RANGER. select TIMER MODULE PROGRAMMABLE. The OPERATING AND FITTING INSTRUCTIONS

Similar documents
Fused Spur Time Switch

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

PS42309C INSTRUCTION MANUAL

Drayton Digistat +2RF/+3RF

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

Operating instructions for built-in electronic timers with Day and Week programms. Series 884

EK908FHL - Thermostat for floor heating

DAB+ / FM Tuner Model: TU-201

OPERATING INSTRUCTIONS

CR Band Auto Set Dual Alarm Clock Radio ROBERTS. Sound for Generations. Please read this manual before use

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

CR9986 ROBERTS. Dual Alarm CD Clock Radio. Sound for Generations. Please read this manual before use

Operating Instructions DT, PRT, PRT/HW PRT-R, PRT-R2

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

Wireless 7 Day Programmable Room Thermostat

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

User Manual THR840DUK Digital Thermostat

TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions

INSTALLATION AND OPERATING INSTRUCTIONS

AM / FM Tuner + RDS. Model: TU

Time Recorder. User Manual. PDF created with FinePrint pdffactory trial version

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

PROGRAMMING & OPERATING INSTRUCTIONS CL5000 AUDIT TRAIL

PR-2500 Portable Receiver. Owner s Manual

WIRELESS HOME ALARM SYSTEM (WHA1)

STERILIZERS, LABORATORY DRYING OVENS

IN-OUT Thermometer with Cable Free Sensor and Clock

INFRARED QUARTZ WALL HEATER

LUCCI AIRFUSION QUEST II CEILING FAN

Manual for Fire Suppression & Methane Detection System

System pro M DT1-IK DT1-IK/24V DT1-IK/DCF DT2-IK 2CSM204275R0611 2CSM204285R0611 2CSM204295R0611 2CSM204325R0611

CAD-05 Kit GSM Auto Dialer. Owner s Manual

User Manual. Humidity-Temperature Chart Recorder. Model RH520

767 Diagnostic System

Operation Guide 3M-22

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Your Simple Guide to Battery. Replacement. Customer Care:

THERMONET UNDERFLOOR HEATING STANDARD THERMOSTAT KIT STOCK CODE 5260

FG MOISTURE MONITOR Installation & Operation Manual

ES-LCD User Control SD Card Location

PK5500 v1.1 Installation Instructions

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

AUTOMATIC TRANSFER SWITCH CONTROL UNIT OPERATOR S MANUAL

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

Model Owner s Manual. Español - P. 19 Français - P. 39

EBDSPIR-PRM, EBDSPIR-PRM-IP

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

LCD Display. Function keys. Stand. Adapter socket

Mini Timer Owner's Manual. Model MT13A

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

CHAPTER 11: Flip Flops

T7400. Guest Paging System. Long Range Systems, Inc Chartwell Dr., Dallas, TX V6.21 and later

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

CM702 PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Ground Resistance Clamp On Tester

How To Program An Autodialer

AC-115 Compact Networked Single Door Controller. Installation and User Manual

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Secure Keypads for access control

Operating instructions IV / 2007

Installation & User Instructions

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

User s Guide. Sprinkler Timer with Computer Programming Option. ECXTRA Features

Portable Air Conditioner

SETTING UP YOUR 6000 SERIES TIME RECORDER

Wireless Indoor/ Outdoor Thermometer

Alarm Clock USER GUIDE

H203D 中文 GB Version 1

PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA

it500 Internet Thermostat INSTALLER MANUAL

Service Guide. Gateway M275

Water Tank Level Monitor

User's Guide. Integrating Sound Level Datalogger. Model Introduction

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

EM6556 e-domotica Mini Switch

ExStik TM ph Waterproof Meters

HP Pavilion All-in-One MS200 series PC. Upgrading and Servicing Guide. Printed in

ATOMIC CLOCK WITH OUTDOOR WIRELESS TEMPERATURE

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

HWS100 Wireless Home Security System


OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

Owner s Guide. ca6554

Disassembly Procedure

Wireless Home Security Alarm System AM 500

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

Product Information Sheet UH36 Hi Pot Tester

Installation Instructions

Alarm Security Kit - NVR

GB/DAS User Instruction

5W LED Energy Saver PIR Bulkhead

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Transcription:

select ELECTRICAL The RANGER PROGRAMMABLE TIMER MODULE OPERATING AND FITTING INSTRUCTIONS GUARANTEE The Select Ranger is guaranteed for five years from date of purchase to be free from defects in materials and workmanship. This only applies if the Select Ranger is used in the correct way. The guarantee is also conditional on the product not having been tampered with, modified or subject to attempted repairs. Your statutory rights as a customer are not affected. If the Select Ranger is faulty please return to place of purchase. UK PATENT No. 2 290 418 HK PATENT No. 10044303A Philex Electronic Ltd, Philex House, 110 The Broadway, West Hendon, London NW9 7PP

THE SELECT RANGER PROGRAMMABLE TIMER Thank you for purchasing the Select Ranger. A high quality timing system that will allow you a facility that has never previously been available. Ingenious design and foresight has enabled us to produce an innovative product which will allow you to set switches and sockets to a timing device. Please read the following instructions carefully and heed all warnings, especially about electricity. 1. General Features 7 ON and OFF programs per day with 1 minute step 24 hour display mode 7 days/mon-fri/sat-sun/or each day settings pair (ON & OFF) selection 1. 7 days all the same 2. a) Mon-Fri the same b) Sat-Sun the same 3. Individual settings for each day Override programmable countdown timer by a separate key activation (Ranger 2 & 3) ON/OFF/AUTO/ RANDOM/ COUNTDOWN MODE/ SELECTION All separate for each model Summer time setting Manual ON/OFF. For continuous operation Reset Button (resets to zero) 6 keys: DAY, HOUR, MIN, TIME SET, PROG and MODE (Ranger 1) 7 keys: DAY, HOUR, MIN, TIME SET, PROG, MODE and COUNTDOWN (Ranger 2 & 3) 2. Electrical Specifications Rated voltage 250V~/ current 6A (EN60669)m current 13A (EN60730) Timer accuracy to +/-2 sec per day at 25C Operating temp: 0 to 50 degrees C Uses 1 x AAA alkaline non-rechargeable battery (not included). Not suitable for use with rechargeable batteries For continuous operation 3. Contents: Timer Module 2x Main Bracket 2x Bracket extension piece 1x Angle Bracket (can be easily removed for your convenience) Retaining screws (already fitted) + 2 extra short screws 2x extended switch/socket screws 1x one-way connector terminal block 1x adhesive pad Instructions 4. Battery Connection Remove battery cover on front of appliance Place 1 x AAA into compartment ensuring + to right / - to left Replace cover NB: If battery is inserted incorrectly, wait 30 seconds before replacing correctly. By utilising a battery circuit your Select Ranger timer programme is not affected by a power failure. a d e h DAY TIME SET S PGM MO TU WE TH FR SA SU OFF AUTO ON RAND HOUR PROG COUNTDOWN MIN MODE b c f g 5. Keyboard definition a. Day. set day of week toggle output in AUTO/RANDOM/COUNTDOWN MODE b. Hour. Set current time and program time c. Min. Set current time and program time, changes minutes in countdown mode d. Time Set. Set the current time e. Prog. Select and set program f. Mode. Select the operation mode g. Countdown. Activate the countdown timer mode On immersion and professional models only h. Reset 1

6. Power Up All segments will be ON for 2 secs after battery insertion Default time: 00:00 Monday All program timers are un-set i.e. : Default operation mode : manual OFF If battery is removed for any reason, wait 30 seconds before re-insertion S PGM MO TU WE TH FR SA SU 00: 00 OFF AUTO ON RAND 7. Display Mode Normal time display Timer Clock displays in day, hour and minute Colon flashes at a rate of 1Hz Clock updates every minute Other Indicator represents output is ON Indicator represents output is OFF MO OFF 00: 00 Countdown timer display On immersion heater and professional models only (Ranger 2 & 3) Timer displays in MINUTE only Other Indicator shows when the timer is setting and flashes when the timer is counting 8. Setting Mode Clock Setting Mode Available in Manual ON, Manual Off and AUTO mode only If setting in Summer Time, read section below Press and continually hold key TIME SET to enter in clock setting mode Colon will become solid Press either HOUR MIN or DAY to set the clock time and day Hold key HOUR MIN or DAY for 2 sec to enter fast advance (continuous turnover will commence) Release key TIME SET will set the clock and exit the clock setting mode Clock second will be set to ZERO once HOUR, MIN or DAY is pressed NB: Don t forget the special Summer Time setting - see section below : PGM -- -- Summer Time Setting Mode Available in Manual ON, Manual OFF and AUTO modes only Press TIME SET and PROG simultaneously for 3 seconds to set S indicator ON when activated Clock advances one hour If setting clock during Summer Time, set for one hour early, then advance time using the procedure above Winter Time, follow procedure above to return clock to winter setting 2 75 S WE 0: 45 AUTO

Program Setting Mode 1. Available in Manual ON, Manual OFF and AUTO modes only 2. Press PROG to enter setting mode 3. Prg1 will be shown : PGM -- -- Press TIME SET to toggle between countdown timer and normal clock display Press COUNTDOWN to exit countdown timer and change to return to auto mode 75 4. There are up to 7 program modes 5. ON and OFF are designated by the relevant symbols 6. : indicates there are no presets in place 7. Press DAY to all days MON-SUN, MON-FRI, SAT-SUN, individual days, program clear and then repeat 8. Press HOUR, MIN to set the program time (fast advance as previous) 9. Press PROG to Prg1 OFF s program (or next in sequence) 10. To set remaining programs repeat from step 7 11. Press PROG again to advance the program number 12. Press TIME SET to exit setting mode 13. Auto return to clock if idle for 3 mins Example 1: To set ON Example 2: To set OFF MO TU WE TH FR SA SU PGM 1 06: 30 MO TU WE TH FR SA SU PGM 1 09: 45 Countdown Timer Setting Mode On immersion heater and professional models only (Ranger 2 & 3) Press COUNTDOWN to enter mode Press key MIN within 5 secs to set the countdown timer Clock shows 75 and cycles down in 15 minute segments (75, 60, 45, 30, 15, 1, then back to 75) Countdown timer will activate if no other key is pressed within 5 seconds indicator will flash during countdown Manual Off Mode Press MODE to select MANUAL OFF mode OFF indicator displayed Normal clock display All programs are ignored Output is permanently OFF Allows both Clock setting and Program setting Auto Mode Press MODE to select AUTO indicator ON Normal display clock Press DAY to toggle output Allows both Clock setting and Program setting Program output control is activated NB If there are program time overlapping, the higher program number has the highest priority. PROG OFF always has priority over PROG ON Manual ON Mode Press MODE to select ON indicator displayed Normal clock display All programs are ignored Output is permanently ON Allows both Clock setting and Program setting Random Mode On security lighting and professional models only Press MODE to select RAND indicator ON Normal clock display All programs are ignored Clock setting and Program setting is not possible Random output control is activated Frequency: 4-12 times per day ON period: 5-60 minutes Output is ON when activated 3

WARNING: DISCONNECT MAINS POWER PRIOR TO INSTALLATION FITTING INSTRUCTIONS The Select Ranger comes complete with a universal bracket which will allow you to fit it to single or twin switches, also single or twin socket outlets (switched/unswitched). N.B. The Select Ranger should only be fitted to flat surfaces. The Select Ranger can be fitted to the left or right of the switch or socket outlet. The Select Ranger is for FLUSH mounting only. Most domestic sockets and switches are flush mounted. Supplied already assembled for attachment to the right hand side of the switch/socket, it is easily converted for left hand use. To convert the module: 1 1. Remove the two screws in the back of the bracket. 2. Remove the module 2 from the bracket housing. 3. Turn bracket through 180 degrees so that the legs are pointing in the opposite direction. 4. Replace the module into the bracket 3 housing, inserting the two wires from the module through the hole in the bracket housing. 4 5. Replace the two retaining screws through the back of the bracket housing into the screw holes in the module and tighten. IMPORTANT When fitting the Select Ranger to a light switch it should be protected by an in-line fuse. However, as long as your premises are fitted with a fuse box or consumer unit, no additional fuse is required. 5 IMPORTANT - It is recommended that you program the timer before attaching the module to the switch/socket. See programming instructions. A LIGHT SWITCH Not Suitable for 2 Way Switches* When connecting to a two gang switch (2 switches on one plate) attach your Select Ranger to one switch only. 1. After switching off the mains, remove the two screws that hold the switch to the wall. 2. Pull the switch gently away from the wall. DO NOT REMOVE ANY WIRES. 3. Place the module and bracket housing over the open switch box. 4. Loosen screw to mains input (in the back of the switch) without removing any wires. 5. Insert the chosen module live wire into the input and tighten screw to secure. 6. Put the other module wire into the switch output. Follow steps 4 and 5 to complete the procedure. 7. Ensure all wires are secure in relevant ports. 8. Assemble the rest of the bracket (see below) and align with screw holes in the switch box. 9. A double-sided sticky pad is provided to secure the bracket to the wall. 10. Position the switch plate over the bracket aligning the screw holes. Using the extended screws provided, secure the whole assembly to the wall. 11. When the assembly is fully secure you can switch on the mains. 12. The Select Ranger is now ready for use. * A 2 Way switch is defined as being one of two light switches which operate the same light from different locations. LIGHT SWITCH ASSEMBLY 4

5 WARNING: DISCONNECT MAINS POWER PRIOR TO INSTALLATION B IMMERSION HEATER SWITCH (Ranger 2) For immersion heater follow instructions for 13 amp sockets. C 13 AMP SOCKETS Single/Twin/Switched/Unswitched NB. For the timer module to operate effectively on your 13 amp socket, it needs to be fitted differently to the module being attached to a light switch. 1. After switching off the mains, remove the two screws holding the socket front plate to the wall. 2. Pull the front plate gently away from the wall. DO NOT REMOVE ANY WIRES YET. 3. Place the module and bracket over the open socket. Identify the LIVE WIRE on the back of the socket and undo the screw holding it in place. 4. Using the connector provided join the LIVE WIRE to the chosen module live wire (see diagram below). Undo screws, place live wire in one end and module wire in the other and tighten screws. LIVE WIRE to socket 5. Insert the other module wire into the LIVE terminal on the back of the socket and tighten the screw. 6. Ensure that all wires are secure. 7. Assemble the rest of the bracket and align with the screw holes in the socket box. 8. Use the double-sided sticky pad provided to secure the bracket to the wall. 9. Position the socket front plate over the bracket aligning the screw holes. Using the extended screws provided secure the whole assembly to the wall. 10. Switch on the mains. 11. The Select Ranger is now ready for use. 12. For the socket to operate normally ensure that the DOUBLE SOCKET ASSEMBLY LIVE WIRE to Timer Module timer module is in the ON mode. SINGLE SOCKET ASSEMBLY 13. When wishing to put the timer programme into OPERATION mode and ensure that the timer module is in AUTO mode and leave the socket switch(es) in the ON position. D ANGLE BRACKET This bracket has been provided to give an improved viewing angle (particularly useful when attaching the module to low mounted sockets). To fit the angle bracket, remove the module from the main bracket (see page 4). Place the angle bracket over the main bracket, ensuring that the lips are fitted over the main bracket. Replace module as before (see page 4). E DIMMER SWITCH One Way only OPTION 1 - Fit as if to a normal light switch. When operating the light through your Select Ranger the light will come on at full intensity. The dimmer switch will operate normally. OPTION 2 - Fit as if to a socket. This will allow you to adjust the setting on the dimmer. NOTE: (Option 2 only) For the dimmer switch to operate normally the Select Ranger must be in the ON mode. To operate the lights with the timed programmes, the Select Ranger must be in the AUTO mode with the dimmer switch on and adjusted to the correct setting NB: NOT SUITABLE FOR FITTING TO SURFACE MOUNTED SWITCHES OR SOCKETS. Surface mounted refers to switches or sockets which are mounted on a pattress (base box) affixed to a wall. As with most industrial/commercial sockets. See diagram. FAULT FINDING 1. If the LCD fails to come on, check that the battery is fitted correctly. 2. If the module fails to operate the timer programme, check for low battery and replace if necessary. 3. If the LCD locks in one position, press the RESET button then follow the setting/programming instructions. IF YOU ARE IN DOUBT ABOUT ANY OF THESE FITTING INSTRUCTIONS, CONSULT A QUALIFIED ELECTRICIAN.