REG-D & REG-DA Voltage Regulating Relays: E-LAN and the Group List

Similar documents
NC-12 Modbus Application

OPTICAL FIBER repeaters/ isolators

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Modular I/O System Analog and Digital Interface Modules

INTRODUCTION FEATURES OF THE ICM

Quick installation guide for the Vista Quantum QNVR Network Video Recorder

OPT SERIAL TO FIBER OPTIC CONVERTER

Modbus and ION Technology

TX2123 RS485 TO ETHERNET ADAPTOR

ABB RTU560A Series CMU & Modules

Networks. The two main network types are: Peer networks

EZ-View Network Communications Guide

Planning BACnet networks

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

RS232C < - > RS485 CONVERTER S MANUAL. Model: LD15U. Phone: / 97 / 98 (M)

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Tutorial: Configuring GOOSE in MiCOM S1 Studio 1. Requirements

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Voice Over Internet Protocol (VoIP) Configuration

PD 100A. Printing data system

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

ALARMS-xx. Remote Alarm Unit Setup Guide RESET ALL

INSTALLATION MANUAL XM3 Reader

Communication Setup Application Note

Operation and Installation Manual

DSX Master Communications

Using a Laptop Computer with a USB or Serial Port Adapter to Communicate With the Eagle System

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

M-Bus Network Installation Notes

Practical steps for a successful. PROFIBUS Project. Presented by Dr. Xiu Ji Manchester Metropolitan University

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Config software for D2 systems USER S MANUAL

Setting up VPN Access for Remote Diagnostics Support

Remote Serial over IP Introduction on serial connections via IP/Ethernet

EDI Distributor Control Interface Wiring and Setup Instructions

DUKANE Intelligent Assembly Solutions

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Designing VM2 Application Boards

WEB log. Device connection plans

2-Pair. Managed SHDSL Ethernet Extender. User s Manual

RS-422/485 Multiport Serial PCI Card. RS-422/485 Multiport Serial PCI Card Installation Guide

Chapter 1 Connecting the Router to the Internet

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Secure Ethernet Gateway SEG-1 and SEG-M for IEI Access Systems Installation Manual

1-Port R422/485 Serial PCIe Card

Disturbance Recoder SPCR 8C27. Product Guide

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

FIBER OPTIC APPLICATION IN A PROFIBUS NETWORK

Application Note - Connecting an Electricity Meter to SolarEdge Devices (Europe and APAC)

Network Design. Yiannos Mylonas

Temperature & Humidity SMS Alert Controller

: Interconnecting Cisco Networking Devices Part 1 v2.0 (ICND1)

OZW30. Central Unit SYNERGYR

TELECOM HF VHF UHF over IP

IS SERIES. QuikStart Programming Guide. IP Network Direct System. Programming Videos

Modification of an AOR AR-8600 receiver to tune it with a ACECO FC-3002 frequency finder

The Answer to the 14 Most Frequently Asked Modbus Questions

Kurz MODBUS Client User s Guide

C24-CAMANL Video Server/Encoder

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

Modbus and ION Technology

Doors in a Network Environment

PLC training panel (Twido version)

SNMP Web Management. User s Manual For SNMP Web Card/Box

How to Set Up a Wireless Network. How to configure a wireless network for a computer science programming contest using PC 2

Setup guide. point to point wall plate extenders

Universal Push2TV HD Adapter PTVU1000 Installation Guide

User Manual V SDM220MODBUS. Single-Phase Two Module DIN rail Meters

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

HSG Engineering Tech Bulletin

Power Feeding Equipment for Optical Submarine Cable Systems

Nu-Lec Training Modules

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

USER MANUAL GUIMGR Graphical User Interface Manager for FRM301/FRM401 Media Racks

Wireless DMX Connector

BACnet Wiring Guidelines. For Price Controls MANUAL INSTALLATION

Setting Up the ZigBee Ethernet Gateway

User manual Rev 1.3 Contents

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

H.323 / SIP VoIP Gateway VIP GW. Quick Installation Guide

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

1.3. The network element must have the ability to be configured in a point to point, point to multi point, and daisy chain configuration.

Configuring the Siemens TC35 modems for use with the MI2292

GV-Data Capture V3 Series User's Manual

NESS-APX. Training Manual

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

Advanced Data Capture and Control Systems

Remote Sources. Facility. Router

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Transcription:

REG-D & REG-DA Voltage Regulating Relays: E-LAN and the Group List E-LAN is a communications system that allows A.Eberle Voltage Regulating relays to share all the data required to operate transformers in parallel and also allows engineering access to all supported relays in a substation from a single point. An E-LAN connection is a basic requirement for the use of the Master-Follower and Circulating-Current [ΔIsinΦ and ΔIsinΦ(S)] parallel programs. It is also conveniently allows the sharing of switchgear statuses between relays for operation of the Paragramer function reducing I/O wiring. The E-LAN can be used to connect Voltage Regulators that are not in the same paralleling group, and can also be connected to other supported A.Eberle devices. The protocol is based on RS-485. Relays can be ordered in copper or copper+fibre E-LAN variants. The copper E-LAN ports can be connected via either 2-wire or 4-wire copper shielded twisted pair with the connection-mode selected via software. Method Attributes 2-wire Single multi-drop connection to multiple relays Up to 100 m distance 4-wire Point-to-point connection Up to 1,500 m distance Table 1. Attributes of 2-wire and 4-wire connection. Each relay has two E-LAN ports, referred to as E-LAN left (E-LAN L) and E-LAN right (E-LAN R). Data received at one E- LAN port on a device will automatically be retransmitted out its other E-LAN port. This allows the connection of multiple devices in a chain if using 4-wire or fibre connections. However, the 2-wire method is commonly used as this offers the advantage that E-LAN communications between other devices is still possible even if a device is powered down. Figure 1. An E-LAN network using multiple point-to-point links. The laptop connected to the front-port of the relay at the left can use the E-LAN to connect WinREG to any of the relays. HV Power File:E-LAN and Group List Page 1 of 8

Physical connections and parameters Each E-LAN port has 4 data terminals. EA+, EA-, E+ & E1. The terminal numbers for the REG-DA relay are shown in Table 2. Terminal numbering on REG-D relays depends on the user-defined options selected at the time of ordering so it is necessary to refer to the terminal diagram provided with the relay. Function REG-DA Terminal E-LAN L E-LAN R EA+ 72 76 EA- 71 75 E+ 70 74 E- 69 73 Table 2. Terminal markings for REG-DA. The 2-wire connection method is the simplest and is recommended in most cases The EA+ terminal of a port should be connected to the EA+ terminal of one port on each of the other relays. The EA- terminals should also be connected in the same way. Normal RS-485 wiring practices should be followed, where connections for intermediately relays are joined at the regulator terminals- avoiding T connections. (Refer Figure 10 for example). For the 4-wire method all 4 terminals are used. EA+ from one relay should connect to the EA+ on the next relay. EA-, E+ and E- terminals follow the same pattern. In a chain, where one relay needs to connect to two other relays, then both E-LAN ports should be used, with separate wiring for each connection. (Refer Figure 12 for example). Relays with fibre optic E-LAN ports have multi-mode ST connectors for Transmit and Receive lines. The Transmit on one relay should be connected to the Receive on the next relay. The Left and Right naming of the E-LAN ports relates to the physical location of the ports on the device the terminals for the E-LAN L port are closer to the left-hand side than those of the E-LAN R port. There is no relationship between these names and the structure of the E-LAN network or to the physical layout of the transformers or relays on the site. It is possible to connect and E-LAN L port on one device with an E-LAN R port on the next device. The transformer layout within the Paragramer display is defined in the Group List not the E-LAN arrangement. There can only be one path between two relays in an E-LAN network. Ring structures or parallel paths between relays are not supported, as per standard RS485 convention. The maximum length of connection between devices depends on the connection method. 2-wire connections can be up to 100 m long. The maximum length of 4-wire connection varies with the data-rate selected as shown in Table 3. Fibre connections can typically be up to 1500 m. Baud rate (kbps) Maximum distance (km) 15.6-62.5 1.5 125 1.0 375 0.8 Table 3. Maximum distance of 4-wire E-LAN connections. HV Power File:E-LAN and Group List Page 2 of 8

Three setting parameters are available to configure each port (refer Figure 2): Mode: allows selection between 2-wire and 4-wire methods of connection. For fibre-optic connections 4- wire should be used. Baudrate: set the communications data rate in kbps Termination: this controls whether internal termination resistors are enabled. This should be set ON for devices at each end of an E-LAN bus to prevent data reflections. Figure 2. Default 2-wire E-LAN settings shown in WinREG. Communications settings for unused ports are not important and can be left as default if desired. Device ID and the Group List: Each device on an E-LAN network needs to be set with a unique Station ID. This is used as its address on the E-LAN network. To set this using WinREG a separate Send button is used to send this parameter separate from the other parameters (Figure 3). The Station ID can also be used as the address that the SCADA protocol card uses to communicate within the relay, so care needs to be taken if making any modifications to ID s in installed schemes. Figure 3. Sending the Station ID to a relay from WinREG. The Group List is the list of Station IDs on the E-LAN that are to be used within the Parallel Programs or by the Paragramer function. The Group List must be identical for every device in the group including listing the devices in exactly the same order. The Group List does not need to list every device on the E-LAN, just those Transformers that could be in parallel. Contact HV Power to discuss complex schemes. The Group List can edited via WinREG (Figure 4) where any ID can be entered. If editing the Group List via the relay front panel (or with WinREG where there is a communication connection to a relay) then only those devices that are currently available (active) on the E-LAN may be selected. HV Power File:E-LAN and Group List Page 3 of 8

Figure 4. Editing the group list in WinREG off-line, allows any ID to be entered. The order of the relays in the Group List is important as it affects: The order the relays are shown on the display using the Paragramer. The relay at the top of the group list will be at the left hand side in the Paragramer. The priority of which relay is assigned as the Master relay in a Master Follower scheme (where Paragramer is used). Commissioning tools The status of each E-LAN port on the device can be viewed on the front panel of the device in the E-LAN page, accessible from the Setup 6 menu (Figure 5). A solid cross indicates an E-LAN connection is active on this port. If the cross is flashing or is not displayed, it indicates a problem with the connection. Possible causes are: Incorrect wiring E-LAN settings not matching between connected devices A duplicate ID in the Group List Identical Station ID s on the E-LAN LED functions 14: and 15: are available for displaying the status of each port. F3 Figure 5. The E-LAN setup and commissioning page is accessed via the Setup 6 menu. Here the [X] shown for the E- LAN LEFT port indicates that it is active. The Group List can be also be accessed via the relay front panel from the Setup 1 menu (Figure 6). The IDs of all devices programmed into the Group List will be displayed. Those devices that are not presently accessible via E-LAN will be shown enclosed in brackets (Figure 7). A symbol is also displayed next to each ID this indicates the parallelprogram groupings that are presently active. Devices operating in parallel will share a common symbol. F1 F5 F1 F5 Figure 6. The Group List is located deep within the menu levels. HV Power File:E-LAN and Group List Page 4 of 8

Figure 7. An Example of a Group List of three relays. T1 & T2 share a common symbol (*) so are operating in parallel. The brackets around the T3 ID indicate that it is not accessible via E-LAN. E-LAN error An E-LAN error signal will be generated if any device programmed in the Group List is not accessible via E-LAN for more than 30 seconds. The signal can be set as an alarm via LED, binary output or SCADA protocol but can also be used to directly control the behaviour of the regulator. If the parameter Manual Locked at ELAN Error is set, an E- LAN error will cause the relay to switch from Automatic to Manual mode. This can be useful when relay are operating in a Parallel Program as sharing of statuses between parallel relays is no longer possible. The exact effect of this parameter varies depending on which Parallel Program is selected. Accessing a remote relay via E-LAN From within WinREG it is possible to send and retrieve settings from any device connected to the E-LAN network from the front port of any of the devices in the network (Figure 8). The local device (to which you are directly connected) will be marked as (AA:). Figure 8. Selection of the device on the E-LAN network to connect to via WinREG. The relay that the computer is directly connected to is indicated by (AA:). Connection to the other devices would be via E-LAN. Mapping Limit-Signals to Binary Outputs, LEDs or SCADA Any user-assignable LED can be set to the state of the E-LAN L or E-LAN R connections (Table 4). An E-LAN error can also be used to activate an LED or binary output. The LOG mask can be used to record occurrences. HV Power File:E-LAN and Group List Page 5 of 8

Signal Output Relay LED Function Function E-LAN L connection available 14: E-LAN R connection available 15: E-LAN error 17:ELAN-Err 16:ELAN-Err Table 4. Output Relay and LED Functions. The E-LAN status signals and E-LAN error can also be mapped to a SCADA system interface. Refer to the documentation available for the selected SCADA protocol. Connection Examples These diagrams show data-connections only. All copper connections should be via shielded twisted pair cables. The usual practices regarding screening and earthing of communications cables within a substation environment should be observed. 2-wire Figure 9. An example of a 2-Wire E-LAN network for two relays. Only the left ports are use in this example. Terminated is set ON for both relays. 2-wire Figure 10. An example of a 2-Wire E-LAN network for three relays. The Termination setting is ON at the two devices at the end of the bus and OFF on the centre device. HV Power File:E-LAN and Group List Page 6 of 8

4-wire Figure 11. An example of a 4-Wire E-LAN network for two relays. 4-wire Figure 12. An example of a 4-Wire E-LAN network for three relays. Each link is a point-point connection so both E- LAN ports are used on the centre device. Fibre fibre fibre fibre fibre fibre fibre Figure 13. An example of an E-LAN via fibre. The connection parameters are the same as those for the 4-wire connection method. HV Power File:E-LAN and Group List Page 7 of 8

More Information: For further information on transformer control with A.Eberle Voltage Regulating Relays refer to http://www.hvpower.co.nz/technicallibrary/voltageregulators.html or contact HV Power. HV Power File:E-LAN and Group List Page 8 of 8