Certificate of Analysis

Similar documents
OMCL Network of the Council of Europe QUALITY MANAGEMENT DOCUMENT

Performance and advantages of qnmr measurements

ERDOSTEINE - MONOGRAPH.

LUMEFANTRINE Draft proposal for The International Pharmacopoeia (October 2006)

SUCRALOSE. White to off-white, practically odourless crystalline powder

Step-by-Step Analytical Methods Validation and Protocol in the Quality System Compliance Industry

POLYVINYL ALCOHOL. SYNONYMS Vinyl alcohol polymer, PVOH, INS No DEFINITION DESCRIPTION FUNCTIONAL USES CHARACTERISTICS

ß-CYCLODEXTRIN SYNONYMS

α-cyclodextrin SYNONYMS α-schardinger dextrin, α-dextrin, cyclohexaamylose, cyclomaltohexaose, α- cycloamylase

1.1 This test method covers the qualitative and quantitative determination of the content of benzene and toluene in hydrocarbon wax.

Tamsulosin Hydrochloride Capsules

Analytical Test Report

CERTIFICATE OF ANALYSIS Methyl 4-Hydroxybenzoate

Implementing New USP Chapters for Analytical Method Validation

CONFIRMATION OF ZOLPIDEM BY LIQUID CHROMATOGRAPHY MASS SPECTROMETRY

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

DRAFT MONOGRAPH FOR THE INTERNATIONAL PHARMACOPOEIA PARACETAMOL ORAL SUSPENSION (September 2010)

General and statistical principles for certification of RM ISO Guide 35 and Guide 34

Simultaneous determination of aspartame, benzoic acid, caffeine, and saccharin in sugar-free beverages using HPLC

Vitamin C quantification using reversed-phase ion-pairing HPLC

Calibration Certificate

CRM s and the Dilemma of the 2nd Source. Shawn Kassner, Sr Product Manager Tim Miller, Sr Organic Chemist Phenova, A Phenomenex Company

Stimuli to the Revision Process

International GMP Requirements for Quality Control Laboratories and Recomendations for Implementation

How To Test For Contamination In Large Volume Water

CORESTA RECOMMENDED METHOD Nº 80

United States Department of Agriculture Food Safety and Inspection Service, Office of Public Health Science

SIMULTANEOUS DETERMINATION OF TELMISARTAN AND HYDROCHLOROTHIAZIDE IN TABLET DOSAGE FORM USING REVERSE PHASE HIGH PERFORMANCE LIQUID CHROMATOGRAPHY

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

ETHYL LAUROYL ARGINATE

Analytical Test Method Validation Report Template

Annex 3. General guidelines for the establishment, maintenance and distribution of chemical reference substances. Introduction.

Carolina s Solution Preparation Manual

ANALYTICAL METHODS INTERNATIONAL QUALITY SYSTEMS

Intelligent use of Relative Response Factors in Gas Chromatography-Flame Ionisation Detection

The Uncertainty of Reference Standards A Guide to Understanding Factors Impacting Uncertainty, Uncertainty Calculations, and Vendor Certifications

EPA Method RSK 175 Dissolved Gasses in Water Matrices using the Teledyne Tekmar HT3 Headspace Analyzer. HT3 Application Note.

Reversed Phase High Presssure Liquid Chromatograhphic Technique for Determination of Sodium Alginate from Oral Suspension

Chemical analysis service, Turner s Green Technology Group

Method development for analysis of formaldehyde in foodsimulant. melamine-ware by GC-MS and LC-MS/MS. Internal Technical Report

Extraction of Cannabinoids in Marijuana and Edibles by QuEChERS

Technical Report. Automatic Identification and Semi-quantitative Analysis of Psychotropic Drugs in Serum Using GC/MS Forensic Toxicological Database

New drugs of abuse? A case study on Phenazepam & Methoxetamine

Develop a Quantitative Analytical Method for low (» 1 ppm) levels of Sulfate

Application Note # MS-14 Fast On-site Identification of Drugs with the mobile GC/MS system E²M

Validation and Calibration of Analytical Instruments a D.Gowrisankar, b K.Abbulu, c O.Bala Souri, K.Sujana*

C 5. chemical development contract research custom synthesis cgmp API manufacturing commercial production. Welcome to

SODIUM CARBOXYMETHYL CELLULOSE

Thermo Scientific Syncronis HPLC Columns. Technical Manual

Automated Method Development Utilizing Software-Based Optimization and Direct Instrument Control

COMPLIANCE BY DESIGN FOR PHARMACEUTICAL QUALITY CONTROL LABORATORIES INSIGHT FROM FDA WARNING LETTERS

The Characterization of Perfume Fragrances Using GC/MS, Headspace Trap and Olfactory Port

ACETALDEHYDE and ISOVALERALDEHYDE (Gas Chromatography)

Analysis of Vegetable Oils by High Performance Liquid Chromatography

A Complete Solution for Method Linearity in HPLC and UHPLC

Minor editorial changes have been made to update the monograph to the current USP style.

Automation of Solid Phase Extraction and Column Chromatographic Cleanup

Project 5: Scoville Heat Value of Foods HPLC Analysis of Capsaicinoids

Protocol: HPLC (amino acids)

EUDRAGIT E 100, EUDRAGIT E PO and

Simultaneous determination of L-ascorbic acid and D-iso-ascorbic acid (erythorbic acid) in wine by HPLC and UV-detection (Resolution Oeno 11/2008)

Drospirenone and Ethinyl Estradiol Tablets. Type of Posting. Revision Bulletin Posting Date. 31 July 2015 Official Date

Validation and Calibration. Definitions and Terminology

Purification of reaction mixtures using flash chromatography.

VALIDATION OF ANALYTICAL PROCEDURES: TEXT AND METHODOLOGY Q2(R1)

Form and content of COOMET сertificate for reference materials for composition and properties of substances and materials

UHPLC/MS: An Efficient Tool for Determination of Illicit Drugs

Guidance for Industry

FAO SPECIFICATIONS FOR PLANT PROTECTION PRODUCTS FOOD AND AGRICULTURE ORGANIZATION OF THE UNITED NATIONS

Gel Filtration Standard

Lean Process Improvements for the GMP Laboratory

Materials for Pharmaceutical Manufacturing

Quality. Now Certified to ISO 9001:2008

Opiates in Urine by SAMHSA GC/MS

Validating Methods using Waters Empower TM 2 Method. Validation. Manager

Analysis of Various Vitamins in Multivitamin Tablets

Fast and Accurate Analysis of Vitamin D Metabolites Using Novel Chromatographic Selectivity and Sample Preparation

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

USP Certificate PREDNISONE TABLETS. USP Catalog No.: USP Lot No.: R031Y0 (10 mg nominal prednisone content per tablet)

Determination of Pesticide Residues in Drinking Water Using Automated Solid-Phase Extraction and Gas Chromatography with Nitrogen Phosphorus Detection

IMPURITIES IN NEW DRUG PRODUCTS

EUROPEAN COMMISSION DIRECTORATE-GENERAL TAXATION AND CUSTOMS UNION TAX POLICY Excise duties and transport, environment and energy taxes

lung cancer targeted photodynamic therapy and imaging

IAS CALIBRATION and TESTING LABORATORY ACCREDITATION PROGRAMS DEFINITIONS

Technical Procedure for the Solid Phase Extraction of Acidic, Neutral and Basic Drugs for GC-MS Analysis

SIMULTANEOUS DETERMINATION OF NALTREXONE AND 6- -NALTREXOL IN SERUM BY HPLC

MOISTURE (Karl Fischer, Buffered)

TANNIC ACID. SYNONYMS Tannins (food grade), gallotannic acid, INS No. 181 DEFINITION DESCRIPTION

The Use of Micro Flow LC Coupled to MS/MS in Veterinary Drug Residue Analysis

AMBERLITE IRP64 Pharmaceutical Grade Cation Exchange Resin (Polacrilex Resin)

How To Use An Acquity Qda Detector

An Advanced Base Deactivated Capillary Column for analysis of Volatile amines Ammonia and Alcohols.

Gas Chromatography Liner Selection Guide

American Association for Laboratory Accreditation

PT/EQA STANDARDS AND GUIDELINES: QUALITY AND RELIABILITY OF TEST ITEMS

Thermo Scientific SOLA SPE cartridges and plates Technical Guide. Join the revolution. unparalleled performance

BRIEFING Plastic Packaging Systems for Pharmaceutical Use.

NEW CHEMICAL ENTITIES

Transcription:

Certificate of Analysis ISO GUIDE 34 ANAB Cert# AR-1470 ISO/IEC 17025 ANAB Cert# AT-1467 SODIUM BENZOATE CERTIFIED REFERENCE MATERIAL CERTIFIED PURITY: 99.8%, U crm = ±0.2% k = 3.2 (Mass Balance/as is basis) NOMINAL PACKAGE SIZE: 1g CATALOG #: PHR1231 LOT #: P500231 CERTIFICATE VERSION: 500231.4 ISSUE DATE: 30 September 2015 Note: Certificates may be updated due to Pharmacopeial Lot changes or the availability of new data. Check our website at: www.sigma-aldrich.com for the most current version. CRM EXPIRATION: 12 Months from Receipt (Proper Storage and Handling Required). RECEIPT DATE: Note: this space is provided for convenience only and its use is not required. STORAGE: Store at Room Temperature, keep container tightly closed. Attachment of a 20 mm aluminum crimp seal recommended for unused portions. CHEMICAL FORMULA: C 7 H 5 O 2 Na MW: 144.1 PHYSICAL DESCRIPTION: White powder in amber vial CAS #: 532-32-1 Page 1 of 6

HAZARDS: Read Safety Data Sheet before using. All chemical reference materials should be considered potentially hazardous and should be used only by qualified laboratory personnel. INSTRUCTIONS FOR USE: Do not dry, use on the as is basis. Material is hygroscopic. The internal pressure of the container may be slightly different from the atmospheric pressure at the user s location. Open slowly and carefully to avoid dispersion of the material. This material is intended for R&D use only. Not for drug, household or other uses. TRACEABILITY ASSAY Comparative assay demonstrates direct traceability to Pharmacopeial Standards Specification: 99.0-101.0% (USP) METHOD: HPLC (Ref: Sodium Benzoate, USP38) Column: Ascentis Express C18, 50 x 4.6mm, 2.7µm Mobile Phase: 20mM KH 2 PO 4 in Water (ph: 2.5), Acetonitrile (70:30) Flow Rate: 0.5mL/min Column Temperature: 30ºC Injection: 2µL Detector: 230nm ASSAY vs. USP BENZOIC ACID REFERENCE STANDARD (as is basis) ASSAY VALUE vs. USP LOT 100.3% H0L534 Labeled Content = 0.999mg/mg ASSAY vs. USP SODIUM BENZOATE REFERENCE STANDARD (as is basis) ASSAY VALUE vs. USP LOT 100.3% R016H0 Labeled Content = None Assigned Content= 100.0%* *The assigned content of the USP Sodium Benzoate RS was determined by assay against the USP Benzoic Acid Reference Standard Page 2 of 6

Representative Chromatogram from Lot: P500231 Analysis ASSAY BY TITRATION Method: Dissolve in glacial acetic acid, titrate with 0.1N perchloric acid. Mean of nine measurements: 99.7%, U crm = ±0.5% k = 2.3 PURITY DETERMINATION BY MASS BALANCE CHROMATOGRAPHIC IMPURITY ANALYSIS METHOD: HPLC Column: Ascentis C18, 150 x 4.6mm, 5µm Mobile Phase: Water, Methanol, Acetic Acid (60:40:1) Flow Rate: 0.5mL/min Column Temperature: 30ºC Injection: 20µL Detector: 270nm Total Impurity 1: 0.1% Representative Chromatogram from Lot: P500231 Impurity Analysis Page 3 of 6

RESIDUAL SOLVENTS Method: GC-MS Headspace (ref.: Residual Solvents <467>, USP34) Column: DB-1301 Carrier gas: He Flow: 1.2mL/min Split Ratio: 1:5 Injection/Temperature: 1µl/250 C Temperature Program: 40 C for 20min, 10 C/min to 240 C, hold 20min Solvents Detected: None WATER DETERMINATION Method: Karl Fisher titration Mean of three measurements, Water Content = 0.1% CERTIFIED PURITY BY MASS BALANCE [100% - Impurities (normalized)] IDENTIFICATION TESTS 99.8% U crm = ±0.2%, k = 3.2 (as is basis) INFRARED SPECTROPHOTOMETRY (Comparative identification analysis demonstrates direct traceability to Pharmacopeial standards) Page 4 of 6

1 H NMR (Data provided by an external laboratory; not in scope of accreditation) Consistent with structure ELEMENTAL ANALYSIS (Data provided by an external laboratory; not in scope of accreditation) Exeter Analytical 440 Elemental Analyzer Combustion method % Theoretical Result 1 Result 2 Mean C 58.35 58.41 58.48 58.45 H 3.50 3.51 3.54 3.53 HOMOGENEITY ASSESSMENT Homogeneity was assessed in accordance with ISO Guide 35. Completed units were sampled using a random stratified sampling protocol. The results of chemical analysis were then compared by Single Factor Analysis of Variance (ANOVA). The uncertainty due to homogeneity was derived from the ANOVA. Heterogeneity was not detected under the conditions of the ANOVA. Analytical Method: HPLC Sample size: ~50mg UNCERTAINTY STATEMENT Uncertainty values in this document are expressed as Expanded Uncertainty (U crm ) corresponding to the 95% confidence interval. U crm is derived from the combined standard uncertainty multiplied by the coverage factor k, which is obtained from a t- distribution and degrees of freedom. The components of combined standard uncertainty include the uncertainties due to characterization, homogeneity, long term stability, and short term stability (transport). The components due to stability are generally considered to be negligible unless otherwise indicated by stability studies. Page 5 of 6

STABILITY ASSESSMENT Significance of the stability assessment will be demonstrated if the analytical result of the study and the range of values represented by the Expanded Uncertainty do not overlap the result of the original assay and the range of its values represented by the Expanded Uncertainty. The method employed will usually be the same method used to characterize the assay value in the initial evaluation. Long Term Stability Evaluation - An assessment, or re-test, versus a Compendial Reference Standard may be scheduled, within the 3 year anniversary date of a release of a Secondary Standard. The re-test interval will be determined on a case-by-case basis. Short Term Stability Study - It is useful to assess stability under reasonably anticipated, short term transport conditions by simulating exposure of the product to humidity and temperature stress. This type of study is conducted under controlled conditions of elevated temperature and humidity. QC Supervisor QA Supervisor APPENDIX Original Release Date: 31 May 2012 Stability Test Date: 17 June 2013 Requalification Test Date: 17 June 2013 Requalification Test Date: 07 November 2013 Requalification Test Date: 30 September 2015 Manufactured and certified by Sigma-Aldrich RTC, Inc. 2931 Soldier Springs Rd, Laramie WY, USA 82070 (Phone): 1-307-742-5452 (Fax): 1-855-831-9212 email: RTCTechGroup@sial.com Page 6 of 6