Zone 2 Field Device Coupler 8 purs eries 9411/24 www.stahl.de > Connection of up to 8 intrinsically safe FCO field devices to the high power > solation between intrinsically safe field devices and nonintrinsically safe fieldbus > hortcircuit protection for each spur > Reduced starting and low shortcircuit current through power management > LED indication of status and faults on each spur > witchable fieldbustermination on board > crew terminals or detachable screw terminals ( purs) eries 9411/24 14125E00 The Zone 2 Field Device Couplers are installed in Zone 2 and connect up to 8 intrinsically safe FOUNDATON TM fieldbus H1 or Profibus PA field devices in Zone 1 to a nonintrinsically safe fieldbus (high power ). The intrinsically safe spurs comply with FCO specifications and are electrically isolated from the. The Field Device Couplers feature a power management to minimize current from the. The couplers are mounted on DN rail or directly in enclosures made of glass fibre reinforced polyester or stainless steel. The cable shields can be connected to earth capacitively at the terminals or directly at the cable screen bus bar (optional). ATEX / ECEx / GOT NEC 505 NEC 506 NEC 500 Class Class Class Class Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 nterface x x x x x x nterface x x x x x x nterface x x x x x x nstallation in x x x nstallation in x x x nstallation in x x x WebCode 20120723 AK00 en 9411F Fieldbus Technology /1
Zone 2 Field Device Coupler 8 purs eries 9411/24 election Table Version Field enclosure Number of channels Terminals Order number (spurs) Zone 2 field without, DN rail mount 8 screw terminals 9411/2431041 device coupler detachable screw terminals 9411/2433041 Note Field enclosures in polyester or stainless steel: Customer specific solutions on request Explosion Protection Global (ECEx) Gas and dust Europe (ATEX) Gas and dust UA (NEC) Gas Certificates and approvals Certificates Further parameters nstallation ECEx BV 08.0057 X Ex na [ia Ga] C T4 Gc [a Da] C BV 06 ATEX E 004 X E 3 (1)G Ex na [ia Ga] C T4 Gc E (1) D [a Da] C in preparation in preparation afety data (CENELEC) per spur FCO (EC 6007927) Max. voltage U o 15.7 V Max. current o 245 ma Max. power P o 960 mw Max. connectable 476 nf / 2878 nf capacitance C o for C/B Max. connectable 0.58 mh / 2.9 mh inductance L o for C/B Max. internal capacitance 1.1 nf C i Max. internal inductance L i Rated insulation voltage U m ECEx, ATEX, Canada ( CFM), Russia (GOTR), UA (FM), Belarus (GOTB) in Zone 2, Zone 22 (dust), Class, Zone 2, Class Division 2 and in the safe area uitable enclosure required e.g. R. TAHL eries 8146 (plastic) or 8125, 8150 (stainless steel) ~ 0 mh 253 V Electrical data Auxiliary power Galvanic isolation spurs to spur to spur Data transmission between and spurs Max. no. of field devices per segment Trunk, not intrinsically safe Connections Voltage range Undervoltage monitoring Max. rated input current Trunk N/OUT not required, the Field Device Coupler is powered from the 1,5 kv AC No galvanic isolation passive, no repeater function 16 (FF H1), 32 (Profibus PA) 2 connections (N, OUT), internally bridged 16... 32 V U < 16 V, spurs deenergised 2 A /2 Fieldbus Technology 20120723 AK00 en
Zone 2 Field Device Coupler 8 purs eries 9411/24 Electrical data Trunk, not intrinsically safe Max. rated input current Max. voltage drop Trunk N/OUT Max. power dissipation ndication Reverse polarity protection Max. number of Field Device Couplers Fieldbus terminator 60 mv 1.8 W Green LED "PWR" (U ) 16 V from ) yes 4 per The field device couplers have a builtin, switchable fieldbus terminating resistor 100 Ω 1 uf (EC 611582). A jumper between the terminals TERM 1 and 2 connects the fieldbus terminating resistance to the. As an alternative, it is also possible to use an external fieldbus terminating resistor eries 9418 at Trunk OUT connection. purs, intrinsically safe FCO Quantity 8 Max. no. of field 1 devices per spur Max. cable length 120 m Max. steady state DC 20 ma output current all spurs Max. steady state DC 41 ma (see manual) current per spur Min. output voltage 10 V at 41 ma Note For correct engineering the R. TAHL tool Fieldbus Wizard shall be used (www.stahl.de). Min. noload voltage 12 V Max. internal 65 Ω resistance Max. shortcircuit 50 ma current ndication per spur Yellow LED "1"... "8" Earthing of cable shields ( and spurs) Direct earthing on the shield bus (option) Capacitive earthing via 4.7 nf at terminal (grounding bolt M6) spurs Capacitive earthing via 2.35 nf at terminal (grounding bolt M6) Power management f the voltage exceeds 16 V, the spurs are switched on one after the other to prevent a high startup current due to the field devices. A short circuit detected on a spur will deactivate the respective spur until the shortcircuit is removed. Regardless of how many spurs are shortcircuited, the is loaded with max one shortcircuit current. This minimises the current consumption of the and the power dissipation under all operating conditions. Fault detection pur shortcircuit ) 42... 50 ma ndication of Yellow LED "1"... "8", flashing shortcircuit per spur Collective error Red LED "ERR" flashes message ndication of spur Yellow LED "1"... "4" flashes quickly causing overload Error indication on field Red LED "ERR" device coupler Electromagnetic compatibility voltage load on spurs: no load 1 x 20 ma 8 x 20 ma 7 x 20 ma 1 x short circuit 16 V 32 ma 58 ma 225 ma 270 ma 32 V 32 ma 50 ma 115 ma 135 ma Tested to the following standards and regulations: EN 61326 (EC/EN 6100041...6 and 11; EN 55022 class B); NAMUR NE 21 (EC/EN 6100041...6, 8 and 11; EN 55022 class B) 20120723 AK00 en Fieldbus Technology /3
Zone 2 Field Device Coupler 8 purs eries 9411/24 Ambient conditions Ambient temperature torage temperature Coupler mounted on DN rails: 40... 75 C 40... 75 C Relative humidity (no < 95 % condensation) Mechanical data ngress protection Enclosure P30 terminals P20 Ex e terminals P30, cover closed (enclosure may be opened in hazardous area while connected to power) Terminals 3pole (,, screen) screw terminals detachable screw terminals only for spurs spurs ( see screw terminals ) rigid 0.2... 4 mm 2 0.2... 4 mm 2 flexible 0.25... 2.5 mm 2 0.25... 2.5 mm 2 flexible, end covering 0.25... 2.5 mm 2 0.25... 2.5 mm 2 sleeves Weight nstallation type nstallation position Fire resistance (UL94) nstallation conditions Connection diagram 0.735 kg on DN rail, EN 50022 (N 35/15, N 35/7.5) or mounting plate vertical or horizontal HB Foundation Fieldbus H1 or Profibus PA Field devices PUR 1 FCO PUR 2 FCO FCO FCO PUR 3 PUR 4 PUR 5 FCO PUR 6 FCO PUR 7 FCO PUR 8 FCO TRUNK N not TERM T1 T2 TRUNK OUT not Foundation Fieldbus H1 or Profibus PA Trunk PowerManagement 06799E02 /4 Fieldbus Technology 20120723 AK00 en
Zone 2 Field Device Coupler 8 purs eries 9411/24 Accessories and pare Parts Designation llustration Description Order number Weight kg Terminating resistor Fieldbus Terminator "Ex m" 9418/0120110 0.080 Fieldbus Terminator "" 9418/0220110 0.080 Fieldbus Wizard Engineering Tool 06501E00 Engineering Tool Engineering tool for segment design of fieldbus foundation or Profibus PA fieldbus installations Download under www.fieldbussolutions.info 07376E00 Fieldbus Power upply Fieldbus power supply and diagnosis 9412/0031011s 0.135 12783E00 Fieldbus power supply, diagnosis and adjustable warning level 9412/0032011s 0.135 12809E00 Earthing bar set 8 K Earthing bar 9411 spring terminal strap with 10 terminals 202775 0.200 04079E00 Earthing bar 9411 screw terminals 161930 0.090 Dimensional Drawings (All Dimensions in mm / inches) ubject to Alterations 204 mm / 8.03 " 168 mm / 6.61 " Ø 5,5 mm / 0.22 " 92 mm / 3.62 " 83 mm / 3.27 " 126 mm / 4.96 " 111 mm / 4.37 " 5,5 mm / 0.22 " 15 mm / 0.59 " 14117E00 9411/243.041 Zone 2 Field Device Coupler without enclosure We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. 20120723 AK00 en Fieldbus Technology /5