Change the Way You Spray to Minimize Clogging



Similar documents
How to Pre-empt a Significant Profit Drain: Nozzle Wear

Optimizing Tank Cleaning Operations

Optimizing Your Spray System

Cooking at the Speed of light!

Removing Solids with Automatic Self-Cleaning Filters

Signature and ISX CM870 Fuel System

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

Amiad s AMF² pre-treatment technology ensures efficient and reliable nanofiltration of Scottish Highland loch water

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

How To Clean Up A Reactor Water Cleanup

SEMI-AUTOMATIC Filters. Quick and efficient way for cleaning manual filters

Trouble Shooting. Pump

Oil and Coolant Circulating Heating System. Model - OCSM

Stanadyne Fuel Manager Diesel Fuel Filter/Water Separator System. User s Guide

Water Treatment and Reverse Osmosis Systems

A Guide to Trouble-Free Cooling Towers

HOW TO GET TANKS & TOTES CLEANER IN LESS TIME & LOWER COSTS

Strong partners offer perfect solutions. Automatic filtration and maintenance of engine lubricating oil in diesel locomotives

Automatic Back-Flushing Filter AutoFilt RF9.

Filtration Guide. Introduction. Benefits of Clean Water

Automatic Self-Cleaning Strainers

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Optimizing In-Tank Agitation and Mixing Using Eductors

Description & Working

Electronic Flow Switches

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Spray Nozzles. Spray Control. Spray Fabrication. Spray Analysis. A Guide to Parts and Equipment Washing, Rinsing and Drying Using Spray Technology

Matching the Right Hot Melt Adhesive System to Your Case/Carton Sealing and Tray Forming Operations. Published by: Nordson Corporation

Automatic filters for fuel and lubricating oil. Technical information for oil filtration

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

CITY OF GOLDEN DEPARTMENT OF PUBLIC WORKS, ENVIRONMENTAL SERVICES DIVISION

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Routine and Emergency Boiler Operation

Cost Savings Gained through Rotary Impingement Tank Cleaning

Approval of this procedure is provided by signatory indicated in the approval block at the footer of Page #1, for and on behalf of Jabiru Pty. Ltd.

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat


Diesel Fuel Systems. Injection Nozzles

Spray gun Maintenance and Troubleshooting Guide (JGA)

Section 11 - System Diagrams

Flushing and Cleaning the A/C System

SEPAR FILTER SEPAR 2000 SEPAR 2000

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

FRL/AirCare Air Controls & Accessories

M A N U A L

Section 6 - System Diagrams

CHEMICAL CLEANING UNIT Product number:

Drainage and Grease Management for the Commercial Kitchen

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

Hydraulic Troubleshooting PRESENTED BY

DESIGN STANDARDS SECTION

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Action Plan Template HVAC Page 1

Reliability. The Essentials of Eliminating Downtime of your Electric Motor. Asset Management? Or, Maintenance Management, Re-branded?

TECHNICAL DATA. Dry 122a. November 12, 2013

Take the complication out of cooling. Data center cooling equipment and service from Alfa Laval

74 Chapter CO 2 Cleaning

Standard Hydraulic Piping Flushing Procedure

FLASH TANK ECONOMIZER PRODUCT GUIDE

Septic System Owner s Manual

HIGH PERFORMANCE FILTERS AND ELEMENTS

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

World-Class Oil Sampling It is Possible

Instruction Manual. Ultrasonic Cleaning Tank. Advanced Ceramics Technology (M) Sdn. Bhd A Crest Group Inc. Company

Heating Water by Direct Steam Injection

UNITOR VACUUM cleaners

CTV-1500 Cooling Tower Vacuum Operating & Maintenance Manual

PLUMBING & CROSS-CONNECTION CONTROL

The ACCU-LUBE Micro-Lubricating System for external and internal lubrication

All Products Brochure

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

Boiler and Burner Cleaning and Servicing Specifications

1.2 Refrigerant Equipment. General

Chapter 19 - Common Rail High Pressure Fuel Injection Systems

Instruction manual of pumps WQ, WQF, SN, Furiatka, Furia, KRAKEN, BIG, IP, IPE, SWQ, CTR

How To Make A Fuel Manager Filter/Separator

Steam Sterilization Cycles for Lab Applications

AIR CONDITIONER GENERAL 1. SPECIFICATIONS AIR CONDITIONER REXTON

Sewer Jetter GuideSM. How to Unclog Drains with Your Pressure Washer. Use this Guide To:

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

Attachment J-C18.1. HVAC Work Instructions

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Table Z. Troubleshooting Chart for Air Conditioners. Cause

VOYAGER 570G. 744A Sprayer Control

Lapping and Polishing Basics

Medical Air Systems: Scroll

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

CENTRIFUGAL DRYERS JUNE 2013 GALA INDUSTRIES, INC.

SunMaxx Solar Filling Station Operating Instructions

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Maintenance and Cleaning Tips MULTICO

Increasing Productivity and Reducing Costs with CIP Optimization

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

PulseJetter Drain Cleaner

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Transcription:

Nozzles Control Analysis Fabrication Change the Way You to Minimize Clogging By Jon Barber, ing Systems Co. nozzles appear to be simple devices, but in service they function as highly precise instruments. A spray system that is not working optimally can very quickly cost your operation tens even hundreds of thousands of dollars annually. When nozzles become partially blocked, spraying efficiency is degraded and your process can be compromised. The most frequent cause of clogging is the presence of contaminants in process water a condition that is particularly common in systems that use recirculated water. Other factors that may cause clogging are particle agglomeration, scaling and bearding the build-up of material on the inside and outer edges of the orifice. The negative effects of clogging on spray performance include decreased flow and disturbed spray patterns as illustrated in Figure 1. When positive displacement pumps are in use, clogged spray nozzles will increase process pressure, whereas flow will be most acutely affected when centrifugal pumps are used. Contaminants Obstructed Flow FIGURE 1. Contaminants in the spray solution obstruct flow and spray pattern distortion is a typical result. Clogging can cause significant dollar-robbing complications: Quality problems increased scrap or process problems If the spray application directly affects product quality, increased scrap is the inevitable result of nozzle clogging. This can happen when coatings, release agents, lubricants or protective films are applied unevenly or with inconsistent coating thickness on the finished product. If the spray is part of an intermediate cooling, cleaning, humidifying or moistening process, the specified performance will be compromised. Cross-batch contamination can also occur when spray patterns deteriorate and uneven cleaning results. Depending on your process, potential losses can easily reach tens of thousands of dollars in wasted product before a clogging problem is noticed and corrective action is initiated. Production downtime and additional maintenance cost Process interventions due to clogged spray systems are of three kinds: monitoring, maintenance and downtime. Systems that are plagued by clogged nozzles generally require close observation and documentation that performance continues to be on spec. When this labor-intensive process reveals a problem, maintenance is required and often results in downtime the most expensive intervention of the three. For example: A plant running 24 hours per day, 5 days per week and 52 weeks per year at $15 per hour for labor and $100 per hour for downtime. 1 hour per shift spent monitoring/maintaining the system $11,700 2 hours per week system is down for maintenance $13,250 Potential Annual Cost of Clogging $25,220 Figures in USD.

Change the Way You to Minimize Clogging Simple Solutions that Work for Many Systems Minimizing clogging Proactive maintenance is the best way to prevent clogging problems from occurring but even well-maintained systems can experience problems from time to time. Many spray systems can be efficiently maintained in good operating condition by manually cleaning nozzles at regular intervals. But a word of caution only use materials that are much softer than the nozzle orifice surface. Plastic bristle brushes and wooden or plastic probes are good. Never use tools such as wire brushes or pocket knives. It is very easy to damage the critical orifice shape and/or size and produce distorted spray patterns or excess flow. When nozzles become clogged and manual cleaning with a non-damaging instrument doesn t solve the problem, try soaking the orifice in a non-corrosive cleaning chemical to soften or dissolve the clogging substance. Clean nozzles with a material that is softer than the orifice, like a toothbrush or toothpick. Add strainers Most applications can benefit from adding strainers, which are an easy and economical way to minimize clogging. Strainers, including spray nozzles with built-in strainers, trap larger particles and prevent debris from entering the spray nozzle orifice or vane. Popular and effective strainer types include: Integral strainers can often be ordered as part of the nozzle itself and are available in a variety of mesh sizes, down to 200 mesh, and materials including brass, aluminum, nylon, stainless steel and polypropylene, for standard and quick-connect flat spray, full cone, hollow cone and fine spray nozzles. Integral strainers keep debris from entering nozzle. T-strainers are widely used and available in many configurations. Most are designed to minimize pressure drop and provide simple, fast cleaning and maintenance. See Figure 2. Self-cleaning versions, which allow the filtered liquid to pass through the strainer and liquid particles to be returned to the liquid supply, are another option. Strainers are available in a wide variety of materials including FDA-compliant materials for potable water usage for low-, medium- and high-pressure applications. Figure 2. Inlet Connection Bowl T-strainers feature a removable bottom plug for complete withdrawal of the screen assembly during cleaning. On some models the bottom pipe plug can be replaced with a drain cock for quick-flush cleaning. Integral Mounting Provision Strainer Basket Drain Cock Outlet Connection

Change the Way You to Minimize Clogging More Sophisticated Solutions for More Demanding Applications Self-cleaning strainers Self-cleaning strainers offer a unique answer to effective filtration and clog prevention for process water, cooling tower, pre-filtration to water treatment and similar applications. These strainers consist of a series of automatic filters with a self-cleaning mechanism driven by an electric motor. A pre-screen protects the cleaning mechanism from large particles, after which the main screen removes debris down to 10 micron particle size. As debris accumulates on the main screen, it creates a filter cake which causes a pressure differential across the screen, triggering the cleaning process when it reaches a pre-set value. One version uses a suction scanner that rotates in a spiral motion while vacuuming the filter cake from the screen and expelling it through the exhaust valve. See Figure 3. Suction scanning is equally as effective at filtering two-dimensional scale and three-dimensional sand. Particle adhesive characteristics have no significant impact on the efficiency of this process, making it well-suited for greasy or oily water. Figure 3. The suction scanner is a hollow stainless steel pipe with tubular nozzles evenly spaced along its length. The spiraling motion of the nozzles cleans 100% of the strainer screen. Maximum Free Passage (MFP) nozzle designs MFP nozzle designs are another effective answer to clogging. These nozzles feature open flow passages to ensure that most contaminants can pass through. MFP nozzles are an excellent choice for applications requiring maximum liquid throughput such as aerating, dust control, chemical processing, food processing, pulp and paper, gas scrubbing/cooling and fire suppression/prevention or anytime there is debris in the water or where recirculated liquid is being used. However, be sure to research MFP claims as there can be a big difference in the performance of these nozzles. One simple test is to drop a ball bearing of the free passage diameter size through the nozzle. It should pass through freely. Another attribute to evaluate is spray pattern. Some MFP nozzles don t provide the promised spray pattern. Watch for very thick edges and light centers in full cone nozzles and heavy centers in hollow cone patterns. See Figure 4A and 4B. Good MFP full cone spray pattern Poor MFP full cone spray pattern Figure 4. Comparison of spray patterns on two brands of maximum free passage full cone nozzles.

Change the Way You to Minimize Clogging More Sophisticated Solutions for More Demanding Applications Continued Self-cleaning nozzles Self-cleaning nozzles are available in a number of configurations and operating styles. For example, nozzles with clean-out needles are ideal for intermittent spraying applications using liquid that can dry in the orifice between uses. The clean-out needle can be activated manually or automatically, depending on nozzle type, and slides through the liquid orifice to clear obstructions. Automatic spray nozzles can be equipped with a clean-out needle that cleans the liquid orifice after each spray cycle for maximum protection against clogging. Other self-cleaning nozzles retract a purge piston when line pressure is reduced to remove fibers and other solids from a clogged nozzle. headers, with internal brushes that rotate and remove debris from nozzle orifices, are also widely used in applications where less than pristine water is used. Heated spray nozzles and systems The addition of a fluid-filled heat jacket or electric band heater can ensure trouble-free atomization of hard-to-spray liquids such as waxes, adhesives, starches and syrups and further minimizes maintenance due to clogging. When spraying an extremely difficult solution such as chocolate, an automated system may be required. Heated automated systems use closed-loop temperature control to ensure liquid temperature is ensured all the way from the tank to the target. The pressure tank, liquid and air lines are usually jacketed or heated to ensure consistent flow rates and clog-free operation. Clean-out needles remove debris from nozzle orifices. nozzle heat jacket Anti-bearding spray set-ups Anti-bearding spray set-ups reduce bearding and clogging by changing the air current around the spray tip to prevent drops from falling back onto the nozzle and causing build-up. In some cases, users can run their spray operations up to 20-times longer without shutting down. Pulse Width Modulated (PWM) flow control When used with a spray controller, some electrically actuated spray nozzles can utilize pulse width modulation (PWM) to reduce clogging. By cycling the nozzles on and off up to 10,000 times per minute, low flow rates can be achieved using larger, clog-resistant spray tips that reduce maintenance downtime. For example, at a duty cycle of 50%, the nozzle sprays half the time and the flow will be 50% of the maximum flow rate at a given pressure for the nozzle. ON OFF Anti-bearding nozzle 1 Cycle 1 Cycle 1 Cycle When used with a dedicated spray controller, automatic spray nozzles can utilize PWM flow control to reduce clogging.

Change the Way You to Minimize Clogging More Sophisticated Solutions for More Demanding Applications Continued Automated spray systems In many automated spray systems, the spray controller can automatically adjust spray performance to compensate for changes in operating conditions. This minimizes clogging in many applications. However when spray nozzles do clog, it is detected immediately and operators are notified to minimize scrap and lost production time. For quality control, a miniature sensor mounted near the orifice of a nozzle can optically detect a spray pattern emerging from the spray tip and send a spray present signal to the controller. Unconfirmed spray cycles often the result of clogging can activate alarms or stop production. Each spray cycle can be documented and logged by the spray controller. In other types of automated operations where a dedicated spray controller is not used, such as tank washing, monitoring devices can be added for clog detection and performance validation. Acoustic monitors, for example, can be used with all types of tanks and tank cleaning nozzles to listen for the normal sounds of tank cleaning. Mounted outside the tank, they detect weak sound waves that indicate a change in spray pressure and clogged or partially clogged nozzles. Nozzle with sensor in automated systems can provide instant detection of clogs. Modular automated spray systems help minimize clogging by making adjustments to compensate for changes in operating conditions. In addition to clog prevention and detection, automated spray systems offer many benefits: Accurately detect nozzle wear Monitor flow and other performance criteria with automatic shutdown for selected faults Adjust flow rates and spray patterns for variable speed conveyors and varied product shapes Control temperature to ensure even application of viscous coatings Verify spray cycles in critical applications Tank washing monitoring system uses an acoustic sensor to detect clogging and other conditions. System Optimization In this paper we ve discussed the problem of nozzle clogging and various remedies in detail. But, just because a nozzle is clog-free and spraying doesn t mean that your spray system performance is optimal since there are many other factors that can affect system effectiveness. To achieve long-term, efficient, optimal performance, consider your spray system in its entirety and develop a plan for evaluating, monitoring and maintaining it. If you don t already have a comprehensive System Optimization Program in place, contact the manufacturer of your spray nozzles for more information.

Change the Way You to Minimize Clogging About ing Systems Co. ing Systems Co. is the leader in spray technology with the most extensive product line, global manufacturing and sales offices in more than 85 countries. nozzles, turnkey spray systems, custom fabrication and research/testing services comprise the company s offering. Jon Barber is a Director at ing Systems Co. in Wheaton, Illinois. He can be reached via e-mail at jon.barber@spray.com. Nozzles Control Analysis Fabrication P.O. Box 7900, Wheaton, IL 60189-7900 USA Tel: 1.800.95.SPRAY Intl. Tel: 1.630.665.5000 Fax: 1.888.95.SPRAY Intl. Fax: 1.630.260.0842 www.spray.com WP100 ing Systems Co. 2008