A Proposal of Standard Calibration Laboratory for RICs

Similar documents
Case study Realistic and best uncertainties with humidity instruments

Environment-Laboratory Ambient Conditions

Basic Climatological Station Metadata Current status. Metadata compiled: 30 JAN Synoptic Network, Reference Climate Stations

How do I measure the amount of water vapor in the air?

Gravimetric determination of pipette errors

Soil Suction. Total Suction

GMP 11. Good Measurement Practice for Assignment and Adjustment of Calibration Intervals for Laboratory Standards

AES GUIDELINES FOR CO-OPERATIVE CLIMATOLOGICAL AUTOSTATIONS VERSION 2.0. October 1992

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

2. The map below shows high-pressure and low-pressure weather systems in the United States.

Dew-Point Measurement Solutions

OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Solar Radiation Measurement. Bruce W Forgan, WMO RAV Metrology Workshop, Melbourne, Novemberr 2011

Temperature and Humidity

EXPLANATION OF WEATHER ELEMENTS AND VARIABLES FOR THE DAVIS VANTAGE PRO 2 MIDSTREAM WEATHER STATION

Partnerships Implementing Engineering Education Worcester Polytechnic Institute Worcester Public Schools

Summary Report on National and Regional Projects set-up in Russian Federation to integrate different Ground-based Observing Systems

REDUCING UNCERTAINTY IN SOLAR ENERGY ESTIMATES

When the fluid velocity is zero, called the hydrostatic condition, the pressure variation is due only to the weight of the fluid.

Calibration. How can you get lower costs for the calibration? What is traceability? What is measurement uncertainty? What is calibration?

HAY MOISTURE & WEATHER:

Temperature Calibration; Depths of Immersion

Humid Air. Water vapor in air. Trace Glasses 1% Argon (A) Water vapor (H 2

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

American Society of Agricultural and Biological Engineers

Lesson 2: Thermometers & Temperature Scales

PROMPT ENGINEERING & TRADING SERVICES CO. W.L.L P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

RFP GP Clarifications to Bidders III

15. Liquid-in-Glass Thermometry

Weather Forecasting. DELTA SCIENCE READER Overview Before Reading Guide the Reading After Reading

Design qualification and type approval of PV modules

Thermal environments. Tel

II. Related Activities

WEATHER STATION FOR SOLAR FARM MONITORING

Developing Continuous SCM/CRM Forcing Using NWP Products Constrained by ARM Observations

Improved Meteorological Measurements from Merchant Ships. Peter K. Taylor and Elizabeth C. Kent Southampton Oceanography Centre, UK

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Pressure in Fluids. Introduction

Solar Input Data for PV Energy Modeling

Accurate Air Flow Measurement in Electronics Cooling

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

Schedule of Accreditation issued by United Kingdom Accreditation Service High Street, Feltham, Middlesex, TW13 4UN, UK

Solar Flux and Flux Density. Lecture 3: Global Energy Cycle. Solar Energy Incident On the Earth. Solar Flux Density Reaching Earth

Page 1. Weather Unit Exam Pre-Test Questions

Chapter 4 Atmospheric Pressure and Wind

Calibration of Dallas sensors

Experiment SURFACE TENSION OF LIQUIDS. Experiment 1, page 1 Version of June 17, 2016

UNIT 6a TEST REVIEW. 1. A weather instrument is shown below.

EQUIPMENT CALIBRATION/MAINTENANCE

Heikki Turtiainen *, Pauli Nylander and Pekka Puura Vaisala Oyj, Helsinki, Finland. Risto Hölttä Vaisala Inc, Boulder, Colorado

Weather Instruments, Maps and Charts

Relative Humidity Calibration Kit

THE HUMIDITY/MOISTURE HANDBOOK

Observing the weather Some advice if you are an amateur, or at a school, and thinking of making weather measurements

Establishment of the Gas Flow Calibration Facility at CSIR-NPL, India

SURFACE OBSERVING TECHNOLOGIES AND SYSTEMS.

The NEW Advanced Range of Portable Temperature Calibrators PROVISIONAL. Portable Dry Blocks, Liquid Baths and Multi-functional Heat Sources

Calibration & Preventative Maintenance. Sally Wolfgang Manager, Quality Operations Merck & Co., Inc.

Total Heat Versus Sensible Heat Evaporator Selection Methods & Application

Chapter 2: Solar Radiation and Seasons

WEATHER AND CLIMATE practice test

CHAPTER 2 Energy and Earth

Name Date Class STATES OF MATTER. SECTION 13.1 THE NATURE OF GASES (pages )

CHAPTER 3: FORCES AND PRESSURE

Eastern Caribbean Open-Source Geospatial Data Sharing and Management Workshop

WIKA INSTRUMENT CORPORATION

FOR SUBSCRIBERS ONLY! - TRIAL PASSWORD USERS MAY NOT REPRODUCE AND DISTRIBUTE PRINTABLE MATERIALS OFF THE SOLPASS WEBSITE!

Conductivity measurement on pure water according to the recommendations of the USP Pharmacopoeia USP24-NF19

4.3. David E. Rudack*, Meteorological Development Laboratory Office of Science and Technology National Weather Service, NOAA 1.

Humidity, Condensation, Clouds, and Fog. Water in the Atmosphere

Overview of the IR channels and their applications

Rusty Walker, Corporate Trainer Hill PHOENIX

LARGE MEASUREMENT RANGE MECHANICAL COMPARATOR FOR CALIBRATION OF LONG GAUGE BLOCKS

Optimum Solar Orientation: Miami, Florida

Osamu Ijima. Radiation Section, Atmospheric Environment Division, Global Environment and Marine Department, Japan Meteorological Agency (JMA)

Improvement in the Assessment of SIRS Broadband Longwave Radiation Data Quality

Rense Product Range. Customized Humidity Solutions. Rense Product Range

THIRD GRADE WEATHER 1 WEEK LESSON PLANS AND ACTIVITIES

Monitoring System Performance

Experience. The Atlas Difference.

Lecture 1: A Brief Survey of the Atmosphere

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

Advances in Thermal Dispersion Mass Flow Meter Accuracy

Operational experienced of an 8.64 kwp grid-connected PV array

1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K

The Next Generation Flux Analysis: Adding Clear-Sky LW and LW Cloud Effects, Cloud Optical Depths, and Improved Sky Cover Estimates

Chapter 10 Temperature and Heat

Clouds and the Energy Cycle

Mixing Valves. ARGUS Application Note: Mixing Valves

NSW Air Quality Monitoring Network: Quality Assurance Procedures

5. Why does the weather near cities tend to be cloudier and wetter than in rural areas?

Fundamentals of Mass Flow Control

Seasonal Temperature Variations

KALIBRERINGSBEVIS. 25 temperature loggers Ecoguard model TS , identification se table of results.

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

Chapter 7 Measurement of Sunshine Duration and. Solar Radiation

Laboratory Exercise: Calibration of a Thermometer

Use of numerical weather forecast predictions in soil moisture modelling

Transcription:

A Proposal of Standard Calibration Laboratory for RICs Yizhuo Sha (National Centre for Meteorological Metrology, Atmospheric Observation Technology Centre, CMA, Beijing, 100081) Abstract According to WMO, considered the need for regular calibration and maintenance of meteorological instruments to meet the increasing needs for high quality meteorological and hydrological data, the requirements of Members for standardization of meteorological instruments, the need for international instrument comparisons and evaluations, it was recommended to establish Regional Instrument Centres. RICs are designated to carry out the following main functions: (a) To keep a set of meteorological standard instruments linked with recognized international or national standards and to log their performance and elements of comparison; (b) To assist Members of the Region in calibrating their national standard meteorological instruments or in comparing them with the standard instruments mentioned in (a) above and to keep the Members of the Region and the WMO Secretariat informed on the available standard instruments; (c) To be prepared to certify the instruments conformity with the standards, with reference to WMO recommendations; (d) To organize instrument evaluations and comparisons, following standard methods; (e) To advise Members of the Region concerned on their enquiries regarding instrument performance and the availability of relevant guidance material; But up to now, there are no detail proposals for establishing a standard calibration. This paper will give three proposals to establish a standard meteorological metrology calibration laboratory for RICs. 1. General requirements for standard calibration instruments The achievable uncertainties can be obtained with good instrument systems that are properly operated. The most important requirements for meteorological instruments are: (a) Uncertainty (according to the stated requirement for the particular variable); (b) Reliability and stability; With regard to the above two requirements, it is important that an instrument should be able to maintain a known uncertainty over a long period. In order to control effectively the standardization of meteorological instruments on a national and international scale, a system of national and regional standards has been adopted by WMO. In general, regional standards are designated by the Regional Associations and national standards by the individual Members. Unless otherwise specified, instruments designated as regional and national standards should be compared by means of travelling standards at least once every five years. Similarly, the instruments in operational use in a Service should be periodically compared directly or indirectly with the national standards. 1

The ability of individual sensors or observing systems to meet the stated requirements is changing constantly as instrumentation and observing technology advance. For some of the quantities, these uncertainties are achievable only with the highest quality equipment and procedures. 1.1 Temperature LABORATORY STANDARDS standard thermometers will be held and maintained at national standards laboratories. A national meteorological or other accredited calibration laboratory will have, as a working standard, a high-grade platinum resistance thermometer, traceable to the national standard. The uncertainty of this thermometer may be checked periodically in a water triple-point cell. The triple-point of water is exactly defined and can be reproduced in a triple-point cell with an uncertainty of 1 10-4 K. Laboratory calibrations of thermometers should be carried out by national testing institutions or accredited calibration laboratories. For liquid-in-glass thermometers, a liquid bath should be employed, within which it should be possible to maintain the temperature at any desired values within the required range. The rate of temperature change within the liquid should not exceed the recommended limits and the calibration apparatus should be provided with a means of stirring the liquid. The reference thermometers and thermometers under test should be suspended independently of the container, fully immersed, and should not touch the sides. Sufficient measurements should be made to ensure that the corrections to be applied represent the performance of the thermometer under normal conditions with errors due to interpolation at any intermediate point not exceeding the non-systematic errors. 1.2 Air Pressure Analysed pressure fields are a fundamental requirement of the science of meteorology. It is imperative that these pressure fields be accurately defined as they form the basis for all subsequent predictions of the state of the atmosphere. Pressure measurements must be as accurate as technology will allow, within realistic financial constraints, and there must be uniformity in the measurement and calibration procedures across national boundaries. In view of the importance of accurate pressure observations, especially for aeronautical and synoptic purposes, and in view of the various possible errors to which mercury barometers are subject, all station barometers should be checked regularly by an inspector. PRIMARY STANDARD BAROMETER One possible primary standard for atmospheric pressure consists of a precision dead weight tester that produces a calibrated pressure related to the precision weights used and the local gravity field. This type of barometer is relatively simple and does not suffer from the problem of excessive drift of mercury barometers in a polluted environment. The primary standard barometer may well be a high-quality mercury barometer specially designed for that purpose. The primary standard mercury barometer must have a high vacuum, contain very pure mercury with a well-known density maintained at a constant temperature, and be located in an environment where pollution effects are prevented. The barometer also needs a calibrated measure (scale) and an optical read-out facility. These types of barometers measure absolute pressure with high absolute accuracy, while dead weight testers are gauge 2

pressure measuring instruments. 1.3 Humidity Humidity measurements at the Earth s surface are required for meteorological analysis and forecasting, for climate studies, and for many special applications in hydrology, agriculture, aeronautical services and environmental studies, in general. They are particularly important for their relevance to the changes of state of water in the atmosphere. Principles involved in the calibration of hygrometers Precision in the calibration of humidity sensors entails special problems, to a great extent owing to the relatively small quantity of water vapor which can exist in an air sample at normal temperatures, but also due to the general difficulty of isolating and containing gases and, more particularly, vapor. An ordered hierarchy of international traceability in humidity standards is only presently emerging. An absolute standard for humidity (i.e. a realization of the physical definition for the quantity of humidity) can be achieved by gravimetric hygrometry. The reference psychrometer (within its limited range) is also a form of primary standard, in that its performance is calculable. The calibration of secondary, reference, and working standards involves several steps. 1.4 The various fluxes of radiation to and from the Earth s surface are amongst the most important variables in the heat economy of the Earth as a whole and either at any individual place at the Earth s surface or in the atmosphere. measurements are used for the following purposes: (a) Study of the transformation of energy within the Earth-atmosphere system and of its variation in time and space; (b) Analysis of the properties and distribution of the atmosphere with regard to its constituents, such as aerosols, water vapor, ozone, etc.; (c) Study of the distribution and the variations of incoming, outgoing, and net radiation; (d) Satisfaction of the needs of biological, medical, agricultural, architectural and industrial activities with respect to radiation; (e) Verification of satellite radiation measurements and algorithms. Such applications require a widely distributed regular series of records of solar and terrestrial surface radiation components, and the derivation of representative measures of the net radiation. In addition to the publication of serial values for individual observing stations, an essential object must be the production of comprehensive radiation climatologies, whereby the daily and seasonal variations of the various radiation constituents of the general thermal budget may be more precisely evaluated and their relationships with other meteorological elements better understood. A RIC should satisfy the following conditions: (a) It should possess and maintain a standard group of radiometers, which consists, of either three standard radiometers of the Ångström, silver-disk or absolute radiometer type or of two absolute radiometers; (b) One of the standard radiometers should be compared at least once every five years against 3

the World Standard Group; (c) The standard radiometers should be intercompared at least once a year to check the stability of the individual instruments. If the ratio has changed by more than 0.2 per cent and if the erroneous instrument cannot be identified, then a recalibration at one of the World Centres has to be performed prior to further use as standard; (d) It should have the necessary facilities and laboratory equipment for checking and maintaining the accuracy of the auxiliary measuring equipment; (e) It should provide the necessary outdoor facilities for simultaneous comparison of national standard radiometers from the Region; 1.5 Wind Wind observations or measurements are required for weather monitoring and forecasting, for wind load climatology, for probability of wind damage and estimation of wind energy, and as part of the estimation of surface fluxes, e.g. evaporation, for air pollution dispersion and for agricultural applications. An accuracy for horizontal speed of 0.5 m s-1 below 5 m s-1 and better than 10 per cent above 5 m s-1 is usually sufficient. Wind direction should be measured with an accuracy of 5. A fully reliable calibration of cup, propeller, and vane anemometers is possible only in a wind tunnel; Wind-tunnel tests are useful for special projects or for type-testing new models. 2. Standard Configuration of Calibration Instruments The configuration proposals are based on the two factors. One is the economic conditions of the RIC Member country, the other is upon the technology level of the present time. 2.1 Basic Level of Standard Instruments The basic configuration proposal laboratory is designed to carry out the basic international comparison in RIC. Table 1 The Basic Configuration Proposal For RIC s Laboratory Mercury -40 C to +50 C Temperature secondary Platinum -50 C to +50 C 0.025 C Humidity secondary Psychrometer -50 C to +80 C Pressure secondary Mercury 500-1100hPa Quartz 500-1100 hpa 8.3+ 5.10-5 p secondary Pyranometer 305-2800nm 20W/m 2 Wind secondary Pitot Tube 0-30m/s 1m/s rainfall secondary Bottle 2.2 Moderate Level of Standard Instruments The moderate configuration proposal laboratory is designed to carry out the basic international comparison in RIC and among the RICs. 4

Table 2 The Moderate Configuration Proposal For RIC s Laboratory Temperature Platinum -80 C to +50 C 0.025 C Humidity Pressure Chilled Mirror Dew Point 10%RH-99%RH 1%RH Piston 500-1100 hpa 0.035hPa Secondary Pyrheliometer 305-2800nm 20W/m 2 Wind Secondary Hot Wire Anemometer 0-30m/s 1% or 0.5m/s rainfall Secondary Mass set 25-500mm/h 2.3 The higher Level of Standard Instruments A higher configuration proposal of standard laboratory should consider more elements to be calibrated with much more higher uncertainty. Table 3 A Higher Configuration Proposal For RIC s Laboratory Temperature Standard resistance Platinum platinum thermometer -80 156 o C 0.002 C Humidity Chilled mirror Dewpoint, Two-pressure humidity generator 1% RH to 99%RH (-50 to50 C) 1% of measured value Pressure Digital piston manometer 500 hpa to1200hpa 6 Pa Absolute radiometer Pyrgeometer 5.3% Pyrheliometer 1.5% Pyranometer 3 % Wind Pitot Tube and Differential Pressure Gauge, Hot wire Anemometer 0-75 m/s 0.1 m/s Rainfall Secondary Flow bench 0-2000mm/h 1% Ozone Photometric O 3 analyzer 2 ppb Spectrophotometer 1% Visibility secondary FD 12 10m-50 km 10% 5