Current and voltage measuring relays



Similar documents
Pilot-wire differential relay for lines with two or more terminals

Trip circuit supervision relay. Type RXTCS

Voltage Regulator SPAU 341 C. Product Guide

Bus differential relay REB phase 1MRK BEN Page 1 Issued: September 2006 Revision: C Data subject to change without notice

Circulating Current Relay. Type IRXm

Both variants can be used for measuring the positive sequence voltage Up or the negative sequence voltage Un.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Capacitor Protection Relay SPAJ 160 C. Product Guide

Busbar differential protection

Three-phase monitoring relay CM-PFE

Safety technique. Emergency stop module BO 5988 safemaster

Relion 605 series. Self-powered feeder protection REJ603 Product Guide

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

High EMI immunity. I/O events are timestamped locally on each module.

38 Series - Relay interface modules A

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Catalog. Arc Guard System TM TVOC-2

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

T Substation Maintenance and Commissioning Test Equipment

Type SA-1 Generator Differential Relay

Panel Meters and Controllers Modular Panel Meter Type EDM 35

MasterINTERFACE 39 Series - Relay interface modules

E-STOP relays, safety gate monitors

38 Series - Relay interface modules A

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

3753 en /b VE/B - VE/RG Va V riable speed drives

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

MasterINTERFACE 39 Series - Relay interface modules

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Unified requirements for systems with voltages above 1 kv up to 15 kv

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

Disturbance Recoder SPCR 8C27. Product Guide

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

RY2 miniature industrial relays

FREJA 300 Relay Testing System

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Auxiliary Relay. Type P8n, PQ8n, PN8n

Energy Management Energy Meter Type EM23 DIN

R448 & R448 V50 A.V.R.

Analog signal converters CC-E I/I Current / current isolators

Waveguide Access Point WGA631. Product Guide

Relion 605 series. Feeder protection and control / Feeder protection REF601 / REJ601 Product Guide

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

RM4TG20 three-phase network control relay RM4-T - range V

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

R.C.C.B. s two-pole LEXIC

Remote Monitoring and REC 501 Control Unit Product Guide

Relay mounting systems

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

SINEAX U553 Transducer for AC Voltage

Meter Relays. 077 Series Analogue Meter Relays. Features. Applications

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

LM118/LM218/LM318 Operational Amplifiers

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Power transformers. Special transformers Railway

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

40 Series - Miniature PCB/Plug-in relays A. Features

Power Meter Series 700

R438 A.V.R. Installation and maintenance R 438. This manual is to be given to. the end user T10. Armature 6- Field X2 Z1 X1 Z2 E+ E- 0V

49 Series - Relay interface modules A. Features

CONTROLS DATA MANAGEMENT PROCESS AUTOMATION EUROCUBE. General purpose single phase thyristors and solid state relays Product data.

Section D..General Auto Electrical Corporation

Earth Fault Detection Basics in Theory

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Manual motor starter MS116

Thyristor-controlled power supplies and battery chargers

CONSTANT CURRENT REGULATOR INDUPERM TYPE CCR 951. Standarddescription of CONSTANT CURRENT REGULATOR TYPE CCR 951.

14.5GHZ 2.2KW CW GENERATOR. GKP 22KP 14.5GHz WR62 3x400V

Safety automation solutions

Low and High Voltage Power Supplies

Quick Connect. quick - simple - efficient.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Rack mounted telephone- and leased line modem for industrial applications

60 Series - General purpose relays 6-10 A. Features

Digital Pressure Measuring Instrument MDR480

15 Series - Electronic step relay and dimmer. Features SERIE

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

Applications. diris_826_a_1_gb_cat

Flexible Counter Series in DIN size 24 x 48 mm

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

DS 600. A contact free flux gate based current measurement sensor 600A rms

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

Programmable Single-/Dual-/Triple- Tone Gong SAE 800

Contact expansion modules

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

Electronic overload relay EF19 and EF45

Arc Protection Relay REA 10_. Product Guide

Transcription:

Current and voltage measuring relays RXIK 1, RXEEB 1 and Page 1 Issued June 1999 Changed since July 1998 Data subject to change without notice RXIK 1 RXEEB 1 (SE980082) (SE980081) (SE970869) Features Application RXIK low current relay, 50-60 Hz and dc High sensitivity 0,5-2 ma ac Low power consumption in measuring circuit, 20 µw High overload capacity, 125 ma continuously RXIB high speed current relay, 50 or 60 Hz Operate time 4 ms Resetting time 5 11 ms The current and voltage measuring relays are mainly intended for power and system industrial applications. The relays should be mounted on terminal bases and combined with auxiliary relays, time relays etc. The current relay RXIK 1 is used where high sensitivity is required, e.g. in the shaft current relay type RARIC, where a variant of RXIK 1 constitutes the measuring unit. When shunt connected, the relay can be used to measure large direct currents. The shunt wires may be long and have small area as the relay power consumption is very low. In conjunction with additional units, special versions of RXIK 1 may be used in e.g. overcurrent relays, neutral point voltage relays and differential relays to operate even at very low frequencies. 10 ma to A total range for four models Low CT burden and high overload capacity RXEEB low voltage relay, dc High sensitivity 0,1-1,2 and 1-12 V dc 0-0,12 and 0-1,2 V setting of hysteresis Low power consumption in measuring circuit, down to 0,056 µw High overload capacity, 0 V continuously The current relay is generally used where high-speed and consistent operate and reset times are required. Its speed and consistency make the RXIB especially suitable for breaker-failure applications where it is important that the set breaker-failure time is not unduly influenced by variations in operate or reset time of the current-measuring relay. The RAICA breaker-failure relay, for example, incorporates the RXIB for its currentmeasuring function. Similarly, the RXIB s speed and precision in both operate and reset time are ideal for high-speed current-blocking relay applications. For example, to supervise the operation of transformer sudden-pressure relays, which may operate incorrectly as a result of severe external faults. The RXIB is then used in a protective system which responds rapidly to the external fault condition, operating quickly enough to open the pressure relay trip circuit before the pressure- relay has operated.

Page 2 Application (cont d) Additionally, this high-speed relay can be used to improve the security of other sensitive high-speed relays by modifying their pick-up setting without adversely affecting overall operating time. The RXIB should also be considered for high-set direct trip applications because of its high-speed and low transient overreach. The dc voltage relay RXEEB 1 has high sensitivity. The relay can be used in control circuits, to monitor and indicate voltage levels or, via a tachometer generator, rotation speed. The version with normally energized output terminal can also be used in equipment for lifts or cranes where, for safety reasons, failure to operate due to interruption of the auxiliary power supply is not accepted. Design The RXIK 1 is a static, sensitive, high-speed ac and dc overcurrent relay with two changeover contacts. It consists mainly of a level detector with an amplifier, a potentiometer, RC-circuits and regulating (zener) diodes. The operate value is set with a knob at the front. To reduce the risk of undesired operation upon high frequency signals, the input has an RC-circuit which causes the operate value of the relay to increase with the frequency. The output circuit has a smoothing filter which ensures stable function of the output relay. The measuring input is galvanically connected with the terminal for the auxiliary voltage (±12 V dc). Therefore the auxiliary voltage should be supplied via galvanically isolated converters. Suitable converters are RXTUG 22H for dc and RXTUB 2 for ac voltage. RXIK 1 can be used for measuring in both voltage and current circuits. The input is therefore connected both to current terminals 31 and 41 and to voltage terminals 21 and 22. A short-circuiting connector, type RTXK, is supplied with ac current measuring relays. The connector is mounted on the rear of the terminal base (not supplied). The relay current-measuring is fed through the RTXK so that the current transformer secondary circuit is automatically short-circuited when the relay is removed from the terminal base. If the short-circuiting function is not required, e.g. if RXIK 1 is connected to a shunt, connection can be made to the current terminals (31 and 41) via a connector RTXI or to the voltage terminals (21 and 22). The relay occupies one seat (2U 6C). The is a static, high-speed ac overcurrent relay. It consists mainly of an air-gapped input current transformer with three setting taps on the primary side, voltage converter, rectifier, level detector, potentiometer for setting, and amplifier (which drives a reed-type output relay with one make contact). The voltage from the input CT is converted to a three-phase quantity to reduce the ripple volt-age at the output of the rectifier circuit. This technique reduces filtering requirements, thus contributing to the relay s high speed on both operate and reset. The operating value is set by means of the potentiometer knob which can be continuously adjusted from one to three times the scale factor (I s ). The scale factor (I s ) is changed by reconnecting a lead to one of three positions on a screw-type CT tap block, located at the lower right side of the module face plate. In order to avoid opening the CT secondary circuit, reconnection of the scale factor is only to be carried out when the relay is withdrawn from the terminal base. There are four sets of Reconnectible scale factors available: Scale factor, I s 10; 25; 50 ma 0,1; 0,25; 0,5 A 0,2; 0,5; 1 A 1; 2,5; 5 A Two variants of RXIB are available with respect to auxiliary voltage. One can be reconnected (via a screw-type block at the upper right side of the face plate) for dc 36 and 48-55 V, the other for dc 110-125, 220 and 250 V. Auxiliary voltage is normally supplied directly from the station battery. A short-circuiting connector, type RTXK, is supplied with ac current relay modules. This connector mounts on the rear of the terminal base (not supplied). The relay current-measuring circuits is fed through the RTXK so that the current transformer secondary circuit is automatically short-circuited when the relay is removed from the terminal base. The relay occupies two seats (2U 12C).

Page 3 The RXEEB 1 is a static dc voltage relay with electronic output. It measures the absolute voltage or only the positive or negative dc voltage. The relay requires auxiliary voltage dc ±24 V or 48 V with the supply galvanically isolated from the input signal source. Auxiliary output relays suitable for use with RXEEB 1 are RXMA 1, RXMB 1, RXMC 1, RXMT 1, RXMM 1 or RXME 1. The relay occupies one seat (2U 6C). Technical data RXIK 1 Current scale, I s Operate value dc Input impedance Overload capacity Resetting ratio Operate time Resetting time ac dc 0,5-2 ma, 50-60 Hz approx. 1,35 x set value 82 ohm 125 ma cont. 500 ma in 1 s > 99% > 80% 10-30 ms at 1,3 x I s approx. 200 ms at 10 x I s Auxiliary voltage ±12 V ±20% Permitted ambient temperature -20 C to +55 C Power consumption: Current circuit Auxiliary voltage Insulation tests: Dielectric test Impulse test Disturbance tests: Power frequency test Fast transient test 1 MHz burst test Dimensions Weight Contact data: No. of contacts Max. system voltage ac or dc Current carrying capacity continuously during 1 s Making and conducting capacity with an inductive load L/R > 10 ms during 200 ms during 1 s Breaking capacity ac PF > 0,1 dc L/R < 40 ms 48 V 110 V 220 V approx. 20 µva at lowest value 0,7 W before operation 1,3 W after operation 2,0 kv 50 Hz 1 min 5 kv 1,2/50 ms, 0,5 J 0,5 kv 50 Hz 4-8 kv 2 min 2,5 kv 2 s 2U 6C modules 0,2 kg 2 change-over 250 V 4 A 10 A 20 A 10 A 0,5 A 0,2 A 0,1 A

Page 4 Technical data (cont d) Total scale range 10 ma- A Rated frequency, f n 50 or 60 Hz Auxiliary voltage, EL 36, 48-55 or 110-125, 220, 250 V dc + 20% Operate time at instantaneous current change from 0 to 1,1 x set value 2,5 x set value 10- ms 4-6 ms Resetting ratio > 70% Resetting time at instantaneous current change to 0 from 1,1 x set value 70 x set value 5 ms 10-11 ms Consistency of operate value/ setting and graduation error (% of highest setting) <1/<5 (<1/<10 for I s = 5 A) Percent change in operate current: at frequency change within f n ±5 Hz per C temperature change per % auxiliary voltage change Transient overreach at lowest/ highest setting Permitted ambient temperature Power consumption Auxiliary voltage circuit at rated dc voltage 48/55 V 110/125 V 220/250 V Current circuit Overload capacity and power consumption Scale factor I s 10 ma 25 ma 50 ma 0,1 A 0,25 A 0,5 A 0,2 A 0,5 A 1 A 1 A 2,5 A 5 A Insulation tests: Dielectric test, Voltage circuits to contact circuits and earth Current circuits to other circuits and earth Impulse voltage test -2,5%/Hz < 0,% 0,05% 10/10% at τ > 10 ms -25 C to +55 C Before operation After operation 0,7/1,2 1,2/1,6 W 0,5/0,7 1,1/1,4 W 1,6/1,8 2,3/2,6 W Overload Cont. A 0,30 0,70 1,2 2,7 6,5 10 6,8 11 20 20 1 s A 4,4 12 33 100 180 180 350 350 2,0 kv, 50 Hz, 1 min 2,5 kv, 50 Hz, 1 min 5,0 kv, 1,2/50 µs, 0,5 J 0,5 s A 5,7 19 43 130 300 300 300 450 450 Power cons. I = I s mva 5 6 7 6 7 9 6 9 18 18 55 0

Page 5 Disturbance tests: Power frequency test Fast transient test 1 MHz burst test Dimensions Weight Contact data: No. of contacts Max. system voltage dc/ac Current carrying capacity (for already closed contact) 200 ms/1 s continuously 0,5 kv, 50 Hz, 2 min 4-8 kv, 2 min 2,5 kv, 2 s 2U 12C modules 0,7 kg 1 make 250/250 V 3/2,5 A 2 A Making and conducting capacity L/R > 10 ms, 200 ms/1 s 2/2 A Breaking capacity ac PF > 0,1 max. 250 V 0,6 A dc L/R < 40 ms 24/48 V 110/125 V 220/250 V 1/0,5 A 0,2/0,16 A 0,1/0,08 A RXEEB 1 Operate dc value, adjustable (1-12) x U S Scale factor, U S (Reconnectable) 0,1 V or 1 V Setting and graduation error (% of highest setting) < 5 Hysteresis, adjustable (the difference between operate value and reset value) (0-1,2) x U S Overload capacity continuously 0 V Input resistance: Input voltage < 12 V For input voltages > 12 V < 0 V Output dc voltage Permitted output current Operate time at instantaneous voltage change from 0 to: 1,3 x set value 2 x set value Auxiliary dc voltage, EL 180 kohm 100 kohm 24 or 48 V < 100 ma < 30 ms < 25 ms ±24 V or 48 V Permitted auxiliary voltage deviation -20% to +10% Permitted ambient temperature -20 C to +55 C Power consumption auxiliary voltage circuit measuring circuit, highest/ lowest setting Percent change in operate and reset voltage: per % auxiliary voltage change 1-12 V 0,1-1,2 V per C temperature change excl. aux. relay 1,6 W 0,8 mw/0,056 µw < 0,05%/% < 0,%/% < 0,%/ C

Page 6 Technical data (cont d) RXEEB 1 Insulation test: Dielectric test Impulse voltage test Disturbance test: 1 MHz burst test common mode differential mode Dimensions Weight Not applicable 5,0 kv, 1,2/50 µs, 0,5 J 2,5 kv, 2 s 1,0 kv, 2 s 2U 6C modules 0,25 kg Ordering and terminal diagrams Specify for each relay; Type Quantity Ordering No. Scale range RXIK 1 Ordering No. RK 418 004-AA 13 12 11 16 14 Ι > 28 18 + 12V 12V 0 21 31 + Ι 41 (96000147) Ordering No. selection table; Ordering No. RK 413 140-.. RK 413 141-.. Rated auxiliary dc voltage V (EL) 36, 48-55 V 110-125, 220, 250 V 1 114 Ι > 224 225 + EL 131 Ι 141 (96000148) Please note that the ordering number is completed with letters from the selection table below, depending on measuring frequency and scale range.

Page 7 Letter selection table Frequency Scale range (A) 0,01-0, 0,1-1,5 0,2-3 1-50 Hz BB BC BD BE 60 Hz CB CC CD CE Example: A 48 V dc relay with 1- A setting range for 50 Hz has the ordering number RK 413 140-BE. RXEEB 1 With normally nonenergized output terminal With normally energized output terminal RK 427 102-AD RK 427 102-BD 17 27 25 24 26 18 28 U > 13 11 0 24V 24V+ 21 1) (96000149) 1) 48V output relay U s = 0,1 V U s = 1 V Connect 18 to 28 ±U ±U Connect 25 to 26 -U Connect 25 to 24 References Breaker failure relay RAICA 1MRK 505 005-BEN RARIC shaft current relay RXMB 1, RXMC 1 auxiliary relays RXMA 1, RXME 1, RXMM 1, RXMT 1 auxiliary relays COMBIFLEX accessories incl. power supply COMBIFLEX connection and installation components 1MRK 502 003-BEN 1MRK 508 006-BEN 1MRK 508 0-BEN 1MRK 513 004-BEN 1MRK 513 003-BEN Manufacturer ABB Automation Products AB Substation Automation Division SE-721 59 Västerås Sweden Tel: +46 (0) 21 34 20 00 Fax: +46 (0) 21 14 69 18

Page 8