Digital Lighting Systems, Inc.

Similar documents
Visa Smart Debit/Credit Certificate Authority Public Keys

NSI DIGITAL DIMMING SYSTEM DDS 9800 DIMMER PACKS

Applied Electronics. Commercial Dimming System UPDATE NOTICE

Advantium 2 Plus Alarm

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Operation and Installation Manual

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

INSTALLATION INSTRUCTIONS

BACnet Automation Interface Module (Network Version)

LOXONE 12 Channel Amplifier

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

Contents. Safety Warnings... 1

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Single Station Remote Alarm

VX 2400 Dimmer User's Manual

Single Phase Soft Starter

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

CompactLogix Power Supplies Specifications

How To Test A Power Distribution Unit

T O K I S T A R L I G H T I N G I N S T R U C T I O N M A N U A L LC-1CH-MULTI Dimmer Module

Freeze Protection Thermostats MODELS SST 2. Installation and Operation Manual

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

HMI display Installation Guide

LIEBERT VNSA Installation Sheet

Installation and Operation Guide for PD4000 Series Power Control Center

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

STAGE SETTER-8. User Instructions. Elation Professional

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

AMU PROFESSIONAL VIDEO AND AUDIO MONITORING UNIT OPERATOR'S HANDBOOK ISSUE A3

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

MechoNet TM Network Interface (MNI) Specification Submittal

Canopy Surge. User Manual

VK-250 WARRANTY REGISTRATION FORM

T-Extender E-Extender

Installation and Operation Guide for PD4100 Series Power Control Centers

INSTALLATION & SERVICE MANUAL. Display Panel

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

OPLC Installation Guide

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

Load Cell Amplifier Module. Instruction Manual LCA

Contractors Guide Central Inverter System Installation

Comfort Control Relay Panel (CCRP)

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Lionel O-27 Gauge 27 Path Remote-Control Switch Owner s Manual

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

AXIS T81B22 DC 30W Midspan

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Utility Distribution Systems

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

TG24 / 48 LIGHTING CONTROLLER

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

InHome Water Leak Detection Package

INSTALLATION. Omega 8000 Series Controller For Use With Omega 90 Siren/P.A. Amplifier

, User s Manual

Installation Instructions

Installation and Operation Guide PD4600 Series Converter Replacement

UniStream CPU-for-Panel

INSTRUCTION MANUAL MODEL PCD-88

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

High Bay Occupancy Sensor Selection Guide

PUSH CV. Vi säljer och konsulterar Ledbelysning. Utebelysning Innebelysning Led-strip RGB Drivdon. SÄLJKONTOR Torstensviksvägen Frillesås

Installation and Operating Manual

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Instructions for Connecting PETROSMART EZ Control Systems To Wayne Electronic Dispensers With/Without CAT CREDIT CARD MODULES

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Parallel Redundant Uninterruptible Power Supply

Snapshot. LEDrain 38 USER MANUAL. Ok on Dimmer. Outdoor OK. Sound Activated. DMX/Master/Slave. 115V/230V Switch. Replaceable Fuse.

DCX300 - DCX400 - DCX600

16/32 Channel 1U Rack Mount CCTV Power Supply

PSC POWER STAR LiFE TM

SECTION LOW VOLTAGE LIGHTING CONTROLS

AUTOMATIC BEST BATTERY SELECTOR INSTALLATION & OPERATION BBS-1600 BBS-1600E

HP UPS R1500 Generation 3

THE MclNTOSH MC 2100 SOLID STATE STEREO POWER AMPLIFIER

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

DMX-K-DRV. Integrated Step Motor Driver + (Basic Controller) Manual

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

USER MANUAL. MODEL 460 Series G.703 Coax to Twisted Pair Adapter (Balun)

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

1080P. Extender for HDMI over one CAT5. GTV-HDBT-CAT5 User Manual. gefentv.com

Nest Learning Thermostat Installation Guide. Installation step-by-step

USB HID to PS/2 Scan Code Translation Table

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

REV. REL 1302 WEST BEARDSLEY AVENUE P.O. BOX 1127 ELKHART IN (574) FAX (574) ELKHART BRASS MFG. CO., INC.

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

SERVER CERTIFICATES OF THE VETUMA SERVICE

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

NC-12 Modbus Application

PART 8: FIELD WIRING. n WARNING NOTICE. Boiler Manual

LED MOTION ACTIVATED FLOOD LIGHT

2X1 DVI Switch (DS-21R) 4X1 DVI Switch (DS-41R) USER MANUAL. DTronics Inc.

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

USER MANUAL. Kramer Electronics, Ltd. Models:

Transcription:

Digital Lighting Systems, Inc. PD26-DMX Two Channel DMX Dimmer Pack (includes information for PD26-DMX-S) PD26-DMX S2 S 2 USER'S MANUAL PD26-DMX-UM 0/0

2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page GENERAL DESCRIPTION The PD26-DMX is a 2-channel DMX-52 compatible dimmer pack. It contains two printed circuit boards, the load driver module (LDM) and the INT0 control module. The LDM is equivalent to two solid-state relays (SSR's) assembled on a single circuit board. Power is fed to the PD26-DMX from two 20 Amp. breakers on the same electrical phase. Each breaker feeds a relay and each relay is rated for a maximum output current of 6 amperes. The LDM is mounted at the bottom of the PD26-DMX's enclosure which also serves as a heat sink. The relays are triggered by low-voltage signals generated by the INT0 module. These signals are optically-isolated by the LDM circuitry from all line voltage elements. A stepdown 0 VAC- transformer on the LDM board supplies power to the INT0. DMX-52 control information is received by the INT0 over a shielded twisted-pair cable. Several PD26-DMX dimmer packs may be daisy-chained together using standard DMX cables with 5-pin XLR type connectors. Each PD26-DMX may be set to a unique address and will occupy the next two DMX control channels beginning with the address selected at the front panel. When two or more units are set to the same address, their respective outputs work in unison, increasing the amount of load that can be controlled by a single DMX channel. Each of the PD26- DMX outputs may be independently configured not to dim. In such case, a DMX input value greater than switches its respective output to 00%, else the output remains at 0%. Figure shows a functional block diagram of the PD26-DMX. Figure shows PD26-DMX dimmers in a typical installation. DIMMING/SWITCHING - (See Page 8 for more information) A PD26-DMX may control a combination of dimmed and switched loads. Both of the PD26-DMX s outputs may be independently configured not to dim. This is achieved using a HARDWARE lock to ensure circuits do not dim. Both outputs controlled by the INT0 may be configured not to dim by the installation of a small jumper on the back of the INT0 circuit board. This may be done at the factory or in the field. This jumper may be removed to allow the future dimming of those outputs. Please see Page 8 for location of this jumper. Alternatively, the PD26-DMX may be ordered as a SWITCH-ONLY unit, the PD26-DMX-S. This unit has all the same features as the PD26 except that there is no dimming, and there are no chokes installed inside the unit. All other information in this manual is the same for both the PD26 and the PD26-S. 7588 NW 8th Street, Miami, Fl. 26 Tel: 05-26-89 or -877-26-89 Fax: 05-26-667 PD26-DMX-UM 0/0

2 5 2 5 BCDEF0256789A BCDEF0256789A 2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page 2 PD26-DMX Load Driver Module Information Figure - PD26-DMX LDM Detail INT0 Control Board J LDM SSR's OPTICAL ISOLATORS 5-Pin XLR Connectors Ground Load Driver Module SSR 9 VAC Transformer SSR NEUTRAL BUS Earth Ground H N N2 N N N5 N6 H2 Table - Terminals Definition NAME DESCRIPTION Output Of Solid-State Relay # Output Of Solid-State Relay # H Hot Line Feed For Relay. H2 Hot Line Feed For Relay. N-N6 Neutral Bus Connections. Table 2 - Absolute Maximum Electrical Ratings Electrical Characteristic Terminal Maximum Relay Load Current & 6 Amps. Input Current For Relay H 20 Amps. Input Current For Relay H2 20 Amps. Input Voltage H-H2 20 VAC, -Phase. PD26-DMX: INT0 Detail Table - INT0 Circuit Legend INT0 Circuit Legend Microprocessor. 2 Nonvolatile Memory. Communications Chip. Quartz Crystal. 5 Power Supply Capacitor. 6 Voltage Regulator. 7 Signal & Power Connector. 8 Output LED Monitors. S-2 Address Selectors. S Address Expansion 5 Components Side INT0 S2 6 2 8 S S 7 S Address Expansion Jumper (S) On Solder Side Solder Side INT0 2 S S2 8 S 6 7 5 NOTE: PD26-DMX has one INT0 control board. Figure 2 - PD26-DMX INT0 Detail 7588 NW 8th Street, Miami, Fl. 26 Tel: 05-26-89 or -877-26-89 Fax: 05-26-667 PD26-DMX-UM 0/0

2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page Figure - PD26-DMX Dimensional Diagram 8.0" (2 mm) Bottom View /2 and / Conduit Knockouts.2" (05 mm) IN 5 2 OUT 5 2 Top View.9" (8 mm) 2.600" (66 mm) DMX Ports 2.5" (55 mm) 2" (5 mm) 2" (5 mm) 2.5" (55 mm) 2.000" (5 mm).500" (8 mm) 5" (27 mm) LDM - Load Driver Module H 2 N N2 N N N5 N6 H2.07" (28 mm) T T.75" (298 mm) ADDRESS SELECTORS INT0 S2 S C 0 VAC Transformer W J 8 5" (27 mm) LED's OPTO-ISOLATORS 2 W2 J J2 0 0 PD26-DMX ( LDM) Load Driver Module C 0.75" (9 mm) LED OUTPUT MONITORS 2 PD26-DMX Front Cover Enclosure Installation Surface mount the dimmer pack in a well ventilated area where the ambient temperature does not exceed 90 F for full load operation. Allow " of side clearance for proper air circulation. Installation clearance shall meet local and/or NEC code requirements. Enclosures may be attached to the wall or other mounting surface by holes in the heat sink flanges. Refer to the drawings above for the proper dimensions. Conduit shall be pulled to the top of the dimmer packs. NOTE The PD26-DMX may create a buzzing noise and should not be located where this is objectionable. Figure - Typical Installation DMX CONTROL EQUIPMENT #2 AWG Typical To Distribution Panel PD26-DMX To Loads #2 AWG Typical To Distribution Panel PD26-DMX DMX-CC-LEN -Standard DMX Cable with 5-pin XLR Connectors To Loads Table - XLR DMX Connectors Pin Assignment Pin Function Pin No. Ground Shield -DATA 2 +DATA Empty Empty 5 5 5 2 2 OUT IN 7588 NW 8th Street, Miami, Fl. 26 Tel: 05-26-89 or -877-26-89 Fax: 05-26-667 PD26-DMX-UM 0/0

2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page PD26-DMX-20 General Wiring Instructions Wiring Notes 0 DO NOT EXCEED 920 W (6 Amps. ) per dimmer output @ 20VAC. 0 All wiring between the dimmers and controller (network bus) is low voltage (NEMA Class 2) and may be run with two, twisted pair, shielded #8 AWG wire. 0 PD26-DMX dimmer packs may be fed by one or two 20 A (maximum) branch circuits and may have up to two separately dimmed/switched loads. 0 Both breakers must be on the same power phase. 0 CAUTION: DO NOT attempt to parallel outputs to increase capacity. 0 Installations must conform to local and/or NEC code requirements. 0 Each load must have its own Neutral wire for full load operation. 0 All line voltage wires must have copper conductors of adequate Gauge with 90 C wire insulation. 0 POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE PD26-DMX TO ENSURE PROPER WIRING. Figure 5 - PD26-DMX Typical 20 VAC Wiring. CAUTION PD26-DMX-20 VAC Models ONLY INT0 Control Board LDM SSR's OPTICAL ISOLATORS Load Driver Module SSR 9 VAC Transformer SSR NEUTRAL BUS H N N2 N N N5 N6 H2 LOAD # To Distribution Panel Neutral Bus LOAD #2 Earth Ground Electrical Distribution Panel ON ON 2x20 A - 20 VAC Breakers On Same Phase J For Full Load Operation Use: #2 AWG copper conductor wire for Line & Neutral Feeds. # AWG copper conductors in/out to each load. Max. Load: 6 Amperes (920W at 20 VAC). 7588 NW 8th Street, Miami, Fl. 26 Tel: 05-26-89 or -877-26-89 Fax: 05-26-667 PD26-DMX-UM 0/0

PD26-DMX 2-Channel Dimmer Pack Digital Lighting Systems User's Manual - Page 5 PD26-DMX-220 General Wiring Instructions Wiring Notes 0 DO NOT EXCEED 80 W (6 Amps. ) per dimmer output @ 20VAC. 0 All wiring between the dimmers, and controller (network bus) is low voltage (NEMA Class 2) and may be run with two, twisted pair, shielded #8 AWG wire. 0 PD26-DMX dimmer packs may be fed by one or two 20 A (maximum) branch circuits and may have up to two separately dimmed.switched loads. 0 Both breakers must be on the same power phase. 0 CAUTION: DO NOT attempt to parallel outputs to increase capacity. 0 Installations must conform to local and/or NEC code requirements. 0 Each load must have its own Neutral wire for full load operation. 0 All line voltage wires must have copper conductors of adequate Gauge with 90 C wire insulation. 0 POWER EACH LOAD DIRECTLY BEFORE CONNECTING IT TO THE PD26-DMX, TO ENSURE PROPER WIRING. Figure 6 - PD26 Typical 220/20 VAC Wiring. CAUTION PD26-220/20 VAC Models ONLY INT0 Control Board LDM SSR's OPTICAL ISOLATORS Load Driver Module SSR 9 VAC Transformer SSR NEUTRAL BUS H N N2 N N N5 N6 H2 LOAD # To Distribution Panel Neutral Bus LOAD #2 Earth Ground Electrical Distribution Panel ON ON 2x20 Amp 220 to 20 VAC Breakers On Same Phase J For Full Load Operation Use: #2 AWG copper conductor wire for Line & Neutral Feeds. # AWG copper conductors in/out to each load. Max. Load: 6 Amperes (80W at 20 VAC). 7588 NW 8th Street, Miami, Fl. 26 Tel: 05-26-89 or -877-26-89 Fax: 05-26-667 PD26-DMX-UM 0/0

2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page 6 Figure 7 - PD26-DMX-2/2 Low Voltage Load and Power Wiring CAUTION PD26-DMX-2/2 Models ONLY Electrical Distribution Panel NEUTRAL X PRIMARY SECONDARY ON 2v or 2v Transformer X LDM Load Driver Module SSR H LOAD # INT0 Control Board SSR's OPTICAL ISOLATORS Voltage Divider Network NEUTRAL BUS N N2 N N N5 N6 SSR H2 LOAD #2 J For Full Load Operation Use: #2 AWG copper conductor wire for Line & Neutral Feeds. # AWG copper conductors in/out to each load. Max. Load per circuit : 6 Amperes (8W at 2 VAC). NOTES With PD26-DMX-2 you may use a single 2 VAC-800 VA or better transformer or two separate 2 VAC-00 VA or better transformers. 2 With PD26-DMX-2 you may use a single 2 VAC-00 VA or better transformer or two separate 2 VAC-200 VA or better transformers. Follow transformer's installation & wiring instructions from manufacturer. Maximum Load Per Output: 92 Watts at 2 VAC. 5 Maximum Load Per Output: 8 watts at 2 VAC. 7588 NW 8th Street, Miami, Fl. 26 Tel: 05-26-89 or -877-26-89 Fax: 05-26-667 PD26-DMX-UM 0/0

5 6 8 S2 S 7 2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page 7 DMX Address Setting Up to 256 PD26-DMX dimmer packs may be installed per system and their DMX input daisy-chained using standard DMX-52 cables. Different addresses ranging from to 5 may be selected for each dimmer, depending on which DMX channel(s) will be used to control it. Each dimmer pack uses 2 consecutive DMX bytes from the input stream beginning at the address selected using rotary selectors S, S2 and address expansion jumper S. (See Figure on page 2 for selectors location). The PD26-DMX is shipped from the factory with jumper S installed allowing a DMX address range between and 256 to be selected by S & S2 (See Table ). For higher addresses ( 257-509) jumper S must be removed (See Table 5). Non-Dim Output Setting Either or both of the PD26-DMX outputs may be configured for non-dim (switch only) operation. This prevents inadvertent dimming, or damage, of loads that cannot be dimmed, such as contactors, mechanical relays, motors, non-dim fluorescent, etc... Since this procedure involves adding external wire jumpers to the INT0 board, it is preferable to have it performed by the factory, at time of order. However, a qualified electronic technician can perform the procedure in the field when necessary. Figure 8 shows the location for installing the non-dim (ND) jumpers. The numbers shown next to the ND jumpers represent the corresponding output number of the PD26- DMX. Installing an ND jumper makes the corresponding output non-dim (switch only). A DMX value greater than turns a non-dim output to full intensity. A DMX value of or less turns it fully off. BEFORE ENERGIZING THE PD26-DMX MAKE SURE: 0 Loads are tested before connecting to dimmers. 0 Breaker feed lines are on same electrical phase. 0 PD26-DMX has been properly grounded. 0 All line voltage screw terminals are properly tightened to prevent hot spots. 0 Low voltage data lines connections are properly insulated. 0 Low voltage data lines polarity is observed throughout the system. 0 The PD26-DMX is set to the right address. INT0 Solder (Back) Side INT0 2 ND ND2 Non-Dim Jumpers ND-ND2 Installed Output Is Non-Dim (Switch Only) Removed Normal Dimmer Output. 0 5 Unit is shipped without ND jumpers. Address Expansion Jumper (S) Installed (S2,S) Address Range: -256 Removed (S2,S) Address Range: 257-509 S Figure 8 - PD26-DMX Address & Mode Selection. 7588 NW 8th Street, Miami, Fl. 26 Tel: 05-26-89 or -877-26-89 Fax: 05-26-667 PD26-DMX-UM 0/0

2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page 8 PD26-DMX Address Selection Information Table - Addresses -256 Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S 00 20 65 0 97 60 29 80 6 A0 9 C0 225 E0 2 0 2 66 98 6 0 8 62 A 9 C 226 E 02 5 22 67 2 99 62 82 6 A2 95 C2 227 E2 0 6 2 68 00 6 2 8 6 A 96 C 228 E 5 0 7 2 69 0 6 8 65 A 97 C 229 E 6 05 8 25 70 5 02 65 85 66 A5 98 C5 20 E5 7 06 9 26 7 6 0 66 5 86 67 A6 99 C6 2 E6 8 07 0 27 72 7 0 67 6 87 68 A7 200 C7 22 E7 9 08 28 7 8 05 68 7 88 69 A8 20 C8 2 E8 0 09 2 29 7 9 06 69 8 89 70 A9 202 C9 2 E9 0A 2A 75 A 07 6A 9 8A 7 AA 20 CA 25 EA 2 0B 2B 76 B 08 6B 0 8B 72 AB 20 CB 26 EB 0C 5 2C 77 C 09 6C 8C 7 AC 205 CC 27 EC 0D 6 2D 78 D 0 6D 2 8D 7 AD 206 CD 28 ED 5 0E 7 2E 79 E 6E 8E 75 AE 207 CE 29 EE 6 0F 8 2F 80 F 2 6F 8F 76 AF 208 CF 20 EF 7 0 9 0 8 50 70 5 90 77 B0 209 D0 2 F0 8 50 82 5 7 6 9 78 B 20 D 22 F 9 2 5 2 8 52 5 72 7 92 79 B2 2 D2 2 F2 20 52 8 5 6 7 8 9 80 B 22 D 2 F 2 5 85 5 7 7 9 9 8 B 2 D 25 F 22 5 5 5 86 55 8 75 50 95 82 B5 2 D5 26 F5 2 6 55 6 87 56 9 76 5 96 8 B6 25 D6 27 F6 2 7 56 7 88 57 20 77 52 97 8 B7 26 D7 28 F7 25 8 57 8 89 58 2 78 5 98 85 B8 27 D8 29 F8 26 9 58 9 90 59 22 79 5 99 86 B9 28 D9 250 F9 27 A 59 A 9 5A 2 7A 55 9A 87 BA 29 DA 25 FA 28 B 60 B 92 5B 2 7B 56 9B 88 BB 220 DB 252 FB 29 C 6 C 9 5C 25 7C 57 9C 89 BC 22 DC 25 FC 0 D 62 D 9 5D 26 7D 58 9D 90 BD 222 DD 25 FD E 6 E 95 5E 27 7E 59 9E 9 BE 22 DE 255 FE 2 F 6 F 96 5F 28 7F 60 9F 92 BF 22 DF 256 FF Table 5 - PD26-DMX Decimal to Hexadecimal Address Chart. Address Selection Chart Using S2-S with JUMPER INSTALLED 7588 NW 8th Street, Miami, Fl. 26 Tel: 05-26-89 or -877-26-89 Fax: 05-26-667 PD26-DMX-UM 0/0

2-Channel Dimmer Pack Digital Lighting Systems PD26-DMX User's Manual - Page 9 PD26-DMX Address Selection Information Table 5 - Addresses 257-509 Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Cha. Select Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S Addr. S2 S 257 00 289 20 2 0 5 60 85 80 7 A0 9 C0 8 E0 258 0 290 2 22 5 6 86 8 8 A 50 C 82 E 259 02 29 22 2 2 55 62 87 82 9 A2 5 C2 8 E2 260 0 292 2 2 56 6 88 8 20 A 52 C 8 E 26 0 29 2 25 57 6 89 8 2 A 5 C 85 E 262 05 29 25 26 5 58 65 90 85 22 A5 5 C5 86 E5 26 06 295 26 27 6 59 66 9 86 2 A6 55 C6 87 E6 26 07 296 27 28 7 60 67 92 87 2 A7 56 C7 88 E7 265 08 297 28 29 8 6 68 9 88 25 A8 57 C8 89 E8 266 09 298 29 0 9 62 69 9 89 26 A9 58 C9 90 E9 267 0A 299 2A A 6 6A 95 8A 27 AA 59 CA 9 EA 268 0B 00 2B 2 B 6 6B 96 8B 28 AB 60 CB 92 EB 269 0C 0 2C C 65 6C 97 8C 29 AC 6 CC 9 EC 270 0D 02 2D D 66 6D 98 8D 0 AD 62 CD 9 ED 27 0E 0 2E 5 E 67 6E 99 8E AE 6 CE 95 EE 272 0F 0 2F 6 F 68 6F 00 8F 2 AF 6 CF 96 EF 27 0 05 0 7 50 69 70 0 90 B0 65 D0 97 F0 27 06 8 5 70 7 02 9 B 66 D 98 F 275 2 07 2 9 52 7 72 0 92 5 B2 67 D2 99 F2 276 08 0 5 72 7 0 9 6 B 68 D 500 F 277 09 5 7 7 05 9 7 B 69 D 50 F 278 5 0 5 2 55 7 75 06 95 8 B5 70 D5 502 F5 279 6 6 56 75 76 07 96 9 B6 7 D6 50 F6 280 7 2 7 57 76 77 08 97 0 B7 72 D7 50 F7 28 8 8 5 58 77 78 09 98 B8 7 D8 505 F8 282 9 9 6 59 78 79 0 99 2 B9 7 D9 506 F9 28 A 5 A 7 5A 79 7A 9A BA 75 DA 507 FA 28 B 6 B 8 5B 80 7B 2 9B BB 76 DB 508 FB 285 C 7 C 9 5C 8 7C 9C 5 BC 77 DC 509 FC 286 D 8 D 50 5D 82 7D 9D 6 BD 78 DD 50 N/A 287 E 9 E 5 5E 8 7E 5 9E 7 BE 79 DE 5 N/A 288 F 20 F 52 5F 8 7F 6 9F 8 BF 80 DF 52 N/A Table 6 - PD26-DMX Decimal to Hexadecimal Address Chart. Address Selection Chart Using S2-S with JUMPER REMOVED 7588 NW 8th Street, Miami, Fl. 26 Tel: 05-26-89 or -877-26-89 Fax: 05-26-667 PD26-DMX-UM 0/0

LIMITED WARRANTY Digital Lighting Systems, warrants to the purchaser that its products have been carefully manufactured and inspected and are warranted to be free from defects of workmanship and materials when used as intended. Any abuse or misuse contrary to normal operation shall void this warranty. Digital Lighting Systems' obligation under this warranty shall be limited to replacement or repair of any units as shall within two years of date of invoice from Digital Lighting Systems, prove defective; and Digital Lighting Systems shall not be liable for any other damages, whether direct or consequential. The implied warranties of merchantability and fitness for a particular purpose are limited to the duration of the expressed warranty. Some states do not allow the exclusion of the limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, you may also have other legal rights which vary from state to state. Upon request, replacement unit(s) will be shipped as soon as available. Unless immediate shipment of replacement merchandise is requested, Digital Lighting Systems will not ship replacement merchandise until defective merchandise is received, inspected, and determined to be defective. No labor charges in connection with warranty problems will be reimbursed by Digital Lighting Systems without prior written approval from the factory. Digital Lighting Systems distributors and representatives have no authority to change this warranty without written permission. Digital Lighting Systems reserves the right to determine the best method of correcting warranty problems. Defective merchandise may be returned to Digital Lighting Systems, prepaid, after prior notification has been given and approval obtained for the return. To obtain prior approval for the return of the defective items, contact your local Digital Lighting Systems distributor, representative, or: Digital Lighting Systems, Inc. Attn: Customer Service Department 7588 NW 8th Street Miami, FL 26 (05) 26-89

Digital Lighting Systems, Inc. 7588 NW 8th Street Miami, FL 26 www.digitallighting.com Tel 05-26-89 Fax 05-26-667 e-m info@digitallighting.com Printed in U.S.A. April 200