SKD U Electronic Valve Actuator

Similar documents
SKP Series SKP15U.. Gas Valve Actuator with Safety Shutoff Function

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

RC 195 Multiple Input Receiver-Controller

2- and 3-port valves with flanged connections, PN 10

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

POWERS Controls No. 4 Pneumatic Damper Actuator

WD-AMX Water Detection Controllers

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

HERZ-Thermal Actuators

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Radiant Temperature Sensor TY7321

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

IO-DIM6 6-Channel, Digital to Analogue Converters

! WARNING. Before using product, read and understand instructions.

TorqPlus TM Electric Valve Actuators and Controls

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Contractors Guide Central Inverter System Installation

Series 71, 72, and 76 Modutrol IV Motors

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

Quick running actuator

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

18SP653* EPA04 and EPA98 MBE 4000 High Pressure Fuel Line and Transfer Tube Installation

MP8000 Series Pneumatic Valve Actuators


Automatic Voltage Regulator User s Manual

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

POWERS CONTROL RC 195 Single Input Receiver-Controller

Inductive Proximity Sensors

Telefon (+45) Telefax (+45) Installation and operating manual

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection.

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

DUCT SMOKE DETECTOR D4120

Powers Controls TH 192 S Single Temperature Room Thermostat

Electric Rotary Actuator - On/Off or programmable control actuator

SIS. Fisher FIELDVUE DVC6200 Series Digital Valve Controllers. Contents. Before You Begin... 2

HMI display Installation Guide

EBS852 (Contrac) Power Electronic Unit

IO-RM3 3-Stage Relay Module

Valve and Valve Actuator Selection Guide

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Speed Control Relays SX2

ACS-30-EU-EMDR-10-MOD

Drayton Digistat +2RF/+3RF

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Duct Humidity Transmitter

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

TS93 EMR T/PT/TDE. Surface applied door closer

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Air damper actuators

Actuator for modulating control AME 435

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Butterfly Valves PN 6/10/16 for flanged connection

Total solder points: 57 Difficulty level: beginner advanced 3 TO 30VDC / 3A POWER SUPPLY K7203 ILLUSTRATED ASSEMBLY MANUAL H7203IP-1

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

TraceTek TTDM Series Leak Detection and Location Modules Replacement Parts Installation Instructions

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

650W Single Output Power Supply

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

T7560A,B,C Digital Wall Module

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Series 510 Submersible Level Transmitters

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Water Leak Detection System

SET1E. Installation & User Instructions. Electronic timeswitch for heating & hot water. Certification Mark

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Electronic Control Devices The European Product Catalogue 2007

Solid-State Timer H3G

SFS81 Series. Servo Finishing Stand PUSHCORP, INC. Dallas, Texas

PTO OWNER S MANUAL ALLISON FAMILY CODE. pag.1

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

FIRERAY 2000 Installation Guide

How To Drive A Compact Serie 1

CM705B - Universal Expander Module CM707B - Plug On Zone Expander Security Systems

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Tool Turrets and Tool Discs

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

PORTER MASS FLOW MEASUREMENT AND CONTROL SYSTEMS

Toroidal Conductivity Sensor

Modular I/O System Analog and Digital Interface Modules

CO2 Alarm. Operation. Application

Electronic Power Control

INSTALLATION MANUAL INSIDE ENGINE COMPARTMENT ZZT22#R (1ZZ-FE / 3ZZ-FE) / AZT220R (1AZ-FE) FOR EUROPEAN SPEC. AIR CONDITIONING ENGLISH.

Submersion/Insertion Toroidal Sensor

Transcription:

Document No. 29-27 April 22, 2 SKD U Electronic Valve Actuator Product Description The SKD U actuator requires a 24 Vac supply signal to control a Flowrite 599 Series valve with a /4-inch (2 mm) stroke. Product Numbers Non-Spring Return SKD6U SKD82.5U Spring Return SKD62U SKD82.5U Warning/Caution Notations WARNIN: CAUTION: Required Tools Personal injury or loss of life may occur if you do not follow a procedure as specified. Equipment damage or loss of data may occur if you do not follow a procedure as specified. 5 mm Allen wrench Small and medium flat-blade screwdrivers Expected Installation Time 2 minutes for factory installed actuator 45 minutes for field replacement of actuator Prerequisites WARNIN: If mounting the actuator to a valve already in line, either close the shut-off valves in the piping (upstream first, then downstream) or switch off the pump to allow the differential and static pressure in the valve to drop. Mounting Positions EA92R Not allowed with the Weather Shield Not allowed in any circumstance Figure. Acceptable Mounting Positions. Using the Weather Shield The SKD must be in the vertical position. Complete instructions for the mounting of the Weather Shield are included with that product. NOTE: Use the top knockout position when installing the Weather Shield. See Figure 6. EA857R VENTILATION OPENINS VENTILATION OPENINS Figure 2. Weather Shield Installation Position. Installation If you are mounting an actuator on a new valve, begin with the instructions in Figure. Item Number: 29-27-4, Rev. BA Page of 6

Document No. 29-27 April 22, 2 Removing the Actuator from the Valve. Remove the actuator cover. 2. Disconnect the wires and conduit, if installed.. Loosen the valve stem retainer using a 5 mm Allen wrench and lower the valve stem into the valve. 4. Loosen the yoke nuts using a 5 mm Allen wrench in the actuator yoke. 5. Remove the actuator from the valve, being careful not to damage the valve stem. Continue with Mounting an Actuator to a Valve. Figure 6. NOTE: Hold the stem retainer in place as you tighten it around the valve stem. See Figure 6. 5 Figure. Preparing a new Valve. EA8R2 5 mm 6 MAX. TORQUE 4 lb-in (4.5 Nm) 6 Mounting an Actuator to a Valve. Figure 7. NOTE: Install the packing heating element, (P/N 599-47), if used, before proceeding. NOTE: Position the actuator to accommodate the wiring. Hold the actuator in place while tightening the yoke nuts. See Figure 7. 7 Figure 4. 2 Figure 8. NOTE: Make sure the yoke nuts are loose enough to allow the actuator to slip over the bonnet. See Figure 5. 4 Page 2 of 6 Figure 5. Siemens Industry, Inc.

AC 24 V Document Number: 29-27 April 22, 2 Wiring B (SP) F CAUTION: Use care when removing the knockout. Do not damage the circuit board. B M B M N 2 Do not use autotransformers. Use earth ground isolating step-down Class 2 transformers. Determine supply transformer rating by summing total VA of all actuators used. The maximum rating for a Class 2 power supply circuit is VA. EA74R Y M Y M U Z Y (SN) B Sensor F Temperature Limiter N Controller Y Actuator Actuator Power Consumption Actuators Per Class 2 Supply Circuit* (8% of Transformer VA) SKD6 U 7 VA 4 SKD82.5U VA 8 SKD82.5U 8 VA 5 * Operating more actuators requires additional transformers or separate VA power supplies. Wiring Diagrams SKD6U/SKD62U Figures 9 and SKD82.5U/5U Figures through SKD6 U Figure. Connecting Terminals Y Z M U 24 Vac System Potential (SP) System Neutral (SN) Control Input: to Vdc or 4 to 2 ma (DIP switch selectable) Override Control (See Technical Instructions 55-8P25) Measuring Neutral Output for to Vdc or 4 to 2 ma measuring voltage. It will match the input signal type. Connection Terminals Calib. The position output signal U will switch from to Vdc to 4 to 2 ma when a 4 to 2 ma input signal is selected and used on the terminal Stroke Calibration Y M U Z AC 24V 5/6Hz... V 4... 2mA Chm Status Calib. Status reen Red OK Calib. Error Valve Jam LED Status Indication DIP Switches Functions See Below EA68R Wiring for SKD82 U Y 2 DIP Switches 2 Figure 9. SKD6 U. Selection of Control Signal 2 Selection of Flow Characteristic ON 4 to 2 ma Modified* OFF (Factory Setting) to Vdc Default EA94R2 Figure. Location of Terminals. *Changing the default setting will modify an equal percentage valve to a linear flow characteristic. When set to default, the flow characteristic is determined by the valve body. Siemens Industry, Inc. Page of 6

Document No. 29-27 April 22, 2 CONTROLLER NEUT Y 24 Vac EARTH ROUND ISOLATIN CLASS 2 TRANSFORMER FOR 24 Vac POWER EA745R CONTROLLER NEUT 2 Y 24 Vac EARTH ROUND ISOLATIN CLASS 2 TRANSFORMER FOR 24 Vac POWER 2 Vac EA746R 2 Vac 2 Y % % a b c % % EA448R2 Y % % Cm c 4 5 c2 4 5 ASC9.DU a b c ASZ7. % % Figure 2. Non-Spring Return SKD82.5U. Connecting Terminals System Potential 24 Vac (+) Y Outward movement of coupling piece ( to ) Inward movement of coupling piece ( to ) Cm Limit switch for % stroke c ASC9.DU double auxiliary switch c2 ASC9.DU double auxiliary switch Ω ASZ7. potentiometer The diagram shows all possible connections. How many and which are used depend on the application. EA447R2 N.O. Cm c c2 4 5 4 5 ASC9.DU ASZ7. Figure. Spring Return SKD82.5U. Connecting Terminals System Potential 24 Vac (+) 2 System Neutral (SN) Y Outward movement of coupling piece ( to ) Inward movement of coupling piece ( to ) Cm Limit switch for % stroke c ASC9.DU double auxiliary switch c2 ASC9.DU double auxiliary switch Ω ASZ7. potentiometer The diagram shows all possible connections. How many and which are used depend on the application. Start-Up Check the wiring for proper connections. Consult Technical Instructions 55-8P25 for detailed commissioning information. Normally Closed Valve Actuator pressure cylinder moves: Outward ( to ): Valve opens. Inward ( to ): Valve closes. Normally Open Valve Actuator pressure cylinder moves: Outward ( to ): Valve closes. Inward ( to ): Valve opens. Three-Way Valve Actuator pressure cylinder moves: Outward: Valve opens between port NC and C. Inward: Valve opens between ports NO and C. Page 4 of 6 NOTE: The valve body assembly determines the complete assembly action. Siemens Industry, Inc.

Document Number: 29-27 April 22, 2 Manual Operation >x6 << AUTO >> Dimensions -/4 (285) EA8R << MAN >> << AUTO >> Figure 4. Manual Override in Manual and Automatic Position. Each complete revolution (6 ) is equal to /2-inch (2.5 mm) stroke. 8-/6 (224) Reference Technical Instruction Document Number 4-/6 (22) 4-/6 (22) 2-9/6 (65) Flowrite EA599 Series SKD Electronic Valve Actuator Proportional Control 55-8P25 Flowrite EA599 Series SKD Electronic Valve Actuator -position(floating) Control 55-8P25 2-7/8 (27) 9-/8 (22) 4-/2 (4) /4 (9) -5/6 (49) EA854R 5 (26) Figure 6. Dimensions of the 599-7 Weather Shield in inches (mm). Figure 5. Valve Stem Travel Indication. Siemens Industry, Inc. Page 5 of 6

Document No. 29-27 April 22, 2 Dimensions, Continued CAUTION: Be careful when removing the knockout. Do not damage the circuit board. NOTE: Use the top knockout position when installing the Weather Shield. SERVICE ENVELOPE MINIMUM ACCESS SPACE RECOMMENDED 4 inch ( mm) 8 inch (2 mm) Figure 7. SKD U Dimensions in Inches (mm). Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Flowrite is a trademark of Siemens Industry, Inc. Other product or company names mentioned herein may be the trademarks of their respective owners. 2 Siemens Industry, Inc. Siemens Industry, Inc. Building Technologies Division Deerfield Parkway Buffalo rove, IL 689-45 USA Tel. + 847-25- Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com Document No. 29-27 Printed in the USA Page 6 of 6