GENERATING SET TECHNICAL GUIDE GSL22-42D Soundproof Sockets kit (5 sockets). 1 x 400V/63A 3P+N+T CE. 1 x 400V/16A 3P+N+T CE. PHS: COOLANT PREHEATING SYSTEM. CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED) CONTROL PANEL SUPPLEMENTS MAP: MANUAL ANALOGUE CONTROL PANEL. with analogue, and protected through door with Instrumentation (analogue) SKB: SOCKETS KIT B WITH 5 SOCKETS. RSS: REMOTE START/STOP. Only for MAP. Voltmeter with selector switch (3 phases). Frequency meter. Ammeter with selector switch (3 phases). Fuel level indicator. Oil pressure indicator. Engine temperature indicator. Start/stop selector switch with key. battery charger failure. Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure. Power cables connection directly from circuit breaker. 1 x 400V/63A 3P+N+T CE. 1 x 400V/16A 3P+N+T CE. LOAD TRANSFER SWITCH PANEL. IV poles - 45A. IV poles - 60A. Connections Terminals board for power cables connection (Genset-Mains-Load). Load transfer switch panel built in a metal cabinet and supplied loose from the genset. Protections Contactors mechanically and electrically interlocked. Note: Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. GSB: GALVANIZED BASEFRAME. Heavy duty galvanized skid to be installed under the genset. Easily transportable with fork lift and complete with leak proof tray. RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication available by means of RS232 directly to PC or through GSM modem). Available only on the automatic versions. STR: SITE TRAILER. Single axle. RTR: ROAD TRAILER (only for Spanish market). Single axle. HLT: HYDRAULIC LIGHTING TOWER COMPLETE WITH SITE TRAILER. It can be supplied with two different types of lights: Lights of quartz-iode halogen (6 x 1.500W) IP55. Lighting capacity: 200.000 lumen approx. Lights of metal halide (6 x 400W) IP55. Lighting capacity: 200.000 lumen approx. It is also equipped with 0,55kW electric motor, control panel (with circuit breaker protection) and hydraulic device to control the 9m extensible tower. Rev.00 Pag. 3 of 3
GENERATING SET TECHNICAL GUIDE GSL22-42D Soundproof Automatic control panel complete with digital control unit AC01 for monitoring, Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC01 for monitoring, through AC-01 Ouput through AC01 Mains/Genset Mains voltage. Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor forced - Manual starting - Genset contactor forced. Acoustic. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage, battery charger failure. Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Mains voltage. Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor forced - Manual starting - Genset contactor forced. Acoustic. IV poles - 45A. IV poles - 60A. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage, battery charger failure. Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED) AFP: AUTOMATIC FUEL TRANSFER PUMP. Not available with KRT. DCC: DIFFERENT CANOPY COLOUR. EEG: ENGINE ELECTRONIC GOVERNOR. (Woodward type) KRT: RENTAL KIT. Not allowed with PHS or AFP. Complete of: GENSET SUPPLEMENTS Battery switch. Fuel filter water separator. Three way valve. Leak proof tray. Earth rod. Sockets kit (3 sockets). Rev.00 Pag. 2 of 3
GENERATING SET TECHNICAL GUIDE GSL22-42D Soundproof REF. PCS 14.00 MODEL GSL30-42D DEUTZ Diesel engine. Oil cooling system with radiator. Internal residential muffler. Central lifting point. Complete with engine and battery liquids. Manual pump oil draining pipe. Baseframe capable to be moved with hand pallet truck. Rental kit as option (POWER ON RENT). Optional kit with hydraulic lighting tower completed site trailer. TECHINCAL FEATURES Acoustic power MODEL CODE PRIME POWER PRP EMERGENCY POWER LTP Voltage Frequency Power factor Fuel capacity Autonomy (100% load PRP) Acoustic pressure at 7m Dimensions (LxWxH) Weight DIESEL ENGINE Cooling system Speed Displacement Cyliders and disposition Aspiration Engine power PRP Fuel consumption (100% load) Specific consumption PRP Engine governor (standard) ALTERNATOR Insulation Mechanical degree protection kva (kw) kva (kw) Volt Hz Cos Litres LWA db(a) mm kg DEUTZ rpm c.c. n disp. kwm l/h g/kwh STAMFORD Class Voltage regulation (%) h SC290TDA 29,0 (23,2) 30,0 (24,0) Electrical system (DC) Volt 12 12 50 120 16,9 92 67 2.225 x 1.100 x 1.290 992 F4M 2011 Oil with radiator 1.500 3.110 4 L Natural 27,6 7,1 219 Mechanical BCI 184 F H IP23 Electronic (± 1,5) SC39TDA 39,3 (31,4) 41,2 (33,0) 50 120 12,8 92 67 2.225 x 1.100 x 1.290 1.064 BF4M 2011 Oil with radiator 1.500 3.110 4 L Turbo 36,4 9,4 217 Mechanical BCI 184 J H IP23 Electronic (± 1,5) (1) Depending on availability, MeccAlte alternator could be installed as variant, models ECO28 VL and ECO32 3S respectively (featuring IP21 and ±1% voltage regulation) complete with digital control unit BE23 for monitoring, This configuration is in modification process by other of similar features. through BE23 Generating set intensity (3 phases). DC supply selector switch. Push-buttons: start/stop. Genset protections: over-frequency, battery voltage out of limits. Genset protections: under/over voltage, over-load, under/over frequency, under/over battery voltage. Rev.00 Pag. 1 of 3
GENERATING SET TECHNICAL GUIDE GSW65-80D (SOUND) 50Hz CONTROL PANEL SUPPLEMENTS GENSET SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED) GENSET SUPPLEMENTS Sockets kit (5 sockets). SKB: SOCKETS KIT B WITH 5 SOCKETS. RSS: REMOTE START/STOP. Only for MAP. TIF: IV POLES CIRCUIT BREAKER INSTEAD OF III POLES. APM: PMG FOR STAMFORD ALTERNATOR + MX321 AVR. Only with Stamford configuration AFP: AUTOMATIC FUEL TRANSFER PUMP. DCC: DIFFERENT CANOPY COLOUR. EEG: ENGINE ELECTRONIC SPEED GOVERNOR. (EMR type) KRT: RENTAL KIT. Complete of: Battery switch. Fuel filter water separator. Three way valve. Earth rod. PHS: COOLANT PREHEATING SYSTEM. LOAD TRANSFER SWITCH PANEL. Load transfer switch panel built in a metal cabinet and supplied loose from the genset. RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication available by means of RS232 directly to PC or through GSM modem). Available only on the automatic versions. 1 x 400V/16A 3P+N+T CE. Contactors mechanically and electrically interlocked. Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. GSB: GALVANIZED SKIDS. Heavy duty galvanized skids to be installed under the genset. Easily transportable with fork lift. STR: SITE TRAILER. Single axle. Connections Protections 1 x 400V/63A 3P+N+T CE. 1 x 400V/63A 3P+N+T CE. 1 x 400V/16A 3P+N+T CE. IV poles - 90A. IV poles 110A. Terminals board for power cables connection (Genset-Mains-Load). RTR: ROAD TRAILER (homolgation only for Spanish territories). Single axle on -80D. Rev.00 Pag. 3 of 3
GENERATING SET TECHNICAL GUIDE GSW65-80D (SOUND) 50Hz Automatic control panel complete with digital control unit AC01 for monitoring, control and protection of the Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC01 for monitoring, control and protection of the CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED) CONTROL PANEL SUPPLEMENTS with analogue, and protected through door with lockable handle. through AC01 through AC01 Mains/Genset MAP: MANUAL ANALOGUE CONTROL PANEL. Instrumentation (analogue) Mains voltage. Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor forced - Manual starting - Genset contactor forced. Remote starting availability by means of the Acoustic. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage, battery charger failure. Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Circuit breaker protection: III poles. Mains voltage. Engine Temperature. Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor forced - Manual starting - Genset contactor forced. Acoustic. IV poles - 90A. IV poles 110A. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage, battery charger failure. Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). Voltmeter with selector switch (3 phases). Frequency meter. Ammeter with selector switch (3 phases). Fuel level indicator. Oil pressure indicator. Engine temperature indicator. Start/stop selector switch with key. battery charger failure. Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure. Circuit breaker protection: III poles. Rev.00 Pag. 2 of 3
GENERATING SET TECHNICAL GUIDE GSW65-80D (SOUND) 50Hz REF. GDS PCS.15 MODEL GSW65-80D TECHNICAL FEATURES DEUTZ Diesel engine. Water cooling system. Internal residential muffler. Detachable central lifting eye. Baseframe capable to be moved with hand pallet truck. Complete with engine and battery liquids. Manual pump oil draining pipe. Fully bunded / Completly sealed baseframe. Rental kit as option (POWER ON RENT). MODEL CODE PRIME POWER PRP EMERGENCY POWER LTP Voltage Frequency Power factor Fuel capacity Autonomy (100% load PRP) Speed kva (kw) kva (kw) Volt Cos Litres rpm SC560TDA 57,7 (46,1) 63,0 (50,4) Acustic power LWA 96 Acustic pressure at 7m Dimensions (LxWxH) Dry weight DIESEL ENGINE Fuel consumption (100% load) Hz h db(a) mm l/h Electronic (± 1,5) SC740TDA 74,1 (59,3) 78,5 (62,8) Electronic (± 1,5) (1) Depending on availability, MeccAlte alternator could be installed as variant, models ECO32 2L and ECO32 3L respectively (featuring IP21 and ±1% voltage regulation) 50 340 24,8 71 BF4M 2012-G2 Cooling system Water Displacement Cyliders and disposition Aspiration Engine power PRP Specific consumption PRP Engine governor (standard) Electrical system (DC) ALTERNATOR (1) Insulation Mechanical degree of protection kg DEUTZ c.c. n disp. kwm g/kwh Volt STAMFORD Class Voltage regulation (%) 2.710 x 1.180 x 1.535 1.300 1500 4.040 4 L Turbo 52,0 13,7 221 Mechanical 50 2.710 x 1.180 x 1.535 1.460 66,1 15,7 199 Mechanical 12 12 UCI 224 E H IP23 340 21,7 96 71 BF4M 2012 C Water 1500 4.040 4 L Turbo - Intercooler UCI 224 F H IP23 complete with digital control unit BE23 for monitoring, control and protection of the through BE23 Power ( kva - kw - kvar). DC supply selector switch. Push-buttons: start/stop. Remote starting availability by means of the Genset protections: over-frequency, battery voltage out of limits. Genset protections: under/over voltage, over-load, under/over frequency, under/over battery voltage. Circuit breaker protection: III poles. This configuration is in modification process by other of similar features. Rev.00 Pag. 1 of 3
GENERATING SET TECHNICAL GUIDE GSW15-22P Soundproof CONTROL PANEL SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED) MAP: MANUAL ANALOGUE CONTROL PANEL. CONTROL PANEL SUPPLEMENTS with analogue, and protected through door with lockable handle. Instrumentation (analogue) Voltmeter with selector switch (3 phases). Frequency meter. Ammeter with selector switch (3 phases). Fuel level indicator. Oil pressure indicator. Engine temperature indicator. Start/stop selector switch with key. battery charger failure. Engine protection unit: low fuel level, low pressure oil, high engine temperature, battery charger failure. Power cables connected to terminals board (external). RSS: REMOTE START/STOP. Only for MAP. LOAD TRANSFER SWITCH PANEL. GSW15D GSW22D Connections IV poles - 20A. IV poles - 32A. Terminals board for power cables connection (Genset-Mains-Load). Load transfer switch panel built in a metal cabinet and supplied loose from the genset. Protections Contactors mechanically and electrically interlocked. Note: Automatic control panel + LTS panel measures the Mains voltage and starts automatically the genset within few seconds in case of Mains failure. It transfers immediately the load again to the genset when the Mains voltage returns within the rated values. GSB: GALVANIZED BASEFRAME. Heavy duty galvanized skid to be installed under the genset. Easily transportable with fork lift and complete with leak proof tray. RCG: REMOTE CONTROL BY GSM KIT (kit for genset management and control by remote PC; comunication available by means of RS232 directly to PC or through GSM modem). Available only on the automatic versions. STR: SITE TRAILER. Single axle. Rev.00 Pag. 3 di 3
GENERATING SET TECHNICAL GUIDE GSW15-22P Soundproof Automatic control panel complete with digital control unit AC01 for monitoring, through AC-01 Ouput GSW15D Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor forced - Manual starting - Genset contactor forced. Acoustic. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage, battery charger failure. Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. GSW22D Automatic control panel for automatic starting by Mains failure. Delivered loose from the genset, and complete with digital control unit AC01 for monitoring, Mains/Genset through AC01 control unit. GSW15PD GSW22D Selector switch with six positions: Automatic test - Automatic starting - Engine locked - Mains contactor forced - Manual starting - Genset contactor forced. Acoustic. IV poles - 20A. IV poles - 32A. Genset protections: under/over voltage, overload, under/over frequency, starting failure, under/over battery voltage, battery charger failure. Genset protection: under/over voltage, overload, under/over battery voltage, battery charger failure. Plinth row for connection from pre-wired panel (mounted on the genset) to AMF panel. Power cables connected to terminals board (internal). GENSET SUPPLEMENTS (ONLY AVAILABLE WHEN ORDERED) AFP: AUTOMATIC FUEL TRANSFER PUMP. Not available with KRT. DCC: DIFFERENT CANOPY COLOUR. MACHINE SUPPLEMENTS KRT: RENTAL KIT. Not allowed with PHS or AFP. Complete of: Battery switch. Fuel filter water separator. Three way valve. Leak proof tray. Earth rod. Sockets kit. PHS: COOLANT PREHEATING SYSTEM. Rev.00 Pag. 2 di 3
GENERATING SET TECHNICAL GUIDE GSW15-22P Soundproof MODEL GSW15-22 Deutz DEUTZ Diesel engine. Water cooling system. Internal residential muffler. Central lifting point. Baseframe capable to be moved with hand pallet truck. Complete with engine and battery liquids. Manual pump oil drain pipe. Rental kit as option (POWER ON RENT). REF. GDS 18.0D TECHNICAL FEATURES MODEL GSW15D GSW22D CODE SC130TDA SC200TDA PRIME POWER PRP kva (kw) 14,3 (11,4) 20,1 (16,1) EMERGENCY POWER LTP kva (kw) 15,0 (12,0) 21,1 (16,8) Voltage Volt Frequency Hz 50 50 Power factor Cos Tank capacity Litres 55 55 Autonomy (100% load PRP) h 14,5 10,6 Acustic power LWA TBA TBA Acustic pressure at 7m db(a) # VALOR! # VALOR! Dimensions (LxWxH) mm 1.800 x 830 x 1.295 1.800 x 830 x 1.295 Weight kg 700 775 DIESEL ENGINE DEUTZ D2009L03 D2009L04 Cooling system Water Water Speed r.p.m. 1.500 1.500 Displacement c.c. 1.718 2.290 Cyliders and disposition n disp. 3 L 4 L Aspiration Natural Natural Engine power PRP kwm 14,8 19,1 Fuel consumption (100% load) l/h 3,8 5,2 Specific consumption PRP g/kwh 240 229 Engine governor (standard) Mechanical Mechanical ALTERNATOR Brand - Mecc Alte - ECO 3 2L/4 Stamford - BCI 184 E Insulation Class H H Mechanical degree of protection IP23 IP23 Voltage regulation Electronic Electronic TECHNICAL CHARACTERISTICS NOT IMPEGNATIVE RESERVATION OF MODIFICATIONS FOR INNOVATION OF THE PRODUCT complete with digital control unit for monitoring, control and protection of the through digital GSW15D Generating set intensity (3 phases). DC supply selector switch. Push-buttons: start/stop. Genset protections: under/over voltage, over-load, under/over frequency, under/over battery voltage. GSW22D Genset protections: over-frequency, battery voltage out of limits. Rev.00 Pag. 1 di 3