Product Overview The HYUNDAI N700E Series High Performance Drives offer powerful control solutions with exceptional speed control and torque response

Similar documents
SJ200 Series Inverter Quick Reference Guide

WJ200 series Pursuing the Ideal Compact Inverter

2011 Industrial Catalog. DRIVES, PAC, PLCs. Industrial Catalog

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

J1000. System configuration

Frequency Converter Fv

Specifying a Variable Frequency Drive s

A1000 Cheat Sheet (Open Loop Vector)

EFC Frequency converters

... Electronic Softstarter...

SAFETY INSTRUCTIONS WARNING

3G3JX AC DRIVES Compact and complete

FRENIC5000MS5 for Machine Tool Spindle Drives

NXL Series Inverters. HVAC Inverters made simple

32VFD Variable Frequency Drives for Centrifugal Chillers

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

NX Series Inverters. HVAC Pocket Programming Guide

SAFETY INSTRUCTIONS WARNING

MSN 70. Streç Film & Alüminyum Folyo Sarým Makinesi. Kullanma Kýlavuzu. Mertsan. Makine San. Tic. Ltd.Þti.

How To Use The Vacon 0 Machinery

Phone: Fax: Web: info@clrwtr.com

SAFETY INSTRUCTIONS. To prevent injury and property damage, follow these instructions during the installation and operation of the inverter.

HF430 AC Drive Pocket Guide

TRAMS TROLLEY-BUSES SUBWAY

VS-606V7 Series Instruction Manual COMPACT GENERAL-PURPOSE INVERTER (VOLTAGE VECTOR CONTROL)

TOSVERT VF-MB1. Functions for lift application

Easy to connect - Easy to configure Easy to install

vacon compact ac drives creating perfect harmony

AC ADJUSTABLE SPEED DRIVES MICRO SERIES INVERTERS

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

vacon x series rugged drives for the real world

SAFETY INSTRUCTIONS. Always follow safety instructions to prevent accidents and potential hazards from occurring.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

1000 Hz High Frequency Custom Software

Discover the power of e-learning! The Quick Guide to AC Variable Frequency

TABLE OF CONTENTS. Fig. 1 EV Pictorial Wiring Diagram 5. Section 2 Inverter Option Modules 6

OPERATING MANUAL. Table of contents. 2 Phase Stepping Motor Driver 2M542. Rev. A. Introduction page 2. Specifications page 2 Timing chart page 3

B a l d o r V S 1 A C M i c r o d r i v e s C o m p a c t. C o s t E f f i c i e n t. R e l i a b l e.

Number 1 in efficiency

VLT AutomationDrive for Marine winch applications

Electronic Control Devices The European Product Catalogue 2007

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

The HVAC SOLUTION DELIVERING POWER...SAVING ENERGY

APPENDIX. SureSERVO QUICK START GUIDE. In This Appendix... Quick Start for SureServo Drives...A 2. Tuning Quick Start for SureServo Drives...

Application Note AN-SERV-006

Operational Overview and Controls Guide. Two or Three Pump IronHeart Lite with Variable Frequency Drives

Fundamentals of Inverter Fed Motors

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

Manual No. YEG-TOE-S OY. VARISPEED F7 Vector Control Frequency Inverter USER S MANUAL

vacon compact ac drives creating perfect harmony

Stroom voor elke toepassing

CONSTRUCTION STANDARDS DIVISION 23 HEATING VENTILATING AND AIR CONDITIONING

GPD 506/P5 Start-up Procedure and Checklist

Diesel Engine Driven Generators Page 1 of 6

Temperature Controller CD401/CD901/CD701/CD501/CD100/CD101 Instruction Manual

MX2. System configuration

MEMOBUS/Modbus Communications

Apéndice E Listado de constantes

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

ABB general machinery drives. User s manual ACS355 drives

Development of the Induction Motor for Machine Tool Spindles and Servo Amplifier SANMOTION S

Clean and compact drive for energy savings. Altivar 1100 Medium-voltage variable speed drive 0.3 to 10 MW. DIA2ED EN.indd 1 22/07/09 11:36:14

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Operational Overview and Controls Guide

BIG SAVINGS FOR A LOT MORE APPLICATIONS

Panorama. Softstarters The complete range

sip Sanyo Modbus Guide Technical Specification Pinouts, Cable Connections & Wiring Issue 2: February 2009 Synapsys Solutions Ltd, all rights reserved

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Display Group Parameters

3753 en /b VE/B - VE/RG Va V riable speed drives

STARVERT ig5a. Compact & Powerful Inverter. 0.4~7.5kW 3Phase 200~230Volts 0.4~7.5kW 3Phase 380~480Volts. Automation Equipment

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16290(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JUL.03,2001 TOTAL PAGE : 7

AC Variable Speed Drive. Powerful Performance. Advanced motor control. 0.75kW 250kW / 1HP 350HP V Single & 3 Phase Input

Fractional to 2 HP DC Drives for Both Non-Regenerative and Regenerative Applications

vacon 100 x & vacon 20 x decentralized ac drives

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Cat. No. I527-E2-02 USER S MANUAL SYSDRIVE 3G3MV. Multi-function Compact Inverter

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Efficient and reliable fans, compressors and blowers

SPEED-Commander Universal frequency inverter. Standard user guide Version 5.x.x

smd Series Drives Modbus Communications Reference Guide

Installation & Operation Manual for Energenics Air-Flow Optimizer

PRODUCTS DC MOTORS BLPM MOTORS AC MOTORS CONTROLLERS

Understanding Variable Speed Drives

Voltech DC1000. Precision DC Bias Current Source

Analog Servo Drive 25A8

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Siemens Standard Drives. Application Handbook

HVAC03C2 HVAC61C2 HVAC03C5 HVAC61C5 NXL HVAC INVERTERS

ABNORMAL OPERATION Error code Display. Specifics Error Code. Subsection Error Code. Subsection and Specifics Error code target

EMERGING DISPLAY CUSTOMER ACCEPTANCE SPECIFICATIONS 16400(LED TYPES) EXAMINED BY : FILE NO. CAS ISSUE : JAN.19,2000 TOTAL PAGE : 7 APPROVED BY:

Adjustment functions for both span and shift have been incorporated

Unidrive M Energy Savings

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

PSR The compact range Description

How To Power A Schen

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Transcription:

Product Overview The HYUNDAI N700E Series High Performance Drives offer powerful control solutions with exceptional speed control and torque response which provides superior vector performance. The N700E s compact size and sensorless vector control technology provides perfectly optimized performance for industrial and commercial applications. Certificates of international standards (UL/cUL, CE) for the N700E series make it perfect for global applications. Compatible with the most common loads such as: fans, blowers, compressors, pumps, mixers, agitators, feeders, centrifuges, cranes, hoists, presses, extruders, and textile spinning machines. Product Specifications Sensorless Vector Control 0.01-400 Hz 150% overload for one minute, CT applications 120% overload for one minute, VT applications 3000 second accel/decel DC braking Auto-tuning Sixteen level multi-speed Adjustable carrier frequencies PID control Frequency jump Analog gain bias Jog run Electronic thermal overload Auto-torque boost, trip history monitor and software lock Speed search function Intelligent input function RS485 - Modbus communications 230 Volt, Single-Phase Model Number List Price Dimensions (Inches) H x W x D Approx. Wt. (Ibs.) 0.5 3 N700E-004SF - 5.04 x 2.67 x 5.04 2.6 1 5 N700E-007SF - 5.04 x 2.67 x 5.04 2.6 2 7 N700E-015SF - 5.04 x 4.25 x 5.6 3.3 3 11 N700E-022SF - 5.04 x 4.25 x 5.6 3.3 230 Volt, Three-Phase Constant Torque 150% Overload Variable Torque 120% Overload Model Number List Price Dimensions (Inches) H x W x D 0.5 3 N700E-004LF - 5.04 x 2.67 x 5.04 2.6 1 5 N700E-007LF - 5.04 x 2.67 x 5.04 2.6 2 7 N700E-015LF - 5.04 x 2.67 x 5.04 2.6 3 11 N700E-022LF - 5.04 x 4.25 x 5.6 3.3 5 17 N700E-037LF - 5.04 x 5.42 x 5.78 4.4 7.5 24 10 30 N700E-055LF - 10.82 x 8.26 x 6.61 9.3 10 32 15 44 N700E-075LF - 10.82 x 8.26 x 6.61 9.3 15 45 20 50 N700E-110LF - 10.82 x 8.26 x 6.61 9.3 20 64 25 73 N700E-150LF - 15.4 x 9.85 x 7.4 16 25 76 30 85 N700E-185LF - 15.4 x 9.85 x 7.4 16 30 90 40 90 N700E-220LF - 15.4 x 9.85 x 7.4 20 Approx. Wt. (Ibs.) NOTES: - All WorldWide Hyundai N700E drives can be used for singe-phase input / three-phase output. Call for engineering assistance to size properly. - Always check the motor full load amps prior to selecting the inverter.

Product Overview The HYUNDAI N700E Series High Performance Drives offer powerful control solutions with exceptional speed control and torque response which provides superior vector performance. The N700E s compact size and sensorless vector control technology provides perfectly optimized performance for industrial and commercial applications. Certificates of international standards (UL/cUL, CE) for the N700E series make it perfect for global applications. Compatible with the most common loads such as: fans, blowers, compressors, pumps, mixers, agitators, feeders, centrifuges, cranes, hoists, presses, extruders, and textile spinning machines. Product Specifications Sensorless Vector Control 0.01-400 Hz 150% overload for one minute, CT applications 120% overload for one minute, VT applications 3000 second accel/decel DC braking Auto-tuning Sixteen level multi-speed Adjustable carrier frequencies PID control Frequency jump Analog gain bias Jog run Electronic thermal overload Auto-torque boost, trip history monitor and software lock Speed search function Intelligent input function RS485 - Modbus communications 460 Volt, Three-Phase Constant Torque 150% Overload Variable Torque 120% Overload Model Number List Price Dimensions (Inches) H x W x D 0.5 1.8 N700E-004HF - 5.04 x 4.25 x 5.6 2.6 1 3.4 N700E-007HF - 5.04 x 4.25 x 5.6 2.6 2 4.8 N700E-015HF -- 5.04 x 4.25 x 5.6 3.3 3 7.2 N700E-022HF - 5.04 x 4.25 x 5.6 3.3 5 9.2 N700E-037HF - 5.04 x 5.42 x 5.78 4.4 7.5 12 10 15 N700E-055HF - 10.82 x 8.26 x 6.61 9.3 10 16 15 22 N700E-075HF - 10.82 x 8.26 x 6.61 9.3 15 23 20 29 N700E-110HF - 10.82 x 8.26 x 6.61 9.3 20 32 25 37 N700E-150HF - 15.4 x 9.85 x 7.4 16 25 38 30 43 N700E-185HF - 15.4 x 9.85 x 7.4 16 30 45 40 57 N700E-220HF - 15.4 x 9.85 x 7.4 17 40 58 50 70 N700E-300HF - 20.86 x 12.28 x 10.63 48 50 75 60 85 N700E-370HF -- 20.86 x 12.28 x 10.63 48 60 90 75 105 N700E-450HF - 21.57 x 13.46 x 11.02 60 75 110 100 135 N700E-550HF - 21.57 x 13.46 x 11.02 66 100 149 125 160 N700E-750HF - 27.48 x 15.6 x 11.02 110 125 176 150 195 N700E-900HF - 27.48 x 15.6 x 11.02 110 150 217 200 230 N700E-1100HF - 29.13 x 18.89 x 11.81 132 200 260 250 285 N700E-1320HF - 29.13 x 18.89 x 11.81 132 250 300 300 370 N700E-1600HF - 36.22 x 19.92 x 15.35 242 300 415 350 450 N700E-2200HF - 36.22 x 19.92 x 15.35 242 400 525 450 600 N700E-2800HF - 40.15 x 31.73 x 15.55 375 500 656 550 680 N700E-3500HF - 40.15 x 31.73 x 15.55 375 Approx. Wt. (Ibs.) NOTES: - All WorldWide Hyundai N700E drives can be used for singe-phase input / three-phase output. Call for engineering assistance to size properly. - Always check the motor full load amps prior to selecting the inverter.

Specifications Specification Control Method Output Frequency Range Frequency Accuracy Frequency Resolution V/f Characteristic Overload Capacity Acceleration/Deceleration Time DC Braking Frequency Setting Standard Operator External Signal Description Sensorless vector PWM method 0.01~400 Hz Digital: Max frequency ±0.01%; Analogue: Max frequency ±0.1% Digital setting: 0.01 Hz (<100 Hz), 0.1Hz (>100 Hz) Analogue: Max frequency / 500 (when DC 5V input), Max frequency / 1,000 (DC 0~10V, 4~20mA) Base frequency: 0~400 Hz free set Torque pattern selection available (constant torque / reduced torque) 150%, 1 minute (heavy duty), 120%, 1 minute (normal duty) 0.1~3,000 sec (linear / curve selection available) 2 nd Acceleration / Deceleration setting available Performs between min. frequency and established braking frequency Level and time setting available Set by volume up / down key 1 W, 1~2 kω variable resistor DC 0~10 V (input impedance 10 kω), 4~20 ma (input impedance 250Ω) Input Forward Reverse Start / Stop Standard Operator External Signal Run key / Stop key (change forward / reverse by function command) Forward run / stop, reverse run / stop set by terminal assignment (1a, 1b selection available) Output Main Functions Intelligent Input Terminal Intelligent Output Terminal Frequency Monitor Alarm Output Contact FW (Forward), RV (Reverse), CF1~4 (Multi-speed), RS (Reset), AT (Analog input current / voltage Transfer), USP (Unattended Start Protection), EXT (External Trip), FRS (Free Run Stop), JG (Jogging Command), SFT (Software Lock Command), 2CH (2 nd Acceleration / Deceleration), SET (2 nd Motor Constants Setting) RUN (Run Signal), FA1 (Frequency Arrival Signal [at the set frequency]), FA2 (Frequency Arrival Signal [at or above the set frequency]), OL (Overload Advanced Notice Signal), OD (Output Deviation of PID Signal), AL (Alarm Signal) Analog meter (DC0~10V full scale, Max 1 ma) Analog output frequency signal and analog output current signal Analog output voltage signal selection available OFF when inverter alarm (b contact output) / Auto switch ON and OFF / Intelligent output terminal use available Auto-tuning, AVR Function, V/F Setting, Curve Accel. / Decel. Selection, Frequency Upper / Lower Limit, 6 Level Multi-speed, Start Frequency Set, Carrier Frequency Setting (0.5~15 khz), PID Control, Frequency Jump, Analog Gain Bias Control, Jogging Run, Electronic Thermal Level Control, Retry, Auto Torque Boost, Trip History Monitor, Software Lock, S-shape Accel. / Decel., Frequency Conversion Display, USP, 2 nd Control Protective Functions Ambient Temperature Storage Temperature Environmental Ambient Humidity Conditions Vibration Location Options Over-current Protection, Overload (electronic thermal), Over-voltage, Communication Error, Under-voltage, Output Short, USP Error, EEPROM Error, External Trip, Ground Fault, Temperature Trip -10~50 C (over 40 C: set carrier frequency below 2.0 khz) -20~60 C (while transporting: short time) Below 90% RH (non-condensing) 5.9 m/s2 (0.6 G). 10~55 Hz (JIS C0911 test methodology) Less than 1,000 m above sea level, Indoor (no corrosive gas, no flammable gas, no oil-drop, no dust) Remote operator, Remote operator cable, Regenerative braking resistor NOTES: - All WorldWide Hyundai N700E drives can be uses for singe-phase input / three-phase output. Call for engineering assistance to size properly. - Always check the motor full load amps prior to selecting the inverter.

Terminal Connections Diagram

Drive Outline Drawings N700E-004SF/007SF, N700E-004LF/007LF/015LF N700E-015SF/022SF, N700E-022LF, N700E-004HF/007HF/015HF/022HF N700E-037LF/HF N700E-005LF/055HF, N700E-075LF/075HF N700E-110LF/110HF t Company ment.com.875.0280

Drive Outline Drawings N700E-150LF/150HF, N700E-185LF/185HF, N700E-220LF/220HF N700E-300HF, N700E-370HF N700E-450HF, N700E-550HF N700E-750HF, N700E-900HF t Company ment.com.875.0280

Drive Outline Drawings N700E-1100HF, N700E-1320HF N700E-1600HF, N700E-2200HF N700E-2800HF, N700E-3500HF t Company ment.com.875.0280

HYUNDAI Standard Duty Drive Package Product Overview 3-500 Full panel surge suppression Main CB with padlockable disconnect 3% line reactor CT and VT ratings Three-phase NEMA 12 enclosure with filters and fan cooling Door mounted WorldWide SID1 with: - Start / Stop buttons - Help button - Speed control buttons - Hand, Auto Buttons - Plain Text Programming Heavy duty mounting ears Heavy duty lifting strap Voltage Constant Torque Variable Torque Model Number 480 3 1.5 7.2 WWESDA-DRV12-003-4-480 5 9.2 --- --- WWESDA-DRV12-005-4-480 7.5 12 10 15 WWESDA-DRV12-007-4-480 10 16 15 22 WWESDA-DRV12-010-4-480 15 23 20 29 WWESDA-DRV12-015-4-480 20 32 25 37 WWESDA-DRV12-020-4-480 25 38 30 43 WWESDA-DRV12-025-4-480 30 45 40 57 WWESDA-DRV12-030-4-480 40 58 50 70 WWESDA-DRV12-040-4-480 50 75 60 85 WWESDA-DRV12-050-4-480 60 90 75 105 WWESDA-DRV12-060-4-480 75 110 100 135 WWESDA-DRV12-075-4-480 100 149 125 160 WWESDA-DRV12-100-4-480 125 176 150 195 WWESDA-DRV12-125-4-480 150 217 200 230 WWESDA-DRV12-150-4-480 200 260 250 285 WWESDA-DRV12-200-4-480 250 300 300 370 WWESDA-DRV12-250-4-480 300 415 350 450 WWESDA-DRV12-300-4-480 400 525 450 600 WWESDA-DRV12-400-4-480 500 656 550 680 WWESDA-DRV12-500-4 - List Price NOTES: - Single-phase input available - 230 Volt available