Certification: Residential Building Inspector. Exam ID: B1

Similar documents
Certification: Building Plans Examiner. Exam ID: B3

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

Uncovered Decks & Porches

Basic Requirements for Residential Plan Review _

COMMONLY USED RESIDENTIAL BUILDING CODES

POST AND FRAME STRUCTURES (Pole Barns)

Residential Deck Safety, Construction, and Repair

Georgia Association of Home Inspectors

INFORMATION BULLETIN NO.

2014 FLORIDA BUILDING CODE

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

The Lambton County Homeowner's BUILDING PERMIT INFORMATION GUIDE

REVEWED BY: Ross Rogien B.O/P.R. ADDITIONAL REVIEW(S) REQ.-FIRE DEPT Y/N

Residential Decks. Planning and Development Services Department

COMMERCIAL PLAN SUBMISSION FOR NEW CONSTRUCTION AND/OR RENOVATIONS

Chapter 3 Pre-Installation, Foundations and Piers

How To Make A House Safe

INFORMATION BULLETIN NO.

CITY OF BERKELEY BUILDING PERMIT DETAILED CHECKLIST

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Building Code Clarifications - 7. Fire Resistance

Sample Drawing Package for One and Two Family Dwelling Applications

BUILDING SAFETY UNIT

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

October 6, (B) the vantage point from which the crawl space was inspected; and

BUILDING PERMIT SPECIFICATIONS

Superform Products Ltd.

Residential Building Inspection Policies

MICHIGAN RESIDENTIAL CODE 2003

PDmB, Inc. Definitions

Mobile Home Pre-Inspection Checklist

Building Information Packet

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

ICC-ES Evaluation Report Reissued September, 2010 This report is subject to re-examination in one year.

Structure Survey Findings:

STRUCTURAL ASSESSMENT. Full Metal Jacket Building 0 Prince Street, Alexandria, VA

Residential Building Permits

Residential Plan Routing Information

Residential Building Permit Process

MANUFACTURED HOUSING USED AS DWELLINGS

Footing and Temporary Power Inspection

CHAPTER 6 CONSTRUCTION TYPES

STANDARD OPEN PATIO COVER

PLEASE RETURN DENIAL COMMENTS WHEN RESUBMITTING PLANS*

New Ontario Building Code Highlights

City of Oviedo Commercial Shell Building Permit Application Guidelines

Patio Covers / Carports

Mark Cramer Inspection Services, Inc.

Chapter LINCOLN RESIDENTIAL BUILDING CODE

CHIMNEYS AND FIREPLACES

Building, Plumbing, Electrical and Residential Water and Sewer Inspection Requirements

FIRE AND SMOKE PROTECTION FEATURES

CALIFORNIA BUILDING CODE

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Name of course: Residential Construction Site Management (RCSM) Level 1

VOLUSIA COUNTY GROWTH & RESOURCE MANAGEMENT BUILDING ACTIVITY

Building Condition Assessment Report

Uniform Construction Code (UCC) Building Permit Application Package

5.0 wall ApplicAtions

SUPPORTING DOCUMENT PLAN REVIEW GUIDE RESIDENTIAL CONSTRUCTION

Page & Turnbull imagining change in historic environments through design, research, and technology

Pre-Drywall Inspection Report

Development Services Department Building Permit & Inspection Services Shed and Garage Construction Guide for Detached and Semi-Detached Dwellings

FIRE AND SMOKE PROTECTION FEATURES

Significant Code Changes to the 2009 International Residential Building Code

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Does Wall Township require an inspection by the building department on resale of a home?

St. Louis County Department of Public Works Division of Code Enforcement. When is a Building Permit required for Residential Projects?

Self-Home Inspection Checklist

Engineered Wood Foundations

ISO Types 1-6: Construction Code Descriptions

RESIDENTIAL SITE INSPECTIONS

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

CLACKAMAS COUNTY DEPARTMENT OF TRANSPORTATION AND DEVELOPMENT BUILDING CODES DIVISION R E S I D E N T I A L C O D E S U M M A R Y

201 WATER STREET FORWARDERS MUSEUM AND VISITORS INFORMATION CENTRE

VILLAGE OF HUDSON FALLS 220 MAIN STREET HUDSON FALLS, NY (518) /

GENERAL BUILDING PERMIT INFORMATION FOR: RESIDENTIAL ALTERATIONS & ADDITIONS

Building Permit Application Packet. BUILDING CODES Adopted by La Plata County For Enforcement In The Unincorporated Areas Of La Plata County

The minimum reinforcement for the stem wall is the placement of:

Elevating Your House. Introduction CHAPTER 5

Ontario s 2012 Building Code Division B, Part 9 (Ontario Regulation 332/12)

Chapter 6 ROOF-CEILING SYSTEMS

The Residential Code of New York State Instructor:

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

Substantial Improvement/Damage (FEMA 50% Rule) Frequently Asked Questions and Information

Building Code Inspections and Fees

RESIDENTIAL BUILDING CODE HANDOUT REFERENCES: 2009 Michigan Residential Code

Single Family Residential Building Permit Questions & Answers

Residential Inspection Guidelines

The Closed Crawl Space: Making the Transition Climate Zones 3A & 4A

Building Condition Assessment: North Howard Street Baltimore, Maryland

SECTION R319 PROTECTION AGAINST DECAY R319.1 Location required. In areas subject to decay damage as established by Table R301.2(1), the following

Building Department John Fiedler Construction Official Ext SAMPLE GUIDE FOR 1&2 FAMILY DWELLING BASEMENTS Rev

Development Services City of Lawrence, KS

Antrim County Building Department

When is a Permit Required? What Types of Permits are Required? The most common types of projects that require permits are:

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

Building Condition Assessment: West Lexington Street Baltimore, Maryland

Transcription:

Certification: Residential Building Inspector Exam ID: B1 Scope: A Residential Building Inspector will be responsible for performing inspections of structures to determine compliance with the various Building Codes and Standards adopted by his / her jurisdiction. At this level of certification, the Inspector shall be able to inspect one-and-two family dwellings, townhomes not more than three stories in height, and accessory structures. 60 multiple-choice questions 2-hour limit Open book 01 Code Administration 0101 Project Administration 4% Verify that project information is provided and is adequate. Verify that the project is designed by approved persons when required, and has required approvals. Verify that products not detailed in the building code are approved by the building official and installed according to their listing. Verify that the required approved plans and specifications are available when required and retained by the building official for the period required. 2% 0102 Public Information and Legal 2% For new and existing structures, answer questions about the need for permits and inspections, general code compliance of designs, procedures, and materials. Communicate, issue, and maintain inspection reports, correction notices, stop work orders, and data for the issuance of the certificate of occupancy. 02 Building Planning 8% 0201 Unit Separation 3% Verify that the unit separation is in compliance with the code and tested assembly requirements. Verify that unit separation walls and floor/ceiling assemblies are located where required and have correct fire-resistance. 0202 Building Location 3% Inspect the construction site to see that the building or structure location is in compliance with the requirements of the local ordinances, fire separation regulations, and the site plan. Verify that final grade will provide the required slope away from the footing or foundation wall. Verify finish floor elevation in flood-hazard areas for compliance with local and federal requirements. 0203 Room and Opening Dimensions 2% Verify that the actual and allowable floor area calculations are correct. Inspect for compliance that the room dimensions and openings are minimum for light and ventilation.

03 Footings and Foundations 16% 0301 Footings 5% Verify that the building site's soil load-bearing capacity and stability complies with approved plans or reports. Verify that footings are laid out with correct depth, size, and setbacks, and that footings extend below the frost line. Inspect footing drains for basements and crawl spaces for compliance with the code. Verify that materials used in footings and foundations are in compliance with approved plans and code requirements. 0302 Stepped Footings and Special Foundations 3% Verify that stepped footings and specialized foundations are used as per the approved plans or code. 0303 Columns and Piers 3% Verify that columns and piers are correctly supported and anchored, and that wood members are protected against termites and decay. 0304 Site Preparations, Foundation, and Basement Walls 5% Verify that the area within the foundation walls is properly prepared. Verify that foundation stem walls are correctly sized and have sufficient height above grade. Verify that foundation wall materials, reinforcement, anchor bolts, and fasteners are correct type, size, and grade and are placed in accordance with building code requirements. Verify that foundation dampproofing and waterproofing is installed where required. Verify maximum unbalanced fill height. Verify that foundation and basement walls are properly braced prior to backfill. 04 Floor Construction 14% 0401 Lumber Quality - Floors 3% Verify that wood materials are in compliance with the markings, standards, and the material characteristics. Verify that the cutting, notching, and borings are within the limitations permitted by code, and that wood members are protected against termites and decay where required. 0402 Floor Joist Framing 3% Inspect floor joist framing for proper spans, bearing, and connections. Verify that the preengineered floor framing is in accordance with the approved drawings and manufacturer s specifications. 0403 Concrete Slab Inspection 2% Verify that concrete slabs are placed in compliance with standards and material characteristics, and that proper precautions are used in adverse weather conditions. 0404 Subflooring and Decking 2% Verify that subflooring and decking has required thickness, span, and grade and meets installation specifications. Verify compliance of floor design and fasteners. 0405 Crawl Spaces 2% Verify that crawlspaces have required clearance, ventilation, insulation, screening, and access openings.

0406 Draftstops 2% Verify that draftstops are provided where required. 05 Wall Construction and Coverings 27% 0501 Lumber Quality - Walls 4% Verify that wood materials used in walls are in compliance with the markings, standards, and the material characteristics. Verify that cutting, notching, and borings are within the limitations permitted by code, and that wood members are protected against termites and decay where required. 0502 Wood Framing - Walls 4% Inspect wood wall framing for proper spacing, bearing, and connections. Verify that preengineered wall systems are in accordance with the approved drawings and manufacturer s specifications. 0503 Header Spans 2% Inspect header spans for proper span, bearing, and connections. 0504 Steel Framing 2% Verify that steel framing is in compliance with the markings, standards, and the material characteristics. 0505 Fireblocking 2% Verify that fireblocking is provided where required. 0506 Masonry Materials and Placement 2% Verify that masonry materials are in compliance with markings, standards, and the material characteristics. Inspect bonding, mortar type, mortar joint thickness, height, size, lintels, and distance between lateral supports for masonry walls. Verify that masonry is grouted where required. Verify that weather conditions are suitable for masonry construction and that proper precautions are used for adverse weather conditions. Inspect masonry reinforcement for size, length of lap splices, clearances between bars, clearances to masonry units and outside face of walls, alignment, cleanouts, and presence of loose rust, oil, or millscale. 0508 Concrete Wall Inspection 2% Verify that concrete walls are in compliance with standards and material characteristics, and that proper precautions are used for adverse weather conditions. Verify that prefabricated walls and wall forms are installed in accordance with manufacturer s instructions and approved plans. 0509 Braced Wall Panels 2% Verify that walls are braced to prevent lateral displacement and that loads are transferred to the foundation.

0510 Interior Coverings 2% Verify that wall and ceiling coverings are correct type and thickness and are correctly supported and fastened. Inspect walls, floor, and ceiling finishes in bathtub and shower spaces for compliance with the code. 0512 Exterior Sheathing, Veneers, and Weather-Resistant Coverings 3% Verify that exterior sheathing, veneers, and weather-resistant siding materials are correctly sized, identified, and installed; protected against termites and decay; and have appropriate clearances to finish grade. Verify that exterior veneers and weather-resistive siding have correct anchorage, support, and backing. Verify that a weather-resistant barrier is correctly installed for all walls and around all wall openings. 0513 Exterior Plaster, Stucco, and Lath 2% Verify that plaster, stucco, and metal lath have correct thickness and fasteners, and are correctly installed. 06 Roof/Ceiling Construction 14% 0601 Roof/Ceiling Insulation and Vapor Barriers 2% Verify that insulation is of permitted materials, is provided where required, and is correctly installed. Verify that vapor and moisture barriers are correctly installed. 0602 Attics/Ceiling 2% Verify that attic and ceiling area construction has proper ventilation, screens, and access. 0603 Roof Framing 4% Inspect roof rafters, collar beams, and ceiling joists for compliance with span, grade, type, connections, bearing, and quality requirements. Verify that trusses are in accordance with the drawings and properly spaced, braced, and supported. 0604 Roof Sheathing 2% Inspect roof sheathing for proper thickness, grade, support, and fastening. 0605 Roofs and Roof Coverings and Reroofing 2% Verify correct classification of roof coverings, roof slope, installation, flashings, and details, and method of roof drainage. Verify that residences that are reroofed comply with code, design, and installation standards. 0607 Fireplaces and Chimneys 2% Verify that fireplaces, flues, and chimneys are correctly designed and have required clearances from combustible construction. 07 Public Safety and Special Construction 17% 0701 Means of Egress 4% Inspect for compliance with the means of egress requirements for the building, including emergency egress for sleeping areas. Verify that doors and windows intended for use as emergency egress have correct clear opening areas, width, and heights.

0702 Exit Stairways and Ramps 3% Verify that stairways and ramps have correct width, rise, run, slope, landings, headroom, height, guardrails, and handrails. 0703 Exterior Construction 3% Verify that exterior stairs, ramps, porches, decks, and balconies which are open to the weather are constructed to support designed loads; are of suitable materials; and have required slope and width, tread, riser, headroom, guardrails, and handrail dimensions. 0704 Smoke Detectors 2% Inspect smoke detectors for compliance with proper installation, power supply, and locations. 0705 Flamespread of Insulation and Finishes 2% Verify that interior wall and ceiling finishes, insulation, and foam plastics comply with flame spread and smoke density requirements. 0706 Safety Glazing 3% Verify that safety glazing is installed and labeled where required.