ArbStudio Arbitrary Waveform Generators. Powerful, Versatile Waveform Creation

Similar documents
Arbitrary/Function Generators AFG3000C Series Datasheet

How To Use A High Definition Oscilloscope

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

Agilent 8904A Multifunction Synthesizer dc to 600 khz

Digital Storage Oscilloscopes Models 2540B, 2542B, 2540B-GEN, 2542B-GEN

APSYN420A/B Specification GHz Low Phase Noise Synthesizer

LogicLab s.r.l Via della valle Carate Brianza (MI) Tel Fax

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

NEW PRODUCT ANNOUCEMENT

U1602A Handheld Oscilloscopes, 20 MHz

Agilent Technologies 3000 Series Oscilloscopes

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

Impedance 50 (75 connectors via adapters)

FFT Spectrum Analyzers

AFG-100/200 series USB Modular Arbitrary Function Generator. Date: Oct, 2014

Agilent E5100A Network Analyzer

RF Measurements Using a Modular Digitizer

How To Use A Sound Card With A Subsonic Sound Card

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

Analogue/Digital Analogue and Differential Oscilloscopes

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

ECONseries Low Cost USB DAQ

DEVELOPMENT OF DEVICES AND METHODS FOR PHASE AND AC LINEARITY MEASUREMENTS IN DIGITIZERS

FREQUENCY RESPONSE ANALYZERS

RIGOL Data Sheet. DS1000E, DS1000D Series Digital Oscilloscopes DS1102E, DS1052E, DS1102D, DS1052D. Product Overview. Applications. Easy to Use Design

Ideal for high dynamic range measurements from compression to noise floor

User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual

PicoScope 6000A/B Series

MODEL INDEX ADS1152CA ADS1102CA ADS1062CA ADS1022C

R&S ZNBT8 Vector Network Analyzer Specifications

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

One Port Network Analyzer

SIGNAL GENERATORS and OSCILLOSCOPE CALIBRATION

R&S ZNC Vector Network Analyzer Specifications

Agilent U2761A USB Modular Function/Arbitrary Waveform Generator

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

khz to 2.7 GHz Spectrum Analyzer

Automotive. Aerospace. bout Us. Defense. Energy. Maritime. Education. Electronics. and more

User Manual. CFG253 3 MHz Function Generator

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

FREJA 300 Relay Testing System

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Wideband USB Synthesized Signal Generator. Dynamic range 70 db, output power from -60dBm to +10dBm in 0.25dB steps

Multi-Range Programmable DC Power Supplies 9115 Series

Multi-Range Programmable DC Power Supplies 9115 Series

[F/T] [5] [KHz] [AMP] [3] [V] 4 ) To set DC offset to -2.5V press the following keys [OFS] [+/-] [2] [.] [5] [V]

iva Cable & Antenna Analyzer

Propagation Channel Emulator ECP_V3

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

This document lists the specifications for the NI PXIe-5160, 500 MHz digitizer.

Successfully negotiating the PCI EXPRESS 2.0 Super Highway Towards Full Compliance

PC FUNCTION GENERATOR

Description: Multiparameter System (4 or 8 channels)

Agilent N4010A Wireless Connectivity Test Set

R&S ZVA Vector Network Analyzer Specifications

XR-2206 Monolithic Function Generator

Waveform Monitor Audio & Loudness Logging

USB Smart Power Sensor

PicoScope 2200A Series PC OSCILLOSCOPES WITH ARBITRARY WAVEFORM GENERATOR

DataSheet. SHS800 Series Handheld Digital Oscilloscope SHS820/SHS815/SHS810/SHS806. Application Domain

Timing Errors and Jitter

iva Cable & Antenna Analyzer

PicoScope 3000 A and B Series

TESTS OF 1 MHZ SIGNAL SOURCE FOR SPECTRUM ANALYZER CALIBRATION 7/8/08 Sam Wetterlin

LOW POWER SPREAD SPECTRUM OSCILLATOR

Vibration analysis and monitoring Compact. Powerful. Modern technology.

Embest DSO2300 USB Oscilloscope

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

FRAUNHOFER INSTITUTE FOR INTEg RATEd CIRCUITS IIS. drm TesT equipment

MPC 4. Machinery Protection Card Type MPC 4 FEATURES. Continuous on-line Machinery Protection Card

DS1104 R&D Controller Board

PicoScope 3000 Series

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT BIT DIFFERENTIAL ADC WITH I2C LTC2485 DESCRIPTION

PXI. GSM/EDGE Measurement Suite

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

DVT913 TV CHANNEL CONVERTER

PropScope USB Oscilloscope

The Effective Number of Bits (ENOB) of my R&S Digital Oscilloscope Technical Paper

DAC Digital To Analog Converter

US-Key New generation of High performances Ultrasonic device

The Model A032-ET of Riga Event Timers

Keysight Technologies N9320B RF Spectrum Analyzer

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

PCM Encoding and Decoding:

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

Current Probes. User Manual

FG , 08501K, 08502K, 08503, 08503K, 08504K

On-line Machine Condition Monitoring [The CMS System]

Keysight N9320B RF Spectrum Analyzer

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Handheld Digital Storage Oscilloscopes 2510 Series

High Power Programmable DC Power Supplies PVS Series

Figure 1: Multiple unsynchronized snapshots of the same sinusoidal signal.

Department of Electrical and Computer Engineering Ben-Gurion University of the Negev. LAB 1 - Introduction to USRP

Designing the Solution for Electrochemistry Potentiostat/Galvanostat І Battery Cycler І Fuel Cell Test Station І

ANALYZER BASICS WHAT IS AN FFT SPECTRUM ANALYZER? 2-1

Transponder for GainMaker Amplifiers

Transcription:

ArbStudio Arbitrary Waveform Generators Powerful, Versatile Waveform Creation

UNMATCHED WAVEFORM UNMATCHED WAVEFORM GENERATION GENERATION Key Features 125 MHz bandwidth 1 GS/s maximum sample rate Long memory 2 Mpts/Ch 16-bit resolution 2 and 4 channel models Arbitrary and Direct Digital Synthesis (DDS) modes Digital pattern generator PWM mode Sweep and burst modes Modulation AM, FM, PM, ASK, SK, PSK A Powerful Combination of Performance, Capabilities and Features A waveform generator must provide flexibility to cover a wide range of applications, high-performance to meet demanding signal requirements and be easy to use. ArbStudio Arbitrary Waveform Generators meet the needs of today s engineers and technicians with uncompromised performance, a wide variety of signal types, modulation schemes and generation modes all controlled through an intuitive, easy to use software interface. Unmatched Performance ArbStudio combines 125 MHz bandwidth with long 2 Mpts/Ch memory, fast 1 GS/s sample rate and high 16-bit resolution to provide performance unmatched by other generators. Other instruments make trade-offs between these specifications, only ArbStudio provides leading specification in every category. Along with this unmatched performance is the variety of models providing both 2 and 4 channel configurations as well as a digital pattern generator of up to 36 channels. 2

Intuitive User Interface The ArbStudio software provides an intuitive interface for creating, editing and sequencing waveforms. All channels, settings and controls can be accessed from the main screen. As waveforms are created they can be previewed in the graph display. Digital Pattern Generator Many systems have a variety of analog and digital signals yet most waveform generators provide only analog outputs. The ArbStudio 1102D and 1104D models provide analog and digital pattern generation with 18 or 36 channels respectively. Modulation Built-in modulation capabilities include AM, PM, FM, ASK, PSK and FSK. The modulation editor provides easy-to-use tools to configure the modulation scheme for any application. Pulse-Width Modulation Creating PWM signals has never been easier thanks to a dedicated control panel designed just for PWM waveforms. Easily set modulation shape, duty cycle and all other aspects of the PWM plus configure different settings for each channel. Function Generator All basic Sine, Square and Triangle waveforms can be created from a simple screen with controls that replicate a traditional bench top generator. Flexibility With both Arbitrary and Direct Digital Synthesis (DDS) ArbStudio offers extremely flexible generation capabilities. Math and noise functions are built-in and can be combined with waveforms. Up to 8 total 4 channel models can be synchronized with the AS-SYNC cable. 3

EASY ACCESS TO ALL WAVEFORM CREATION EASY ACCESS TO ALL WAVEFORM CREATION TOOLS TOOLS 4 ArbStudio has an intuitive software interface that brings all the important controls to the main screen providing easy access to all channels, output controls, trigger controls and waveform creation screens. 1. Channel Controls Access to all controls, waveforms and modulation capabilities of all channels. 2. Channel Status Set or update the status and configuration of each channel or digital pod. 3. Digital Pattern Output The 1102D and 1104D models offer simultaneously analog and digital pattern generation of 18 or 36 channels. 1 2 5 4. Output Controls Enable the waveform output and control ArbStudio triggering. 5. Waveform List Displays all waveforms that have been created during the current session or any waveform saved in the library. 3 4

8 6. Waveform Display See the waveforms as they are created or view the waveforms loaded in the sequencer. 7. Synchronization Ports Up to eight of the 4 channel models can be connected and synchronized to provide anywhere from 4 to 32 channels of simultaneous waveforms. 7 6 8. Waveform Sequencer Configure the waveform sequence with only a few mouse clicks and view the output below. 9. BNC Outputs ArbStudio is available in 2 and 4 channel configurations with a maximum output of 12 Vp-p. 10. Clock and Trigger Input/Output Trigger in and trigger out connections for working with other equipment are provided as well as an external clock input. 10 9 5

SPECIFICATIONS SPECIFICATIONS ArbStudio 1102 ArbStudio 1102D ArbStudio 1104 ArbStudio 1104D Number of Channels 2 4 Digital Pattern Generator N/A 18 Channels N/A 36 Channels Waveforms Sine, Cosine, Triangle, Rectangle, Sawtooth, Ramp, Pulse, Sinc, Exponential, Sweep, DC, Noise, From File, Arbitrary Waveform Characteristics Sine Waves (Arbitrary) 2 µhz to 125 MHz @ Max Sample Rate (DDS) 3.7 mhz to 110 MHz Amplitude Flatness (1 Vp-p, Typical) DC to 110 MHz (DDS) < ±0.1 db DC to 125 MHz (Arbitrary) < ±0.1 db Harmonics Distortion (1 Vp-p, Typical) 1 MHz < -66 dbc 1 MHz to 5 MHz < -63 dbc 5 MHz to 10 MHz < -59 dbc 10 MHz to 25 MHz < -53 dbc 25 MHz to 75 MHz < -38 dbc 75 MHz to 110 MHz (DDS) < -31 dbc 75 MHz to 125 MHz (Arbitrary) < -28 dbc Non Harmonic Distortion (1 Vp-p, Typical) 1 MHz < -71 dbc 1 MHz to 5 MHz < -71 dbc 5 MHz to 10 MHz < -71 dbc 10 MHz to 25 MHz < -66 dbc 25 MHz to 75 MHz < -53 dbc 75 MHz to 125 MHz (Arbitrary) < -47 dbc 75 MHz to 100 MHz (DDS) < -61 dbc 100 MHz to 110 MHz (DDS) < -30 dbc THD (100 khz, 1 Vp-p, Typical) < 0.15% Phase Noise (20 MHz, 1 Vp-p, Typical) 10 khz Offset -106 dbc / Hz 100 khz Offset -113 dbc / Hz 1 MHz Offset -128 dbc / Hz Analog Bandwidth Arbitrary/DDS 125 MHz / 110 MHz Square Wave, Pulse (1 Vp-p) 2 µhz to 62.5 MHz Duty Cycle Range 1% to 99% Rise/Fall Time, Typical < 3.5 ns Overshoot, Typical < 5.5% Random Jitter (rms, Typical) < 20 ps Triangle 2 µhz to 31.25 MHz Start Phase Range 0 to 360 Ramp 2 µhz to 31.25 MHz Sinc (Sin(x)/x) 2 µhz to 15.5 MHz Minimum Lobe Width 8 ns Waveform Sequencing Waveforms Waveform Repetitions 1 to (2^33 1) Start Source Software, Internal, External No. of Waveforms 1 to 511 Common Characteristics Arbitrary Sample Rate Real Time 4 S/s to 250 MS/s Vertical Resolution 16-bit Waveform Memory 2 Mpts / Ch Minimum Waveform Length 8 points Waveform Resolution 2 points Noise Bandwidth (-3 db Gaussian Noise), Typical 100 MHz Run Modes Single, Continuous, Stepped, Burst Direct Digital Synthesis (DDS) Sample Rate Real Time 125 MS/s to 250 MS/s Run Modes Single, Continuous, Burst Carrier Waveform Memory 2048 Samples / Ch Amplitude, 50 Ω Load (1 khz) 0 V to +12 Vp-p Amplitude, Open Circuit 0 V to +24 Vp-p Amplitude Resolution < 1 mv DC Accuracy, Open Circuit (±12 V Range) ± 0.25% of amplitude range (within ±10 C of calibration temperature T=25 C, Humidity 80%) ± 0.3% of amplitude range (0 to 50 C) DC Accuracy, 50 Ω Load (±6 V Range) ± 0.25% of amplitude range (within ±10 C of calibration temperature T=25 C, Humidity 80%) ± 0.3% of amplitude range (0 to 50 C) 6

SPECIFICATIONS SPECIFICATIONS ArbStudio 1102 ArbStudio 1102D ArbStudio 1104 ArbStudio 1104D Common Characteristics (cont d) AC Accuracy, Open Circuit (0 Vp-p to +24 Vp-p Range, 1 khz Sine Wave) ± 0.25% of amplitude range (within ±10 C of calibration temperature T=25 C, Humidity 80%) ±0.3% of amplitude range (0 to 50 C) AC Accuracy, 50 Ω Load (0 Vp-p to +12 Vp-p Range, 1 khz Sine Wave) ± 0.25% of amplitude range (within ±10 C of calibration temperature T=25 C, Humidity 80%) ±0.3% of amplitude range (0 to 50 C) Output Impedance Selectable: 50 Ω, Low or High Impedance Short Circuit Protection Signal outputs are robust against permanent shorts against floating ground Frequency Accuracy Stability < ± 5 ppm Aging < ± 2 ppm / year Max Interpolated Sample Rate 1 GS/s (4x interpolation) Interpolation Factors 1x, 2x, 4x Sampling Frequency Resolution 15 digits limited by 1 nhz Multi Channel Specifications Sampling Rate Tuning Programmable per channel couple (Ch 1 2) Programmable per channel couple (Ch 1 2, Ch 3 4) Skew Between Channels (at Common Sample Rate) Average (Typical) < 300 ps Standard Deviation (Typical) < 35 ps Math Sum, Difference, Product of Two Channels in a Channel Pair Modulation Amplitude Modulation Modulation Type Carrier Waveform Modulating Waveforms Modulating Source Modulating Waveform Sample Clock at Max. Sampling Rate Memory Size Phase/Frequency Modulation Modulation Type Carrier Waveform Modulating Waveforms Modulating Source Carrier Frequency at Max. Sample Rate Sine Wave Square Triangle Ramp Modulating Waveform Sample Clock at Max. Sample Rate Memory Size Frequency Resolution at 125 MS/s Sample Rate Frequency Resolution at 250 MS/s Sample Rate Pulse Width Modulation Carrier Waveform Carrier Frequency Duty Cycle Modulating Waveform Duty Cycle Modulating Frequency Source Duty Cycle Deviation Frequency Sweep Carrier Waveform Sweep Type Sweep Direction Sweep Range at Max. Sample Rate Sine Wave Square Triangle Ramp Sweep Time at Max. Sample Rate Arbitrary AM, ASK Internal 0.46 S/s to 125 MS/s 2047 entries Arbitrary FM/PM, FSK, PSK Internal 3.7 mhz to 110 MHz 3.7 mhz to 62.5 MHz 3.7 mhz to 31.25 MHz 3.7 mhz to 31.25 MHz From 119.2 S/s to 125 MS/s (per sample programmable) 511 entries 0.0019 Hz (FSK) 2.15E-5 (PSK) 0.0037 Hz (FSK) 4.30E-5 (PSK) Pulse 100 mhz to 20 MHz Sine, Triangle, Ramp, Noise, Manual 10 µhz to 6.67 MHz Internal 0% to 100% of pulse period All waveforms Up or Down 3.7 mhz to 110 MHz 3.7 mhz to 62.5 MHz 3.7 mhz to 31.25 MHz 3.7 mhz to 31.25 MHz 100 ns to 4.2 s Pattern Generator Characteristics Number of Channels N/A 18 N/A 18 / 36 Vector Memory Depth N/A 1 Mpts / Ch (per Ch programmable direction) N/A 1 Mpts / Ch (per Ch programmable direction) Acquisition Memory Depth N/A 2 Mpts / Ch N/A 2 Mpts / Ch Update Frequency N/A 125 MS/s (per Ch programmable direction) N/A 125 MS/s (per Ch programmable direction) Sampling Frequency N/A 250 MS/s N/A 250 MS/s Direction Control N/A Per Ch Programmable N/A Per Ch Programmable Output Voltage Level N/A 1.2 V to 3.6 V 1.2 V to 3.6 V Trigger Levels N/A 31 N/A 31 Operating Modes N/A 18 Ch Digital or 2 Ch Analog N/A 36 Ch Digital or 4 Ch Analog or 18 Ch Digital plus 2 Ch Analog 7

SPECIFICATIONS AND ORDERING SPECIFICATIONS AND ORDERING INFORMATION INFORMATION ArbStudio 1102 ArbStudio 1102D ArbStudio 1104 ArbStudio 1104D Multi-instrument Synchronization Max Number of Instruments N/A N/A Up to 8 units with AS-SYNC cable Synchronization Accuracy N/A N/A < 300 ps Auxiliary Inputs/Outputs External Trigger Output Output Level Output Impedance External Trigger Input Threshold Level Voltage Range Damage Level Slope External Clock Min. Input Voltage Swing Damage Level TTL compatible into > 1 KΩ 50 Ω nominal DC to 125 MHz VILmax = 0.8 V, VIHmin = 2 V -0.5 V to 4 V VINmax < 6 V, VINmin > -2 V Rising Edge or Falling 0 MHz to 125 MHz VINmin > 2 V VINmax < 5 V, VINmin > -5 V General Characteristics Power Supply Voltage Range 100 ±10% to 240 ±10% VAC Power Consumption 35 W max. Power 50/60 Hz ±5% PC Interface USB 2.0 Physical Characteristics External Dimensions (HWD) 2.4" x 12.8" x 7.2" (62 x 326 x 182 mm) Weight 2.8 lbs (1.3 kg) Environmental Characteristics Temperature (Operating) Main equipment: 0 to 50 C Power adapter: 0 to 40 C Temperature (Non-Operating) Main equipment: -40 to 71 C Power adapter: -25 to 71 C Humidity (Operating) 5% to 80% RH (non-condensing) at 30 C, 50% max. RH (non-condensing) at 40 C Humidity (Non-Operating) 5% to 95% max. RH (non-condensing) Altitude (Operating) Up to 3,048 m (10,000 ft) at 30 C Altitude (Non-Operating) Up to 12,192 m (40,000 ft) Minimum PC Requirements Operative System Microsoft Windows 2000/XP SP2/Vista/7 32-bit Editions Processor Intel Pentium III processor, or better Memory 512 MB RAM Hard Disk 150 MB available free space Display Resolution 800 x 600 or better Connectivity USB 2.0 or 1.1 Ordering Information Product Description Product Code 2 Ch 16-bit 1 GS/s Arbitrary Waveform Generator ArbStudio 1102 2 Ch 16-bit 1 GS/s Arbitrary Waveform Generator ArbStudio 1102D and Digital Pattern Generator 4 Ch 16-bit 1 GS/s Arbitrary Waveform Generator ArbStudio 1104 4 Ch 16-bit 1 GS/s Arbitrary Waveform ArbStudio 1104D and Digital Pattern Generator ArbStudio Sync Cable for ArbStudio 1104 and 1104D AS-SYNC Customer Service LeCroy oscilloscopes and probes are designed, built, and tested to ensure high reliability. In the unlikely event you experience difficulties, our digital oscilloscopes are fully warranted for three years and our probes are warranted for one year. This warranty includes: No charge for return shipping Long-term 7-year support Upgrade to latest software at no charge 1-800-5-LeCroy www.lecroy.com Local sales offices are located throughout the world. Visit our website to find the most convenient location. 2010 by LeCroy Corporation. All rights reserved. Specifications, prices, availability, and delivery subject to change without notice. Product or brand names are trademarks or requested trademarks of their respective holders. ArbStudioDS-04Jun10 PDF