Flow Cytometry. Powerful Versatile Performance

Similar documents
Application Information Bulletin: Set-Up of the CytoFLEX Set-Up of the CytoFLEX* for Extracellular Vesicle Measurement

Boundary-breaking acoustic focusing cytometry

APPLICATION INFORMATION

COMPENSATION MIT Flow Cytometry Core Facility

Cell Discovery 360: Explore more possibilities.

Katharina Lückerath (AG Dr. Martin Zörnig) adapted from Dr. Jörg Hildmann BD Biosciences,Customer Service

BD FACSComp Software Tutorial

CyAn : 11 Parameter Desktop Flow Cytometer

123count ebeads Catalog Number: Also known as: Absolute cell count beads GPR: General Purpose Reagents. For Laboratory Use.

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

Using the BD TM Cytometer Setup and Tracking (CS&T) System for Instrument Characterization and Performance Tracking

CyFlow SL. Healthcare Immunology. Portable FCM System for 3-colour Immunophenotyping

Application Note. Selecting Reagents for Multicolor Flow Cytometry. Holden Maecker and Joe Trotter BD Biosciences, San Jose

Technical Bulletin. An Introduction to Compensation for Multicolor Assays on Digital Flow Cytometers

Introduction to Flow Cytometry

Zecotek S Light Projection Network Marketing

Cytell Cell Imaging System

Introduction to flow cytometry

Multicolor Flow Cytometry: Setup and Optimization on the BD Accuri C6 Flow Cytometer

Spherotech, Inc Irma Lee Circle, Unit 101, Lake Forest, Illinois

No-wash, no-lyse detection of leukocytes in human whole blood on the Attune NxT Flow Cytometer

Instructions for Use. CyAn ADP. High-speed Analyzer. Summit G June Beckman Coulter, Inc N. Harbor Blvd. Fullerton, CA 92835

Instrument Characterization and Performance Tracking for Digital Flow Cytometers

FCAP Array v3.0 Software: A New Tool to Analyze BD Cytometric Bead Array (CBA) Data. Monisha Sundarrajan, PhD BD Biosciences

Using BD FACSDiva CST To. Evaluate Cytometer Performance, Create Custom Assay Settings. and

1. Instrument Layout pg Summit Overview pg Data Storage and Data Files pgs Saving Data pg Start Up pg 8

CyFlow SL. Microbiology. Detection and Analysis of Microorganisms and Small Particles

Immunophenotyping peripheral blood cells

Standardization, Calibration and Quality Control

Flow Cytometry for Everyone Else Susan McQuiston, J.D., MLS(ASCP), C.Cy.

Multicolor Bead Flow Cytometry Standardization Heba Degheidy MD, PhD, QCYM DB/OSEL/CDRH/FDA Manager of MCM Flow Cytometry Facility

Using CyTOF Data with FlowJo Version Revised 2/3/14

NyONE - Cell imaging in a bird s eye view 4. NyONE...resolution matters! 8. Features & benefits 10. Fluorescence excitation channels 12

LOAD & GO and make flow cytometry simplicity itself. the full spectrum of Flow Cytometry

INSIDE THE BLACK BOX

Instructions for Use. Kaluza. Flow Cytometry Analysis Software. A75667AA September Beckman Coulter, Inc. 250 South Kraemer Blvd.

Science is hard. Flow cytometry should be easy.

Technical Bulletin. Threshold and Analysis of Small Particles on the BD Accuri C6 Flow Cytometer

Three Rules for Compensation Controls

Zeiss 780 Training Notes

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

powerful. Intuitive. Customizable. The new star of benchtop flow cytometry

These particles have something in common

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs

FlowSight. Flow cytometry with vision

Flow Cytometry A Basic Overview

CyTOF2. Mass cytometry system. Unveil new cell types and function with high-parameter protein detection

Below is a list of things you should be aware of before you schedule your sort.

--Verity Software House, ModFit for Proliferation offers online tutorials

Cell Cycle Phase Determination Kit

MEASURABLE PARAMETERS: Flow cytometers are capable of measuring a variety of cellular characteristics such as:

Supplementary Material. Free-radical production after post-thaw incubation of ram spermatozoa is related to decreased in vivo fertility

Technical Bulletin. Standardizing Application Setup Across Multiple Flow Cytometers Using BD FACSDiva Version 6 Software. Abstract

BD LSR II and FACSDiVa Software. Dr. Jens Fleischer, Basel Dr. Norbert Leclere,, Berlin

Attune NxT Acoustic Focusing Cytometer

Principles of Flowcytometry

CyFlow Space Your flexible flow cytometer

CELL CYCLE BASICS. G0/1 = 1X S Phase G2/M = 2X DYE FLUORESCENCE

a Beckman Coulter Life Sciences: White Paper

BD FACSDiva TUTORIAL TSRI FLOW CYTOMETRY CORE FACILITY

LAB FORWARD. WITH PROService REMOTE SERVICE APPLICATION. Frequently Asked Questions

Introduction to Flow Cytometry -- BD LSR II. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size

UV-Vis spectrophotometers

Automated Quadratic Characterization of Flow Cytometer Instrument Sensitivity (flowqb Package: Introductory Processing Using Data NIH))

Cell Cycle Tutorial. Contents

Products - Microarray Scanners - SpotLight Two-Color Microarray Fluorescence Scanners New! SpotLight 2 now available!

Flow Cytometry. What is Flow Cytometry? What Can a Flow Cytometer Tell Us About a Cell? Particle Size. Flow = Fluid Cyto = Cell Metry = Measurement

MultiQuant Software 2.0 for Targeted Protein / Peptide Quantification

Beckman Coulter DTX 880 Multimode Detector Bergen County Technical Schools Stem Cell Lab

Simplicity. Reliability. Performance

Practical Cell Analysis

BD FC Beads 8-Color Kit for BD OneFlow Assays

Flow Data Analysis. Qianjun Zhang Application Scientist, Tree Star Inc. Oregon, USA FLOWJO CYTOMETRY DATA ANALYSIS SOFTWARE

Fiber Optic Distributed Temperature Sensor (B-DTS)

use. 3,5 Apoptosis Viability Titration Assays

ab Propidium Iodide Flow Cytometry Kit for Cell Cycle Analysis

Introduction to Flow Cytometry

Calibration Control. Calibration Management Software. Tools for Management Systems

The SickKids-UHN Flow Cytometry Facility at TMDT Instructions for Online Scheduling User Version 1.0

SmartFlare RNA Detection Probes: Principles, protocols and troubleshooting

Features Rich Detectors for Every Laboratory and Application

ArC Amine Reactive Compensation Bead Kit

Flow Cytometry. flow cytometer DNA apoptosis ph

Uses of Flow Cytometry

Navios Quick Reference

How to operate the BD FACSCanto flow cytometer

PROTOCOL. Immunostaining for Flow Cytometry. Background. Materials and equipment required.

Attune Acoustic Focusing Cytometer

Stepcount. Product Description: Closed transparent tubes with a metal screen, including a white matrix at the bottom. Cat. Reference: STP-25T

BD CellQuest Pro Software Analysis Tutorial

Experiment 5. Lasers and laser mode structure

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module

DIRECTIONAL FIBER OPTIC POWER MONITORS (TAPS/PHOTODIODES)

Imaging and Bioinformatics Software

Free 15-day trial. Signata Waveform Viewer Datasheet

Measuring Laser Power and Energy Output

LIVE/DEAD Fixable Dead Cell Stain Kits

BD FACSVerse. Simply brilliant

UCHC Guide to FACS DiVa. LSR II instruments

Hoechst HSC Staining and Stem Cell Purification Protocol (see Goodell, M., et al. (1996) J Exp Med 183, )

Transcription:

Flow Cytometry Powerful Versatile Performance

Gallios Flow Cytometer Speed, reproducibility, simplicity, reliability These are the goals that every flow cytometry lab aims to achieve. Beckman Coulter shows the way with the Gallios Flow Cytometer, a state-of-the-art system designed with your research needs in mind. Gallios delivers consistent and reliable analysis of multi-color assays.

Speed Reproducibility Simplicity Reliability With up to four lasers, ten colors Gallios delivers powerful, consistent A multi-sample loading system is The optional PROService Remote and advanced optical design, Gallios performance and data integrity designed with busy research labs Diagnostic System helps keep delivers high resolution in a short in the most complex analytical in mind, and educational support Gallios operating at peak perfor- amount of time, with accurate pro- environments. Acquire quality data enhances ease and convenience mance, with minimal downtime. cessing of your flow cytometry data. efficiently and accurately, and get for users. Troubleshoot and resolve any stable performance over long peri- issues promptly and efficiently and, ods of time and across a wide range in some cases, identify potential of operating temperatures. issues that could affect your laboratory productivity. Enjoy sophisticated technology and flexible options with Gallios Flow Cytometer Gallios delivers excellent resolution Built on a platform designed with reliability and stability in mind, Gallios samples information at 40MHz and displays data on a 1,048,576 channel scale. These specifications offer resolution of cell/particle characterization without sacrificing analytical speed or data integrity. An innovative forward-scatter detector enables excellent resolution of submicron particles down to 0.404 μm in diameter. A side-scatter detector incorporates an independently focused, high-performance photodiode with electronic attenuation. Six fluorescence detectors provide simultaneous acquisition of up to six fluorescence signals. The electronics provide accurate and efficient signal processing at high event rates. A selection of up to 62 parameters can be processed per analysis at acquisition rates of 25,000 events per seconds with high yield. Gallios delivers a stable performance over long periods of time and across a wide range of operating temperatures. Whether your challenges are dim markers, rare events, or just routine analysis, the Gallios is the cytometer of choice to capture all of your events collecting four times the information as the cell passes through the interrogation point and displaying the information on a scale with four times the resolution.

Panel A Panel B Panel C E. coli E. coli E. coli FL1 (525/30) Panel D FL2 (582/15) FL2 (582/15) Panel E E. coli Mouse spleen FL2 (582/15) FoxP3-mRFP Fluorescent protein detection with 488 and 561 nm excitation. Escherichia coli transfected with mcherry, dsred, mkate and dtomato could be resolved in FL1, FL2, and FL3 (panels A-D). Mouse spleen cells transfected with FoxP3-mRFP (blue) are shown in panel E. FL2 (582/15) Gallios delivers flexibility to expand your research Gallios makes it easy to detect fluorescent proteins with the optional 561nm Laser When you incorporate the optional 405nm violet laser and an optional 561nm yellow laser, you get a greater choice of fluorochromes to perform complex multicolor experiments. Easily interchangeable optical filters facilitate detection of Gallios is now equipped for an optional 561nm laser to allow for expanded applications and greater choice of fluorochromes for multicolor experiments. With the new 561nm laser system you can analyze multiple fluorescent proteins simultaneously, as well as benefit from a greater ability to detect red fluorescent proteins. a variety of dyes and wavelengths. You can also add up to four additional fluorescence detectors, enabling you to read up to 10 colors concurrently. Analyze red fluorescent proteins such as mcherry and DsRed. Take full advantage of improved PE tandem dyes for enhanced detection. Versatile for both phenotypic and functional analysis using fluorescent antibodies, dyes and proteins.

State-Of-The Art Optics The Gallios Flow Cytometer is in a class by itself with its advanced optical design that provides efficient acquisition of superior quality data. The Gallios is built with two highly stable, solid-state lasers in standard red and blue. You can choose the option to add up to four lasers by opting for violet and yellow lasers. Easily interchangeable optical filters facilitate detection of a variety of dyes and wavelengths. An innovative forward-scatter detector enables superior resolution of submicron particles down to 0.404 µm in diameter. A side-scatter detector incorporates an independently focused, high-performance photodiode with electronic attenuation. Six fluorescence detectors provide simultaneous acquisition of up to six fluorescence signals. Gallios is available in 2, 3 and 4 laser configurations: 6 color, 2 laser (488nm Blue & 638nm Red) (5 + 1) 8 color, 2 laser (488nm Blue & 638nm Red) (5 + 3) 10 color, 3 laser (488nm Blue, 638nm Red & 405nm Violet) (5 + 3 + 2) 10 color, 4 laser (488nm Blue & 561nm Yellow [co-linear], 638nm Red, 405nm Violet) (5 + 3 + 2) * The optional 561nm yellow laser is co-linear with the blue 488nm laser

Radar Plot To enable multi-parametric pattern visualization without gating Logicle Display Adjustable linear/log transition Slider bars to adjust compensation Elevate your data analysis with Kaluza Flow Cytometry Analysis Software Today, more colors require more plots, events, protocol complexity and ultimately increased analysis time. Kaluza is cutting edge flow cytometry software that performs powerful real-time data analysis of complex multi-color files. Its revolutionary speed (analyzing millions of cells, not thousands) makes analysis of multiple data sets as simple as drag and drop. Kaluza helps you simplify the management of multiple data sets, enables visualization of high-content data in different spatial dimensions on a single plot, and provides real-time analysis of high-content flow cytometry files. The software features automatic plot organization, a zoom in/out feature to enhance data exploration, and auto-layout, which reconfigures the workspace in order to reduce the process of maintaining an analysis. Kaluza features a variety of innovative plot types, including tree, 3D radar and overlay histogram as well as standard scatter, histogram and contour plots. Kaluza works with the majority of FCS-compliant files, can operate on either network or stand-alone computers and is supercomputer compatible with the NVIDIA Tesla graphics card. Download a free 30-day trial version of Kaluza Analysis Software at: www.kaluzanow.com

Fast, accurate, efficient digital electronics, extraordinary sensitivity and resolution; spatially separated solid state lasers with up to 10 colors give flexibility, accuracy and quality. Maintain peak performance with PROService Remote Diagnostics Not only do we care about designing and manufacturing quality instrumentation, we also want to ensure that your Gallios Flow Cytometer maintains peak performance. To that end, we created PROService, a remote diagnostic system that enhances the technical support of your flow cytometer. PROService delivers prompt, efficient troubleshooting and issue resolution, minimizing downtime. In certain circumstances, PROService can preemptively identify potential problems and correct them before they impact your laboratory productivity. Count on Beckman Coulter to provide you with 24-7 support from our expert field consultants.

Gallios Flow Cytometer Make the most of your flow cytometry capabilities with the powerful versatile performance of Gallios. Contact your Beckman Coulter representative or visit us at: www.galliosnow.com Download a free 30-day trial version of Kaluza Analysis Software at: www.kaluzanow.com Gallios and Kaluza are for research use only. Not for use in diagnostics procedures. Gallios, Kaluza and Beckman Coulter and the stylized logo are trademarks of Beckman Coulter, Inc. and are registered with the USPTO. NVIDIA is a registered trademark of NVIDIA Corporation. BR-17146C B2012-13567 2013 Beckman Coulter, Inc.