Use of Steel Fiber Reinforced Concrete for Enhanced Performance of Deep Beams with Large Openings

Similar documents
Draft Table of Contents. Building Code Requirements for Structural Concrete and Commentary ACI

Assistant Professor of Civil Engineering, University of Texas at Arlington

ANALYSIS FOR BEHAVIOR AND ULTIMATE STRENGTH OF CONCRETE CORBELS WITH HYBRID REINFORCEMENT

USE OF CFRP LAMINATES FOR STRENGTHENING OF REINFORCED CONCRETE CORBELS

Hardened Concrete. Lecture No. 14

LARGE SCALE TENSILE TESTS OF HIGH PERFORMANCE FIBER REINFORCED CEMENT COMPOSITES

IMPROVING THE STRUT AND TIE METHOD BY INCLUDING THE CONCRETE SOFTENING EFFECT

DESIGN OF SLABS. 3) Based on support or boundary condition: Simply supported, Cantilever slab,

SECTION 3 DESIGN OF POST TENSIONED COMPONENTS FOR FLEXURE

1.054/1.541 Mechanics and Design of Concrete Structures (3-0-9) Outline 1 Introduction / Design Criteria for Reinforced Concrete Structures

Numerical modelling of shear connection between concrete slab and sheeting deck

SECTION 3 DESIGN OF POST- TENSIONED COMPONENTS FOR FLEXURE

Objectives. Experimentally determine the yield strength, tensile strength, and modules of elasticity and ductility of given materials.

SP FRC PERFORMANCE COMPARISON: UNIAXIAL DIRECT TENSILE TEST, THIRD-POINT BENDING TEST, AND ROUND PANEL TEST

PCI BIG BEAM COMPETITION

SEISMIC DESIGN. Various building codes consider the following categories for the analysis and design for earthquake loading:

Behavior of High-Strength Concrete Rectangular Columns

Detailing of Reinforcment in Concrete Structures

Structural Integrity Analysis

BEHAVIOR OF SHORT CONCRETE COLUMNS REINFORCED BY CFRP BARS AND SUBJECTED TO ECCENTRIC LOAD

FOOTING DESIGN EXAMPLE

INTRODUCTION TO BEAMS

ABSTRACT 1. INTRODUCTION 2. DESCRIPTION OF THE SEGMENTAL BEAM

APE T CFRP Aslan 500

Chapter 5 Bridge Deck Slabs. Bridge Engineering 1

Optimum proportions for the design of suspension bridge

Performance of Existing Reinforced Concrete Columns under Bidirectional Shear & Axial Loading

METHOD OF STATEMENT FOR STATIC LOADING TEST

Fire and Concrete Structures

PRESTRESSED CONCRETE. Introduction REINFORCED CONCRETE CHAPTER SPRING Reinforced Concrete Design. Fifth Edition. By Dr. Ibrahim.

SEISMIC RETROFITTING TECHNIQUE USING CARBON FIBERS FOR REINFORCED CONCRETE BUILDINGS

DESIGN OF SLABS. Department of Structures and Materials Engineering Faculty of Civil and Environmental Engineering University Tun Hussein Onn Malaysia

Technical Notes 3B - Brick Masonry Section Properties May 1993

bi directional loading). Prototype ten story

THE EFFECT OF STIRRUPS AND HOOKED STEEL FIBERS INSTEAD ON MOMENT-ROTATION CAPACITY OF BEAM-COLUMN CONNECTIONS

Numerical Analysis of Independent Wire Strand Core (IWSC) Wire Rope

1.5 Concrete (Part I)

SLAB DESIGN. Introduction ACI318 Code provides two design procedures for slab systems:

Nur Yazdani, Ph.D., P.E. Professor. Lisa Spainhour, Ph.D. Associate Professor. Saif Haroon Research Assistant. FDOT Contract No. BC-386.

Design of reinforced concrete columns. Type of columns. Failure of reinforced concrete columns. Short column. Long column

SEISMIC UPGRADE OF OAK STREET BRIDGE WITH GFRP

PERFORMANCE OF SLABS REINFORCED BY PEIKKO PSB STUDS

Validation of Cable Bolt Support Design in Weak Rock Using SMART Instruments and Phase 2

NONLINEAR FINITE ELEMENT ANALYSIS FOR REINFORCED CONCRETE SLABS UNDER PUNCHING LOADS

Lab 1 Concrete Proportioning, Mixing, and Testing

Concrete Design Manual

Methods for Seismic Retrofitting of Structures

MATERIALS AND MECHANICS OF BENDING

Design of Fibre Reinforced Concrete Beams and Slabs

Detailing of Reinforcement in Concrete Structures

Pavement Thickness. esign and RCC-Pave Software. Roller-Compacted Concrete Pavement: Design and Construction. October 24, 2006 Atlanta, Georgia

1.2 Advantages and Types of Prestressing

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES OUTCOME 2 ENGINEERING COMPONENTS TUTORIAL 1 STRUCTURAL MEMBERS

Reinforced Concrete Design

Introduction to Solid Modeling Using SolidWorks 2012 SolidWorks Simulation Tutorial Page 1

Stress Strain Relationships

DESIGN AND ANALYSIS OF BRIDGE WITH TWO ENDS FIXED ON VERTICAL WALL USING FINITE ELEMENT ANALYSIS

ADVANTAGES OF STEEL FIBRE REINFORCED CONCRETE IN INDUSTRIAL FLOORS

In-situ Load Testing to Evaluate New Repair Techniques

Overview of Topics. Stress-Strain Behavior in Concrete. Elastic Behavior. Non-Linear Inelastic Behavior. Stress Distribution.

DEVELOPMENT OF A NEW TEST FOR DETERMINATION OF TENSILE STRENGTH OF CONCRETE BLOCKS

THEORETICAL BEHAVIOR OF COMPOSITE CONSTRUCTION PRECAST REACTIVE POWDER RC GIRDER AND ORDINARY RC DECK SLAB

EDEXCEL NATIONAL CERTIFICATE/DIPLOMA MECHANICAL PRINCIPLES AND APPLICATIONS NQF LEVEL 3 OUTCOME 1 - LOADING SYSTEMS TUTORIAL 3 LOADED COMPONENTS

Deflection Calculation of RC Beams: Finite Element Software Versus Design Code Methods

The following sketches show the plans of the two cases of one-way slabs. The spanning direction in each case is shown by the double headed arrow.

INFLUENCE OF STEEL FIBERS AS ADMIX IN NORMAL CONCRETE MIX

16. Beam-and-Slab Design

TECHNICAL SPECIFICATION SERIES 8000 PRECAST CONCRETE

A transverse strip of the deck is assumed to support the truck axle loads. Shear and fatigue of the reinforcement need not be investigated.

The Impact of Market Demands on Residential Post-Tensioned Foundation Design: An Ethical Dilemma

Uniaxial Compressive Strength of Cold-formed Steel Tubular Sections with Recycled Aggregate Concrete Infill

Objective To conduct Charpy V-notch impact test and determine the ductile-brittle transition temperature of steels.

TECHNICAL NOTE. Design of Diagonal Strap Bracing Lateral Force Resisting Systems for the 2006 IBC. On Cold-Formed Steel Construction INTRODUCTION

FOUNDATION DESIGN. Instructional Materials Complementing FEMA 451, Design Examples

NOTCHES AND THEIR EFFECTS. Ali Fatemi - University of Toledo All Rights Reserved Chapter 7 Notches and Their Effects 1

Research on the meaning of reinforcement ductility for a behavior of double-spans reinforced concrete beam.

Modern Codes for Design of Concrete Concrete Structures Presentation Outline

FATIGUE CONSIDERATION IN DESIGN

Page 1 of Sven Alexander Last revised SB-Produksjon STATICAL CALCULATIONS FOR BCC 250

Welded Fabric. The CARES Guide to Reinforcing Steels Part 5. Installation of welded fabric on a major contract. 1.0 Introduction

C E L CONSULTING A D I V I S I O N O F C O N S O L I D A T E D E N G I N E E R I N G FOR THE

Requirements for the Use of PRESSS Moment-Resisting Frame Systems

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

Seismic design of beam-column joints in RC moment resisting frames Review of codes

The Strength of Concrete

Analysis of M35 and M40 grades of concrete by ACI and USBR methods of mix design on replacing fine aggregates with stone dust

Bending, Forming and Flexing Printed Circuits

Experimental assessment of concrete damage due to exposure to high temperature and efficacy of the repair system

Effect of Reinforcing Bar Contamination on Steel-Concrete Bond During Concrete Construction

SEISMIC DESIGN PROVISIONS FOR PRECAST CONCRETE STRUCTURES. S.K. Ghosh, Ph. D. President S.K. Ghosh Associates Inc. Northbrook, IL BACKGROUND

Design of Steel Structures Prof. S.R.Satish Kumar and Prof. A.R.Santha Kumar. Fig some of the trusses that are used in steel bridges

Reliability of Temperature-Dependent Models for Analysis of Reinforced Concrete Members Subjected to Fire

Chapter 8. Flexural Analysis of T-Beams

CH 6: Fatigue Failure Resulting from Variable Loading

Force measurement. Forces VECTORIAL ISSUES ACTION ET RÉACTION ISOSTATISM

Use of Strain Gauge Rosette to Investigate Stress concentration in Isotropic and Orthotropic Plate with Circular Hole

Fatigue Performance Evaluation of Forged Steel versus Ductile Cast Iron Crankshaft: A Comparative Study (EXECUTIVE SUMMARY)

SECTION 5 ANALYSIS OF CONTINUOUS SPANS DEVELOPED BY THE PTI EDC-130 EDUCATION COMMITTEE LEAD AUTHOR: BRYAN ALLRED

AN EXPERIMENTAL STUDY ON STRENGTH AND FRACTURE PROPERTIES OF SELF HEALING CONCRETE

Transcription:

1981 Use of Steel Fiber Reinforced Concrete for Enhanced Performance of Deep Beams with Large Openings D. R. Sahoo 1 and S.-H. Chao 2 1 Postdoctoral Fellow, Department of Civil Engineering, University of Texas at Arlington, TX 76019; PH (817) 272-9163; email: drsahoo@uta.edu 2 Assistant Professor, Department of Civil Engineering, University of Texas at Arlington, TX 76019; PH (817) 272-2550; FAX (817) 272-2630; email: shchao@uta.edu ABSTRACT Reinforced concrete deep beams are used as primary load distribution elements in various civil engineering structures. Large openings often interrupt the load transfer by concrete struts in these beams and cause a sharp decrease in strength and serviceability. Although the strength evaluation and reinforcement details around the openings are essential considerations, the ACI Building Code does not provide explicit guidance for designing these elements with openings. Strut-and-tie models are commonly used for strength evaluation and design of deep beams with openings. However, reinforcement detailing based on these models can be very complex and the failure of deep beams may be due to localized damages that could not be predicted by the strut-and-tie models. In this study, an experimental investigation was conducted on two concrete deep beam specimens with large single opening, namely, reinforced concrete (RC) and steel fiber reinforced concrete (SFRC), to evaluate their performance under monotonically increased load. The reinforcement detailing in the SFRC specimen was considerably reduced since the steel reinforcement bars were only used for the tensile longitudinal reinforcements and the boundary elements. Both test specimens had significantly higher strength than the designed load computed based on one assumed strut-and-tie model. INTRODUCTION Deep beam can be defined as a beam in which either clear span is equal to or less than four times the overall member depth or concentrated loads are within a distance equal to or less than two times the depth from the face of support (ACI Committee 318, 2008). Very often, openings are located through these deep beams to provide access for conduits or mechanical chases. These openings disrupt the stress flow from the loading zones to the supports. Code-specified empirical formulas used to design these members do not explicitly address the design of D-regions with

1982 openings. Instead, various strut-and-tie models have been used for designing these discontinuous regions. Past studies (e.g. Maxwell and Breen, 2000; Chen et al., 2002; Kuchma and Park, 2007; Tan and Zhang, 2007; Breña and Morrison, 2007) showed that the strutand-tie models provide consistent and conservative results in terms of ultimate strength of deep beams with openings. Further, large differences can exist between the calculated forces from strut-and-tie model and actual instrumented experimental specimens. A poorly selected and detailed strut-and-tie model can lead to severe cracking and damages under service loads (Kuchma et al., 2008). From the construction point of view, the primary difficulty associated in the design based on strut-and-tie models is the problem of anchorage and congestion due to large amount of reinforcement bars in the member. Steel Fiber Reinforced Concrete (SFRC) has gained increased popularity in construction industries in the recent years. Reinforcing plain concrete with steel fibers has been used to reduce conventional steel reinforcement in structural members such as slabs (ACI Committee 544, 1996). SFRC members can exhibit enhanced shear strength, more ductile behavior and reduced crack widths (Dupont et al., 2003). In addition, SFRC offers a multidirectional reinforcement, simple detailing without congestion, and higher post-cracking residual stress and ductility. Past studies (Narayanan and Darwish, 1986; Mansur and Ong, 1991) have shown that including discrete fibers in concrete enhance the strength and the deformation capacities of deep beams in addition to better cracking control. This paper presents the behavior of a RC deep beam with single opening under the action of monotonically increased loading. The deep beam was designed using a strut-and-tie model and the observed ultimate strength and failure modes were compared with those predicted by the model. Further, a geometrically similar SFRC deep beam was tested under the same loading conditions to compare its behavior, in terms of ultimate strength and failure modes, with that of the RC deep beam. SFRC deep beam consisted of conventional longitudinal steel bars as flexural tensile reinforcement only at the bottom face. The effectiveness of reinforcement detailing at the critical locations and the importance of steel fibers in concrete are recognized in this study to enhance the performance of concrete deep beams with openings. TEST SPECIMENS The specimens tested in this experimental study had the same but 1/4 scale geometry as the analytical model originally considered by Schlaich et al. (1987). Earlier, the specimen with the same geometry and dimensions were also tested by other researchers (Breña and Morrison, 2007). The overall dimension of the specimens was 74 in. (1875 mm) long, 46 in. (1170 mm) deep, and 4.5 in. (112 mm) thick. The specimens had a 15 in. (380 mm) square opening near the left-bottom corner of the beams as shown in Figure 1(a). The position and size of the openings in the specimens were selected to interfere with the direct load paths that could

1983 potentially form between the loading point and the supports (Breña and Morrison, 2007). Two types of test specimens (i.e., RC and SFRC) were investigated in the present study. The RC specimen consisted of reinforcement bars designed and detailed as per a strut-and-tie model as discussed later, whereas the SFRC specimen consisted of reinforcement bars for longitudinal tensile reinforcements only at its bottom. Because of complete absence of complex detailing of reinforcement bars, the construction of the SFRC specimen was simple and fast. (a) (b) Figure 1. (a) Details of test specimen and location of LVDTs (b) Strut-and-tie model used in the present study There is no unique strut-and-tie model to design a particular discontinuous structure. Strut-and-tie model, originally proposed by Schlaich et al. (1987), approximately follows the elastic (principal) stress distribution was used in the present study for the test specimens (Breña and Morrison, 2007). As shown in Figure 1(b), solid and dashed lines indicate ties and struts in the model, respectively. The imposed load in the test specimen was transferred directly from the loading point to the right support through a bottle-shaped strut, but the opening near the lower left corner impairs the direct load transfer from the load point to the left support. This model also provided a platform to compare the experimental results with those available in the literature. Test specimens were designed for an ultimate load-carrying capacity of 31.3 kips computed as per ACI Committee 318 (2008) procedure for strut-and-tie models. The nominal compressive strength of concrete was assumed as 5000 psi, whereas the tensile strength of reinforcement bars was considered as 60000 psi. A strengthreduction factor (β s ) equal to 0.75 was used for struts and nodes in the strut-and-tie model. Reinforcing bars in the RC specimen was provided in two layers using No. 3 bars. Clear cover of concrete was provided as 1 in. to the edge of steel reinforcement. Bars ending at nodes located near the beam edges were hooked at their ends to avoid pullout. As shown in Figure 2(a), bottom longitudinal reinforcing bars were anchored at the supports using standard 180-degree hooks. Prior experimental study (Breña and

1984 Morrison, 2007; Flores, 2009) showed that these specimens suffered severe cracking and crushing of concrete near the supports. To avoid these premature local failures in the RC specimen, a steel cage formed by four longitudinal reinforcement bas at the corners and transverse stirrups at a spacing of 4 in. was used as boundary elements on either side of the RC specimen. Further, no wire meshes were used in the RC specimen. Figure 2(b) shows the reinforcement detailing of the SFRC specimens. As stated earlier, two No. 3 steel reinforcing bars were used only for bottom longitudinal tensile reinforcement. Similar to the RC specimen, steel cages were used as boundary elements near the left and right supports of the specimen. Further, two additional No. 6 bars were placed diagonally (normal to the line connecting the loading point to the corner of opening) in two layers just above the opening so as to restrain the propagation of cracks emanated from the corner of the opening. (a) (b) Figure 2. Reinforcement detailing in test specimens (a) RC (b) SFRC A concrete mixture with a nominal 28-day compressive strength equal to 5000 psi was used in all specimens. No chemical admixtures or super-plasticizers were added in the concrete mix. The mix design was carried out for the target compressive strength of concrete so that the optimum quantity and similar proportions of materials could be used in both RC and SFRC specimens. The design mix proportion (by weight) used for both specimens was 1.0 (cement): 0.5 (Fly ash): 1.7 (fine aggregate): 1.0 (coarse aggregate). Type-1 portland cement and Class-C fly ash were used in the mix. The maximum size of coarse aggregate used in the concrete mix was limited to 0.5 in. A constant water-to-cementitious materials ratio of 0.4 was used for both specimens. SFRC specimen consisted of end-hooked steel fibers (diameter = 0.03 in.; length = 2.4 in.; aspect ratio = 80; tensile strength = 150 ksi) of volume equal to 1.5% of the total volume of the specimen. The total weight of steel fibers was 89 pounds as compared to the cement weight of 360 pounds used in the SFRC specimen.

1985 Standard tests (ASTM C31 and C39; ACI 318 Sect. 5.6.2.4) were carried out to evaluate the compressive strength of concrete (six 4 in. by 8 in. cylinders) and the tensile strength of steel reinforcement bars. The nominal and actual properties of concrete and steel reinforcement bars are compared in Table 1. The average values of compressive strengths of concrete at the day of testing of the RC and the SFRC specimens were 6.7 ksi and 6.3 ksi, respectively. The actual yield strength of No. 3 steel reinforcement bars was 81.2 ksi against their nominal value of 60 ksi. Moreover, the ultimate tensile strength of steel reinforcement bars was found to be 126.7 ksi. Tensile testing of No. 6 bars were not carried out because they were designed to be remain elastic. However the state of strain in No. 6 bars was monitored by strain gauges during the tests. Table 1: Nominal and measured material properties Specimen Concrete compressive strength (ksi) Tensile strength of No. 3 bars (ksi) 28-days nominal Measured at the day strength of testing RC 6.7 5.0 SFRC 6.3 TEST SET-UP AND INSTRUMENTATION Measured yield stress Measured ultimate stress 81.2 126.7 Both RC and SFRC specimens were subjected to gradually increased monotonic loading by using a universal testing machine of 400 kips capacity. The loading magnitude was increased at an interval of 5 kips until the load-carrying capacity of specimens reduced significantly. As shown in Figures 1(a) and 3(a), a 2-in. diameter steel roller was placed between two 1-in. thick steel plates at the supports to avoid local crushing of the concrete due to bearing. Horizontal restraints were applied to the roller at one support to simulate the hinge support condition, whereas the roller at the other support was free to move in both ways to prevent the possible confinement pressure to the supports. 150 Load (kips) 100 50 SFRC RC Design strength (a) (b) Figure 3. (a) Test set-up used in the present study (b) Comparison of loaddisplacement response of test specimens 0 0.0 0.2 0.4 0.6 0.8 1.0 Displacement (in)

1986 Extensive instruments were used to measure the response of test specimens at different load levels. A 600-kip capacity load cell was used at the load point to monitor the magnitude of load applied to the specimens. Uniaxial strain-gauges (resistance = 120 ohms; gauge length = 0.2 in.) were bonded to the surface of steel reinforcements at specified locations to measure the tie forces at various load levels. As shown in Figure 1(a), four linear variable differential transformers (LVDTs) were mounted on the surface of test specimens to measure the deformation of concrete struts during the testing. Also, a linear potentiometer was used exactly below the load point to measure the deflection of test specimens and two additional linear potentiometers were also used to monitor the movement of both supports. TEST RESULTS The behavior of test specimens under the action of monotonic loading was monitored at various stages of loading. The primary parameters investigated in the present study are load versus deflection response, mode of failure and ultimate strengths of specimens as discussed in the following sections. Load-Deflection Response The deflection of the specimens just below the loading point was monitored at the different stages of loading. The load-deflection behavior of the RC specimen is shown in Figure 3(b). The RC specimen showed almost linear response up to 95 kips beyond which yield plateau and strain-hardening was observed up to peak load of 132.1 kips in the load-deflection response. The design load-carrying capacity of the specimen was 31.3 kips, which was estimated by using the strut-and-tie model. Thus, the RC specimen was over-designed by a factor of 4.2. The excellent post-yield behavior of the RC specimen suggested that the bottom longitudinal reinforcement bars were yielded in tension. This was also confirmed from the state of strains in these steel reinforcement measured using uniaxial strain gauges. The delaying of premature local failures of the specimen near the supports due to steel cages at the boundaries helped the RC specimen to exhibit excellent displacement ductility of nearly 4.0. As expected, the descending branch of the load-deflection response of the RC specimen exhibited by the sudden drop from its peak strength. Figure 3(b) also shows the load-deflection behavior of the SFRC specimen. The SFRC specimen showed nearly a linear response up to a peak load of 96.8 kips, which was much higher than the design load of 31.3 kips that used for the RC specimen. It should be noted that even though there were absolutely no steel reinforcement bars used as struts and ties as per strut-and-tie models, the SFRC specimen reached 3.0 times the design load. Further, the SFRC specimen showed more gradual post-peak descending branch in the load-displacement response in contrast to a sudden drop in case of the RC specimen indicating significant contribution of steel fibers to the residual strength of the specimen. The boundary elements in addition to diagonal steel reinforcement bars helped the specimen to

1987 achieve the design strength without premature local crushing and cracking of concrete at the boundaries. Mode of failure Figure 4(a) shows the observed crack pattern in the RC specimen. As expected, the local failure at the supports of the RC specimen was not observed during the entire loading because of sufficient confinement action proved by the steel cage to the compressive stresses. The major flexural crack running from the bottom face of the specimen to the loading point was observed at the failure stage. The specimen collapsed due to shear failure of concrete in the horizontal segment of the opening due to lack of shear reinforcement as shown in Figure 4(b). This ultimately led to the fracture of bottom longitudinal tensile reinforcing bars after reaching their failure strains. It is interesting to note that the major cracks were developed away from the opening region indicating that the flow of force was least affected by the opening due to local strengthening of the boundaries near supports. (a) (b) Figure 4. Mode of failure of the RC specimen (a) Overall state of specimen at the failure stage (b) Shear failure of concrete in bottom segment of the opening Plastic Hinges (a) (b) Figure 5. Failure mode of the SFRC specimen (a) Specimen at the failure stage (b) Failure of horizontal segment of the opening

1988 As shown in Figure 5(a), the failure mode of the SFRC specimen was completely different from that of the RC specimen. A major crack (compressive strut) was developed just above the opening of the SFRC specimen. Due to presence of diagonal steel reinforcement bar, the major crack deviated from the corner of the opening and formed at the end of this bar. A plastic mechanism was developed after several plastic hinges formed at the specimens (Figures 5(a) and 5(b)). The failure was fairly ductile as evidenced by the large deformation of the specimen shown in Figure 5 (a). Ultimate strength As stated earlier, the design strength of test specimens was 31.3 kips. The specimen was analyzed by a strut-and-tie computer program, CAST (Tjhin and Kuchma, 2002). This program has a feature that allows the analysis of nodes to ensure that geometry and stress limits are not exceeded. Using nominal (specified) values of material strength and assuming a strength reduction factor as 0.75, the nominal ultimate strength of the RC specimen was estimated to be 41.2 kips. The expected actual capacity of the specimens was 70.3 kips considering the actual material properties obtained from coupon testing of concrete and steel bars and the strength-reduction factor as unity. The ultimate strength of the RC specimen was observed as 132.1 kips which was 1.9 times the expected strength predicted by the computer model. The main reason for the large difference between measured and predicted strengths is the redistribution of stress in the specimen after the yielding of steel bars acting as tie members. Similarly, the SFRC specimen had ultimate strength of 96.8 kips which was about 1.4 times the predicted ultimate strength of the RC frame. It should be noted that the ultimate strength of the SFRC specimen was higher than the predicted ultimate strength (70.3 kips) of the RC specimen even though no steel reinforcement bars were used as tie members. Further, the fiber bridging effects limited the widening of cracks and allowed significant stress redistribution and a plastic mechanism formation upon failure. SUMMARY & CONCLUSIONS This paper investigates the behavior of deep beams with large opening that were designed using strut-and-tie model. One reinforced concrete (RC) and one steel fiber reinforced concrete (SFRC) specimens were tested under monotonically-increased loading. The main objectives of this paper were: (a) to investigate the effect of local strengthening on load-transferring mechanism and failure modes of test specimens; (b) to study the behavior of SFRC specimen and compare with the RC specimens designed using strut-and-tie models; and (c) to identify critical regions that are not identified by strut-and-tie models and to suggest reinforcing detailing to avoid localized failures. The following conclusions were drawn in this present study:

1989 1. Design strut-and-tie models significantly underestimated the strength of specimens. RC specimen showed the load-carrying capacity greater than four times of the nominal strength predicted using the design strut-and-tie model. 2. SFRC specimen reached the three times of design strength of RC specimen even though steel reinforcement bars were not used as tie members except only bottom longitudinal tensile bars. 3. Local strengthening of test specimens using steel cage at the supports significantly enhanced load-carrying capacity and changed the mode of failure to a much ductile manner. As a consequence, significant bending (flexural) action was noticed in the RC specimen without any premature local failures. 4. Steel fibers in the SFRC specimen restrained the widening of crack growth and increased the number of cracks. This helped in better stress redistribution in the specimen even if the steel reinforcement bars were not present. A ductile plastic mechanism was developed after the formation of plastic hinges. Further research is needed to investigate the effects of volume fraction of steel fibers on strength of members designed as per strut-and-tie method. 5. The construction of RC specimen was usually time-consuming and laborintensive due to complicated detailing of reinforcing bars in contrast to the SFRC specimen. Hence, the complete replacement of conventional reinforcing bars by deformed steel fibers at a volume of 1.5% can be a feasible alternative to the current practice. REFERENCES ACI Committee 318 (2008), Building Code Requirements for Structural Concrete (ACI 318-08) and Commentary (ACI 318-08), American Concrete Institute, Farmington Hills, Mich. ACI Committee 544 (1996), Report on Fiber Reinforced Concrete (ACI 544.1 R-96), American Concrete Institute, Farmington Hills, Mich. Breña, S. F,; and Morrison, M. C. (2007), Factors Affecting Strength of Elements Designed Using Strut-and-Tie Models, ACI Structural J., American Concrete Institute, 104(3), 267-277. Flores, C. A. (2009), Performance of large scale steel fiber reinforced concrete deep beam with single opening under monotonic loading, M. E. Thesis, Department of Civil Engineering, University of Texas at Arlington, USA Chen, B. S., Hagenberger, M. J., and Breen, J. E. (2002), Evaluation of Strut-and- Tie Modeling Applied to Dapped Beam with Opening, ACI Structural J., American Concrete Institute, 99(4), 445-450. Dupont, D., and Vandewalle, L. (2003), Shear Capacity of Concrete Beams Containing Longitudinal Reinforcement and Steel Fibers, Ed. Banthia, N.; Criswell, M.; Tatnall, P.; and Folliard, K., Innovations in Fiber-Reinforced Concrete for Value, American Concrete Institute, Farmington Hills, Mich.

1990 Kuchma, D., and Park, J. W. (2007), Strut-and-Tie Model Analysis for Strength Prediction of Deep Beams, ACI Structural J., American Concrete Institute, 104(6), 657-666. Kuchma, D., Yindeesuk, S., Nagle, T., Hart, J., Lee, H. H. (2008), Experimental Validation of Strut-and-Tie Method for complex Regions, ACI Structural J., American Concrete Institute, 105(5), 578-589. Mansur, M. A., and Ong, K. C. G. (1991), Behavior of Reinforced Fiber Concrete Deep Beams in Shear, ACI Structural J., American Concrete Institute, 88(1), 98-105. Maxwell, B. S., and Breen, J. E. (2000), Experimental Evaluation of Strut-and-Tie Model Applied to Deep Beam with Opening, ACI Structural J., American Concrete Institute, 97(1), 142-148. Narayanan, R., and Darwish, I. Y. S. (1988), Fiber Concrete Deep Beams in Shear, ACI Structural J., 85(2), 141-149. Schlaich, J., Schäfer K., and Jennewein, M. (1987), Toward a Consistent Design of Structural Concrete, PCI J., Precast Prestressed Concrete Institute, 32(3), 74-150. Tan, K. H., and Zhang, N. (2007), Size effect in RC deep beams: Experimental investigation and STM verification, Engineering Structures, 29, 3241-3254. Tjhin, T. N., and Kuchma, D. A. (2002), Computer-Based Tools for Design by Strutand-Tie Method: Advances and Challenges, ACI Structural J., American Concrete Institute, 99(5), 586-594.