EMC TEST REPORT For. Webcam. Model Number: CAM67U

Test Report. Prepared for: Technologic Systems, Inc. Model: TS-8820

Rated Power(W) 8W 2. EG-LED W 3. EG-LED W

TEST REPORT EN (1997) +A1 (2001)

EN v1.2.1 TEST REPORT FOR ag/Draft n WLAN PCI-E Mini Card MODEL NUMBER: BCM94322MC REPORT NUMBER: 07U

EMC TEST REPORT For. Shenzhen Homelux Security Equipment Co., Ltd. Auto Dialer. Model No.: HX-GD20

Test Report #: Date: April 8, 2005

Prepared for Dorman Long Engineering Technology Consultant (Shanghai) Co., Ltd.

SHENZHEN GEMBIRD ELECTRONICS LTD EMC REPORT

Electromagnetic Compatibility Test Report Test results of Floww equipment

EMC Test for Compliance with EU EMC Directive 2004/108/EU

Standard: EN :1995, EN :1996, ENV :1993, & EN :1995 Solid State Energy Meter

Declaration of Conformity.

Measurement of RF Emissions from a Final Coat Electronics Corrosion Module

FCC PART 15B CLASS A MEASUREMENT AND TEST REPORT

Declaration of Conformity.

Variant Model No. The equipment under test has found to be compliant with the applied standards. (Refer to the attached test result for more detail.

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.

MYRICOM, INC. TEST REPORT FOR THE LAN INTERFACE CARD, M3F2-PCIXE-2

TEST REPORT Rapporto di prova EMC N Test facility site: via L. da Vinci, 92, Caravaggio (BG), Italy Sede laboratorio

EMC TEST REPORT. Page: 1 of 38. Reference No.: WT S-E

Declaration of Conformity.

Waveguide Access Point WGA631. Product Guide

Declaration of Conformity.

Declaration of Conformity.

Declaration of Conformity.

RAPPORTO DI PROVA / TEST REPORT

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Electromagnetic Compatibility Test Report. DC DC umodule Regulator LTM4613

CE EMC Test Report. : Texas Instruments Incorporated : WiFi and Bluetooth Evaluation Board

R&S R-Line Compact Test Chamber Precise measurements of radiated emissions of wireless terminals 800 MHz to 18 GHz

Dual Chamber Temporary External Pacemaker

LAB 1 TECHNICAL DOC 3 IN ONE LAB DEVICE. Velleman Legen Heirweg Gavere Belgium

Telephone- and leased line modem for industrial applications TD-36

AN003. Evaluation of Anechoic Chambers For EMC Measurements Using A CNE. Overview. CNE III 9kHz to 2GHz Conducted and radiated output

MYRICOM, INC. TEST REPORT FOR THE SERVER RACK, 10G-PCIE2-8B2-2S & 10G-PCIE2-8B2-2QP FCC PART 15 SUBPART B SECTIONS AND CLASS A TESTING

TEST REPORT. Please refer to section 3 of this report which indicates which item was actually tested and which were electrically identical.

EMC STANDARDS STANDARDS AND STANDARD MAKING BODIES. International. International Electrotechnical Commission (IEC)

Verizon NEBS TM Compliance: Data Center Equipment NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9703 Issue 2, March 2012

RADIO TEST REPORT. EN SRD radio equipment to be used in the 1 GHz to 40 GHz frequency range. DAkkS - Registration number : D-PL

Rules for Classification and Construction Additional Rules and Guidelines

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Evaluating Cell Phone and Personal Communications Equipment and their EMC Effects on Automotive Audio and In-Cabin Modules

Rack mounted telephone- and leased line modem for industrial applications

Verizon NEBS TM Compliance: HVAC Systems NEBS Requirements Verizon Technical Purchasing Requirements VZ.TPR.9808 Issue 1, April 2014

Draft ETSI EN V1.2.1 ( )

GSM Voice Auto Dialer & SMS Sender JC-999

Uncertainties of immunity measurements

Indoor / Outdoor Antenna

BioStation Mifare OC(BSM-OC) NONE. Receipt Date 21-Feb-08 Receipt Number. Issued Date 18-Mar-08 Tested Date

R&S ENY81-CA6 Coupling Network For radio disturbance and immunity measurements

Clamp Filters that Suppress Emission Noise Provide Immunity Against Surge Noise

AN3353 Application note

ELECTROMAGNETIC COMPATIBILITY TEST. Report reference N R-255 EMC 2010

Test result: SHENZHEN TIMEWAY TECHNOLOGY CONSULTING CO LTD. ISO/IEC17025Accredited Lab. Report No: FCC File reference No:

FCC PART 15 SUBPART C EMI MEASUREMENT AND TEST REPORT

Vert-X 16-5V / % Ub. Applications Servodrives Dancer arm Operating table

IEC and CISPR Standards

Correlation between OATS, Fully Anechoic Room and GTEM Radiated Emissions

CERTIFICATE. Issued Date:May. 18, 2006 Report No.: 065L043-IT-CE-P07V03. MGate MB318n(-T) (n=0~9,a~z)

40 Years of experience in EMC testing

30 In Compliance October

DATA SHEET DVI - HDCP Extension Cable

Applications in EMC testing. Outline. Antennas for EMC Testing. Terminology

Pre-Compliance Test Method for Radiated Emissions of Automotive Components Using Scattering Parameter Transfer Functions

TEST REPORT FROM RFI GLOBAL SERVICES LTD

Foxboro Evo Process Automation System

The impact of the New EMC Directive 2004/108/EC

NMI R 118 Testing Procedures and Test Report Format for Pattern Evaluation of Fuel Dispensers for Motor Vehicles (OIML R 118:1995(E), NEQ)

Uncertainty evaluations in EMC measurements

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

RF data receiver super-reactive ASK modulation, low cost and low consumption ideal for Microchip HCS KEELOQ decoder/encoder family. 0.

TEST REPORT. CONCLUSION: The submitted sample was found to COMPLY with the test requirement

Predicting radiated emissions from cables in the RE02/RE102/DO- 160/SAE J test set up, using measured current in NEC and simple TX equations.

Automatic Distance/Time Speedmeter Handbook (Second Edition) Provisional

Operating Manual UWAPS-TINY Series

Partial GSM TEST - REPORT

Frequency selective monitoring and logging of environmental electromagnetic fields

Design and Certification of ASH Radio Systems for Japan

Rosemount 333 HART Tri-Loop

15 Series - Electronic step relay and dimmer. Features SERIE

AXIS T81B22 DC 30W Midspan

C13 User Manual Document ID: 2CMC486004M0201 Revision: A

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Declaration of Conformity.

Broadband over Power Line (BPL) Test Procedures and Equipment Authorization

Nardalert S3 Non-Ionizing Radiation Monitor

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

Rosemount 333 HART Tri-Loop

Espotel Test Laboratory Services. November 20, 2014

ETSI EN V1.1.1 ( )

Energy Management Energy Meter Type EM23 DIN

WIRELESS MAGNETIC CONTACT

THE NARTE EMC ENGINEER CERTIFICATION PROCESS - A PERSONAL EXPERIENCE

Panashield, Inc. Facility Solutions For Global Electromagnetic Compatibility

Continuous, remote monitoring and logging of electromagnetic fields

ORION TELECOM NETWORKS INC. T1

W O R L D C L A S S H I F I

CONDUCTED EMISSION MEASUREMENT OF A CELL PHONE PROCESSOR MODULE

Cond-IS RF Conducted Immunity System

Transcription:

BUREAU VERITAS TEST REPORT No.: (5213)211-1355 TEST REPORT To: INNOKIN TECHNOLOGY CO., LTO I Fax: I -- Attn: -- I Email: I -- Address: Buildinq 6, XinXin Tian Industrial Park, XinSha Road, Sha.Jinq street, ShenZhen, China Cc: -- I FaxlEmail: I -- Attn: -- Folder No.: GTL-13JY212ETZP-B I Test Date(s): I 2013-07-31 to 2013-08-01 MANUFACTURER OR SUPPLIER NAME: MANUFACTURER OR SUPPLIER ADDRESS: PRODUCT: itaste-134 MODEL REFERENCE: ADDITIONAL MODEL & MODEL DIFFERENCE: itaste-134 RATED VOLTAGE: 3.8Vd.c. ("rechargeable battery" x 1) REMARKS: SAMPLE NO.: SZ130729/012 The submitted sample of the above equipment has been tested according to following European Directive - Electromagnetic directive 2004/108/EC and the tests have been carried out according to the requirements of the following standards: EN 61000-6-3: 2007 +A1: 2011 EN 61000-6-1: 2007 CONCLUSION: The submitted sample was found to COMPLY with the test requirement Manager, Electrical Department ff ~ -I'Nam~ng 1 Date: August 8, 2013 BUREAU VERITAS HONG KONG LlMITED- This report IS Intended for your exclusive use Any copymg or replication of this report to or for any other person or entity. or use of our name or trademark. IS pernutted onl~ \\ nh our prior written permission Our report IS limited to the test samples Identified herem. The results set forth In tlus report are not necessarily mdrcanve or representative of the statistical quality or charactensucs of the lot from which a test sample was taken or any similar or Identical product unless specifically and expressly noted Our report mcludes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request additional testing of the samples or to notify us of any errors or omissions relating to our report. provided. however. such notice shall be In wntmg and shall specifically address the ISSueyou wrsh to rarse A failure to rarse such Issue wnhm the prescribed time shall constitute your unqualified acceptance of the completeness of this report. the tests conducted and the correctness of the report contents Page 1 of 12

Equipment Under Test: Product : itaste-134 Model No. : itaste-134 Power Supply : 3.8Vd.c. ( rechargeable battery x 1) Data Cable : -- Power Line Cable : -- Accessory Device : -- Description of Adaptor: Adaptor : -- Model : -- Input : -- Input power line cable : -- Output : -- Output power line cable : -- Additional Product Name: -- Additional Model No.: -- Additional Model Information: -- Description of Test modes: On mode: with light Standby mode Report Revision & Sample Re-submit History: -- Remark: - For the test results, the EUT had been tested with all conditions. The worst case was showed in test report. The measurement instrumentation uncertainty would be taking into consideration on each of the test result Page 2 of 12

Test Standards The tests have been carried out according to the requirements of the following standards: EN 61000-6-3: 2007 +A1: 2011 EN 61000-6-1: 2007 Test Standards Electromagnetic compatibility (EMC) -- Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments Electromagnetic compatibility (EMC) -- Part 6-1: Generic standards - Immunity for residential, commercial and lightindustrial environments Page 3 of 12

Test Result Summary EMISSION TEST Test requirement: EN 61000-6-3: 2007 +A1: 2011 Test Condition Radiated Emission Test, 30MHz to 1GHz Test requirement: EN 61000-6-1: 2007 Test Condition Electrostatic Discharge (ESD) Test, Contact, ±4kV Air, ±8kV Radiated Immunity Test, 80MHz to 1GHZ, 3V/m 1.4GHz to 2GHz, 3V/m 2GHz to 2.7GHz, 1V/m Test Method CISPR 16-2-3 IMMUNITY TEST Test Method IEC 61000-4-2 IEC 61000-4-3 Test Result Pass Failed Test Result Pass Failed Page 4 of 12

Test Laboratory & Test Instruments List BUREAU VERITAS HONG KONG LIMITED, EMC CENTRE No. 2106-2107, 21/F., Westin Centre, 26 Hung To Road, Kwun Tong, Kowloon, Hong Kong Test Instrument List Radiated Emission EQUIPMENT MANUFACTURER MODEL NO. SERIAL NO. EMI TEST RECEIVER R&S ESCI 100379 BILOG ANTENNA SCHAFFNER CBL6112D 25229 OPEN AREA TEST SITE BVCPS N/A N/A ANECHOIC CHAMBER ALBATROSS M-CDC 80374004499B Electro-Static Discharge EQUIPMENT MANUFACTURER MODEL NO. SERIAL NO. ESD SIMULATOR KIKUSUI KES 4021 ME004852 Radiated Immunity EQUIPMENT MANUFACTURER MODEL NO. SERIAL NO. SIGNAL GENERATOR R&S SMB100A 100981 RF AMPLIFIER SCHAFFNER CBA 9433 T43544 ANTENNA X-WING BILOG TYPE SCHAFFNER CBL 6143 5123 POWER METER R&S NRVD 102067 POWER AMPLIFIER MIILMEGA AS0104-55_55 1029808 Remarks: - N/A: Not Applicable or Not Available Page 5 of 12

Test Results Emission Radiated Emissions (30MHz to 1GHz) Test Requirement: EN 61000-6-3 Test Method: CISPR 16-2-3 Test Limits: Table 1 Test Date(s): 2013-07-31 Temperature: 30.0 o C Humidity: 79.0 % Atmospheric Pressure: 100.2 kpa Mode of Operation: On mode Tested Voltage: 3.8Vd.c. ( rechargeable battery x 1) Test Method: The equipment under test (EUT) was placed on a non-conductive turntable with dimensions of 1.5m x 1m and 0.8m high above the ground. 3m from the EUT, a broadband antenna mounting on the mast received the signal strength. The turntable was rotated to maximize the emission level. The antenna was then moving along the mast from 1m up to 4m until no more higher value was found. Both horizontal and vertical polarization of the antenna were placed and investigated. Radiated emissions measurements are investigated and taken pursuant to the procedures of CISPR 22. Location: The Roof, Westin Centre, 26 Hung To Road, Kwun Tong, Kowloon, Hong Kong Test Setup: Open Area Test Site Antenna Mast Measuring Antenna Turntable 3meter Receiver Page 6 of 12

Limits for Radiated Emission: Frequency Range Quasi-Peak Limits [MHz] [dbµv/m @ 3m] 30-230 40.0 230-1000 47.0 Measurement Data Test Result of (On mode): PASS Detection mode: Quasi-Peak Frequency (MHz) Polarity (H/V) Field Strength at 3m (dbµv/m) Limit at 3m (dbµv/m) Margin (db) Emissions detected are more than 20 db below the limit line(s) Note: Field Strength includes Antenna Factor and Cable Loss. Page 7 of 12

Immunity Susceptibility Performance Criteria A B C D Normal performance within the specification limits Temporary degradation or loss of function or performance which is selfrecoverable Temporary degradation or loss of function or performance which requires operator intervention or system reset Degradation or loss of function which is not recoverable due to damage of equipment (components) or software, or loss of data Page 8 of 12

Electrostatic Discharge Test Requirement: EN 61000-6-1 Test Method: IEC 61000-4-2 Test Level: ±4kV for Direct & Indirect Contact Discharge ±8kV for Air Discharge Performance Criterion Requirement: Test Date(s): 2013-08-01 Temperature: 24.0 o C Humidity: 52.0 % Atmospheric Pressure: 99.8 kpa Mode of Operation: On and standby mode Tested Voltage: 3.8Vd.c. ( rechargeable battery x 1) Test Method: The test was performed in accordance with IEC 61000-4-2. B Location: No. 2106-2107, 21/F., Westin Centre, 26 Hung To Road, Kwun Tong, Kowloon, Hong Kong Test Setup: Page 9 of 12

Test Levels for Electrostatic Discharge: Level Test Voltage Test Voltage Direct & Indirect Contact Discharge Air Discharge Measurement Data 1 ±2kV ±2kV 2 ±4kV ±4kV 3 ±6kV ±8kV 4 ±8kV ±15kV Test Result of (On and standby mode): PASS Please refer to the following table for individual results. Location Discharge Method HCP [Horizontal Coupling Plane] Indirect Contact ±4kV VCP [ Coupling Plane] Indirect Contact ±4kV Enclosure Air ±8kV Metallic Parts Direct Contact ±4kV Test Individual Results Voltage Pass Failed Observation: EUT normal operation and fulfilled Performance criterion A of requirement. Page 10 of 12

Radiated Immunity (80MHz to 2.7GHz) Test Requirement: EN 61000-6-1 Test Method: IEC 61000-4-3 Test Level: 3V/m and 1V/m Modulation: 80% 1kHz AM Performance Criterion Requirement: Test Date(s): 2013-07-31 Temperature: 24.0 o C Humidity: 53.0 % Atmospheric Pressure: 100.2 kpa Mode of Operation: On and standby mode Tested Voltage: 3.8Vd.c. ( rechargeable battery x 1) Test Method: The test was performed in accordance with IEC 61000-4-3. A Location: No. 2106-2107, 21/F., Westin Centre, 26 Hung To Road, Kwun Tong, Kowloon, Hong Kong Test Setup: Anechoic Chamber Full Anechoic Chamber Absorbers 3m Computer Turntable EUT Power Amplifier Signal Generator Page 11 of 12

Measurement Data Test Result of (On and standby mode): PASS Please refer to the following table for individual results. Frequency (MHz) 80-1000 1400-2000 80-1000 1400-2000 80-1000 1400-2000 80-1000 1400-2000 Face Polarity Level (V/m) 0 o Horizontal / 90 o Horizontal / 180 o Horizontal / 270 o Horizontal / Dwell Time (s) 3 1 3 1 3 1 3 1 Individual Results Pass Failed Frequency (MHz) Face Polarity Level (V/m) 2000-2700 0 o Horizontal / 2000-2700 90 o Horizontal / 2000-2700 180 o Horizontal / 2000-2700 270 o Horizontal / Dwell Time (s) 1 1 1 1 1 1 1 1 Individual Results Pass Failed Observation: EUT normal operation and fulfilled Performance criterion A of requirement. ***** End of Test Report ***** Page 12 of 12