Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

EMC TEST REPORT For. Webcam. Model Number: CAM67U

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

Electromagnetic Compatibility Test Report Test results of Floww equipment

TEST REPORT EN (1997) +A1 (2001)

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

Declaration of Conformity.

Test Report #: Date: April 8, 2005

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

CE MARK TECHNICAL FILE

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

Design and Certification of ASH Radio Systems for Japan

Declaration of Conformity.

EMC Test for Compliance with EU EMC Directive 2004/108/EU

RAPPORTO DI PROVA / TEST REPORT

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Waveguide Access Point WGA631. Product Guide

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

Current Probes. User Manual

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

Energy Management Energy Meter Type EM23 DIN

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

30 In Compliance October

Telephone- and leased line modem for industrial applications TD-36

AMIS. Automated Metering and Information System. Integration of meters from other manufacturers

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

R&S ZNC Vector Network Analyzer Specifications

Report Of. Shielding Effectiveness Test For. SafeSleeve Radiation Shielding Technology. Test Date(s): June 07 June 09, 2015

Rack mounted telephone- and leased line modem for industrial applications

Agilent E5100A Network Analyzer

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

R&S ZNBT8 Vector Network Analyzer Specifications

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

Drayton Digistat +2RF/+3RF

Application Note: Spread Spectrum Oscillators Reduce EMI for High Speed Digital Systems

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

CE MARK TECHNICAL FILE

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

The impact of the New EMC Directive 2004/108/EC

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions

Fluke 3000 FC Series Test Tools Technical Data

Automotive Electronics Council Component Technical Committee

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

EMC Basics. Speaker : Alain Lafuente. Alain.lafuente@we-online.com

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

RX-AM4SF Receiver. Pin-out. Connections

Uncertainty evaluations in EMC measurements

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

CE Test Report. : Microchip Technology Inc West Chandler Blvd., Chandler, Arizona , USA

Dual Chamber Temporary External Pacemaker

EMI TEST REPORT. Product Name. Notebook Personal Computer. Model A770;A790. Applied by:

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Draft ETSI EN V1.2.1 ( )

AC3200 INTELLIGENT BROADBAND AMPLIFIER

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Amplifier for Small Magnetic and Electric Wideband Receiving Antennas (model AAA-1B)

CE-EMC TEST- REPORT TEST REPORT NUMBER: EFSN E-E01 EUROFINS TESTING TECHNOLOGY (SHENZHEN) CO., LTD.

AN Surging Ideas TVS Diode Application Note PROTECTION PRODUCTS. TRANSIENT IMMUNITY STANDARDS: IEC x

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

How To Use A Sound Card With A Subsonic Sound Card

Installation and Operation Back-UPS 1250, 1300, 1500

NI USB-5681 RF Power Meter Specifications

Transcription:

Product Name Model(s) Brand Responsible Party Address Issue Date: December 16, 2014 Ref. Report No. ISL-14LE520CE : Rechargeable Battery Pack : M12USXXXXXXXX (X can be 0-9, A-Z, blank) : APC : Darfon Electronics Corp. : 167-1, Shanying Road, Gueishan, Taoyuan 33347, Taiwan We,, hereby certify that: The device bearing the trade name and model specified above has been shown to comply with the applicable technical standards as indicated in the measurement report and was tested in accordance with the measurement procedures specified in European Council Directive- EMC Directive 2004/108/EC. The device was passed the test performed according to : Standards: EN 55022: 2010+AC2011 and CISPR 22: 2008 (modified) EN 61000-3-2: 2006+A1:2009 +A2:2009 and IEC 61000-3-2: 2005+A1:2008 +A2:2009 EN 61000-3-3: 2013 and IEC 61000-3-3: 2013 EN 55024: 2010 and CISPR 24: 2010 EN 61000-4-2: 2009 and IEC 61000-4-2: 2008 EN 61000-4-3: 2006+A1: 2008 +A2: 2010 and IEC 61000-4-3:2006+A1: 2007+A2: 2010 EN 61000-4-8: 2010 and IEC 61000-4-8: 2009 I attest to the accuracy of data and all measurements reported herein were performed by me or were made under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the qualifications of all persons taking them. Hsi-Chih LAB: No. 65, Gu Dai Keng Street, Hsi-Chih Dist., New Taipei City 221, Taiwan Tel: 886-2-2646-2550; Fax: 886-2-2646-4641 Jim Chu / Director Lung-Tan LAB: No. 120, Lane 180, San Ho Tsuen, Hsin Ho Rd., Lung-Tan Hsiang, Tao Yuan County 325, Taiwan Tel: 886-3-407-1718; Fax: 886-3407-1738

CE MARK TECHNICAL FILE AS/NZS EMC CONSTRUCTION FILE of Product Name Rechargeable Battery Pack Model M12USXXXXXXXX (X can be 0-9, A-Z, blank) Brand APC Contains: 1. Declaration of Conformity 2. EN55022/CISPR 22, AS/NZS CISPR 22 EMI test report 3. EN55024/CISPR 24, EN61000-3-2 / IEC 61000-3-2, and EN61000-3-3 / IEC 61000-3-3 test report 4. Block Diagram and Schematics 5. Users manual

Page 1 of 2 Report No. ISL-14LE520CE Declaration of Conformity Name of Responsible Party: Darfon Electronics Corp. Address of Responsible Party: 167-1, Shanying Road, Gueishan, Taoyuan 33347, Taiwan Declares that product: Model: Brand: Assembled by: Address: Rechargeable Battery Pack M12USXXXXXXXX (X can be 0-9, A-Z, blank) APC Same as above Same as above Conforms to the EMC Directive 2004/108/EC as attested by conformity with the following harmonized standards: EN 55022:2010+AC:2011, CISPR 22:2008 (modified) and AS/NZS CISPR 22: 2009+A1:2010: Limits and methods of measurement of Radio Interference characteristics of Information Technology Equipment. EN 55024:2010 and CISPR 24:2010: Information technology equipment-immunity characteristics - Limits and methods of measurement. EN 61000-4-2:2009 IEC 61000-4-2:2008 Standard Description Results Criteria EN 61000-4-3:2006+A1:2008 +A2:2010 IEC 61000-4-3:2006+A1:2007+A2:2010 EN 61000-4-8:2010 IEC 61000-4-8:2009 Electrostatic Discharge Pass B Radio-Frequency, Electromagnetic Field Pass Power Frequency Magnetic Field Pass A Standard Description Results EN 61000-3-2:2006 +A1:2009 +A2:2009 IEC 61000-3-2:2005 +A1:2008 +A2:2009 EN 61000-3-3:2013 IEC 61000-3-3:2013 Limits for harmonics current emissions Limits for voltage fluctuations and flicker in low-voltage supply systems. A Pass Pass We, Darfon Electronics Corp., hereby declare that the equipment bearing the trade name and model number specified above was tested conforming to the applicable Rules under the most accurate measurement standards possible, and that all the necessary steps have been taken and are in force to assure that production units of the same equipment will continue to comply with the requirements. --------------------------- Darfon Electronics Corp. Date: December 16, 2014

Page 1 of 2 Report No. ISL-14LE520CE Declaration of Conformity Name of Responsible Party: Darfon Electronics Corp. Address of Responsible Party: 167-1, Shanying Road, Gueishan, Taoyuan 33347, Taiwan Declares that product: Model: Brand: Assembled by: Address: Rechargeable Battery Pack M12USXXXXXXXX (X can be 0-9, A-Z, blank) APC Same as above Same as above Conforms to the EMI part of RCM Mark requirements as attested by conformity with the following standards: EN 55022:2010+AC:2011, CISPR 22:2008 (modified) and AS/NZS CISPR 22: 2009+A1:2010: Limits and methods of measurement of Radio Interference characteristics of Information Technology Equipment. EN 55024:2010 and CISPR 24:2010: Information technology equipment-immunity characteristics - Limits and methods of measurement. EN 61000-4-2:2009 IEC 61000-4-2:2008 Standard Description Results Criteria EN 61000-4-3:2006+A1:2008 +A2:2010 IEC 61000-4-3:2006+A1:2007+A2:2010 EN 61000-4-8:2010 IEC 61000-4-8:2009 Electrostatic Discharge Pass B Radio-Frequency, Electromagnetic Field Pass Power Frequency Magnetic Field Pass A Standard Description Results EN 61000-3-2:2006 +A1:2009 +A2:2009 IEC 61000-3-2:2005 +A1:2008 +A2:2009 EN 61000-3-3:2013 IEC 61000-3-3:2013 Limits for harmonics current emissions Limits for voltage fluctuations and flicker in low-voltage supply systems. A Pass Pass We, Darfon Electronics Corp., hereby declare that the equipment bearing the trade name and model number specified above was tested conforming to the applicable Rules under the most accurate measurement standards possible, and that all the necessary steps have been taken and are in force to assure that production units of the same equipment will continue to comply with the requirements. --------------------------- Darfon Electronics Corp. Date: December 16, 2014

CE TEST REPORT of EN55022 / CISPR 22 / AS/NZS CISPR 22 Class B EN55024 / CISPR 24 / IMMUNITY EN61000-3-2 / EN61000-3-3 Product : Rechargeable Battery Pack Model(s): M12USXXXXXXXX (X can be 0-9, A-Z, blank) Brand: APC Applicant: Darfon Electronics Corp. Address: 167-1, Shanying Road, Gueishan, Taoyuan 33347, Taiwan Test Performed by: <Lung-Tan LAB> *Site Registration No. BSMI: SL2-IN-E-0013; SL2-R1/R2-E-0013; TAF: 0997 FCC: TW1036; IC: IC4067B-1; NEMKO: ELA 113B VCCI: <Conduction 02>C-1440, T-1676, <Conduction 03>C-2845, T-1464, <Chamber 02>R-1435, G-17, <Chamber 12>R-2598,G-16, <Chamber 14>G-211, *Address: No. 120, Lane 180, San Ho Tsuen, Hsin Ho Rd. Lung-Tan Hsiang, Tao Yuan County 325, Taiwan *Tel: 886-3-407-1718; Fax: 886-3-407-1738 Report No.: ISL-14LE520CE Issue Date : December 16, 2014 This report totally contains 41 pages including this cover page and contents page. Test results given in this report apply only to the specific sample(s) tested and are traceable to national or international standard through calibration of the equipment and evaluating measurement uncertainty herein. This test report shall not be reproduced except in full, without the written approval of.

-i- Contents of Report 1. General...1 1.1 Certification of Accuracy of Test Data...1 1.2 Test Standards...2 1.3 Description of EUT...4 1.4 Description of Support Equipment...5 1.5 Software for Controlling Support Unit...6 1.6 I/O Cable Condition of EUT and Support Units...7 2. Power Main Port Conducted Emissions...8 2.1 Test Setup and Procedure...8 2.2 Conduction Test Data: Configuration 1...9 2.3 Test Setup Photo...11 3. Telecommunication Port Conducted Emissions...13 3.1 Test Setup and Procedure...13 4. Radiated Disturbance Emissions...14 4.1 Test Setup and Procedure...14 4.2 Radiation Test Data: Configuration 1...16 4.3 Test Setup Photo...18 5. Electrostatic discharge (ESD) immunity...19 5.1 Test Specification...19 5.2 Test Setup...19 5.3 Test Result...19 5.4 Test Point: Configuration 1...20 5.5 Test Point: Configuration 2...22 5.6 Test Setup Photo...23 6. Radio-Frequency, Electromagnetic Field immunity...24 6.1 Test Specification...24 6.2 Test Setup...24 6.3 Test Result...24 6.4 Test Setup Photo...25 7. Power Frequency Magnetic Field immunity...26 7.1 Test Specification...26 7.2 Test Setup...26 7.3 Test Result...26 7.4 Test Setup Photo...27 8. Harmonics...28 8.1 Test Specification...28 8.2 Test Setup...28 8.3 Test Result...28 8.4 Test Data...29 8.5 Test Setup Photo...31 9. Voltage Fluctuations...32 9.1 Test Specification...32 9.2 Test Setup...32 9.3 Test Result...32 9.4 Test Data...33 9.5 Test Setup Photo...34

-ii- Contents of Report 10. Appendix...35 10.1 Appendix A: Test Equipment...35 10.2 Appendix B: Uncertainty of Measurement...37 10.3 Appendix C: Photographs of EUT Please refer to the File of ISL-14LE520P...38

1. General -1-1.1 Certification of Accuracy of Test Data Standards: Please refer to 1.2 Equipment Tested: Rechargeable Battery Pack Model: M12USXXXXXXXX (X can be 0-9, A-Z, blank) Brand: APC Applicant: Darfon Electronics Corp. Sample received Date: December 4, 2014 Final test Date: EMI: refer to the date of test data EMS: December 15, 2014 Test Site: Chamber 02;; Conduction 03; Immunity 02 Test Distance: 10M Temperature: refer to each site test data Humidity: refer to each site test data Input power: Conduction input power: AC 230 V / 50 Hz Radiation input power: AC 230 V / 50 Hz Immunity input power: AC 230 V / 50 Hz Test Result: PASS Report Engineer: Elly Duan Test Engineer: Steve Liao Approved By: --------------------------------------- Jim Chu / Director

1.2 Test Standards The tests which this report describes were conducted by an independent electromagnetic compatibility consultant, in accordance with the following -2- EN 55022:2010+AC:2011, CISPR 22:2008 (modified) and AS/NZS CISPR 22: 2009+A1:2010: Class B: Limits and methods of measurement of Radio Interference characteristics of Information Technology Equipment. EN 55024:2010 and CISPR 24:2010: Information technology equipment-immunity characteristics - Limits and methods of measurement. EN 61000-4-2:2009 IEC 61000-4-2:2008 Standard Description Results Criteria EN 61000-4-3:2006+A1:2008 +A2:2010 IEC 61000-4-3:2006+A1:2007+A2:2010 EN 61000-4-6:2009 IEC 61000-4-6:2008 EN 61000-4-8:2010 IEC 61000-4-8:2009 Electrostatic Discharge Pass B Radio-Frequency, Electromagnetic Field Pass Conductive Disturbance Pass A Power Frequency Magnetic Field Pass A Standard Description Results EN 61000-3-2:2006 +A1:2009 +A2:2009 IEC 61000-3-2:2005 +A1:2008 +A2:2009 EN 61000-3-3:2013 IEC 61000-3-3:2013 Limits for harmonics current emissions Limits for voltage fluctuations and flicker in low-voltage supply systems. A Pass Pass

1.2.1 Performance Criteria for Compliance: EN 55024-3- Performance criterion A During and after the test the EUT shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed below a minimum performance level specified by the manufacturer when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. If the minimum performance level or the permissible performance loss is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the EUT if used as intended. Performance criterion B After the test, the EUT shall continue to operate as intended without operator intervention. No degradation of performance or loss of function is allowed, after the application of the phenomena below a performance level specified by the manufacturer, when the EUT is used as intended. The performance level may be replaced by a permissible loss of performance. During the test, degradation of performance is allowed. However, no change of operating state or stored data is allowed to persist after the test. If the minimum performance level (or the permissible performance loss) is not specified by the manufacturer, then either of these may be derived from the product description and documentation, and by what the user may reasonably expect from the EUT if used as intended. Performance criterion C During and after testing, a temporary loss of function is allowed, provided the function is self-recoverable, or can be restored by the operation of the controls or cycling of the power to the EUT by the user in accordance with the manufacturer s instructions. Functions, and/or information stored in non-volatile memory, or protected by a battery backup, shall not be lost.

1.3 Description of EUT EUT Description: Battery Pack (Power Bank) Condition: Pre-Production Model: M12USXXXXXXXX (X can be 0-9, A-Z, blank) Serial Number: N/A Max power output: 5Vdc/3.4A Micro USB cable: 1m * 1 Highest working frequency: 32MHz The devices can be installed inside the EUT are listed below: Component Vendor Description Battery LG LGDBMG11865 The I/O ports of EUT are listed below: I/O Port Type Quantity Micro USB input port (5V/2.1A) 1 USB output port (5V/2.4A) 1 USB output port (5V/1.0A) 1-4- Pretest configuration: For Radiation pretest configurations: 1~2 For Conduction pretest configuration: 1 Configuration Micro USB input port USB output USB output port (5V/2.1A) port (5V/2.4A) (5V/1.0A) Mode 1 Input N/A N/A Charge 2 N/A 2.4A 1A Discharge The entire pretest configurations are tested. The test worst configuration is listed below: Test EMI and EMS (except Electrostatic Discharge test) configurations: Micro USB input port USB output port USB output port Configuration Mode (5V/2.1A) (5V/2.4A) (5V/1.0A) 1 Input N/A N/A Charge For Electrostatic Discharge Test configuration: Configuration Micro USB input port USB output port USB output port (5V/2.1A) (5V/2.4A) (5V/1.0A) Mode 1 Input N/A N/A Charge 2 N/A 2.4A 1A Discharge EMI Noise Source:: Refer to the photo Control IC Point EUT-12 32MHz U13 EMI Solution: N/A

-5-1.4 Description of Support Equipment For EMI test support unit: 1~6 For EMS (except Electrostatic Discharge test configuration 2) test support unit: 2~7 For Electrostatic Discharge test configuration 2: support unit: 8~9 No Unit Model / Serial No. Brand Power Cord FCC ID 1 24 LCD Monitor ST 2420Lb S/N: NA DELL Non-shielded FCC DOC 2 Personal Computer 3 PS/2 Mouse 4 PS/2 Keyboard 5 Aceex Modem 6 HP Printer 7 24 LCD Monitor 8 9 Dummy load (for 2.4A) Dummy load (for 1.0 A) BTO-LM-OFFICE-C S/N: N/A M-SBM96B S/N: NA Y-S0002 S/N: N/A DM1414 S/N: N/A C930 S/N: N/A 2408FPW S/N: NA N/A S/N: N/A N/A S/N: N/A LEMEL Non-shielded FCC DOC Logitch N/A FCC DOC Logitch N/A FCC DOC Aceex Non-shielded FCC DOC HP Non-shielded FCC DOC DELL Non-shielded FCC DOC N/A N/A N/A N/A N/A N/A

-6-1.5 Software for Controlling Support Unit Test programs exercising various part of EUT were used. The programs were executed as follows: For EMI and EMS (except Electrostatic Discharge configuration 2) test: 1. Charging EUT through Personal Computer USB port 2. Send H pattern to the 24 LCD Monitor through PC D-SUB Port. 3. Send signal to the Printer through PC parallel Port. 4. Send signal to the Modem through PC Serial Port. 5. Repeat the above steps. Filename Issued Date Printer IntelEMC 04/11/2007 Modem IntelEMC 04/11/2007 24 LCD Monitor IntelEMC 04/11/2007 For Electrostatic Discharge test configuration 2: 1. EUT discharge to Dummy load. 2. Repeat the above steps.

-7-1.6 I/O Cable Condition of EUT and Support Units For EMI and EMS (except Electrostatic Discharge configuration 2): Description Path Cable Length Cable Type AC Power Cable 110V (~240V) to PC SPS 1.8m Non-shielded PS/2 Keyboard Data Cable PS/2 Mouse Data Cable PS/2 Keyboard to PC PS/2 Keyboard Port 1.8m Shielded PS/2 Mouse to PC PS/2 Port 1.8m Shielded Printer Data Cable Printer to PC Parallel Port 1.8m Shielded Modem Data Cable Modem to PC Serial Port 1.8m Shielded Monitor Data Cable Micro USB cable Monitor D-SUB Port to PC D-SUB Port 1.8m PC USB port to EUT micro USB input port 1m Shielded (with core) Shielded For Electrostatic Discharge configuration 2: Description Path Cable Length Cable Type Micro USB cable EUT USB output port with dummy load (for 5V, 2,4A) 1m Shielded Micro USB cable EUT USB output port with dummy load (for 5V, 1.0A) 1m Non-shielded

2. Power Main Port Conducted Emissions 2.1 Test Setup and Procedure 2.1.1 Test Setup -8-2.1.2 Test Procedure The measurements are performed in a 3.5m x 3.4m x 2.5m shielded room, which referred as Conduction 01 test site, or a 3m x 3m x 2.3m test site, which referred as Conduction 02 test site. The EUT was placed on non-conduction 1.0m x 1.5m table, which is 0.8 meters above an earth-grounded. Power to the EUT was provided through the LISN which has the Impedance (50ohm/50uH) vs. Frequency Characteristic in accordance with the standard. Power to the LISNs were filtered to eliminate ambient signal interference and these filters were bonded to the ground plane. Peripheral equipment required to provide a functional system (support equipment) for EUT testing was powered from the second LISN through a ganged, metal power outlet box which is bonded to the ground plane at the LISN. The interconnecting cables were arranged and moved to get the maximum measurement. Both the line of power cord, hot and neutral, were measured. All of the interface cables were manipulated according to EN 55022 requirements. The highest emissions were analyzed in details by operating the spectrum analyzer in fixed tuned mode to determine the nature of the emissions and to provide information which could be useful in reducing their amplitude. 2.1.3 EMI Receiver/Spectrum Analyzer Configuration (for the frequencies tested) Frequency Range: Detector Function: Resolution Bandwidth: 150KHz--30MHz Quasi-Peak / Average Mode 9KHz

2.2 Conduction Test Data: Configuration 1 Table 2.2.1 Power Line Conducted Emissions (Line) -9- Note: Margin = QP/AVG Emission - Limit QP/AVG Emission = Receiver Reading + Correct Factor Correct Factor = LISN Loss + Cable Loss A margin of -8dB means that the emission is 8dB below the limit The frequency spectrum graph is for final peak graph, and the attached table is for QP/AVG test result. If peak data can pass, it will be shown in QP/AVG Correct column, if not, QP/AVG data will instead.

-10- Table 2.2.2 Power Line Conducted Emissions (Neutral) Note: Margin = QP/AVG Emission - Limit QP/AVG Emission = Receiver Reading + Correct Factor Correct Factor = LISN Loss + Cable Loss A margin of -8dB means that the emission is 8dB below the limit The frequency spectrum graph is for final peak graph, and the attached table is for QP/AVG test result. If peak data can pass, it will be shown in QP/AVG Correct column, if not, QP/AVG data will instead.

-11-2.3 Test Setup Photo Front View

-12- Back View

-13-3. Telecommunication Port Conducted Emissions 3.1 Test Setup and Procedure 3.1.1 Test Setup 3.1.2 Test Procedure The measurements are performed in a 3.5m x 3.4m x 2.5m shielded room, which referred as Conduction 01 test site, or a 3m x 3m x 2.3m test site, which referred as Conduction 02 test site. The EUT was placed on non-conduction 1.0m x 1.5m table, which is 0.8 meters above an earth-grounded. The EUT, any support equipment, and any interconnecting cables were arranged and moved to get the maximum measurement. All of the interface cables were manipulated according to EN 55022 requirements. The port of the EUT was connected to the support equipment through the ISN and linked in normal condition. AC input power for the EUT & the support equipment power outlets were obtained from the same filtered source that provided input power to the LISN. The highest emissions were analyzed in details by operating the spectrum analyzer in fixed tuned mode to determine the nature of the emissions and to provide information could be useful in reducing their amplitude. 3.1.3 EMI Receiver/Spectrum Analyzer Configuration (for the frequencies tested) Frequency Range: Detector Function: Resolution Bandwidth: 150KHz--30MHz Quasi-Peak / Average Mode 9KHz **Remarks: It is not necessary to be tested on this item.

-14-4. Radiated Disturbance Emissions 4.1 Test Setup and Procedure 4.1.1 Test Setup

-15-4.1.2 Test Procedure The radiated emissions test will then be repeated on the open site or chamber to measure the amplitudes accurately and without the multiple reflections existing in the shielded room. The EUT and support equipment are set up on the turntable of one of 10 meter open field sites or 10 meter chamber. Desktop EUT are set up on a wooden stand 0.8 meter above the ground or floor-standing arrangement shall be placed on the horizontal ground reference plane. The test volume for a height of up to 30 cm may be obstructed by absorber placed on the ground plane. For the initial measurements, the receiving antenna is varied from 1-4 meter height and is changed in the vertical plane from vertical to horizontal polarization at each frequency. The highest emissions between 30 MHz to 1000 MHz were analyzed in details by operating the spectrum analyzer and/or EMI receiver in quasi-peak mode to determine the precise amplitude of the emissions. The highest emissions between 1 GHz to 6 GHz were analyzed in details by operating the spectrum analyzer in peak and average mode to determine the precise amplitude of the emissions. At the highest amplitudes observed, the EUT is rotated in the horizontal plane while changing the antenna polarization in the vertical plane to maximize the reading. The interconnecting cables were arranged and moved to get the maximum measurement. Once the maximum reading is obtained, the antenna elevation and polarization will be varied between specified limits to maximize the readings. All of the interface cables were manipulated according to EN 55022 requirements. The highest internal source of an EUT is defined as the highest frequency generated or used within the EUT or on which the EUT operates or tunes. If the highest frequency of the internal sources of the EUT is less than 108 MHz, the measurement shall only be made up to 1 GHz. If the highest frequency of the internal sources of the EUT is between 108 MHz and 500 MHz, the measurement shall only be made up to 2 GHz. If the highest frequency of the internal sources of the EUT is between 500 MHz and 1 GHz, the measurement shall only be made up to 5 GHz. If the highest frequency of the internal sources of the EUT is above 1 GHz, the measurement shall be made up to 5 times the highest frequency or 6 GHz, whichever is less. 4.1.3 Spectrum Analyzer Configuration (for the frequencies tested) Frequency Range: Detector Function: Resolution Bandwidth: Frequency Range: Detector Function: Resolution Bandwidth: 30MHz--1000MHz Quasi-Peak Mode 120KHz Above 1 GHz to 6 GHz Peak/Average Mode 1MHz

-16-4.2 Radiation Test Data: Configuration 1 Table 4.2.1 Radiated Emissions (Horizontal) * Note: Margin = Emission Limit Emission = Radiated Amplitude + Correct Factor Correct Factor = Antenna Correction Factor + Cable Loss A margin of -8dB means that the emission is 8dB below the limit BILOG Antenna Distance: 10 meters Below 1GHz test, if the peak measured value meets the QP limit, it is unnecessary to perform the QP measurement.

-17- Table 4.2.2 Radiated Emissions (Vertical) * Note: Margin = Emission Limit Emission = Radiated Amplitude + Correct Factor Correct Factor = Antenna Correction Factor + Cable Loss A margin of -8dB means that the emission is 8dB below the limit BILOG Antenna Distance: 10 meters Below 1GHz test, if the peak measured value meets the QP limit, it is unnecessary to perform the QP measurement.

-18-4.3 Test Setup Photo Front View (30MHz~1GHz) Back View (30MHz~1GHz)

-19-5. Electrostatic discharge (ESD) immunity 5.1 Test Specification Port: Enclosure Basic Standard: EN 61000-4-2/ IEC EN61000-4-2 (details referred to Sec 1.2) Test Level: Air +/- 2 kv, +/- 4 kv, +/- 8 kv Contact +/- 4 kv Criteria: B Test Procedure refer to ISL QA -T4-E-S7 Temperature: 22 C Humidity: 45% Selected Test Point Air: discharges were applied to slots, aperture or insulating surfaces. 10 single air discharges were applied to each selected points. Contact: Total 200 discharges minimum were to the selected contact points. Indirect Contact Points: 25 discharges were applied to center of one edge of VCP and each EUT side of HCP with 10 cm away from EUT. 5.2 Test Setup EUT is 1m from the wall and other metallic structure. When Battery test mode is needed, a cable with one 470K resister at two rare ends is connected from metallic part of EUT and screwed to HCP. For battery test mode 10cm VCP: 0.5m x 0.5m 470K 470K 80cm EUT 0.5mm insulation HCP: 1.6m x 0.8m Non-Metallic Table 470K 5.3 Test Result Ground reference Plane Performance of EUT complies with the given specification.

-20-5.4 Test Point: Configuration 1 Red arrow lines indicate the contact points, and blue arrow lines indicate the air points.

-21-

-22-5.5 Test Point: Configuration 2 Red arrow lines indicate the contact points, and blue arrow lines indicate the air points.

-23-5.6 Test Setup Photo Configuration 1 Configuration 2

6. Radio-Frequency, Electromagnetic Field immunity -24-6.1 Test Specification Port: Enclosure Basic Standard: EN 61000-4-3/ IEC EN61000-4-3 (details referred to Sec 1.2) Test Level: 3 V/m Modulation: AM 1KHz 80% Frequency range: 80 MHz~1 GHz Frequency Step: 1% of last step frequency Dwell time: 3s Polarization: Vertical and Horizontal EUT Azimuth Angle 0 90 180 270 Criteria: A Test Procedure refer to ISL QA -T4-E-S8 Temperature: 23 C Humidity: 58% 6.2 Test Setup The field sensor is placed at one calibration grid point to check the intensity of the established fields on both polarizations. EUT is adjusted to have each side of EUT face coincident with the calibration plane. A CCD camera and speakers are used to monitor the condition of EUT for the performance judgment. 6.3 Test Result Performance of EUT complies with the given specification.

-25-6.4 Test Setup Photo

-26-7. Power Frequency Magnetic Field immunity 7.1 Test Specification Port: Basic Standard: Test Level: Polarization: Criteria: Test Procedure Temperature: 23 C Humidity: 61% Enclosure EN 61000-4-8/ IEC EN61000-4-8 (details referred to Sec 1.2) 1A/m X, Y, Z A refer to ISL QA -T4-E-S12 7.2 Test Setup Induction Coil (1m x 1m) EUT To AC main To AC main Insulation A E 80cm Non-Metallic Table Test Generator 7.3 Test Result Performance of EUT complies with the given specification.

-27-7.4 Test Setup Photo

8. Harmonics -28-8.1 Test Specification Port: AC mains Active Input Power: >75W Basic Standard: EN61000-3-2/IEC 61000-3-2 (details referred to Sec 1.2) Test Duration: 2.5min Class: A Test Procedure refer to ISL QA -T4-E-S14 Temperature: 22 C Humidity: 59% Test Procedure The EUT is supplied in series with shunts or current transformers from a source having the same nominal voltage and frequency as the rated supply voltage and frequency of the EUT. The EUT is configured to its rated current with additional resistive load when the testing is performed. Equipment having more than one rated voltage shall be tested at the rated voltage producing the highest harmonics as compared with the limits. 8.2 Test Setup 8.3 Test Result Performance of EUT complies with the given specification.

-29-8.4 Test Data Urms = 230.5V Freq = 50.000 Range: 5 A Irms = 0.664A Ipk = 0.703A cf = 1.933 P = 76.20W S = 83.85VA pf = 0.499 THDi = 34.6 % THDu = 0.10 % Class A Test - Time : 3min ( 100 %) Test completed, Result: PASSED Order Freq. Iavg Iavg%L Irms Irms%L Imax Imax%L Limit Status [Hz] [A] [%] [A] [%] [A] [%] [A] 1 50 0.3341 0.3394 0.3537 2 100 0.0000 0.0000 0.0015 0.1413 0.0040 0.3673 1.0800 3 150 0.1107 4.8110 0.1114 4.8430 0.1144 4.9757 2.3000 4 200 0.0000 0.0000 0.0003 0.0710 0.0006 0.1419 0.4300 5 250 0.0227 1.9917 0.0229 2.0077 0.0235 2.0613 1.1400 6 300 0.0000 0.0000 0.0003 0.1017 0.0012 0.4069 0.3000 7 350 0.0056 0.7280 0.0058 0.7530 0.0082 1.0701 0.7700 8 400 0.0000 0.0000 0.0003 0.1327 0.0009 0.3981 0.2300 9 450 0.0178 4.4524 0.0177 4.4250 0.0183 4.5776 0.4000 10 500 0.0000 0.0000 0.0003 0.1659 0.0006 0.3317 0.1840 11 550 0.0100 3.0328 0.0101 3.0518 0.0107 3.2367 0.3300 12 600 0.0000 0.0000 0.0003 0.1990 0.0009 0.5971 0.1533 13 650 0.0078 3.7291 0.0079 3.7784 0.0092 4.3597 0.2100 14 700 0.0000 0.0000 0.0003 0.2322 0.0006 0.4644 0.1314 15 750 0.0000 0.0000 0.0027 1.8311 0.0040 2.6449 0.1500 16 800 0.0000 0.0000 0.0003 0.2654 0.0006 0.5307 0.1150 17 850 0.0075 5.6579 0.0076 5.7644 0.0092 6.9173 0.1324 18 900 0.0000 0.0000 0.0006 0.5971 0.0009 0.8956 0.1022 19 950 0.0076 6.4109 0.0076 6.4426 0.0089 7.4734 0.1184 20 1000 0.0000 0.0000 0.0006 0.6634 0.0009 0.9951 0.0920 21 1050 0.0059 5.4609 0.0058 5.4118 0.0067 6.2663 0.1071 22 1100 0.0000 0.0000 0.0006 0.7298 0.0009 1.0947 0.0836 23 1150 0.0019 1.9308 0.0052 5.3033 0.0055 5.6152 0.0978 24 1200 0.0000 0.0000 0.0006 0.7961 0.0009 1.1942 0.0767 25 1250 0.0000 0.0000 0.0034 3.7299 0.0040 4.4081 0.0900 26 1300 0.0000 0.0000 0.0006 0.8625 0.0009 1.2937 0.0708 27 1350 0.0000 0.0000 0.0037 4.3945 0.0046 5.4932 0.0833 28 1400 0.0000 0.0000 0.0006 0.9288 0.0009 1.3932 0.0657 29 1450 0.0001 0.1244 0.0046 5.9001 0.0055 7.0801 0.0776 30 1500 0.0000 0.0000 0.0009 1.4927 0.0012 1.9903 0.0613 31 1550 0.0007 0.9524 0.0040 5.4660 0.0055 7.5684 0.0726 32 1600 0.0000 0.0000 0.0006 1.0615 0.0009 1.5922 0.0575 33 1650 0.0000 0.0000 0.0034 4.9235 0.0040 5.8187 0.0682 34 1700 0.0000 0.0000 0.0006 1.1278 0.0009 1.6917 0.0541 35 1750 0.0000 0.0000 0.0027 4.2725 0.0034 5.2219 0.0643 36 1800 0.0000 0.0000 0.0009 1.7912 0.0012 2.3883 0.0511 37 1850 0.0000 0.0000 0.0034 5.5203 0.0037 6.0221 0.0608 38 1900 0.0000 0.0000 0.0009 1.8908 0.0012 2.5210 0.0484 39 1950 0.0000 0.0000 0.0027 4.7607 0.0031 5.2897 0.0577 40 2000 0.0000 0.0000 0.0009 1.9903 0.0012 2.6537 0.0460

-30-

-31-8.5 Test Setup Photo Refer to the Setup Photo for Voltage Fluctuations

9. Voltage Fluctuations -32-9.1 Test Specification Port: Basic Standard: AC mains EN61000-3-3/IEC61000-3-3 (details referred to Sec 1.2) refer to ISL QA -T4-E-S14 For Pst 10min Test Procedure Observation period: For Plt 2 hours Temperature: 22 C Humidity: 59% Test Procedure The EUT is supplied in series with reference impedance from a power source with the voltage and frequency as the nominal supply voltage and frequency of the EUT. 9.2 Test Setup 9.3 Test Result Performance of EUT complies with the given specification.

-33-9.4 Test Data

-34-9.5 Test Setup Photo

10. Appendix 10.1 Appendix A: Test Equipment 10.1.1 Test Equipment List Location Con03 Equipment Name Brand Model S/N Last Cal. Date Next Cal. Date Conduction 03 EMI Receiver 11 ROHDE & ESCI 100568 07/19/2014 07/19/2015 SCHWARZ Conduction 03 LISN 20 R&S ENV216 101477 06/06/2014 06/06/2015 Conduction 03 LISN 08 ROHDE&SCHW FCC-LISN-50/25 07039 03/11/2014 03/11/2015 ARZ 0-25/2/01 Conduction 03 Conduction 03-1 Cable WOKEN CFD 300-NL Conduction 03-1 07/11/2014 07/11/2015 Location Chamber02 Radiation (Chamber02) Radiation (Chamber02) Radiation (Chamber02) Equipment Name Brand Model S/N Last Cal. Date Next Cal. Date BILOG Antenna 15 Teseq GmbH CBL6112D 27622 01/23/2014 01/23/2015 Coaxial Cable Chmb 02-10M-02 EMI Receiver 12 MIYAZAK 8D-FB Chmb 02-10M-02 10/17/2014 10/17/2015 ROHDE & ESCI 100804 07/29/2014 07/29/2015 SCHWARZ -35- Location Equipment Name Brand Model S/N Last Cal. Date Next Cal. Date EN61K-3-2/3 Harmonic/Flicker Test EMC PARTNER HARMONICS- 143 04/11/2014 04/11/2015 System 02 1000 EN61K-4-2 ESD Gun 05 EM TEST Dito V0640101838 05/26/2014 05/26/2015 EN61K-4-3 Broadband AR AT1080 310698 N/A N/A Log-Periodic Antenna EN61K-4-3 Horn Antenna RF-01 AR ATS700M11G 0335864 N/A N/A EN61K-4-3 Amplifier 80Mz~1GHz AR 250W1000A 312494 N/A N/A 250W EN61K-4-3 Amplifier AR 50S1G4M1 312762 N/A N/A 800MHz~4.2GHz 50W EN61K-4-3 Amplifier 4.0~8.0GHz 35W AR 35S4G8AM1 0335752 N/A N/A EN61K-4-3 Broadband Coupler 80M~1GHz Amplifier Research DC6180A 0341805 N/A N/A EN61K-4-3 Coaxial Cable INSULATED NPS-4806-2360 108599.003.01.03 N/A N/A -NP3 EN61K-4-3 Broadband Coupler AR DC7144A 0335226 N/A N/A 0.8G~4.26GHz EN61K-4-3 Broadband Coupler AR DC7350A 0335817 N/A N/A 4G~8GHz EN61K-4-3 Signal Generator 07 ROHDE& SMB100A 107780 09/30/2014 09/30/2015 SCHWARZ EN61K-4-8 Magnetic Field Immunity Loop FCC F-1000-4-8-L-1 M 01037 06/18/2014 06/18/2015 EN61K-4-8 Magnetic Field Test FCC F-1000-4-8-G-1 01038 06/18/2014 06/18/2015 Generator 25A PS: N/A => The equipment does not need calibration.

10.1.2 Software for Controlling Spectrum/Receiver and Calculating Test Data -36- Test Item Filename Version EN61000-3-2 EMC Partner 4.2 EN61000-3-3 EMC Partner 4.2 EN61000-4-2 N/A 2.0 EN61000-4-3 i2 4.130102k EN61000-4-8 N/A Site Filename Version Issue Date Conduction/Radiation EZ EMC ISL-03A2 3/6/2013

-37-10.2 Appendix B: Uncertainty of Measurement The measurement uncertainty refers to CISPR 16-4-2:2011. The coverage factor k = 2 yields approximately a 95 % level of confidence. <Conduction 03> AMN: ±3.28dB <Chamber 02 (10M)> Horizontal 30MHz~200MHz: 200MHz~1000MHz: Vertical 30MHz~200MHz: 200MHz~1000MHz: ±3.70dB ±4.19dB ±4.28dB ±4.15dB <Immunity 02> Test item EN61000-4-2 (ESD) Rise time tr 15% Peak current Ip 6.3% Current at 30 ns 6.3% Current at 60 ns 6.3% EN61000-4-3 (RS) ± 2.19dB EN61000-4-8 (Magnetic) ± 4.8% Uncertainty EN61000-3-2 (Harmonics) Test item Uncertainty Test item Uncertainty ± 3.98% EN61000-3-3 (Fluctuations and Flicker) ± 3.98 %

-38-10.3 Appendix C: Photographs of EUT Please refer to the File of ISL-14LE520P

Appendix Photographs of EUT of Product Name Rechargeable Battery Pack Model M12USXXXXXXXX (X can be 0-9, A-Z, blank) Brand APC Report Number: ISL-14LE520P

-1- EUT-1. EUT-2. Report Number: ISL-14LE520P

EUT-3. -2- EUT-4. Report Number: ISL-14LE520P

EUT-5. -3- EUT-6. Report Number: ISL-14LE520P

EUT-7. -4- EUT-8. Report Number: ISL-14LE520P

EUT-9. -5- EUT-10. LGDBMG11865 Report Number: ISL-14LE520P

EUT-11. -6- EUT-12. MCU 32MHz Report Number: ISL-14LE520P