2 Communication Networks - DLTC Power Line Carrier Line Traps

ABB Line Traps A wide range of standard production DLTC types DLTC standard production range (other types available on request) Continuous rated current I N (A) Coordination Standard Steady state component of short-time current I kn (ka) Asymmetric peak of short-time current I km (ka) Inductance L tn (mh) 4 IEC 1 1 16 25.5 41 63 IEC 1 16 2 41 51 8 IEC 1 2 25 51 64 1 IEC 1 25 31.5 64 8.5 125 IEC 1 31.5 4 8.5 12 16 IEC 1 4 5 12 128 2 IEC 1 4 5 12 128 25 IEC 1 4 5 12 128 315 IEC 1 4 5 12 128 4 IEC 1 63 8 161 24 Communication Networks - DLTC Power Line Carrier Line Traps 3

ABB Line Traps design Based on more than 5 years of experience Construction of a PLC line trap PLC line traps comprise 3 components: the main coil, a surge arrester and a tuning device. Main coil The construction of the DLTC line traps is based on the former series TLJO and DLTA. Well-proven techniques and materials have been retained and modified to satisfy today s performance requirements. DLTC line traps conform to the latest IEC recommendations. The coil conductor is made of square section aluminium and the turns are spaced by fiberglass spacer rods. There is no insulation around the conductor and therefore no problems can arise due to local hot-spots or cracks in the insulation. This open -type construction provides for excellent cooling by the surrounding air. This method of construction achieves a good RF characteristic with a high Q, low stray capacitance and a high resonant frequency of the coil itself. The entire main coil is impregnated with a two-component epoxy resin of known good outdoor performance. Depending on the rated current and rated inductance, the main coil is wound with either one or several layers. The same fiberglass spacer used for the turns separates the layers of multiple-layer line traps apart. The multiple-layer winding technique enables extremely compact and robust line traps with small diameter and low height to be manufactured. The spider supports in the ends of the coils are held together by the fiberglass spacer rods. To achieve a reliable corrosion-proof connection, the HV terminals are welded directly to the ends of the winding. Generally, vertical flat terminals with 4 or 9 holes are fitted, but round or horizontal flat terminals can be welded to the spiders on request. To avoid additional thermal and mechanical stress in the event of a power system fault, no current is conducted by the spiders. Because of their low weight, DLTC coils can be mounted on coupling capacitors or capacitive voltage transformers (CVT). They can also be mounted on insulator posts or simply suspended. All coils are equipped with lifting eyes on both sides. In addition to a pedestal, a bird barrier and the corona shield needed at the higher power system voltages can also be attached to the spiders. The tuning device and the surge arrester are mounted inside the main coil. 4 Communication Networks - DLTC Power Line Carrier Line Traps

ABB Surge Arresters Providing better protection ABB surge arresters ABB line traps are equipped with a modern surge arrester which does not have a spark gap. Two alternative surge arresters are available for protecting PLC line traps type DLTC. The small- and medium-size line traps are protected by standard ABB station arresters type Polim. Large line traps are equipped with specially designed surge arresters for extremly high electromagnetic fields. They employ the same non-linear metal oxide varistors (MO arrester) that are used in the ABB station arresters. The main advantages of the MO surge arresters are High surge suppression capacity Fast response to the high-rise transient surges which typically occur when isolators across line traps are operated Low, stable level of protection The inherent leakage capacitance of the MO surge arrester is taken into account when designing the tuning device. ABB MO surge arresters are especially designed for operation in the strong electromagnetic fields which prevail inside PLC line traps. In particular they do not contain any unnecessary metal parts in which the magnetic field would induce eddy currents and cause an inadmissible temperature rise. The modification of the MO surge arresters to suit the operating conditions of PLC line traps was only possible because ABB also manufactures this plant equipment and is fully familiar with the problems which arise in practice. The surge arresters used with DLTC line traps have a rated current of 1 ka. Tuning device The tuning device is connected in parallel with the main coil and the surge arrester. It provides a defined impedance or blocking resistance in the frequency band prescribed for the PLC channel. The tuned circuit is usually of the dual-circuit broadband type. This solution has proved to produce the best results in the majority of cases. Many years of successful operation have confirmed that the bandwidth obtained for a given main coil impedance and transient over-voltage withstand is an optimum. Special attention has always been paid to the proper insulation coordination between the main coil, tuning device and surge arrester. Construction of a PLC Line Trap Typical resistance characteristic of a metal oxide surge arrester 3 8 1. 8/2 μs U 3 4 2 7 1 6 7 U/U 3.5 U 2 AC (5/6 Hz) 5 8 9 U 1 1-4 1-2 1 1 2 1 4 1 6 I [A] 1 Main coil 2 Tuning device 3 Protective devices 4 Corona caps (depending on system voltage) 5 Corona rings (depending on system voltage) 6 Bird barriers (option) 7 Terminal 8 Lifting eye 9 Pedestal (option) U 1 = Voltage across the line trap at the continuous current U 2 = Voltage across the line trap at the rated shorttime current U 3 = Protection level of the surge arrester at a test current of 1 ka, 8/2 μs I [A] = Current through surge arrester Communication Networks - DLTC Power Line Carrier Line Traps 5

ABB Tuning Devices Guaranteeing the correct blocking bandwidth Frequency response of a broadband tuned line trap Frequency response of a single frequency tuned line trap Blocking impedance, resistance [Ω] 1 8 6 4 2 Δf 1R Δf 1 Rated Value R b Z b Blocking impedance, resistance [Ω] 12 1 8 6 4 2 Z b R b Rated Value Δf1R Δf 1 5 1 15 2 25 3 5 1 15 2 25 Frequency [khz] Frequency [khz] 8. 8. A tr A tr Δf 2 Tapping loss [db] 6. 4. 2. Δf 2 Δf 2R Rated Value Tapping loss [db] 6. 4. 2. Δf 2R Rated Value A t A t.. 5 1 15 2 25 3 5 1 15 2 25 Frequency [khz] Frequency [khz] Equivalent circuit Equivalent circuit A A L1 L L2 C1 C2 R2 TD C R TD A = Protective device A t = Tapping loss based on A = Protective device A t = Tapping loss based on L1 = Main coil of line trap blocking impedance L = Main coil of line trap blocking impedance TD = Tuning device A tr = Tapping loss based on TD = Tuning device A tr = Tapping loss based on C1, C2, = Tuning device elements blocking resistance C, R = Tuning device elements blocking resistance L2, R2 Z b = Blocking impedance R b = Blocking resistance Rated value of A tr 2.6 db according to IEC 6353 Z b = Blocking impedance R b = Blocking resistance Rated value of A tr 2.6 db according to IEC 6353 6 Communication Networks - DLTC Power Line Carrier Line Traps

ABB Line Traps Conforming to the latest international recommendations Standard values for the blocking resistance of line traps in overhead lines are 4 Ω for bundle conductors and 6 Ω for single conductors. The curves on the right show the blocking bands which can be achieved with broadband line traps for different values of inductance. Detailed frequency tables are available for both methods of line trap tuning and other values of blocking resistance. Alternatively, the line trap can be tuned as a damped single frequency filter. The main characteristic of this type of tuning is its excellent withstand to transient overvoltages. - Field tunable tuning devices are available for line traps with.2 mh and.5 mh. Extensive tests in outdoor switchyards and GIS installations have demonstrated that a large number of transients with extremely short rise times are generated when an isolator across a PLC line trap is operated. These tests supported by computer simulations verified that DLTC line traps with a damped single frequency blocking characteristic withstand such stresses better than broadband line traps. Damped single frequency line traps are therefore recommended for power system voltages from 5 kv upwards and in systems with frequent switching operations. The blocking bandwidth of a damped single frequency line trap for a given main coil inductance is narrower than that of a broadband line trap. Mounting PLC line traps Suspended The line traps have a lug on the upper spider for this kind of installation. A lug on the bottom enables the line traps to be anchored. Multiple suspension points can also be provided. Standing Small and medium-size line traps can be equipped with a pedestal of non-magnetic material for mounting on coupling capacitors, capacitive voltage transformers or insulator posts. Pedestals for mounting on 3 or 4 insulator posts are available for large line traps or medium-size line traps exposed to high mechanical stresses (high winds or earthquakes). Band limits of broadband line traps type DLTC Upper band limit [khz] Upper band limit [khz] 5 4 3 2 1 5 4 3 2 1 2. mh 5 1 15 2 Lower band limit [khz] 2. mh 1. mh 1. mh.5 mh.5 mh.315 mh Applies for blocking resistance R b > 4 Ω Applies for blocking resistance R b > 6 Ω 5 1 15 2 25 Lower band limit [khz].2 mh.315 mh.2 mh The blocking bandwidth of line traps with.2 mh and.315 mh can be tuned in a frequency range of up to 1 khz. For line traps with.5 mh, 1. mh and 2. mh, when intended for use above 5 khz, it has to be clarified with the manufacturer first, whether the selected type is suitable for the required application. Connections The standard versions of the DLTC line traps are supplied with vertical aluminium flat terminals. The arrangement of the terminals permits the conductors to be routed either vertically or horizontally when using standard clamps. Other types of terminal (e. g. round, horizontal or double) or alternative methods of connection are available on request. Communication Networks - DLTC Power Line Carrier Line Traps 7

Contact ABB Switzerland Ltd Power Grids Grid Automation Bruggerstrasse 72 CH-54 Baden, Switzerland Phone: +41 84 484 58 45 (Customer Support Center) E-Mail: communication.networks@ch.abb.com www.abb.com/communicationnetworks 1KHA - 558 - SEN - 11.16 - Printed in Switzerland ABB Switzerland Ltd, November 216. The right to modifications or deviations due to technical progress is reserved.