PCB Power elay ow-profile.3 mm height power relay with maximum switching of 0A ow profile:.3 mm in height Max. switching capacity:,00 VA (NO) Dielectric strength: kv Clearance and creepage distance: 0 mm. Models with high shock resistance (0 m/s ) are available. Models for P load ( x 00 W lamps parallel to ignition transformer) are available. ohs Compliant Model Number egend Application Examples -@ @ @ - @ - @ 3 4. Number of Poles : -pole. Contact Form None: A: 4. Contact material None: Standard (Ag-alloy, Cd free) ASI: AgSnIn. Special Functions P: P load Boilers PCs I/O ports Timers Temperature controllers 3. Enclosure rating None: Flux protection 4: Fully sealed Ordering Information Classification Terminal Shape Contact form Enclosure rating Model ated coil voltage Minimum packing unit -A Standard Flux protection -A-ASI 3 VDC P oad -A-ASI-P VDC Fully sealed -A4-ASI VDC PCB terminals pcs/tray Standard - VDC Flux protection --ASI 4 VDC P oad --ASI-P 48 VDC Standard Fully sealed -4-ASI Note. When ordering, add the rated coil voltage to the model number. Example: -A DC3 ated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@VDC. atings Coil Standard, P oad (-P type) ated Voltage (VDC) ated current (ma) Coil resistance (Ω) Must operate voltage Must release voltage % of rated voltage Note. The rated current and coil resistance are measured at a coil temperature of 3 C with a tolerance of ±0%. Note. The operating characteristics are measured at a coil temperature of 3 C. Note 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. Max. voltage Power consumption (mw) 3 73.3 40 44 3 3.7 3 0% Approx. 0 70% max. 0% min. 8.3 4 (at 3 C) 4 9. 8 48 900 Approx. 40
PCB Power elay Contacts Contacts type Contacts material ated load * ated carry current oad Max. switching current Single * -(A), -(A)4-ASI: 8 A 0 VAC, resistive load; A 4 VDC resistive load. Characteristics Ag-alloy (Cd free) esistive load 0 A at 0 VAC, (NO) resistive load 8 A at 0 VAC, resistive load A at 30 VDC, resistive load 0 A NO: 0 A, NC: 8 A Contact resistance * Operate time elease time Insulation resistance * Dielectric strength Between coil and contacts mω max. 0 ms max. ms max.,000 Ω min.,000 VAC, 0/0 Hz for min Between contacts of the same polarity,000 VAC, 0/0 Hz for min Impulse withstand voltage Between coil and contacts 0kV (. 0μs) Insulation distance Between coil and contacts Clearance: 0 mm, Creepage: 0 mm Vibration resistance Shock resistance Endurance Destruction 0 to to 0 Hz, 0.7 mm single amplitude (. mm double amplitude) Malfunction 0 to to 0 Hz, 0.8 mm single amplitude (. mm double amplitude) when energized 0 to to 0 Hz, mm single amplitude (0.8 mm double amplitude) when de-energized. Destruction,000 m/s Malfunction NO: 00 m/s, NC: 0 m/s Mechanical Electrical Failure rate (P level) (reference value) *3 Ambient operating temperature 0,000,000 operations min. (at 8,000 operations/h) -(A) 0,000 operations min. (NO) at 0 VAC, 8A (resistive load) 0,000 operations min. (NC) at 0 VAC, 8A (resistive load) 0,000 operations min. at 4 VDC, A (resistive load) (at 00 operations/h) -(A)-ASI-(P),000 operations min. (NO) at 0 VAC, 0A (resistive load),000 operations min. at 0 VAC, 8A (resistive load) 0,000 operations min. at 30 VDC, A (resistive load) (at,800 operations/h) -(A)4-ASI 0,000 operations min. (NO) at 0 VAC, 8A (resistive load) 0,000 operations min. (NC) at 0 VAC, 8A (resistive load) 0,000 operations min. at 4 VDC, A (resistive load) (at,800 operations/h) 0 ma at VDC Ambient operating humidity % to 8% Weight -40 C to 8 C (with no icing or condensation) Approx. 7.8 g Note. The given values are initial values. *. Measurement conditions: VDC, A, voltage drop method. *. Measurement conditions: The insulation resistance was measured with a 00 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. This value was measured at a switching frequency of 0 operations/min.
Engineering Data -(A)(4)-(ASI)-(P) Maximum Switching Capacity Switching current (A) 0 0 0. DC resistive load AC resistive load (N.O.) AC resistive load (N.C.) -(A) Durability No. of operation (x0 3 ),000 00 300 0 30 4 VDC resistive load 0 VAC inductive load (cos φ = ) 0 VAC resistive load (N.O.) PCB Power elay -(A)(4)-(ASI)-(P) Ambient Temperature vs. Maximum Coil Voltage Maximum coil voltage (%) 00 80 0 0 40 0 80 -(0 mw) 0. 3 0 30 0 300 00,000 -(A)(4) Ambient Temperature vs. Must Operate or Must elease Voltage On the basis of rated voltage (%) 0 80 0 40 0 Sample: 4 VDC Number of relays: pcs Dimensions Switching voltage Must operate voltage Must release voltage max. min. max. min. 0 40 0 0 0 40 0 80 -A -A-ASI -A4-ASI Ambient temperature ( C) 0 0 4 8 0 -(A)(4)-(ASI)-(P) Shock Malfunction X Z Y NC contact 98 Y 94 8. max. 0.0 max. Unit: m/s Switching current (A) NO contact Z X 0-40 0 3 30 40 0 0 70 80 90 Ambient temperature ( C) Note The "maximum coil voltage" is the maximum voltage that can be applied to the elay coil. Sample: - 4 VDC Number of elays: pcs Test Conditions: The value at which malfunction occurred was measured after applying shock to the test piece 3 times each in directions along 3 axes. Standard value: 00m/s (NO) 0m/s (NC) Shock direction X X Y Z Z Y PCB Mounting Holes (.9) 8.9±0. ±0. (.7) (Unit: mm) Terminal Arrangement/Internal Connections 3 0.8 0.8 3..3 max. Four,.3±0. dia. holes 7.±0. (Indicates average dimensions.) - --ASI -4-ASI 8. max. 0.0 max. PCB Mounting Holes (.) 8.9±0. 3.±0. 3.±0. (.7) Terminal Arrangement/ Internal Connections 4 3 0.8 0.8 3..3 max. Five,.3±0. dia. holes 7.±0. (Indicates average dimensions.) 3
PCB Power elay Approved Standards The approval ratings for overseas models are different from the performance values determined individually. Confirm the values before use. U ecognized: (File No. E443) Models Contact from Coil ratings Contact ratings Number of test operations -A - 0 A, 0 VAC (NO) (esistive) 8 C 3 to 48 VAC 8 A, 0 VAC (esistive) 8 C,000 -A(4)-ASI A, 30 VDC (esistive) 8 C -(4)-ASI EN/IEC, VDE Certified: (EN80-) (Certificate No. C) Models Contact from Coil ratings Contact ratings Number of test operations -A-(ASI) 0 A, 0 VAC (NO) 8 C 0,000 --(ASI) 3,,,, 4, 48 VDC 8 A, 0 VAC 8 C 30,000 A, 30 VDC 8 C 0,000 -A4-ASI 0 A, 0 VAC (NO) 8 C -4-ASI 3,,,, 4, 48 VDC 8 A, 0 VAC 8 C 0,000 A, 30 VDC 8 C EN/IEC, VDE Certified: (EN 0947--) (Certificate No. C) Models Contact ratings Number of test operations AC (NO) AC40, 3 A, cos ϕ 0.3, oom temperaure -(A)(4) DC3 DC, 0.A, ms, oom temperaure DC3 DC0, 0.A, 0ms, oom temperaure AC AC40, 3 A, cos ϕ 0.3, oom temperaure -(A)-ASI DC3 DC, 0.A, ms, oom temperaure,000 DC3 DC0, 0.A, 0ms, oom temperaure -(A)4-ASI AC AC40, 3 A, cos ϕ 0.3, oom temperaure DC3 DC, 0.A, ms, oom temperaure EN/IEC, VDE (0947-4-) (Certificate No. C) -(A) -(A)-ASI EN/IEC, VDE (EN0730-) (Certificate No. 400033) -(A) -(A)-ASI EN/IEC Models Contact ratings Number of test operations AC AC0V 8 A 8 C AC3 AC0V A 8 C DC DC4V A 8 C DC3 DC4V A 8 C Models Coil ratings Contact ratings Number of test operations 3,,,, 4, 48 VDC () A AC0V C (4) A (NC) AC0V C 8 (4) A (NO) AC0V 8 C () A AC0V C (4) A (NC) AC0V C 8 (4) A (NO) AC0V 8 C Note. Basic requirements of EMC directives (EMI standard No., EMS standard No., Certification Body, File No., Applicable time) not applicable.,000,000 Basic equirements of Machinery Directive/ow-voltage Directive Models CE Marking Applicable Safety Category Applicable Standard No. Application Standard No. EN80- Creepage distance Clearance distance Insulation material group ated Insulation Voltage Pollution degree 3 ated voltage system 0 V 400 V Overvoltage category III II Tracking Index of relay base 0 mm 0 mm IIIa 0 V PTI 0 V min. (housing parts) Flammability class according to U94 V-0 Ball pressure test (IEC 09-0-) 70 C 4
PCB Power elay Precautions Please refer to "PCB elays Common Precautions" for correct use. Correct Use The are net intended to be used in automotive applications (including two wheel vehicles). If the product is used in the following applications, consult your OMON sales representative to check the necessary items according to the specification sheets. Also make sure the product is used within the specified ratings and performance ranges with an ample margin and implement safety measures, such as designing a safety circuit, to minimize danger should the product fail. a. Outdoor use, uses involving potential chemical contamination or electrical interference. b. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, safety equipment, and equipment that could present a risk to human life or body. c. Equipment requiring a high level of reliability, such as gas, water, or electrical supply systems. Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K33-E-07 03(007)(O)