GLS 3700 6712. Sampler Selection Guide

Similar documents
The software solution to complete your flow monitoring program

HOW-TO GUIDE FOR STORMWATER MONITORING

Installation and Operation Guide

581 Rapid Transfer Device (RTD) Instruction Manual. Photo of product, with a.5 point black border

REMOTE TELEMETRY UNITS FOR CONTINUOUS WATER QUALITY MONITORING: AN EXAMPLE FROM SILVERSTREAM LANDFILL Mike Millar, Geotechnics Ltd ABSTRACT

LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER

Disposal of chemical waste must be regarded as an integral part of all research projects and teaching programs involving chemical use.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

674 Rain Gauge. Installation and Operation Guide

IP Sensing Water & Wastewater AMR/SCADA System

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

THERE S NO USE CRYING OVER SPILLED SEWAGE: USING STANDBY LIFT STATION PUMPS TO PREVENT SSOS BEFORE THEY HAPPEN

How To Get A Plan For A Water Treatment Plant

ngenieros Ingenieros Asociados De Control S.L.

Integrated Water Management in Maryland. Anwer Hasan, Senior Vice President


At the bottom of the screen you will also see some of our sister brands, all of which can also plug in to the Storm data logger.

City of Toronto Wet Weather Flow Monitoring Network: Baseline Conditions

DRAFT Public Outreach Document for What s an SSMP?

Differentiation Summary. Revolutionizing Water Clean-Up Opportunities

Automated Wireless Monitoring of Waste Water Collection Systems

Steel Spill Containment Pallets

SILICON VALLEY CLEAN WATER. May 2015

all VAC LIFT ALL-VAC-LIFT Phone Redstart Street Fax

MARYLAND AVENUE BACKUPS DURING AUGUST 31, 2014 STORM EVENT COMMUNITY OUTREACH

Source Water Protection Practices Bulletin Managing Sanitary Sewer Overflows and Combined Sewer Overflows to Prevent Contamination of Drinking Water

SECTION DETECTION AND ALARM

5800 Temperature Sensor Cable Assembly

IMPORTANT: PLEASE READ THIS MANUAL CAREFULLY AND KEEP IT IN A SAFE PLACE POOL SCOUT MANUAL

IC24. DISPOSAL OF WASTEWATER GENERATED BY MOBILE BUSINESSES AND OUTDOOR ACTIVITIES

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

Good Housekeeping BMP

Unauthorized Discharges and Sanitary Sewer Overflows

Sample specifications for an effective Flow Monitoring Services RFP

Drainage and Grease Management for the Commercial Kitchen

Building Environmental Monitoring Infrastructures

City of Dallas Wastewater Collection System: TCEQ Sanitary Sewer Outreach Agreement City Council Briefing January 17, 2007

APPENDIX B. Magna Reservoir Leak Detection & Water Quality Sampling Plan (Revised June 2011)

Stormwater Monitoring COMPLETE WATER MONITORING SOLUTIONS

John J. Cronley Marketing Communications Manager Mission Communications , x1008

WEATHER STATION FOR SOLAR FARM MONITORING

MC4-50 Feeding System

Flowlink 5.1. Software Instruction Manual

United Security Products Automatic Dialers are a NEW BREED of Security

All Products Brochure

DOC# IMBU-PB-REMOTE-MONITORING-01-EN IMBU. Remote monitoring of industrial equipment

THE SOLAR TRANSFORMER. Portable Integrated Solar Power

Florida Department of Environmental Protection

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Automated Wireless Monitoring of Waste Water Collection Systems

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

Open Channel & Partially Filled Pipe Ultrasonic Flow Meters

Even collection systems with high-performing operation and maintenance programs will eventually

API Marine. BMS Presentation. Ballast Measurement Systems

National Precast Concrete Association

Deployment of networks of innovative water quality sensors for distribution network monitoring Joep van den Broeke (Ph.D.)

APPENDIX 4 Water Quality Monitoring Program Plan

Assure Instant Communication with Two-way Radio Call Boxes...

NetScanner System. Toronto: , Montreal: , Toll Free: ,

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

LANCOM4 PORTABLE FLUE GAS MONITORING. NO NO2 NOx CO2 H2S SO2 CxHy. CO low CO high O 2 QUALITY CUSTOMER SOLUTIONS

ENAiKOON ultrasonic fuel-level sensor

Application of Subsea Wireless Technology to Environmental Monitoring

FT-1000/GPS-N. System of remote monitoring and control of physical

APPLICATION SUPPORT BULLETIN

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

How To Get A Stormwater Discharge Permit In A City Of Scottsdale

4" SUBMERSIBLE PUMPS

Why are Batteries Harmful to the Environment?

Monitoring Remote Chemical Tanks

USB-500 Series Low-Cost Data Loggers and Accessories

POLLUTION PREVENTION FACT SHEET: AUTOMOBILE MAINTENANCE

Temperature & Humidity SMS Alert Controller

EPA Region 4 Introduction to Conducting Evaluations of Municipal Wastewater Collection System Management, Operation, and Maintenance Programs

Curing Lights HALOGEN CURING LIGHTS 5.2 L.E.D. CURING LIGHTS 5.3 LIGHT GUIDES 5.5 RADIOMETERS 5.6 ACCESSORIES FOR CURING LIGHTS 5.

Tim Schneller, P.E. GBA Engineers and Architects

Sanitary Sewer Overflow Enforcement : A National Perspective

In this chart please enter Yes, No or N/A for the type of meter you are bidding.

Scattergraph Principles and Practice Characterization of Sanitary Sewer and Combined Sewer Overflows

RULE ORGANIC COMPOUNDS - WASTEWATER COLLECTION AND SEPARATION SYSTEMS

2.24. Pump Controller 704. Data Sheet

SELECT MOUNT MONITOR

Kansas City s Overflow Control Program

Wireless Data Logger Monitoring Systems

Protecting the Nation s Waters Through Effective NPDES Permits

VXT. Open Cooling Towers. Open Cooling Towers. Product Detail VXT - B 1. Engineering Data... B2. Structural Support... B6

Tank Gauging & Inventory Management Solutions

EASIDEW PORTABLE HYGROMETER INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Monitoring Water Quality For Today s Demanding World

Shunt lock function 3066

PCS300 Universal IP Reporting Module V1.0

Advanced Fuel Cells A Reliable and Green Solution to Reduce Operating Expenses of Telecommunication Networks

Massage, Heat & Air Systems

CREATING A GREEN FUTURE THROUGH WATER REMEDIATION

ABC CIRCUITS 10 Circuit Drive Circuit Town, IN SLUG CONTROL PLAN

Model 1210C Battery Powered Pump Shown. Description

Introduction To SCADA and Telemetry

INTRODUCTION AND BACKGROUND

Water Recycles poster

HACCP CONTROLLERS. Ullstrøm Fepo AS Kr. Augustsgt Oslo Tlf: Fax: MULTIFUNCTION CONTROLLERS x 74 -

Transcription:

Glacier 5800 6712FR Avalanche GLS 3700 6712 Sampler Selection Guide

Advanced Automated Sampler Products From Teledyne Isco With more than four decades of industry leadership, Teledyne Isco continues to advance automated water and wastewater sampler technology by developing durable and innovative products. We offer a wide range of samplers to meet your specific application needs. For in-depth information on Isco sampler products, contact your authorized Isco representative, or visit us on the web at www.isco.com/as. Wastewater Treatment Municipal Wastewater Treatment Industrial Pretreatment Collection Systems Combined Sewer Overflows (CSOs) Sanitary Sewer Overflows (SSOs) Industrial Pretreatment Monitoring Enforcement Monitoring Water Quality Monitoring Stormwater Surface Water Reservoirs Recreation Water Total Maximum Daily Load (TMDL) Watershed Monitoring Communications and Data Handling Today s communication, parameter measurement, and software technologies bring many advances and efficiencies to water and wastewater sampling. Contact your Isco representative for more information on: Data communications RS-232, 4-20 ma, SCADA, Modbus, cellular wireless, spread-spectrum radio, and alarm notifications Parameter measurement level, ph, temperature, turbidity, conductivity, and more for sample triggering and data logging Software automate your data analysis and reports Special Product Applications Teledyne Isco s Special Product Applications (SPA) team customizes automated sampling equipment to meet the unique needs of our customers around the world. Specialized communications, pressurized sampling, and extended lift heights are only a few of the many solutions we develop. Contact us with your challenging applications. Use Flowlink software to collect, analyze, and report all of the data from your monitoring program.

Teledyne Isco Sampler Suitability Guide Isco Recommends 5800 6712FR GLS 3700 6712 Glacier Avalanche Refrigerated Refrigerated Portable Portable Portable Portable Refrigerated Portable Refrigerated Wastewater Treatment X X* Collection Systems Water Quality Monitoring X X X* X X* X* X* * Add flow or parameter measurement capability 701 ph/temperature 730 Bubbler Flow 780 4-20 ma Analog Input 720 Submerged Probe Flow 750 Area Velocity Flow AQ700 Series Multi-Parameter Sondes

Options and Accessories Selection Guide (continued) Suction Line Vinyl Suction Line If using plastic bottles, select vinyl suction line. Vinyl suction line should be replaced as necessary. Black Tygon Suction Line Algae-resistant suction line can be used for general purpose sampling. (Not EPA approved.) PTFE-lined Suction Line If using glass bottles, select PTFE-lined suction line. This chemically inert line can be cleaned and reused often. Strainers Stainless Steel and Polypropylene For most sampling applications using plastic bottles with vinyl suction lines. Stainless Steel For use with glass bottles and PTFE-lined suction lines when sampling for metals is not a requirement. CPVC Usually selected when sampling corrosive liquids. PTFE-coated Stainless Steel The choice when other strainer materials are not compatible. Low Flow Stainless Steel For depths as low as two inches (5 cm). Ultra-low Flow Stainless Steel For depths as low as one inch (2.5 cm) requires ¼-inch tubing. Bottles, suction lines, and strainers contact the sample liquid. Always select wetted materials that are compatible with the sample analysis.

Options and Accessories Selection Guide Teledyne Isco offers many options and accessories which allow you to configure the sampler for your specific application. Portable Sampler Power When AC power is present, use Isco power packs to convert AC power to 12 volts DC for the portable sampler. When AC power is not present at the site, select a battery. Standard AC Power Packs Available for 120 and 240 VAC power Battery-backed AC Power Packs For uninterruptible operation in critical applications Nickel Cadmium Batteries 4 amp/hour power for short-term sampling with easy recharging Lead-acid Batteries 6.5 and 45 amp/hour battery for short- and long-term sampling Solar Panels Extend your remote sampling applications by keeping batteries charged for the next event Charging Stations Designed for optimum charging and maximum discharge/recharge cycles Bottles When selecting bottles for a sampler, consider the bottle material and configuration. To choose either plastic or glass bottle material, refer to the Code of Federal Regulations 40 CFR 136.3 Table II. This table specifies acceptable containers based on tests to be performed on the collected sample liquid. Governing directives may also specify bottle configurations. Typical bottle configurations include: 1 Composite Bottle Compliance monitoring for wastewater discharge monitoring 4 Sequential Bottles Compliance monitoring for stormwater run-off permits 24 Sequential Bottles Process control and enforcement monitoring

4700 Superior Street Lincoln, NE 68504 USA Phone: (800) 228-4373 (402) 464-0231 Brochure L-1148 2014 Teledyne Technologies Incorporated www.isco.com