User Manual. BARKODES BİLGİSAYAR SİSTEMLERİ ARF Panel



Similar documents
AC-115 Compact Networked Single Door Controller. Installation and User Manual

User Manual. Before installation and use, please read the user manual carefully.

How To Use An Easypad On A Pc Or Macbook Or Ipad (For Pc)

Access Control System Access Control System is designed for the places where need for crucial security.

PROXIMITY CARD READERS C-10, C-20, C60, C70

ACR880 GPRS Portable Smart Card Terminal

Installation manual. Version

[FAQ] Troubleshooting Access Control Issues

SHENZHEN PROYU BIOMETRIC T/A & A/C TERMINAL QUOTATION

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

ACCESS CONTROL SYSTEM

3 Specification. Master Chip Broadcom Keys Direct-button 1. Microphone 1. Amplifier 0.5W Speaker 0.5W. Voice

EASY PROGRAMMING AND TRANSACTION ANALYSIS SOFTWARE

IRT84. Irt84. Datasheet. EMV L1 compliant terminal with ISO14443A/B. 1

How To Program An Autodialer

25 Years of Manufacturing Excellence. Premier Quatro Addressable Fire Alarm System. Assessed to ISO 9001: 2008

Integrated Building Management and Security System. Building Automation & Security.

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

GV- RK1352 Card Reader

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

P10 - Standalone Access Controller and Reader

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

Changers Kalhuohfummi User Manual

GV-AS/EV Controller. User s Manual

COLOR VIDEO DOOR PHONE CDV-71BE/D

HyperAccess Access Control System

Digital Keypad Use s Manual

PK5500 v1.1 Installation Instructions

Ensto Chago Master EVM300 and EVM500 Operational description

IOVU-571N ARM-based Panel PC

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

A C C E S S C O N T R O L S Y S T E M

minova technology electronics

ZC-24DO CANopen I/O Module: 24 Digital Outputs

User Manual. Listen to your favourite songs on the radio on the road & in a car

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

FMT600BT Transmitter

Introducing... The Word's Most Advance. Biometric Time Attendance Door Access Security System

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

FLOOR INDICATORS CATALOGUE 2007

BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members:

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Ingenico. User Guide 5100M. Secure transaction and payment solutions

GV-AS Controller. Installation Guide

site monitoring Kit Site Monitoring Kit User Manual we prove it.

TruPower-Portable-500W. Solar Starter kit

User Manual. Video Doorphone CDV-1020AQ

Two-way communication, keep checking the commnunication between the panel and accessories, make sure the system safer.

BIOMETRIC SOLUTIONS 2013 ISSUE

BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEMS BURGLAR ALARM SYSTEM EURO ALARM WIRELESS BURGLAR ALARM SYSTEM OASIS

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

ATB50v1 GPRS / GPS Based Fleet Management Terminal. Datasheet

USER MANUAL V5.0 ST100

Integrated Building Management and Security System. Building Automation & Security.

VIDEO DOOR PHONE SYSTEM

Business/ Home GSM Alarm System

L-1 Fingerprint Reader Solutions. V-Flex 4G

Intelligent GSM Auto-Dial Alarm System

Access to the Lift Data Menu is via The Challenger User Menu option - Program Door Data.

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

MultiViu Flex 7 Data Sheet

WALL MOUNTED SPLIT TYPE AIR CONDITIONER

A Fully Integrated Online Hotel Locking System

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

GSM COMMUNICATORS CATALOGUE

FLOOR INDICATORS CATALOGUE 2007

PU-USBX. USB over Ethernet Extender OPERATION MANUAL

Design And Implementation Of Bank Locker Security System Based On Fingerprint Sensing Circuit And RFID Reader

MOBILE CALL GSM Alarm System User s Manual

HAI Access Control. The HAI Access Control Card Reader can be used for:

NOQ_NQ-9121 Z-Wave Data Logger for Gas Meters Firmware Version : 2.55

Meaco 30L and Meaco 40L dehumidifier instruction manual

GSM HOME SECURITY SYSTEM

FLOOR INDICATORS CATALOGUE

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

Aperio Online System Description

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Functional Specification Document

LIFT CONTROL SYSTEMS CATALOGUE 2007

SFC-200 SERIES FIRE ALARM CONTROL PANELS. SFC-200 Series Fire Alarm Control Panels. Features. Description

LEN s.r.l. Via S. Andrea di Rovereto 33 c.s CHIAVARI (GE) Tel Fax mailto: len@len.it url: http//

UniOP epad33 and epad33t

=============================== WARNING

PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

User Guide Nokia Portable Wireless Charging Plate DC-50

Time Attendance V1.4

HP4000EX Hardware Manual

MANUAL Remote Programmer XM3

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

WIRELESS MAGNETIC CONTACT

FLYPORT Wi-Fi G

LIFT CONTROL SYSTEMS CATALOGUE 2007

User Manual Color video door phone

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Transcription:

1 User Manual Barkodes Bilgisayar Sistemleri Bilgi İletişim ve Yazılım Tic. Ltd. Şti. Adres: Altay Çeşme Mahallesi Sanayi Sokak No:8 Demirli Sitesi B Blok Maltepe-İstanbul/Turkey Tel: + 90 (216) 442 20 62 Fax: +90 (216) 459 04 84 Web: www.barkodes.com.tr Mail: info@barkodes.com.tr

2 ARF-PANEL User Manual

3 Contents Preface 4 Safety Measures..5 Applications...6 Technical Data..7 Installation. 8 Connection...9 Operating Modes 10 NOTES: 11 Contact..12

4 Preface ARF-PANEL Card Readers They are such devices with integrated microdatabase for offline operation through TCP/IP Protocol. It is possible to design any Access PDKS applications, and the device records any pass movemements, date, time, direction and card ID details as an event through the RTC (real time clock) and Flash memory. In offline mode, the authorized personnel information is defined on PC/server/main unit. With different inputs, it can host several readers. Reader types: 1- Mifare 13,56 mhz 2- Proximity 125 khz 3- HID 125-13,56 ı class mhz 4- UHF Passive 802-968 mhz 5- UHF Capable of operating with the above readers, the panel perform many door controls.

5 SAFETY MEASURES The following safety measures will extend the usable life of your device. Please follow all the measures and instructions. Consult to a qualified person for all the service needs other than those described herein. Before the cleaning works, be sure to disconnect the power cables. Use a clean cellulose sponge or wash leather cloth and a few drops of lukewarm water to wipe clean the instrument, and dehumidify it by a dry cloth. DO NOT PLACE the unit on any working surface that is not flat or stable. Call the service station if the casing is damaged. DO NOT STOP any object onto the unit, and do not scratch the unit with a foreign substance. DO NOT EXPOSE the unit to dirty or dusty spaces. Do not operate the unit if there is a gas leak. Keep the unit away from the strong magnetic or electrical fields. Do not press or TOUCH the display panel. DO NOT USE the unit in the vicinity of fuels, rainy or humid zones. SAFE TEMPERATURE: -10C to %70 C operating temperature range. INPUT VOLTAVE: 8V-36V DC DO NOT DISPOSE the unit in the public garbage fields. This unit has been designed with the recyclable parts and components. The crossed garbage box symbol means that the product (electrical and electronic equipment, and mercury containing cells and batteries) should not be disposed with the household wastes. DO NOT DISPOSE the batteries together with the urban wastes. The crossed wheel garbage box symbol means that the batteries should not be disposed with the municipal wastes.

6 Applications Personnel Attendance Check System Passover Control System Dining Hall Check System Visitor Check System Special Software Development and Projects Access Control

7 Technical Data CEZERİ SMART ACCESS Voltage: 12 V - 24 V DC Power Consumption, max: 36Watt Short circuit protection: + Display: 128x64 Graphic LCD (optional) Communication: Rs-485 3 pcs Ethernet 10/100 Mbps Rs-232 1 pc (2 pcs optional) Wiegand 2 pcs Communication speed: 9600-115200 bps Operating Mode: Offline Info Anti-Pass Back: + CPU: 80MHz 32 Bit Arm-M3 Processor SD Card: Optional Capacity: 12MByte, 1MByte User Memory: 262.140 Black User Memrory: 16.000 Access Log Memory: 349.500 Event Log Memory: 299.500 Battary Monitor: + Table: Tme GroupZaman Grup, Personel Grup (Max 255 Grup) Spftware Development Kit (SDK): C#, VB,.Net Encoding: + RTC (Real Time Clock): + Keypad: Optional Buzzer: + Led: Red, Green, Yellow USB: Optional Optic isolation: 2 inputs Relay output: 2 pcs Door(IN), 2 pcs Aux(Out) ADC input: 2 pcs Door, 1 pc Aux Temperature sensor: Optional Fire alarm: + Standard compatibility: ISO/IEC 14443A, ISO/IEC 14443B, ISO/IEC 18092-NFC

8 Installation You can easily install your product through the screw holes provided.

BARKODES BİLGİSAYAR SİSTEMLERİ 9 CONNECTION ARF-PANEL User Manual

10 OPERATING MODES Operating Mode LED Color Log Data Offline 2 gren flashing Normal mode in device Data delete In order 1-2-3-4 red Delete log and personnel Factory settings In order 1-2-3-4 red Delete all data Service mode 2 red stable light Locked status Offline Mode When the card is read, if it is authorized, the yellow light in relay flashes with the relay being engaged fort he specified time out period.if no pass is authorized, the TTFSM reader red light flashes. The card ID, date, time, pass direction are recorded in the unit database. Online Authorization If the card is defined in the authorized cards panel, and no response is received with authorization within the timeout period, the online pass is authorized. The after-pass authorization light codes are the same with the offline mode. Online Info It decides in offline mode. The pass information is also transmitted to PC/server/host. (Monitoring mode) Log is stored onboard. Service Mode The unit is set in this mode when an update is in progress in the unit, and in this case, no card is read, nor no pass is allowed.

11