SANUPS POWER MANAGEMENT SOFTWARE SANUPS SOFTWARE



Similar documents
Network Management Card. User Manual

Intelligent Power Protector User manual extension for Microsoft Virtual architectures: Hyper-V 6.0 Manager Hyper-V Server (R1&R2)

Communication and connectivity the ideal solution for integrated system management and data integrity

Dell UPS Local Node Manager USER'S GUIDE EXTENSION FOR MICROSOFT VIRTUAL ARCHITECTURES Dellups.com

Secure Power Always. Agility Series UPS ( VA) Chloride Connectivity Solutions. Product data sheet

Installation and Configuration User's Guide

PowerPanel Business Edition USER MANUAL

Eaton NetWatch v5.0 NetWatch on Microsoft Hyper-V server 2008 Installation and configuration guide

HP UPS Management Module Overview

PN5212/PN5320/PN7212/PN7320

QuickSpecs. Models. HP UPS Management Module. HP UPS Management Module. Overview

PE6108/PE6208/PE8108/PE8208

User and Installation Manual

Gigabyte Content Management System Console User s Guide. Version: 0.1

Chapter 3 Startup and Shutdown This chapter discusses how to startup and shutdown ETERNUSmgr.

How To Set Up Power Supply On Windows (Windows) With Powerup (Windows 8) On Windows 7.1) On A Pc Or Windows 8 (Windows 7) On An Ipad Or Ipad (Windows Xp

Overview of ServerView Windows Agent This chapter explains overview of ServerView Windows Agent, and system requirements.

Sentry Bulldog Shutdown Management Software (For UNIX Series)

UPS MANAGEMENT SOFTWARE

SNMP-SSL UPS SNMP Card (Web-Based monitoring SNMP Card) User s Manual

SNMP Web card. User s Manual. Management Software for Uninterruptible Power Supply Systems

,QVLJKW3RZHU 6103,3Y IRU

Description UPS Management Software

Job Management Partner 1/Performance Management - Remote Monitor for Virtual Machine Description, User's Guide and Reference

UPS MANAGEMENT SOFTWARE OPTIONS

Connectivity. PowerShield 3. Communications Software

Liebert MultiLink. User Manual - Fundamental & Advanced

Dell Network Management Card. User's Guide. w w w. d e l l. c o m s u p p o r t. d e l l. c o m

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

Network Management Proxy 5 User manual

Table of Contents. 1. Introduction PDU Package Function Installation Web Interface...7

NEC Express5800 Series NEC ESMPRO AlertManager User's Guide

Remote Supervisor Adapter II. User s Guide

OnCommand Performance Manager 1.1

Extreme Control Center, NAC, and Purview Virtual Appliance Installation Guide

Contents. Preparation/SetUp...2

Ambient Temperature In Range Probe X

UPS Management Software

C p o y p r y i r g i h g t D t e a t i a lie l d

Software and accessories

WebPower UPS SNMP HTTP AGENT

Network-Enabled Devices, AOS v.5.x.x. Content and Purpose of This Guide...1 User Management...2 Types of user accounts2

Important. Please read this User s Manual carefully to familiarize yourself with safe and effective usage.

Gigabyte Management Console User s Guide (For ASPEED AST 2400 Chipset)

User's Guide. System Monitor - Performance Monitoring Services 5.0

Whitepaper. Business Service monitoring approach

SNMP INTERFACES AND SOFTWARE FOR SINGLE-PHASE UPS

OnCommand Performance Manager 1.1

Minislot Transverse Environment Sensor 66846

Dominion PX. General Questions. What is Dominion PX (PX)?

Heroix Longitude Quick Start Guide V7.1

Environment Sensor

Ahsay Replication Server v5.5. Administrator s Guide. Ahsay TM Online Backup - Development Department

Chapter 8 Router and Network Management

PE8216/PE8324. Energy Intelligence Solutions

SecureVault Online Backup Service FAQ

Network Management Card Wizard--1. Introduction... 1 Using the Network Management Card Wizard... 5

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

SapphireIMS Business Service Monitoring Feature Specification

Network Power Manager. User Manual

User s Manual Network Management Card

User s Manual UPS SERIES. Network Interface Card UPS-IPCARD. I Rev B

Introducing ZENworks 11 SP4. Experience Added Value and Improved Capabilities. Article. Article Reprint. Endpoint Management

Verax Service Desk Installation Guide for UNIX and Windows

NetCrunch 6. AdRem. Network Monitoring Server. Document. Monitor. Manage

Centers for Medicare and Medicaid Services. Connect: Enterprise Secure Client (SFTP) Gentran. Internet Option Manual

To manually install the Java Console, see the Release Notes in the Utility directory of this software distribution.

HP A-IMC Firewall Manager

Detailed Features. Detailed Features. EISOO AnyBackup Family 1 / 19

Dell UPS Local Node Manager. User Guide. Dell.com

ViewPower. User s Manual. Management Software for Uninterruptible Power Supply Systems

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

SOSFTP Managed File Transfer

SIP Proxy Server. Administrator Installation and Configuration Guide. V2.31b. 09SIPXM.SY2.31b.EN3

Network Management Card. User Manual

Eaton NetWatch NetWatch installation and configuration guide VMware ESX 3 Virtual architecture

EPICenter Network Management Software

Technical Overview CM-16 Climate Monitor. Get yours direct at:

Datasheet Fujitsu CELVIN NAS Server Q700

UPS Communicator. UPS Communicator English Manual Release

UPS Monitoring Software. User manual Borri Power Guardian

Introducing Tripp Lite s PowerAlert Network Management Software

User s Guide. SNMPWEBCARD Firmware Version through Revision A

Performance Monitoring User s Manual

SNMP Monitoring and SWG MIB

SapphireIMS 4.0 BSM Feature Specification

Remote Management Card

How to Log On Main Screen Control Console Menus How to Log On Summary Page Navigation Menu... 29

User s Manual PowerPanel Shutdown Service Graceful Shutdown and Notification service to ensure power protection of your computer

PowerChute Network Shutdown v4.1 Release Notes

User s Manual. Remote Management Card

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Release Notes for RingMaster Version

There are many different ways in which we can connect to a remote machine over the Internet. These include (but are not limited to):

Introducing ZENworks 11 SP4

Quick Setup Guide. 2 System requirements and licensing Kerio Technologies s.r.o. All rights reserved.

RES ONE Automation 2015 Task Overview

This chapter explains a preparation for the use of RemoteControlService.

Install / Users Guide

Transcription:

SANUPS POWER MANAGEMENT SOFTWARE SANUPS SOFTWARE

Enhanced Electrical Management UPS is adopted to protect valuable systems and data from power failures and other electrical power problems used various situations. However, it is impossible to provide an unlimited power since UPS battery capacity is limited. When the system did not normally shut down at power outage, this may cause trouble on connection devices. UPS Management Software automatically shuts down the system in case of power failures, and stops UPS. This software allows smooth and safe management of data and systems. Monitoring of the UPS status, scheduled operation, status monitoring via networks, control, and other functions can work flexibly. UPS Management Software This software automatically shuts down the system and stops the UPS when a failure occurs in the commercial power supply. Smooth power management is still ensured even when the UPS is connected to many computers. Also, control of the power supply and automatic operation of the computer using the schedule function can work. UPS Monitoring Software SANUPS IT Monitor Manager It is a software application that monitors, manages, and controls multiple target devices connected to a network in a consolidated way. UPS Option Interface Card This interface card allows UPS units to directly connect to. It monitors and reports on power supply status, takes quick action in case of a power failures and other malfunction, and informs the system administrator via E-mail on any power problems. Support for SSH (Secure SHell). * Ambient temperature and humidity can be measured by connecting the corresponding sensors. * SSH (Secure SHell) is a program, generally used on Linux computers, to allow logging in to a second computer via a network and working commands and other operations. Since data transmitted over the network is encrypted, a sequence of operations work safety even over the Internet. Support for SSH Version: SSH Version 2 When shutting down devices connected via SSH, the time taken to log in using the SSH verification method may differ. When using host verification or public key verification, it may take longer to log in. 1

for the Entire System Example of UPS Management Software Introduction Remote Terminal Router UPS Serial Linux UPS Serial Windows Serial Windows UPS Windows UNIX Linux Humidity sensor Temperature sensor Interface Card Windows IT Monitor Manager UPS UPS Monitoring Software IT Monitor Manager UPS Options Interface Card Functions Web browser support functions, UNIX and Linux support functions Strengthened network support functions, E-mail transmission functions Strengthened security, Temperature and Humidity Monitor UPS Management Software 2

UPS Management Software This software automatically shuts down the system and stops the UPS when a failure occurs in the commercial power supply. Smooth power management is still ensured even when the UPS is connected to many computers. Flexible Supply Management When you set automatic start-up at power recovery, it can also be set not to automatically start-up until the battery charge reaches a pre-set amount. It can automatically shut down the UPS in the event of a major malfunction and overload. Easy Maintenance Maintenance is easily done from Telnet and a Web browser, and monitoring is also easily done via E-mail. Battery replacement time and alarm on major malfunction is sent via E-mail to ensure the next action. The battery test result is sent via E-mail. Multiple Interfaces Shutdown through Telnet connection Wake On, SNMP, DHCP, and DNS Flexible UPS connection interfaces (serial, contact, and ) Supported Operating Systems for Windows Windows 2000 Windows XP (x86 / x64) Windows Server 2003 (x86 / x64 / IA-64) Windows Server 2003 R2 (x86 / x64) Windows Vista (x86 / x64) Windows Server 2008 (x86 / x64 / IA-64) Windows Web Server 2008 (x86 / x64) Windows Server 2008 R2 (x64) Windows Web Server 2008 R2 (x64) Windows 7 (x86 / x64) Windows 8 (x86 / x64) Windows Server 2012 (x64) for UNIX Solaris 8 / 9 / 10 / 11 (SPARC) Solaris10 / 11 (x86) AIX 5.1 / 5.2 / 5.3 / 6.1 / 7.1 HP-UX 11i v1 HP-UX 11i v2 for Itanium / v3 for Itanium for Linux Red Hat Enterprise Linux v.3 / v.4 / v.5 / v.6 (x86 / x64 / IA-64) SUSE Linux Enterprise Server 9 / 10 / 11 (x86 / x64) Turbolinux 10 Server (x86 / x64) MIRACLE LINUX V4.0 (x86 / x64) MIRACLE LINUX Asianux Server 3 (x86 / x64) VMWare ESX Server 3.0 / 3.5 / 4.0 / 4.1 Model Ver.2.0.1 Windows version PMS40H00E (Without cable) PMS40H00E-10 (Without cable, 10 License) PMS40H00E-50 (Without cable, 50 License) PMS40H00E-100 (Without cable, 100 License) PMS40H01E (With cable) Multi-OS version PMS41H00E (Without cable) PMS41H00E-10 (Without cable, 10 License) PMS41H00E-50 (Without cable, 50 License) PMS41H00E-100 (Without cable, 100 License) PMS41H01E (With cable) 3

Automatic Computer Shutdown Functions 1. Multiple Shutdown Functions Computer is automatically shut down in the event of power outages and other power malfunctions. Computer is also shut down when major malfunction, overload, and serial transmission failure occurs. Type of shutdown is selectable (for Windows version only). Shutdown Shutdown and Automatic Computer down Standby 2. Support for Multiple Platforms Supports mixed different OS platforms (Windows, UNIX, and Linux) and allows to shutdown up to 50 machines. Regarding UNIX, Linux, and FreeBSD, shutdown control is also available by logging onto Telnet. 3. Execution of User Command Executes commands specified by user before shutting down the operating system. Application shutdown functions (command provided for Windows version only) Running applications* can be automatically saved and shutdown. *Products related to Microsoft Office 2000, XP, 2003, 2007, and 2010 (Word, Excel, Point, FrontPage, Project, and Visio) 4. Automatic UPS Start-up on Recovery Automatic UPS start-up is available at power recovery caused by power failure. The battery charge level can be set when the UPS is automatically restarted after power has been restored (varies depending on UPS models). can be turned on for the computers that support WakeOn. *Automatic computer startup when starting UPS power supply relies on the actual computer specifications. 5. Scheduled Operation Functions Scheduled operation for UPS output as ON and OFF can be done once per day. The computer is automatically shut down before UPS is stopped. *Automatic computer startup at starting up UPS power supply relies on the actual computer specifications. Shutdown Sequence Commercial power Momentary blackout failure restored UPS status Normal Battery power supply Normal Battery power supply Normal Automatic UPS startup Automatic UPS stop SANUPS SOFTWARE Waits for recovery of power failure confirmation time Waits for recovery of power failure confirmation time Carries out user commands prior to activating shutdown Shutdown delaying time Carries out shutdown After shutting down, automatically stops the UPS UPS automatic stopping time *The timing for the shutting down of each server can be changed. Status Monitoring 1. UPS Status Display Input and output power status and battery status can be monitored in real time UPS status is recorded as archive and displayed at each event such as power outages, and at specified time intervals. 2. Support for Web Browsers and Telnet Remote status check and setting change can be done through a web browser and Telnet terminal. *The web browser must be Java-enabled. 3. SNMP Agent Functions The function supports RFC1628 standard UPS-MIB. Status of UPS is monitored from SNMP manger. 4. E-mail Transmission and Reception Functions Any changes (power failures etc) occurring in UPS can be notified via E-mail. UPS status can be acquired by sending a request mail 5. Sound Notification (Only applies to Windows version) A sound file can be executed when displaying message screens at power failures. 4

UPS Monitoring Software IT Monitor Manager This software combines monitoring, managing and control of multiple networked Sanyo Denki UPSs. Centralized monitoring of multiple devices Uses SNMP (Simple Network Management Protocol) to remotely monitor and manage up to 500 Sanyo Denki UPSs. Displays real-time device status. Device fault history is saved and displayed in a system log. Check log information such as fault occurrences and recoveries, and SNMP traps. Use the real-time display function to check the status of each device. Control is also available. Record and display the history of states and measured values collected within a specified confirmation interval. When a device fault occurs, you can be notified by a pop-up message or e-mail. A batch file can also be executed on the server. Supported Operating Systems for Windows Windows NT 4.0 Windows 2000 Windows XP (x86 / x64) Windows Server 2003 (x86 / x64) Windows Server 2003 R2 (x86 / x64) Windows Vista (x86 / x64) Windows Sever 2008 (x86 / x64) Windows Sever 2008 R2 (x64) Windows 7 (x86 / x64) Model English Version Chinese Version PMS34C00E PMS34C00C Fig.1 Fig.2 Centrally confirm the status of devices. Icon color changes according to device status (Fig.1). Use the status and measurement value history display function to view device status history. The history can also be saved as a file (Fig.2). 5

UPS Option Interface Card This interface card allows UPS units to directly connect to. It monitors and reports on power supply status, takes quick action in case of a power failure and other malfunction, and informs the system administrator via E-mail on any power problems. Support for SSH (Secure SHell). Line up Model: PRIF003/004 Compared with our conventional products, this model provides enhanced security and compatibility with redundant power supply systems. Model: PRIF005/006 This model includes the functions of the PRIF003/004, and adds the capability to monitor UPS ambient temperature and humidity utilizing temperature and humidity sensors. Model Interface Card Model Supported UPS PRIF003-US A11H/A11J/E11A/A11F102/A11F152 PRIF004-US A11F202/A11F302 PRIF005-US A11H/A11J/E11A/A11F102/A11F152 PRIF006-US A11F202/A11F302 Temperature sensor, Humidity sensor (for PRIF005-US, PRIF006-US) Model Supported UPS PRSN001 Temperature sensor PRSN002 Humidity sensor Flexible Supply Management Computer auto-shutdown function Computers can be automatically shut down in the event of power failure. Not only on power failures, but shutdown can also be performed under conditions of serious trouble or overload. Compatible with mixed Windows-Unix/Linux OS environments, and up to 50 units can be shut down. Multiple shutdown methods: (1) Shutdown via network implementing UPS management. (2) For Unix, Linux and FreeBSD, shutdown by SSH (Secure SHell) or Telnet login. ( installation not needed.) (3) If shutdown control cannot be provided via network, a serial port can be used (only one port). UPS automatic restart when power restored UPSs that were automatically shut down by power failure can be automatically restarted when power is restored. Automatic computer restarting when the UPS restarts depends on computer specifications. Computers that do not restart by restored power may be restarted using the Wake On function or ring signal. Scheduled operation function Daily UPS output on/off operations can be scheduled. (The computer automatically shuts down when the UPS is turned off.) 6

Status monitor Input and output power and battery states can be checked in real time. Record and view UPS status history at regular intervals and when events such as power failures occur. Confirm UPS status and change settings remotely using a Web browser* or SSH/Telnet. * The Web browser is required to support Java applets. Monitor UPS status with an SNMP manager. Support RFC1628 s standard UPS-MIB and private MIB. Notifications of UPS status changes including power failures, battery replacement warnings, serious fault alarms and battery test results can be sent by email. You can also obtain UPS status in response to email requests. When an event occurs, the event log can be sent to a syslog server. System management NTP (Network Time Protocol) support Automatic time synchronization eliminates the need to have someone periodically set the clocks. Setting value download/upload functions Setting values can be downloaded and setting changes uploaded by FTP. Test function Without cutting power you can confirm WS script execution, email sending, SNMP trap sending and shutdown of connected systems. High security compliance Supports SSL/TLS *. Data is encrypted during internet transfers for protection against information leakage by interception or spoofing. *SSL/TLS:Secure Socket Layer / Transport Layer Security. Supports SSL (Secure Socket Layer) encrypted data transfers (HTTPS, FTPS, and encrypted email). Supports the cryptographic security function of SNMPv3. Redundant Supply System Support Support for redundant power systems using up to five UPS units. Ideal for building highly reliable system configurations. Computer-1 UPS-1 (Non-Redundant) Computer-1 (Redundant) UPS-1 + UPS-2 Number of Required UPS=1 Computer-2 UPS-1 + UPS-3 Number of Required UPS=2 Computer-3 (N+1 Redundant) UPS-1 + UPS-2 + UPS-3 Number of Required UPSs=2 Shutdown Request Shutdown Request Interface Card Interface Card Interface Card Communication to confirm supply power UPS-1 UPS-2 UPS-3 Fault Multiple UPSs can be set to shut down according to AND and OR conditions of each connected system. Other UPSs can be set to shut down when a power failure occurs at any one UPS unit. Multiple UPSs can be stopped together at scheduled control times. UPS stop requests (start, stop and reset) can be issued to synchronize multiple UPSs. 7

View Measurement Information View Measurement Information Cumulative output power (kwh) can be stored hourly. Output power value information can be confirmed in a Web browser. (Output power display is available for UPSs that support it.) Past measurement information can be stored as hourly averages, maximum and minimum values for statistical analysis. Statistical information can be confirmed by Web browser. Monitor Measurement Deviations Set thresholds for load factor, ambient temperature and input voltage, to monitor for deviations from the thresholds. Also, the server computer can be shut down due to deviations from a threshold. Monitors UPS ambient environment (Model: PRIF005-US, PRIF006-US) Ambient temperature and humidity can be measured by the corresponding sensors installed in the UPSs. Eliminates the need for additional monitoring devices to save space. Server computers can be shut down when measured temperature or humidity is abnormal. Temperature and humidity statistics can be viewed graphically in daily, monthly and yearly formats. The data can also be saved for easy management. Easily upgrade temperature and humidity sensors by simply connecting a cable. UPS Interface Card Temperature or Humidity sensor cable Max. 16 sensors UPS Option Contact Interface Card This interface card for Sanyo Denki UPSs provides no-voltage contacts for external transfer of UPS signals. Model Model Supported UPS Remarks PRCONIF001-US A11H/A11F102/A11F152/E11A Terminal box type PRCONIF002-US A11F202/A11F302 PRCONIF003-US A11H/A11F102/A11F152/E11A D-sub 15 pin type PRCONIF004-US A11F202/A11F302 8

Examples of Use Pattern 1 Serial/dry contact signal connection 1 For backing up a single personal computer with a UPS with a serial port or a UPS with contact output. Operable without network environment. It can be used for a firewall. Serial / Contact Pattern 2 Serial/dry contact signal connection 2 For backing up multiple personal computers with a UPS with a serial port or a UPS with contact output. A low-cost UPS control system can be realized. Caution: If the personal computer connected with a UPS with serial contact signal connection is not in operation, monitoring and control of other personal computers cannot be performed. Telnet Login Serial / Contact Software Not Required Can be used even on operating systems that do not support. Note: Must be able to log in with Telnet (UNIX, Linux) Pattern 3 connection 1 For backing up a virtual machine with a UPS. can be installed in a host and guest OS. Shutdown is possible by SSH or Telnet login. Host: VMware ESX Server Microsoft Hyper-V Interface Card Virtual machine Guest OS Guest OS Guest OS Host 9

Pattern 4 connection 2 For backing up multiple personal computers/workstations with a UPS in which a Interface Card (optional) is incorporated. Applicable to a clustering system. Remote ON/OFF control is possible. Interface Card SSH (Secure SHell) or Telnet Login Software Not Required Can be used even on operating systems that do not support. Note: Must be able to log in with SSH or Telnet *SSH: SSH is an abbreviation of Secure SHell. Pattern 5 connection 3 For backing up a blade server with a UPS in which a Interface Card optional is incorporated. Up to 50 blade can be shut down. Interface Card Blade Servers Please install the in each blade server. Examples of UPS General Management Use Router Management Software IT Monitor Manager (Option) SNMP Manager* Web Browser* *These need to be set up ahead of time in order to be used. Managing Computer Hub Router UNIX/Linux Computer*/Workstation Cluster System Computer/Workstation Blade Servers Hard Disk Interface Card UPS 10

Notes when investigating use of this product in your applications Before starting installation, assembling and use, read the Operation Manual carefully and use the product correctly in your applications. When you are going to use this product in the following application, the special considerations are required for operation, running, maintenance and control. Be sure to consult with our company as a part of your investigations. (a) Medical equipment and other equipment that are related directly to human life. (b) Train or elevator that can give injury to human body. (c) Socially and publicly important computer systems (d) And other equipment that are related to safety of human life and that can affect severe effects on maintenance of public functions. For the applications that undergo vibration such as vehicles, ships and transportation facilities, please consult with our company. Never modify this product or give additional processing to this product. For the installation and maintenance work, please consult with our company or with specialized company. For any inquiry or consultation, please contact our sales representative. http://www.sanyodenki.com 3-33-1, Minami-Otsuka, Toshima-ku, Tokyo, 170-8451, Japan TEL: +81 3 5927 1020 468 Amapola Avenue Torrance, CA 90501 U.S.A. TEL: +1 310 783 5400 P.A. Paris Nord, 48 Allée des Erables-VILLEPINTE, BP.57286, F-95958 ROISSY CDG Cedex, France TEL: +33 1 48 63 26 61 Frankfurter Strasse 92, 65760 Eschborn, Germany TEL: +49 6196 76113 0 9F 5-2, Sunwha-dong Jung-gu Seoul, 100-130, Korea TEL: +82 2 773 5623 Rm2107-2109, Bldg A, Far East International Plaza, No.319, Xianxia Rd., Shanghai, 200051, China TEL: +86 21 6235 1107 Room 1208, 12F, No.96 Chung Shan N, Rd., Sec.2, Taipei 104, Taiwan, R.O.C. TEL: +886 2 2511 3938 Room 2305, 23/F, South Tower, Concordia Plaza, 1 Science Museum Rd., TST East, Kowloon, Hong Kong TEL: +852 2312 6250 10, Hoe Chiang Road, #14-03A/04, Keppel Towers, Singapore 089315 TEL: +65 6223 1071 The names of companies and/or their products specified in this catalog are the trade names, and/or trademarks and/or registered trademarks of such respective companies. Specifications are subject to change without notice. CATALOG No. P0870B004 13.10