150 kv AC substation

Similar documents
SF 6 Gas Insulated Switchgear Type SDF for 170 kv

High Voltage Circuit Breakers 3AP Type 72.5 kv to 800 kv Answers for energy.

Dead Tank Circuit Breaker 72PM40-C Proven reliability through common platforms

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

High-Voltage Compact Switchgear 3AP1 DTC for 145 kv and 245 kv

Series 8146/5-V37 and Series 8150/5-V37

Siemens Integrated Substation Condition Monitoring System. Circuit Breaker Monitoring

Electronic overload relay EF65, EF96 and EF146

The complete range of consumer switchboards and switchgear

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

High-Voltage Circuit-Breakers 3AP1/ kv up to 550 kv. Power Transmission and Distribution

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Electronic overload relay EF19 and EF45

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Fundamentals of Modern Electrical Substations Part 1: Mission of Electrical Substations and their Main Components

Circuit Breakers. NRC Series. NRC Series

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Erik Backström, High Voltage breakers, After Sales & Service High voltage SF 6 live tank circuit breakers After Sales & Service Training course

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Unified requirements for systems with voltages above 1 kv up to 15 kv

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines

Type: DILM9 10(24VDC) Article No.:

Three-phase monitoring relay CM-PFE

Circuit Breaker LTB D with Motor Drive. Motor Drive. ABB PP/H/HV - Page 1. Ed

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Transformer oil cooler ALFA A02

Type: DILM32 10(24V50HZ) Article No.:

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Reyrolle Protection Devices. 7PG17 - XR Intertripping, Interposing, Supervision and Special Purpose Relays. Answers for energy

Type: DILM50(230V50HZ,240V60HZ) Article No.:

ECOCIAT. Domestic hot water heat recovery unit

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Trip circuit supervision relay. Type RXTCS

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

3/2- and 2/2-way cartridge valve type BVE

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

Auxiliary Relay. Type P8n, PQ8n, PN8n

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Table of Contents. TransformerIQ FAQs 1

8146/5 Series Breaker Panelboards

Outdoor circuit breaker GVR Recloser Hawker Siddeley Switchgear. rated voltage 15, 27 and 38 kv rated current 630 A

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

R.C.C.B. s two-pole LEXIC

The Intelligent AX1 Switchgear for Medium Voltage

Data Sheet. Electro-mechanical counters Hengstler 800 series

Voltage Regulator SPAU 341 C. Product Guide

MEDIUM AND HIGH VOLTAGE CAPACITORS, CAPACITOR BANKS AND SYSTEMS

3/2-way Solenoid Valve, direct-acting, NC or NO

WE-350 Series ¼ Turn Electric Actuator

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

FP2 Relay. The Best Relaytion

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

LEVEL GAUGES WITH MAGNETIC JOINT L 14 - L 22 - L 34

METAL-CLAD AND METAL-ENCLOSED SWITCHGEAR 3.6KV~40.5KV. tgood.com. Energy. Fast.

3AH5 Vacuum Circuit-Breakers. Answers for energy. Medium-Voltage Equipment Selection and Ordering Data. Catalog HG

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Tmax MCCBs. Molded case circuit breakers. Tmax

The standards mentioned in this document

Solenoid valves Type EVU

Vario-Series Accessories

Assisted lift operated 2/2-way solenoid valves Type EV250B

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

CAPACITOR BANK TESTING SWP

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

Unit 24: Applications of Pneumatics and Hydraulics

OLI. Oil level indicator

Series description: Wilo-Yonos MAXO-D

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

MV, HV AND EHV SWITCHGEAR TESTING & COMMISSIONING

Plug and Socket Devices CES 63 A Series 8579

RM4TG20 three-phase network control relay RM4-T - range V

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

Linear Luminaire with LED Series EXLUX 6402/2

Circuit Breakers. Next Generation of Protection Capabilities

TWENTIES WORKSHOP, EWEA 2012 Unveiling the future energy system: full scale demonstrations to reach 2020 targets. 17th April 2012

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

T Substation Maintenance and Commissioning Test Equipment

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Hyperlinks are Inactive

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

48 SERIES Relay interface modules 10 A

Residual current socket 30mA Order No.:

Medium voltage arc flash eliminator units VAM 3ED,

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

LC/LCD ranges level controllers

Reed V23100-V4 Relay. AXICOM Telecom-, Signal and RF Relays. AXICOM Telecom-, Signal and RF Relays. Reed V23100-V4 Relay

Series description: Wilo-Yonos MAXO

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Transcription:

150 kv AC substation Outdoor AIS AC substations High-voltage components Circuit breakers ETS-50-06-05-E1 Rev. 1 technical standard Document no. 13/90592-105 - ETS-50-06-05-E1 v.1

REVISION VIEW Document no.: 13/90592-105 Version Author Document status/change Reviewer Approver Date JLY, JAS, BEJ, 0 TEB THO, EHN, EOM, CUM, BMP, HRH JSO 2013.06.17 1 JLY Minor editorial changes 2013.12.16 Document no. 13/90592-105 - ETS-50-06-05-E1 v.1 2/9

Table of contents 1. Introduction 4 2. Standards and regulations 4 3. Functional requirements 4 3.1 Operating mechanism 4 3.1.1 Motor drive 4 3.2 SF 6 gas 4 3.3 Insulators 5 3.4 Circuit breaker operational modes 5 3.5 Closing and trip coils 5 4. Technical requirements 5 4.1 Ratings 5 4.2 Circuit breaker class 5 4.3 Rated operating sequence and K pp factor 5 4.4 Break time 6 4.5 Point of wave switching (POW) 6 4.6 Alarms 6 4.7 Auxiliary contacts 6 4.8 Connection of measuring equipment 6 4.9 Physical dimensions 6 4.10 High-voltage terminals 6 4.11 Switching of shunt reactors, filters, cables and shunt capacitors 7 4.12 Control voltage 7 4.13 Control cabinets 7 5. Design requirements 7 5.1 Mechanical endurance class 7 5.2 Corrosion protection 7 5.3 Earthing 7 5.4 Position indicators 8 5.5 Circuit breaker support 8 6. Documentation 8 7. Appendices 9 7.1 Appendix 1 9 7.1.1 Drilling plan high voltage terminals 9 7.1.2 Foundation and foot print for circuit breaker stand 9 Document no. 13/90592-105 - ETS-50-06-05-E1 v.1 3/9

1. Introduction This standard specifies the minimum requirements for outdoor AIS circuit breakers for the 150 kv voltage level. 2. Standards and regulations The circuit breakers shall be in compliance with the following standards and regulations. Outdoor AIS AC substations common conditions and technical requirements for high voltage apparatus, ETS-50-00 IEC/EN 62271-1 High-voltage switchgear and control gear (Common specifications) IEC/EN 62271-100:2001 High-voltage switchgear and control gear Part 100: High-voltage alternating current circuit breaker IEC/EN 62271-100:2001 / A1:2002 High-voltage circuit breaker gear and control gear Part 100: High-voltage alternating current circuit breaker amendment 1 IEC/EN 61000 Electromagnetic compatibility (EMC) Other standards referred to in the above standards. 3. Functional requirements The circuit breaker shall be: SF 6 puffer type. Have an operation counter. Closing of a circuit breaker shall only be possible if the circuit breaker can be opened immediately thereafter (CO-operation). 3.1 Operating mechanism The circuit breakers shall have a spring-operated mechanism or a servo drive. Hydraulic or pneumatic operating mechanisms are not accepted. The individual circuit breaker poles shall be mechanically independent. In case of spring-operated mechanism, it shall be possible to charge the spring-operated mechanism manually in the event of power failure 3.1.1 Motor drive A safety switch shall be installed in the motor circuits in accordance with DS/EN 60204-1. 3.2 SF 6 gas SF 6 gas leaks shall be 0.5% per year. There shall be indicators showing the amount (density/ pressure) of the SF 6 gas in the breaking chambers and other parts of the circuit breaker. The indicators shall display absolute values of the amount (density/ pressure) of SF6 gas in the SI units bar or MPa. The indicators shall be made of UV resistant material. The SF 6 gas monitoring system shall include an alarm and a blocking function. The blocking function shall apply to all trip circuits. Refilling of SF 6 gas shall be easy and accessible from the ground, meaning that no ladder or lift is needed in order to refill SF 6 gas or to read the SF 6 gas amount. Document no. 13/90592-105 - ETS-50-06-05-E1 v.1 4/9

3.3 Insulators The circuit breaker shall have composite insulators with soft sheds i.e. made of silicone rubber. 3.4 Circuit breaker operational modes Each individual breaker pole shall have a local change-over switch for selection of the command location. The switch shall have three possible settings: Local Remote 0 (0 = blocked). The change-over switch shall have free contact sets for remote display of the selected change-over switch position. Each individual breaker pole shall have a clearly marked operating device for local manual opening and closing. 3.5 Closing and trip coils There shall be one closing coil and two trip coils. The two trip coils shall be mechanically, electrically and magnetically independent of each other. The two trip circuits shall be galvanically and physically separated. No components shall be included in both circuits. It shall be possible to connect the cables for the two trip circuits on separate terminal blocks. An error in the circuit breaker s control circuit, for example a permanent open/close command, shall not result in pumping of the circuit breaker. 4. Technical requirements In addition to breaking short-circuit currents, the circuit breakers shall also be suitable for switching of shunt reactors, filters and shunt capacitors. 4.1 Ratings Nominal voltage: 150 kv Nominal current: 2500 A Rated short-circuit breaking current: 40 ka Rated duration of short-circuit current: 1 second 4.2 Circuit breaker class The circuit breaker shall be a C2 class in a System with low impedance neutral earthing (effectively earthed grid) according to IEC 62271-100 (4.107) 4.3 Rated operating sequence and K pp factor The circuit breaker shall be able to perform one- and three-pole reclosure. Rated operating sequence: O-t-CO-t'-CO, Where t = 0.3 s. t' = 3 min. Document no. 13/90592-105 - ETS-50-06-05-E1 v.1 5/9

First-pole-to-clear factor: K pp = 1.5 4.4 Break time The rated break time as defined in IEC 62271-100 (3.7.135) shall be 40 ms. 4.5 Point of wave switching (POW) The individual poles of the circuit breaker shall have constant opening and closing times enabling POW switching. If POW is not used, the simultaneity for the three poles shall be 5ms as specified in IEC 62271-100. 4.6 Alarms If nothing else is specified, the following alarms shall as a minimum be available from the circuit breakers. Alarm for motor protective switch (tripped) Alarm for spring motor (disconnected) Alarm for heating (disconnected) Alarm for spring-operated mechanism, not charged Alarm for gas level (1) if the circuit breaker chamber shall be refilled SF 6 level 1 Alarm for gas level (2) in case of insufficient gas amount in the circuit breaker chamber, the circuit breaker is blocked SF 6 level 2 Alarm contacts shall be NO. 4.7 Auxiliary contacts Each circuit breaker pole shall have 8 NO and 8 NC auxiliary contacts for position indication. Auxiliary contacts shall synchronously follow the main contact s movement and accurately reflect its open and closed positions. All auxiliary contacts shall be terminated in terminal blocks in the control cabinet. The contacts shall be designed for 220 V DC ± 15%, and the contacts shall be able to break a current I n 2 A (L/R 20ms). 4.8 Connection of measuring equipment The circuit breaker shall be prepared with terminals for measuring operation times. This shall include the option of connecting measuring equipment to determine movement. 4.9 Physical dimensions High-voltage 150 kv terminals shall be placed approx. 5.5 m above the foundation. The individual circuit breaker poles shall not be wider than 1 m. 4.10 High-voltage terminals For 150 kv high-voltage terminals, one of the following is preferred: Document no. 13/90592-105 - ETS-50-06-05-E1 v.1 6/9

Plate terminals with 2x2 14 mm holes and 44.5 or 50 mm centre hole spacing. Material: Aluminium or aluminium alloy See appendix 7.1 Figure 1. Plate terminals with 2x4 14 mm holes and 44.5 or 50 mm centre hole spacing. Material: Aluminium or aluminium alloy See appendix 7.1 Figure 2. 4.11 Switching of shunt reactors, filters, cables and shunt capacitors It shall be possible to switch reactive components at a voltage 1.3 times the rated voltage. 4.12 Control voltage 220 V DC ± 15%. 4.13 Control cabinets The control cabinet shall have one 230 V AC, 10 A socket. The socket shall be protected by a RCBO (Residual Current Breaker with Overcurrent). All cabinets shall have an IP55 protection rating. Each control cabinet shall be fitted with heating elements for 230 VAC, 50 Hz. Heating elements shall not be protected by a RCBO (Residual Current Breaker with Overcurrent). The control cabinet shall be accessible from the ground, meaning that no ladder or lift is needed in order to work or do maintenance in the control cabinet. 5. Design requirements Dynamic forces during switching shall be specified for dimensioning of rigidity and strength of foundations and supporting steel structures. The supplier shall state strength and rigidity requirements. 5.1 Mechanical endurance class The circuit breakers shall be of the M2 mechanical class (10,000 operating cycles). 5.2 Corrosion protection External parts shall be made of corrosion-resistant materials. Steel components shall be stainless or hot-dip galvanized. If surfaces are processed, they shall be protected in a permanent way. Combination of materials with different electrochemical potential shall be avoided, unless sufficiently protected from moisture. 5.3 Earthing The earthing shall be constructed with two-holes for cable lugs on each frame or structure. Cabinets of insulating material shall have a common earthing terminal to which all internal separate metal parts shall be connected. There shall be terminals for protective earthing of control cabling. Document no. 13/90592-105 - ETS-50-06-05-E1 v.1 7/9

5.4 Position indicators The circuit breaker position shall be indicated mechanically at the circuit breaker poles or at the operation mechanisms. 5.5 Circuit breaker support Support most be included, the dimensions of the support structure shall be compatible with the foot print shown in Figure 3 and Figure 4 in appendix 7.1.2. 6. Documentation The circuit breaker shall be accompanied by the following documentation: data sheets for unit and equipment stating manufacture, type, description, drawings, including: Breaking capacity Current chopping and DC current breaking capacity Accumulated breaking capacity Temperature as a function of load Times, movement diagram Test certificates Mechanical data, strength, deflection, etc. Equipotential curves Detailed drawings Operating manuals Maintenance manuals Instructions for disposal Spare parts Document no. 13/90592-105 - ETS-50-06-05-E1 v.1 8/9

7. Appendices 7.1 Appendix 1 7.1.1 Drilling plan high voltage terminals Figure 1: Plate terminal 2x2 Figure 2: Plate terminal with 2x4 7.1.2 Foundation and foot print for circuit breaker stand Figure 3: Foundation top view and foot print. Figure 4: Foundation side view 24 mm bolts are used in the foundation. Document no. 13/90592-105 - ETS-50-06-05-E1 v.1 9/9