Patient Age Group: ( ) N/A ( X) All Ages ( ) Newborns ( ) Pediatric ( ) Adult

Similar documents
PROCEDURE NO. POC LBH. Printed copies are for reference only. Please refer to the electronic copy for the latest version.

Title: Fingerstick Glucose by Accu-Chek Inform

Inform II. Quick Reference Guide. for Healthcare Professionals BLOOD GLUCOSE MONITORING SYSTEM

Title: Glucose Testing: StatStrip Glucose Meter Page 1 of 6

A Self-Study Packet for The Johns Hopkins Hospital Point-of-Care Testing Program copyright 2011 Johns Hopkins Hospital All rights reserved

In-Service Plan for Blood Glucose Testing.

Hemoglobin Testing using the Data Management HemoCue Analyzer

Inform II Glucose Meter

Preface. Preface. A Healthcare professional should be contacted when Customer Service is not available.

STANDARD OPERATING PROCEDURE FOR NOVA STAT STRIP CONNECTIVITY BLOOD GLUCOSE METERS FOR USE IN LEEDS NHS TRUST

BLOOD GLUCOSE METER. Standard Owner s Booklet for Single Patient Use Only

Textbook: Chapter 12 pages , Chapter 13 pages

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

QUALITY ASSURANCE AND QUALITY CONTROL REFERENCE GUIDE FOR MULTI-PATIENT USE FACILITIES

QUALITY ASSURANCE AND QUALITY CONTROL REFERENCE GUIDE FOR MULTI-PATIENT USE FACILITIES

INTRODUCTION TO CLINICAL PRACTICE AND CLINICAL SKILLS 2nd Year MEDICAL YEAR 2009/2010

Nova Max Blood Glucose Monitor Owner s Guide

Blood Glucose Monitoring System. Owner's Booklet. Instructions for use.

Key Features in the AgaMatrix Jazz

STEP-BY-STEP INSTRUCTIONS FOR INVESTIGATIONAL USE. Rapid HCV Antibody Test FOR ORAQUICK RAPID HCV ANTIBODY TEST

Blood Glucose Monitoring System USER GUIDE. Replaces Owner s Booklet

Caution! Please read complete Owner s Booklet and all product Instructions for Use.

Blood Glucose Monitoring System Owner s Booklet Instructions for use

Self-Monitoring of Blood Glucose

CoaguChek System. XS Plus. User Manual

Chapter 14 Urinalysis, Body Fluids and Other Specimens. Objectives:

Chapter. Guaiac Screening CHAPTER 4: GUAIAC TESTING SCREENING FOR OCCULT BLOOD. Page 1 of 5 Guaiac doc 6/24/2005

Blood Glucose Monitoring System USER GUIDE

CoaguChek System. User Manual. This is a CLIA waived system.

PROCEDURE COVERSHEET. Document Section: CHEMISTRY Author: JOANNE WONG Date Authored: JAN In Use Date: 2/1/2011 Discontinued Date:

SD CodeFree BLOOD GLUCOSE MONITORING SYSTEM

Quality Requirements of a Point of Care Testing Service

Accu-Chek Inform II system. Professional glucose testing for the wireless age

BLOOD GLUCOSE METER. Getting Started Guide for Single Patient Use Only

Suggested BiliChek Usage Protocol

BLOOD CULTURE COLLECTION GUIDELINES FOR PHLEBOTOMISTS (WITHIN REGION 6)

IgM ELISA. For the quantitative determination of IgM in human serum and plasma. For Research Use Only. Not For Use In Diagnostic Procedures.

FDA Public Hearing on Clinical Accuracy Requirements for Point of Care Blood Glucose Meters (BGMs)

I-140 Venipuncture for Blood Specimen Collection

EXERCISE 5: ERYTHROCYTES SEDIMENTATION RATE - ESR, SED RATE

Contents. POCT Program Massachusetts General Hospital - Pathology Service 55 Fruit Street, Boston, MA 02114

Cold Agglutination Titer detecting Cold Reacting Antibodies

General. What is a laboratory test? What is a waived test?

The Golden Rule of Specimen Collection: The Patient Test Result is Only as Good as the Sample We Get

ABORhCard. ABORhCard Package Insert ABO and Rh Blood Grouping Device

Tympanic Thermometer

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

The FreeStyle Lite Meter and How It Works

Aseptic Technique. A GMP/GTP Training Module

FLASH GLUCOSE MONITORING SYSTEM. User s Manual

VENOUS BLOOD COLLECTION

User Manual Important: First read the Medication Guide that comes inside your FORTEO carton.

Biochemistry Validation Form

ACCU-CHEK Inform II BLOOD GLUCOSE MONITORING SYSTEM. Operator s Manual

OneStep Fecal Occult Blood RapiDip InstaTest. Cat #

Mouse IgM ELISA. Cat. No. KT-407 K-ASSAY. For the quantitative determination of IgM in mouse biological samples. For Research Use Only. 1 Rev.

Abstract... i. Committee Membership... iii. Foreword... vii. 1 Scope Introduction Standard Precautions Definitions...

Blood Glucose Monitoring. Eileen Whitehead 2010 East Lancashire HC NHS Trust

Onboard Quality Controls for the CoaguChek XS System

BLOOD GLUCOSE MONITORING SYSTEM USER GUIDE

INFM22AGB. IMM Rev CUSTOMER CARE LINE:

ClikSTAR - Important facts about your new insulin delivery device.

Quality Control of the Future: Risk Management and Individual Quality Control Plans (IQCPs)

URINE DIPSTICK Multistix 10SG

GLUCOSE TOLERANCE (FOR DIABETESMELLITUS)- NON-PREGNANT ADULT/CHILDREN (Under 18 years old) (OGTT)

Radiation Sciences Nuclear Medicine Technology Program Hot Lab Log Book (Material)

Central Line Blood Draw

Reference Range: mmol/l (arterial) mmol/l (venous) CPT Code: 83605

LG Wireless Remote Controller

Administration of Meropenem For Child

Human Free Testosterone(F-TESTO) ELISA Kit

User Manual. Read this user manual carefully before you start testing

Instructions for Use PROCRIT (PRO KRIT) (epoetin alfa)

Urinalysis Compliance Tools. POCC Webinar January 19, 2011 Dr. Susan Selgren

CAP Point of Care Checklist Frequently Asked Questions Roger D. Klein, MD Sheldon Campbell, MD, PhD Peter J. Howanitz, MD

User Guide. Quality Check Messages and Codes (continued) (01) Message Cause Action

Rat Creatine Kinase MB isoenzyme,ck-mb ELISA Kit

User manual TAB-10C

PROCEDURE FOR BLOOD GLUCOSE MONITORING

PD-UserHbk-01. Pages printed from this document are uncontrolled - For latest versions please refer to electronic laboratory handbook

V: Infusion Therapy. Alberta Licensed Practical Nurses Competency Profile 217

e I N S T RUC TION M ANU A L

Advanced Phlebotomy: An on-line Course for Working Phlebotomists. MORE QUESTIONS? Send questions to

510(k) SUBSTANTIAL EQUIVALENCE DETERMINATION DECISION SUMMARY

RT-1261A Ear and Forehead Thermometer Owner s Manual

Blood Glucose & Ketone Monitoring System. User s Manual

THE ACTIVITY OF LACTASE

Obtaining a venous blood sample

MANITOBA PATIENT SERVICE CENTRE STANDARDS

BLOOD GLUCOSE MONITORING SYSTEM USER GUIDE

Instant Ear Thermometer

BLOOD GLUCOSE METER. Active. Owner s Booklet

Title: Microbiology Urine Screening Effective date: 05/08/2013. Summary of Significant Changes at this Revision

Biosafety Level 2 (BSL-2) Safety Guidelines

ACCU-CHEK Inform II BLOOD GLUCOSE MONITORING SYSTEM. Operator s Manual

INSTRUCTIONS FOR USE HUMIRA 40 MG/0.8 ML SINGLE-USE PEN

PACKAGE LEAFLET: INFORMATION FOR THE USER. PARACETAMOL MACOPHARMA 10 mg/ml, solution for infusion. Paracetamol

Teriflunomide is the active metabolite of Leflunomide, a drug employed since 1994 for the treatment of rheumatoid arthritis (Baselt, 2011).

Guidance Document Infectious Substances

PATIENT GUIDE. Understand and care for your peripherally inserted central venous catheter (PICC). MEDICAL

Transcription:

DESCRIPTION/OVERVIEW 1. Purpose 1.1. The Roche ACCU-CHEK Inform II meter quantitatively measures glucose levels in venous, arterial, or fresh capillary whole blood. 2. Principle 2.1. The enzyme on the test strip, mutant variant of quinoprotein glucose dehydrogenase (Mut. Q-GDH), converts the glucose in the blood sample to gluconolactone. This reaction creates a harmless DC electrical current that the meter interprets for the blood glucose result. The sample and environmental conditions are also evaluated using a small AC signal. 2.2. Studies show that the ACCU CHEK Inform II whole blood glucose result compares well with a plasma laboratory method. REFERENCES 1. ACCU-CHEK Inform II Test Strips package insert, 2012. 2. ACCU-CHEK Inform II Controls package insert, 2012. 3. ACCU-CHEK Inform II Linearity Test Kit package insert, 2012. 4. ACCU-CHEK Inform II Operator s Manual, 2012 Applies To: UNM Hospitals and Clinics Responsible Department: Rapid Response Laboratory Revised: 12/2014 Procedure Patient Age Group: ( ) N/A ( X) All Ages ( ) Newborns ( ) Pediatric ( ) Adult AREAS OF RESPONSIBILITY 1. POCT Accu-Chek Inform II glucose testing can be done on any inpatient or outpatient on receipt of an order from a licensed independent practitioner or nursing staff designate. 2. Staff who have satisfied the required competency requirements may perform the testing, refer to the Point-of-Care Testing (POCT) Quality Assurance procedure. PROCEDURE 1. Equipment 1.1. ACCU-CHEK Inform II meter 1.2. Single Use Lancing device 1.3. Base Unit 2. Reagents 2.1. ACCU-CHEK Inform II Test Strips 2.2. ACCU-CHEK Inform II Control Solutions 2.3. ACCU-CHEK Inform II Linearity Test Kit (Laboratory Use Only) 3. Ordering Information 3.1. ACCU-CHEK Inform II Test Strips and ACCU-CHEK Inform II Control Solutions are ordered through CDU. 3.2. ACCU-CHEK Inform II Linearity Test Kits are ordered by the Laboratory. 4. Storage 4.1. The Accu-check Inform II should be stored away from direct sunlight and extreme temperatures. Page 1 of 6

4.2. ACCU-CHEK Inform II linearity and control solutions must be stored at temperatures between 39 86 F (4 30 ºC). Do not freeze. Both solutions are stable for three months after opening or until the manufacturer s expiration date, whichever comes first. Label both vials of control solution with the open and expiration date. 4.3. ACCU-CHEK Inform II Test Strips are stored at temperatures between 36 86 F (2 30 C). Use the test strips at temperatures between 61 95 F (16 35 C) and relative humidity between 10 80 %. Do not freeze. Do not use strips after the manufacturer s expiration date. When a vial of strips has been left opened, discard. Inaccurate results may be obtained using strips exposed to ambient air. 5. Calibration 5.1. Each new lot of Strips must have the Code Key information programmed into the meter before the strips can be used for testing. The POC office will do this prior to the strips being distributed to the departments. 6. Cleaning and Disinfecting 6.1. If a meter is used for a single patient, then cleaning and disinfecting the exterior surface of the meter is, at a minimum, recommended daily. If meters must be used on more than one patient, then the meters must be properly cleaned and DISINFECTED AFTER EVERY PATIENT. 6.1.1. Place meter on a level surface prior to cleaning and disinfecting. Turn meter off. 6.1.2. Use 10% bleach, i.e. Clorox Germicidal or Super Sani-Cloths. Using solutions other than 10% bleach could result in damage to the system components. 6.1.3. When using a pre-moistened cleaning/disinfecting wipe, SQUEEZE OFF EXCESS DISINFECTING SOLUTION or blot on a dry paper towel to remove any excess cleaning/disinfecting solution. 6.2. To Clean the meter. 6.2.1. Gently wipe the exposed surfaces of the meter with a 10% bleach wipe. 6.2.2. Do not allow liquid to enter the strip port or allow pooling on the touch screen. 6.2.3. Wipe dry when done. 6.3. To Disinfect after cleaning the meter. 6.3.1. Use a new 10% bleach wipe to disinfect by gently wiping the outside of the meter according to the disinfectant manufacturer s guidelines. 6.3.2. Make sure that no liquid enters the test strip port. 6.3.3. Allow the surface of the meter to remain damp for the time recommended by the disinfectant solution manufacturer. 6.3.4. Ensure that the meter is THOROUGHLY DRIED after disinfecting. 7. Quality Control 7.1 Two levels of Quality Control solutions needs to be run on the meter at the following times: 7.1.1 Each day of patient testing 7.1.2 If the Accu-check Inform II meter has been dropped. 7.1.3 When a NEW VIAL of test strips is opened. Document on the bottle of glucose strips that QC was performed, date and initials. 7.1.4 When test results contradict clinical symptoms or anytime questionable results are obtained. 7.2. To Perform QC 7.2.1. Select the Control Test icon 7.2.2. Select the Barcode icon and scan the barcode on one control vial. 7.2.3. Select the Barcode icon and scan the barcode on the vial of test strips. 7.2.4. Insert the test strip. The meter will beep when the strip is correctly inserted. 7.2.5. Dose the test strip when the flashing drop picture appears. Page 2 of 6

7.2.6. Apply control to the front edge (yellow dosing area) of the test strip. 7.2.7. The sample is drawn into the test strip automatically. 7.2.7.1. Once a sufficient sample has been detected, measurement begins. If sufficient sample is not detected the meter will display a Sample Detection error. For a complete list of error codes refer to the Accu-chek Inform II Operator s Manual. 7.2.8. An hourglass will appear on the display while waiting for the result. 7.2.9. If QC is out of range, troubleshoot then, select the Conversation Bubble icon and select the appropriate comment: 7.2.9.1. Wrong Control 7.2.9.2. Procedural Error-Select when an error can be identified. 7.2.9.3. Will Repeat-Select when an error cannot be identified, i.e. expired QC. 7.2.10. Select the Checkmark icon to return to the result. 7.2.10.1. Rerun the failed control. If it is still out of range discontinue patient testing and contact the POCT office. 7.2.10.2. Common causes of failure include selecting the low control on the meter, but running the high control or vice versa; expired control solutions; and expired test strips. 7.2.11. Select the Checkmark icon to return to the Control Test menu. 7.2.12. Repeat the procedure with the other control. 7.2.13. Quality Control data is reviewed on a monthly basis by the POCT department and QC records stored in the POC office for 2 years for inspection purposes. 8. Patient Management 8.1. Patient Identification 8.1.1. Follow the Hospital Patient Identification procedure. 8.2. Patient Preparation 8.2.1. The operator must describe to the patient the purpose and the steps of the procedure before testing can begin. 9. Specimen Collection and Handling 9.1. Universal Precautions apply to all POC tests. 9.2. Testing personnel should handle all patient samples as per the hospital Bloodborne Pathogen Exposure Control Plan. 9.3. Capillary, venous, and arterial fresh whole blood may be used. 9.3.1. Test the blood sample as close as possible to the time the sample was collected but within 30 minutes of collection to minimize glycolysis. 9.3.1.1.The blood glucose concentration will decrease over time because viable red blood cells continue to consume glucose. 9.4. Fresh whole blood, in the absence of an anticoagulant, should be tested immediately to prevent clotting from affecting the results. 9.4.1. Do not attempt to express blood from a previously punctured site. If repeat testing is performed, each test should be performed from a new skin puncture. Even if an old puncture site appears to be bleeding freely, it is likely that the clotting process has begun and may affect the patient result. 9.5. Serum and plasma may NOT be used. 9.6. Cord blood may NOT be used. 9.7. Whole blood anti-coagulated with fluoride or Iodoacetate preservatives may NOT be used. 9.8. Whole blood anti-coagulated with heparin or EDTA may be used. 9.9. To collect a venous or capillary sample, refer to the Hospital s Phlebotomy Self-Study Module. Page 3 of 6

10. Specimen Labeling 10.1. Specimens for Accu-check Inform II glucose testing can be tested in the presence of the patient immediately after collection and then discarded. 10.2. If testing is to be delayed or performed away from the patient, the specimen should be labeled as per the Hospital s Specimen Labeling procedure. 11. Patient Testing 11.1. Press the power button to turn the meter on. 11.2. Enter your operator identification (ID) by selecting the Barcode icon and scan your operator ID. 11.3. Select Patient Test. 11.4. Enter the patient ID by selecting the Barcode icon and scan the patient s financial number. 11.4.1. The meter will display a Patient Confirmation screen. Ensure that the displayed patient information is correct and select the Check Mark icon. 11.4.1.1. If the information is not correct select the X icon and scan the correct patient ID. 11.5. Select the Barcode icon and scan the barcode on the vial of test strips. 11.6. Remove a test strip from the vial. Immediately replace the cap on the vial. 11.7. Hold the test strip so the lettering ACCU-CHEK is facing upwards. Slide the strip into the strip port as far as it goes in the direction indicated by the arrows on the test strip. The meter will beep when the strip is correctly inserted. Note: Insert test strip BEFORE dosing. 11.8. When the flashing drop picture appears obtain a blood sample. 11.9. If a sample is drawn into a Heparin or EDTA tube or syringe, gently mix the sample before testing. 11.10. Apply the drop of blood to the front edge (yellow dosing area) of the test strip. 11.11. The blood is drawn into the test strip automatically. 11.11.1. Once a sufficient sample has been detected, measurement begins. If sufficient sample is not detected the meter will display a Sample Detection error. For a complete list of error codes refer to the Accu-chek Inform II Operator s Manual. 11.12. An hourglass will appear on the display while waiting for the result. 11.13. When the meter displays the result it will also indicate if the result is in normal range, out of normal range, or if it is a critical value. A comment must be entered if the result is critical. 11.13.1. To enter a comment, select the Conversation Bubble icon and select the appropriate comment, i.e. Nurse Notified, followed by the Check Mark icon. 11.14. Then select the Checkmark icon to return to the Main Menu. 11.15. Remove the test strip from the meter and discard it in a biohazardous waste receptacle. 11.16. Press the power button to turn off the meter. 11.17. The meter must be turned off prior to docking. 12. Result Reporting 12.1. Patient results will be immediately recorded electronically in the patient s permanent medical record unless the Procedural Error comment is selected. 12.2. Results that appear to be inconsistent with patient therapy or condition should be viewed as questionable and the test should be repeated or a specimen should be sent to the laboratory. (Refer to Interfering Substances and Limitations section 14.) 12.3. If the Accu-check Inform II meter displays LO the result is <10 mg/dl and if it displays HI the result is >600 mg/dl. Reference Interval and Critical Values 13. Reference Interval and Critical Values Page 4 of 6

13.1. All POCT done in the hospital has a reference interval (normal reference range) validated with those tests performed on laboratory instruments. The reference interval thus correlates to that of the laboratory. See the table below for reference range values. 13.2. All critical values must be reported to the appropriate provider. 13.3. The treating provider has discretion to choose if critical values should be repeated by the laboratory reference method. REFERENCE INTERVAL: Fasting Blood glucose levels: Age Interval 0 1 Month 55 90 mg/dl 1 Month 15 Years 60 115 mg/dl 16 Years 60 100 mg/dl CRITICAL RANGE: Age Range < 16 Years <41 mg/dl or >149 mg/dl 16 Years <50 mg/dl or >600 mg/dl REPORTABLE RANGE: 10 600 mg/dl 14. Interfering Substances and Limitations 14.1. Caution should be taken to clear arterial lines before blood is drawn. 14.2. Do not use serum or plasma samples. 14.3. If peripheral circulation is impaired, collection of capillary blood is not advised as the results might not be a true reflection of the physiological blood glucose level. Examples would include, but are not limited to: 14.3.1. Severe dehydration caused by diabetic ketoacidosis or the hyperglycemic hyperosmolar non-ketotic syndrome. 14.3.2. Hypotension 14.3.3. Shock 14.3.4. Sepsis 14.3.5. Peripheral arterial occlusive disease. NOTE: In these situations, a venous or arterial whole blood sample may be used. 14.4. The system has been tested with capillary neonatal blood. As a matter of good clinical practice, caution is advised in the interpretation of neonate glucose values below 50 mg/dl. 14.5. Blood concentrations of galactose >15mg/dL will cause overestimation of blood glucose results. 14.5.1. Glucose values in neonates suspect for galactosemia should be confirmed using the laboratory reference method. 14.6. Intravenous administration of ascorbic acid which results in blood concentrations of ascorbic acid >3mg/dL will cause overestimation of blood glucose results. 14.7. Lipemic samples in excess of 1800 mg/dl may produce elevated results. 14.8. Patients with a hematocrit below 10% or above 65% should only be tested using the laboratory reference method. Abnormal hematocrits can cause abnormal glucose results. 14.9. This system has been tested at altitudes up to 10,000 feet. 14.10. The system is not for use in diagnosis or screening of diabetes mellitus. 14.11. Error codes can be found in the Operator s Manual. Page 5 of 6

CLIA Classification Use If definitive, how will results be used? Waived Definitive Used as a basis for treating the hyper/hypoglycemic patient. SUMMARY OF CHANGES #7.1.3 was added. Replaces Accu-Chek Inform II, 02/2013. RESOURCES/TRAINING Resource/Dept Point-of-Care Testing 272-0980 Contact Information DOCUMENT APPROVAL & TRACKING Item Contact Date Approval Owner Point of Care Testing Coordinator/Point of Care Consultant(s) Tricore Reference Laboratories Committee(s) Point of Care Testing Advisory Committee, Clinical Operations PP&G Committee, Nursing PP&G Subcommittee Y Nursing Officer Sheena Ferguson, Chief Nursing Officer N/A Medical Director Matthew Luke, MD; Rapid Response Laboratory Y Official Approver Erin Doles, Administrator Professional & Support Services Y Official Signature Date: 2/9/2015 Effective Date 2/9/2015 Origination Date 8/2007 Issue Date Clinical Operations Policy Coordinator 2/16/2015 ar Page 6 of 6