CONVENTIONAL LIQUID METER PROVERS DESIGN AND CONSTRUCTION

Similar documents
LIQUID FLOW PROVERS (Conventional) Class Number 252. Brendan S. Ryan Smith Meter Inc P.O. Box 4658 Corpus Christi, Texas 78404

PRESSURE REDUCING CONTROL VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

191: Calibration and Standards in Flow Measurement. Richard Paton National Engineering Laboratory, Scotland, UK 1 GENERAL PRINCIPLES

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

PIPING SYSTEM - ABRASIVE SLURRIES Engineering Standard Specification. 96 B. Riutta

V47 Series Temperature Actuated Modulating Water Valves

OPERATING and MAINTENANCE MANUAL SERIES 2700A CONTROL VALVE CONTENTS. INTRODUCTION...1 Scope...1 Description...1 Valve Identification...

valve solutions Chemical Cosmetic Cryogenic Food & Beverage Marine Mining Nuclear Oil & Gas Paint Pharmaceutical Pulp & Paper

ASME Packaged Indirect Fired Water Heater

James M. Pleasants Company

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

RMF Engineering

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

Oil and Gas Pipeline Design, Maintenance and Repair

COUNTERBALANCE VALVES

These features have made Lo Torc valves the choice of high pressure plug value users, worldwide:

NCCER Progress Blvd., Alachua, FL Tel: (888) Task Number Item Date(s) Recorded By

RUBBER SLEEVE KNIFE GATE VALVE

DARTMOUTH COLLEGE DESIGN January 3, 2012 & CONSTRUCTION GUIDELINES

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

GS-General Service Control Valves

Installation, Operating and Maintenance Instructions for AEON Metal Seated Gate Valve (MSGV) Water

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

BALL VALVES SIDE ENTRY TOP ENTRY

Pressure Vessel Assessment Report

The Unique Accelabar Flow Meter

Round Housing with Side Ports

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Flanged and Butt-= Weld Type

Automatic Self-Cleaning Strainers

BERMAD Waterworks. Pressure Relief/Sustaining Valve. 700 Series. Model 730. Features and Benefits. Major Additional Features

INSTALLATION, OPERATION & MAINTENANCE MANUAL

PBM has solutions for your valve application.

WILROY. Operation. Optional Diaphragm Rupture Detection HYDRAULICALLY ACTUATED DIAPHRAGM PUMP

Inspections Standard Operating Procedure 5 Aboveground Storage Tanks

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

FOAM CHAMBER MODEL - FC

Unit 24: Applications of Pneumatics and Hydraulics

FLANGED END BALL VALVE

Unit 24: Applications of Pneumatics and Hydraulics

Morrison Bros. Co. General Product Specifications

81000 Series Aluminum Gate Valve Installation and Repair Manual

A global supplier of quality instrumentation/piping specification valves through product design and reliability for total customer satisfaction

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

Installation, Operation and Maintenance Manual for Pilot Operated Valves

BB-18 Black Body High Vacuum System Technical Description

The First Choice in Secondary Valves. GREENWOOD VALVES

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

Vogt Valves The Connection Bulletin for Extended Body Forged Steel Valves Welded Bonnet, Bolted Bonnet, Class 800 & Class 1500 CB 22

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

HOPPER SHAPE KNIFE GATE VALVE

SECTION DUCTILE IRON PIPE AND FITTINGS

Equivalents & Conversion Factors 406 Capacity Formulas for Steam Loads 407 Formulas for Control Valve Sizing

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

Engineered Solutions

Stilling Well Recommendations

Daniel Orifice Fittings Brochure. Senior Orifice Fitting, Simplex Orifice Plate Holder, Junior Orifice Fitting, Orifice Flange Union, Meter Tubes

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Used Fluid Handling Portable Used-Oil Gravity Drains

Gas Custody Transfer Calibration

BLADDER SURGE CONTROL SYSTEM

G. VULCANIZED SEAT Pressure sensitive seating with full disc overlap provides positive seating at high and low pressures.

SECTION PIPE HANGERS AND SUPPORTS

Light Duty Commercial Electric Water Heater

MUELLER FALLING FILM CHILLERS

NFPA31FuelOilPiping 1 Revised

PSAC/SAIT Well Testing Training Program Learning Outcomes/Objectives Level B

System Saver 318 Air Compressor for Mack E-Tech and ASET Engines

In-Line Air Separators

TECHNICAL DATA. Dry 122a. November 12, 2013


BETTIS CONVERSION INSTRUCTIONS TO CONVERT HD SERIES ACTUATORS TO HD-M3, HD-SR-M3 HD-M3HW OR HD-SR-M3HW SERIES PNEUMATIC ACTUATORS

61W - Wafer style resilient seated butterfly valve 61L - Lugged style resilient seated butterfly valve

Mechanical Installation

API Std 53 - Blowout Prevention Equipment Systems for Drilling Wells Last update: August 12, 2015

CHROME FRONT BRAKE MASTER CYLINDER KIT

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Check Valves & Actuated Valves

High Pressure Equipment Pressure Vessels and Reactors Index

LEAKAGE ACCEPTANCE RATES COMPARISON METAL & SOFT SEATED VALVES API 598/API 6D/MSS SP-61/FCI 70-2

Baumann Flexsleev Sanitary Control Valve

Fire Pump Plan Review March 2010

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

08.08 Vic-Check Valves

Scraper Passage Indicator. Electrical Indicator. Features

Plant components, selected for sound performance

The Augustus Group Products Projects and Engineering Consulting. ASME BOILER AND PRESSURE VESSEL CODE Mike Looram

Fundamental Principles of Rotary Displacement Meters

Fire Hydrant Troubleshooting

INDIAN STANDARDS FOR NATURAL GAS PIPELINE SYSTEM

Econosto UK. LEICESTER Econosto UK Ltd Cambridge Road Whetstone Leicester LE8 6ZG T: +44 (0) F: +44 (0)

Zenith Solar thermal 4.5m pump station Installation manual

SPECIFICATION DIVISION 22 SECTION DESCRIPTION DIVISION 22 PLUMBING SECTION THERMOMETERS, PRESSURE GAUGES, AND ACCESSORIES

SECTION DUCTILE IRON PIPE AND FITTINGS

Transcription:

CONVENTIONAL LIQUID METER PROVERS DESIGN AND CONSTRUCTION I. Meter Prover Definition Liquid Flow Provers are defined as a Known Traceable Volume which is used to verify and establish a meter factor during actual flowing and operating conditions. (Traceable to NIST) II. Types of Conventional Meter Provers A) Bidirectional Prover (pipe prover): A positive displacement type prover with flow and displacer traveling in both directions by means of a 4-way diverter valve. B) Unidirectional Prover (pipe prover): A positive displacement type prover with flow and displacer traveling always in one direction, by means of a transfer chamber, or interchange. C) Volumetric Tank Prover: As the name implies, this prover is a calibrated tank or vessel with a sight gauge and scale to read a metered volume. The flow must be stopped to determine the volume. III. Principle of Operation of a Positive Displacement Meter Prover We will use bidirectional provers as the example for most items. (Please see the drawing attached) A) To prove a meter, flow is established though the meter then to the prover via the prover manifold valves. B) Flow goes into the 4-way diverter valve and forces a sphere displacer into the pipe section, which seals against the pipe walls. C) The displacer passes between two detector switches. The volume between switches is known as the calibrated volume. This volume is compared to the volume indicated by the meter, to determine a meter factor. Meter Factor = Actual Volume (Prover) Metered Volume (Meter) IV. Design of Meter Provers A) Parameters Required for Prover Design 1) Service a) Products b) Pressure and temperature c) Gravity d) Viscosity e) Maximum & Minimum Flow Rate

2) Meter(s) to be proved a) Minimum pulses per unit volume, or K factor (e.g., 1000 pulses per BBL). 3) Design Specifications and Codes a) ASME/ANSI B31.4 Pipeline (mechanical design) b) ASME/ANSI B31.3 Refinery (mechanical design) c) Material Specifications d) Electrical Classification e) ANSI Pressure Rating f) Space Limitations g) Automation h) Prover configuration, (e.g., aboveground, portable, etc.) API Chapter 4 Proving Systems, Section 2 Conventional Pipe Provers, is the industry standard for prover design, calibration, and recommended practices. B) Sizing and Volume Requirements 1) Prover sizing is determined by Maximum and Minimum Sphere Velocities Maximum: Minimum: Unidirectional - 10 ft/sec. Bidirectional - 5 ft/sec. depends on lubricating properties of the product --low velocities may cause sphere to jerk or surge 2) Prover volume is determined by: a) API specifies the accumulation of 10,000 unaltered meter pulses between detector switches. b) Meter K Factor (or pulses per unit volume). c) Repeatability of the detector switches and system. d) Prover counter resolution A prover must be capable of repeating the volume between detector switches by 0.02 percent. (By Water-Draw Calibration) Prover sizing and Volume must be considered with other factors to have a Realistic Prover Design, e.g.: Space Available Costs Meter Selection and Pulses Transmitted Product service Etc.

C) Pre-Run Length A prover must have a sufficient pre-run length from the launch chamber to the first detector switch to allow the 4-way diverter valve to cycle completely and seal properly before the displacer triggers the first detector switch. Also allowing the displacer to reach uniform velocity. V. Prover Construction and Components A) Pipe: Pipe should be free of defects, dents, scratches or rust pits. Pipe should be hand-picked for uniformity and roundness. B) Flange Seats: Flanges in the calibrated section are match-bored, machined with O-Ring grooves for sealing, and dowel-pinned. C) Launch Chambers: The pipe section prior to the pre-run and calibrated section is used to launch and receive the sphere. Launch chambers are normally two pipe sizes larger to allow flow by-pass around the sphere and allow the sphere to decelerate. Also allowing easy sphere removal with the use of quick opening closures. Launch chambers can be horizontal, vertical, or inclined. D) Sphere and Accessories: Inflatable sphere displacers are the most common used. The sphere is normally inflated from 2% to 4% larger than the prover pipe inside diameter. The sphere is filled with 50/50 mix of glycol and water. Proper inflation and roundness are vital for sealing and repeatability. Sphere Materials Available: 1) Neoprene 2) Nitile 3) Urethane (most commonly used and can be purchased in various durometers) Sphere Removal Tools Pumps & Inflating Kits Sizing Rings E) Detector Switches: Detector Switches are used to gate the pulse counter. Detector switch repeatability is crucial in determining the prover volume and in turn proving a meter. The most common switch is a Mechanical Actuated Electrical type, such as our Mag-Tek M-5, which has a plunger inserted into the pipe. The sphere passes under the plunger to raise and make the switch or contact. These switches are all pressure balanced so pressure forces are not a factor.

F) Diverter Valve: Bidirectional provers utilize a 4-way diverter valve. This valve is ported to allow flow to enter one launch chamber and exit the opposite, and by cycling the valve the flow direction is reversed. All 4-way valves are designed for speed and seat seal integrity. Valves should be equipped with a means of checking the seal for leakage (e.g., Block and Bleed Port, DP Gauge or Switch). G) Diverter Valve Operator: Most diverter valves are equipped with actuators to automate the prover operation. These can be electrical, hydraulic, or pneumatic. Electric operators are the most commonly used. Manual handwheels, with latching mechanisms, are used on smaller systems. H) Internal Coatings: Internal coatings are applied to the prover for two main purposes: 1) Protect the pipe from corrosion and pitting which can cause repeatability problems. 2) Provide a smooth uniform surface for the sphere to travel in, and ensure a good seal with stable movement without surges or jerks. Common Types of Coating: 1) Air-Dried Epoxy 2) Baked-On Phenolic 3) None Bare (crude service) VI. Prover Accessories and Trim: 1) External Paint and Insulation 2) Drain Valves, Block & Bleed Type 3) Pressure Gauges 4) Thermometers 5) Pressure Relief Valve 6) Pressure and Temperature Transmitters 7) Field Calibration Connections 8) Sphere by-pass for Vertical Launch Chambers 9) Skid Mounted 10) Vent Valves We always specify and use good quality Accessories and Trim equipment.

VII. Calibration Prior to placing a prover into service, a Base Prover Volume must be determined. This is done by a water-draw calibration as outlined in API Chapter 4, as previously mentioned, and API Chapter 12, Section 2, Part 4. The calibration also verifies that all components are sealing properly and are in working condition. The calibration is completed using field measures, thermometers, and gauges that are traceable to NIST. VIII. Summary Conventional pipe provers are the most commonly used and accepted method of meter proving. Care of details in design specifications, construction, and calibration are essential to the proper functioning of a complete measurement system. IX. Please use our Prover Data Sheet for your Inquiry or Purchase Order. This will allow us to propose a more detailed offering for your application.

TYPICAL METER PROVER SPECIFICATIONS AND OPTIONS Design and Construction: API Manual of Petroleum Measurement Standards, Chapter 4 Proving Systems, ASME/ANSI B31.4, ASME/ANSI B31.3, or ASME Section VIII. Radiography: Spot or 100% in accordance with API 1104. Hydrotest: 1.5 times design pressure with chart recording. Inspection Flanges: Match bored, dowel pinned and O-ring groove for metal to metal seat. Materials: Pipe - ASTM A-106/53-Gr B Seamless Flanges and threaded fittings - ASTM A-105 Weld fittings - ASTM A-234 WPB Studs - ASTM A-193-B7 Nuts - ASTM A-194-2H Gaskets - Spiralwound, 304SS O-Rings - Viton Calibration: Water draw method, repeatability within 0.02 percent per API Chapter 4, Chapter 11.2.3 and Chapter 12, Section 2. Internal Coating: Sandblast to white metal and 5 to 7 mils Flexkote 707 air dried epoxy or Phenoxy 109 baked on phenolic. External Coating: Sandblast to white metal and one coat zinc chromate primer. Standard Equipment and Trim: Four way diverter valve with viton seals and differential pressure gauge Detector switches - Mag-Tek M-5, SS construction with viton seals Valve actuator - Electric Class I Group D Div II or manual handwheel Sphere - Inflatable polyurethane, nitrile, or neoprene with accessories (pump and sizing ring) Quick opening closure, hinged or davit type Thermometers - mercury in glass with 0.20ºF divisions and SS thermowells Pressure gauges with isolation valves Pressure relief valve Vent valves Drain valves Semi-skid beam supports Other materials and options available.