4. Contact material None: Standard (Ag-alloy, Cd free) ASI: AgSnIn 5. Special Functions PL: P1 load

Similar documents
Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Model Number Legend. Application Examples. Surface Mounting Relay

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

CQM1-SF200/CS1W-SF200

Model Number Structure

Surface Mounting Relay

Model Number Structure

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

RY2 miniature industrial relays

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

Tactile Switch B3F Through-hole-mounting Switches in a Wide Range of Models: 6 6 mm, 12

Goodsky Technical Data. Contact Details

Surface Mounting Relay

Pluggable interface relays CR-P Pcb relays

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

RM4TG20 three-phase network control relay RM4-T - range V

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

AZ420 MINIATURE GENERAL PURPOSE RELAY

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

General-purpose Relay

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

2 POLES - 5A LOW PROFILE TYPE

40 Series - Miniature PCB/Plug-in relays A. Features

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

How To Read A Pipe From A Sensor

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

60 Series - General purpose relays 6-10 A. Features

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

48 SERIES Relay interface modules 10 A

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Liquid Leakage Sensor Amplifier

1a/1c 5A/10A small power relays

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

38 Series - Relay interface modules A

FP2 Relay. The Best Relaytion

2 POLES 1 to 2 A (FOR SIGNAL SWITCHING)

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

38 Series - Relay interface modules A

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

1 POLE - 8A Medium Load Control

SKR - industry relay

49 Series - Relay interface modules A. Features

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

Type: DILM9 10(24VDC) Article No.:

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

LOW PROFILE 2 FORM C RELAY mm inch. M.B.B.type. Initial breakdown voltage 1 A 30 V DC 30 W, 62.5 V A 30 W.

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

1 POLE - 5A SLIM POWER RELAY

Type: DILM32 10(24V50HZ) Article No.:

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

DS 600. A contact free flux gate based current measurement sensor 600A rms

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

General-purpose Relays

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Safety technique. Emergency stop module BO 5988 safemaster

Safety Manual BT50(T) Safety relay / Expansion relay

Features. Type List 832A

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type Terminal Coil Contact form Model

Product Catalogue. Relays with forcibly guided contacts

Signal Relays AXICOM. P2 Relay V AXICOM Telecom-, Signal and RF Relays. P2 V23079 Relay. Coil Operating Range. Coil Data

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

Solid-State Timer H3G

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

NX safety stand-alone

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

Long sensing range. Most suitable for conveyor lines and parking lot applications. 10 m ft (Red LED)

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

Catalog. Modular DIN rail components Installation contactors

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Transcription:

PCB Power elay ow-profile.3 mm height power relay with maximum switching of 0A ow profile:.3 mm in height Max. switching capacity:,00 VA (NO) Dielectric strength: kv Clearance and creepage distance: 0 mm. Models with high shock resistance (0 m/s ) are available. Models for P load ( x 00 W lamps parallel to ignition transformer) are available. ohs Compliant Model Number egend Application Examples -@ @ @ - @ - @ 3 4. Number of Poles : -pole. Contact Form None: A: 4. Contact material None: Standard (Ag-alloy, Cd free) ASI: AgSnIn. Special Functions P: P load Boilers PCs I/O ports Timers Temperature controllers 3. Enclosure rating None: Flux protection 4: Fully sealed Ordering Information Classification Terminal Shape Contact form Enclosure rating Model ated coil voltage Minimum packing unit -A Standard Flux protection -A-ASI 3 VDC P oad -A-ASI-P VDC Fully sealed -A4-ASI VDC PCB terminals pcs/tray Standard - VDC Flux protection --ASI 4 VDC P oad --ASI-P 48 VDC Standard Fully sealed -4-ASI Note. When ordering, add the rated coil voltage to the model number. Example: -A DC3 ated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@VDC. atings Coil Standard, P oad (-P type) ated Voltage (VDC) ated current (ma) Coil resistance (Ω) Must operate voltage Must release voltage % of rated voltage Note. The rated current and coil resistance are measured at a coil temperature of 3 C with a tolerance of ±0%. Note. The operating characteristics are measured at a coil temperature of 3 C. Note 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. Max. voltage Power consumption (mw) 3 73.3 40 44 3 3.7 3 0% Approx. 0 70% max. 0% min. 8.3 4 (at 3 C) 4 9. 8 48 900 Approx. 40

PCB Power elay Contacts Contacts type Contacts material ated load * ated carry current oad Max. switching current Single * -(A), -(A)4-ASI: 8 A 0 VAC, resistive load; A 4 VDC resistive load. Characteristics Ag-alloy (Cd free) esistive load 0 A at 0 VAC, (NO) resistive load 8 A at 0 VAC, resistive load A at 30 VDC, resistive load 0 A NO: 0 A, NC: 8 A Contact resistance * Operate time elease time Insulation resistance * Dielectric strength Between coil and contacts mω max. 0 ms max. ms max.,000 Ω min.,000 VAC, 0/0 Hz for min Between contacts of the same polarity,000 VAC, 0/0 Hz for min Impulse withstand voltage Between coil and contacts 0kV (. 0μs) Insulation distance Between coil and contacts Clearance: 0 mm, Creepage: 0 mm Vibration resistance Shock resistance Endurance Destruction 0 to to 0 Hz, 0.7 mm single amplitude (. mm double amplitude) Malfunction 0 to to 0 Hz, 0.8 mm single amplitude (. mm double amplitude) when energized 0 to to 0 Hz, mm single amplitude (0.8 mm double amplitude) when de-energized. Destruction,000 m/s Malfunction NO: 00 m/s, NC: 0 m/s Mechanical Electrical Failure rate (P level) (reference value) *3 Ambient operating temperature 0,000,000 operations min. (at 8,000 operations/h) -(A) 0,000 operations min. (NO) at 0 VAC, 8A (resistive load) 0,000 operations min. (NC) at 0 VAC, 8A (resistive load) 0,000 operations min. at 4 VDC, A (resistive load) (at 00 operations/h) -(A)-ASI-(P),000 operations min. (NO) at 0 VAC, 0A (resistive load),000 operations min. at 0 VAC, 8A (resistive load) 0,000 operations min. at 30 VDC, A (resistive load) (at,800 operations/h) -(A)4-ASI 0,000 operations min. (NO) at 0 VAC, 8A (resistive load) 0,000 operations min. (NC) at 0 VAC, 8A (resistive load) 0,000 operations min. at 4 VDC, A (resistive load) (at,800 operations/h) 0 ma at VDC Ambient operating humidity % to 8% Weight -40 C to 8 C (with no icing or condensation) Approx. 7.8 g Note. The given values are initial values. *. Measurement conditions: VDC, A, voltage drop method. *. Measurement conditions: The insulation resistance was measured with a 00 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. This value was measured at a switching frequency of 0 operations/min.

Engineering Data -(A)(4)-(ASI)-(P) Maximum Switching Capacity Switching current (A) 0 0 0. DC resistive load AC resistive load (N.O.) AC resistive load (N.C.) -(A) Durability No. of operation (x0 3 ),000 00 300 0 30 4 VDC resistive load 0 VAC inductive load (cos φ = ) 0 VAC resistive load (N.O.) PCB Power elay -(A)(4)-(ASI)-(P) Ambient Temperature vs. Maximum Coil Voltage Maximum coil voltage (%) 00 80 0 0 40 0 80 -(0 mw) 0. 3 0 30 0 300 00,000 -(A)(4) Ambient Temperature vs. Must Operate or Must elease Voltage On the basis of rated voltage (%) 0 80 0 40 0 Sample: 4 VDC Number of relays: pcs Dimensions Switching voltage Must operate voltage Must release voltage max. min. max. min. 0 40 0 0 0 40 0 80 -A -A-ASI -A4-ASI Ambient temperature ( C) 0 0 4 8 0 -(A)(4)-(ASI)-(P) Shock Malfunction X Z Y NC contact 98 Y 94 8. max. 0.0 max. Unit: m/s Switching current (A) NO contact Z X 0-40 0 3 30 40 0 0 70 80 90 Ambient temperature ( C) Note The "maximum coil voltage" is the maximum voltage that can be applied to the elay coil. Sample: - 4 VDC Number of elays: pcs Test Conditions: The value at which malfunction occurred was measured after applying shock to the test piece 3 times each in directions along 3 axes. Standard value: 00m/s (NO) 0m/s (NC) Shock direction X X Y Z Z Y PCB Mounting Holes (.9) 8.9±0. ±0. (.7) (Unit: mm) Terminal Arrangement/Internal Connections 3 0.8 0.8 3..3 max. Four,.3±0. dia. holes 7.±0. (Indicates average dimensions.) - --ASI -4-ASI 8. max. 0.0 max. PCB Mounting Holes (.) 8.9±0. 3.±0. 3.±0. (.7) Terminal Arrangement/ Internal Connections 4 3 0.8 0.8 3..3 max. Five,.3±0. dia. holes 7.±0. (Indicates average dimensions.) 3

PCB Power elay Approved Standards The approval ratings for overseas models are different from the performance values determined individually. Confirm the values before use. U ecognized: (File No. E443) Models Contact from Coil ratings Contact ratings Number of test operations -A - 0 A, 0 VAC (NO) (esistive) 8 C 3 to 48 VAC 8 A, 0 VAC (esistive) 8 C,000 -A(4)-ASI A, 30 VDC (esistive) 8 C -(4)-ASI EN/IEC, VDE Certified: (EN80-) (Certificate No. C) Models Contact from Coil ratings Contact ratings Number of test operations -A-(ASI) 0 A, 0 VAC (NO) 8 C 0,000 --(ASI) 3,,,, 4, 48 VDC 8 A, 0 VAC 8 C 30,000 A, 30 VDC 8 C 0,000 -A4-ASI 0 A, 0 VAC (NO) 8 C -4-ASI 3,,,, 4, 48 VDC 8 A, 0 VAC 8 C 0,000 A, 30 VDC 8 C EN/IEC, VDE Certified: (EN 0947--) (Certificate No. C) Models Contact ratings Number of test operations AC (NO) AC40, 3 A, cos ϕ 0.3, oom temperaure -(A)(4) DC3 DC, 0.A, ms, oom temperaure DC3 DC0, 0.A, 0ms, oom temperaure AC AC40, 3 A, cos ϕ 0.3, oom temperaure -(A)-ASI DC3 DC, 0.A, ms, oom temperaure,000 DC3 DC0, 0.A, 0ms, oom temperaure -(A)4-ASI AC AC40, 3 A, cos ϕ 0.3, oom temperaure DC3 DC, 0.A, ms, oom temperaure EN/IEC, VDE (0947-4-) (Certificate No. C) -(A) -(A)-ASI EN/IEC, VDE (EN0730-) (Certificate No. 400033) -(A) -(A)-ASI EN/IEC Models Contact ratings Number of test operations AC AC0V 8 A 8 C AC3 AC0V A 8 C DC DC4V A 8 C DC3 DC4V A 8 C Models Coil ratings Contact ratings Number of test operations 3,,,, 4, 48 VDC () A AC0V C (4) A (NC) AC0V C 8 (4) A (NO) AC0V 8 C () A AC0V C (4) A (NC) AC0V C 8 (4) A (NO) AC0V 8 C Note. Basic requirements of EMC directives (EMI standard No., EMS standard No., Certification Body, File No., Applicable time) not applicable.,000,000 Basic equirements of Machinery Directive/ow-voltage Directive Models CE Marking Applicable Safety Category Applicable Standard No. Application Standard No. EN80- Creepage distance Clearance distance Insulation material group ated Insulation Voltage Pollution degree 3 ated voltage system 0 V 400 V Overvoltage category III II Tracking Index of relay base 0 mm 0 mm IIIa 0 V PTI 0 V min. (housing parts) Flammability class according to U94 V-0 Ball pressure test (IEC 09-0-) 70 C 4

PCB Power elay Precautions Please refer to "PCB elays Common Precautions" for correct use. Correct Use The are net intended to be used in automotive applications (including two wheel vehicles). If the product is used in the following applications, consult your OMON sales representative to check the necessary items according to the specification sheets. Also make sure the product is used within the specified ratings and performance ranges with an ample margin and implement safety measures, such as designing a safety circuit, to minimize danger should the product fail. a. Outdoor use, uses involving potential chemical contamination or electrical interference. b. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, safety equipment, and equipment that could present a risk to human life or body. c. Equipment requiring a high level of reliability, such as gas, water, or electrical supply systems. Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMON Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb Cat. No. K33-E-07 03(007)(O)