Fresh air supply systems

Similar documents
Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

sound reduction systems for commercial, educational and industrial environments

Installation, operation and maintenance manual TX 35A

- White Paper - Data Centre Cooling. Best Practice

SKER HUESKER HUESKER HUESKER HUESKER HUESKERHUES SKER HUESKER HUESKER HUESKER HUESKER HUESKERHUES SKER HUESKER HUESKER HUESKER HUESKER HUESKERHUES

DIGITUS Network & Server Cabinets. UNIQUE Series

SERVER ROOM CABINET INSTALLATION CONCEPTS

19" Data Racks. Adjustable feet To compensate for uneven floors and assure great stability all feet can be up to 20 mm adjusted.

PLUG and PLAY VRV Connection

ORAY PREFABRICATED GSM SHELTER CONTAINERS TECHNICAL SPECIFICATIONS

AMF Line; wall absorbers Wall mounted acoustic designs PERFORMANCE CEILINGS. M ore s c op e f or i n n ovat i on MADE IN GERMANY

Accessory Manual Ventilation Section Model Comfort Circle

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

39HQ Airovision Air Handling Units

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Under sill units. Type FSL-B-ZAS

HALE PET DOOR INSTALLATION INSTRUCTIONS HALE STANDARD PANEL MODEL

RPV - RP - RA air handling units

Handbook for Basement

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Variety of Control Options Control is possible via wall switches, remote control systems or integration into building management systems.

TPM 006/99 Revision 1 VALID FROM: 8/2/2013 REPLACEMENT FOR TPM 006/99 FIRE SHUTTER

HDA

HERZ-Thermal Actuators

Integral Kit Instructions

Material test chamber with mechanical convection

Installation Instructions

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

AND MEMBRANES ROOFING UNDERLAYS.

Asphalt Shingle Application Requirements

Terminal Boxes Series 8146

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Recirculating Roof Fans Models ESRMD, ESRMDF and ERD

Incubator with mechanical convection

Combi Unit Genius. The energy efficient Building Service Centre

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

Installation Instructions For Slider Casement Air Conditioners

Mistrale. Fusion Terminal

SECTION MORTUARY REFRIGERATORS

TFSR & TFSK Roof Fans

Laminar Flow Panel. Type LFP 2/2.4/B/2. Telephone +44(0) Telefax +44(0)

Cabinets 101: Configuring A Network Or Server Cabinet

plumbing products guide

INSTALLATION INSTRUCTIONS AIRCOMMAND IBIS ROOFTOP AIRCONDITIONER

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Planning Information. Passenger and Freight Elevators.

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

Solar Hot Water Heaters

Filter Fan Unit SILENT. Type SILENT AC Type SILENT EC

ModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

ModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

Make Your Own SNOWBREEZE AC For Rs.1500 ($30) Can be converted into an energy saving and humidified room heater in winter

Installation guide for the SafeLine type anchorage device. Tested in compliance with EN 795: No.: SE-...

Grilles & Diffusers Series LFP Incorporating

HORIZONTAL INSTALLATION

The best invention since pig equipment.

EH-20 20m antenna. By VE3RGW

Pipe Clamps and Accessories

york air-conditioning products Residential & VRF News 2015

Coldrooms designed for your application

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Now available with full IP65 rating: Protection from dust and water jets NEW: K470 Plus covered containers

Heating oven with mechanical convection

AMPSEAL* Automotive Plug Connector and Header Assembly

WALLS Three common wall types are described below, with their insulation solutions.

Flue Installation. High Efficiency Condensing Boilers

SunMor SM-V30 Solar Water Heater Installation Manual

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

DIGITAL WARMING CABINETS

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Knürr Miracel. Knürr Miracel. 19 Network and Server Rack Platform 1.12 to

DEHN + SÖHNE. DEHNconductor System No Problems with Proximities

1 DESCRIPTION OF THE APPLIANCE

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Aluminium Standard. Technical Data. Included in delivery

Floor Heating Warehouse.co.uk

Portable Air Conditioner

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Focus on Building Louvres. Sun shading & comfort ventilation.

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

UDSA - UDSBD unit heater

Product Information 19 / 45HU Data-Center-Rack (Cabinet)

Portable digital microprocessor thermometers with interchangeable probes

Heating and cooling. Insulation. Quick facts on insulation:

Safety along the complete line: SIRIUS 3SE7 cable-operated switches. sirius COMMANDING & SIGNALING

Answers to Your Questions from the Webinar

LockerLock Schließgehäuse LockerLock lock case Boîtier de fermeture LockerLock Scatola di ciusura LockerLock Caja de cierre LockerLock

I. Introduction 02. Specifications 02 Accessories 02 Features 03. II. Installation Instructions 06

STEEL BUILDINGS IN EUROPE. Single-Storey Steel Buildings Part 8: Building Envelope

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Transcription:

Fresh air supply systems Optimum fresh air supply for every type of pig house

Fresh air supply systems the right solution for every type of pig house! Big Dutchman offers a wide range of fresh air supply systems to ensure optimal provision of fresh air. Depending on structural conditions and special requirements high-velocity ventilation, diffuse air, negative or balanced pressure the following systems can be implemented: 4 fresh air inlets for installation into the wall or ceiling; 4 perforated air channel and DiffAir ceiling; 4 fresh air chimneys. Let our experts advise you on how to find the best solution for your individual requirements. FRESH AIR INLETS FOR STABLE HIGH-VELOCITY VENTILATION CL 1200, CL 1211 F, CL 1200 B/F, CL 1911 F, ZEW Polar Fresh air inlets for wall installation The wall inlets of the CL series are made of shock-proof, recyclable, non-deformable, UV-stabilised plastic and can easily be cleaned with a high-pressure cleaner. The insulated inlet flap is kept in a closed position by rustproof steel springs, thus sealing the building airtight. The inlet flap is pulled open. This allows the farmer to regulate the inlet opening very precisely in each season. As an example from the winter season: the cold, outside air enters the building, immediately combining with the warm, inside air. This process helps create a more comfortable climate for the animals and can easily be managed with a control set. This control set opens the fresh air inlets either all at once or individually. CL 1200 multi-purpose wall inlet CL 1211 F flange inlet for sandwich panels CL 1200 B/F economical flange inlet Due to the patented advanced inlet control (AIC), a single action at each inlet pre-defines which inlets open first and which open later. If the number of opened inlets is reduced, especially during the cold season or while heating is necessary, the remaining inlets can be opened further, which makes for a more stable airflow. CL 1911 F flange inlet for sandwich panels, with high air rate The ZEW Polar 1300 wall inlet is made of polyurethane rigid foam a very stable material with good insulating properties. The inlet can be easily cleaned with a high-pressure cleaner. The inlet flap of the ZEW Polar 1300 stays in line with its frame when open. Thanks to this special feature, the cold fresh air and the warm, humid house air only meet in areas outside the inlet. The flap therefore opens and closes reliably, even at very low temperatures, and less ice forms. ZEW Polar 1300 wall inlet for cold regions

CL 1540 and ZED 5000 Fresh air inlets for the ceiling and combi-diffuse ventilation CL 1540 multi-purpose ceiling inlet The CL 1540 is a multi-purpose ceiling inlet. The materials of this inlet are made of recyclable, shock-proof, non-deformable and UV-stabilised plastic. Rustproof steel springs keep the insulated inlet flap closed. The inlet flap opens in a downward motion, helping create a forward-moving airflow in the direction the flap is facing. The air always flows along the ceiling, whether the inlet is opened fully or only sightly. This is done to avoid draughts in the animal area. The corresponding control set opens the ceiling inlets either at once or individually. If a ceiling has a thickness of more than 110 mm (for example, if mineral wool is used) and/or to enhance the performance of the ceiling inlets, an optional intake funnel is available. The 1540, specifically, can be used for fresh air supply from the attic or for combi-diffuse ventilation. ZED 5000 with extension ceiling inlet with high air rate The ZED 5000 inlet is made of polyurethane and is equipped with a flange so it can be fastened to the ceiling. This inlet can produce very high air rates and is therefore especially well suited for additional summer ventilation when combined with a DiffAir ceiling (combidiffuse ventilation). Another area of application is the socalled aisle ventilation for which the ceiling inlets are installed above the feed aisle. This ensures that fresh air is directed into the feed aisle. Central aisle placement of the ZED 5000 brings fresh air into the aisle Combi-diffuse ventilation is a combination of two ventilation systems. In case of low outside temperatures, fresh air is supplied by means of the DiffAir ceiling. This allows the air to flow very evenly and at a low speed along the ceiling. In case of high outside temperatures, ceiling inlets are automatically opened by the 135pro or 235pro climate computer. This effect causes the air to enter the pen at a much higher speed. The animals then feel much more comfortable with the perceived lower temperatures created with higher air speeds, and productivity increases. Air performance in m 3 /h of wall and ceiling inlets when fully opened Model CL 1211 F CL 1200 B/F CL 1220 CL1224 CL 1229 CL 1233 CL 1911 F ZEW Polar 1300 Code no. 60-44-3111 60-43-3009 60-44-3140 60-44-3144 60-44-3149 60-44-3153 60-43-4011 60-47-3791-10 Pa 1 000 1 000 1 200 1 250 1 280 1 350 1 750 1 300-20 Pa 1 450 1 450 1 700 1 750 1 800 1 940 2 500 2 000-30 Pa 1 700 1 700 2 050 2 120 2 170 2 300 3 050 2 400 Model CL 1540 ZED 5000 o.a. with extension ZED 5000 c.a. Code no. 46-70-0717 60-47-3364 83-09-5830 60-47-3365-10 Pa 1 250 1 450* 3 640 4 000 3 640-20 Pa 1 750 2 100* 5 480 5 800 5 480-30 Pa 2 100 2 550* 6 530 7 200 6 530 * with intake funnel, code no. 60-40-1323 (standard) and 60-40-1324 (long); o.a. opens automatically, c.a. closes automatically

Useful accessories to help you Net protection against birds The CL 1200 series has a self-supporting plastic net which is fastened to the inlet from the outside by means of a simple locking system. Air deflector The air deflector is mounted at the upper edge of the inlet and enables precise distribution of the incoming airflow, especially in cold weather. The direction of the airflow can be adjusted individually for each building by changing the angle between the deflector and the wall. Spacer Spacers are used when tension rods have to be guided around posts along the house wall. The maximum distance to the wall is 24 cm (one spacer per inlet). Dimensions and installation of wall and ceiling inlets The installation height of the wall inlets depends on the type of building and production method, and has to be planned individually for each project. The wall and ceiling inlets are designed to provide customised air rates for individual requirements. CL 1200 615 CL 1211 and CL 1200 B/F *570 555 7,5 o 325 190 1220 122 230 CL1224 280 CL1229 320 CL1233 *280 265 550 7.5 o 325 110 122 300 Net 260 40 588 600 * with extension CL 1911 F *850 840 ZEW Polar 1300 560 835 265 270 *285 7,5 o 7,5 o 325 110 40 122 300 190 1220 122 230 CL1224 280 CL 1229 320 CL 1233 300 885 * with extension 588 CL 1540 583 ZED 5000 575 352 110 644 583 64 357 569 110 140 1261 1131 30 20 350 316 260 1170 438 All dimensions in mm

DIFFUSE FRESH AIR SUPPLY SYSTEMS Perforated air channel A universal method for supplying fresh air Due to their modular design, perforated air channels are suitable for nearly every house type with an inserted ceiling below the attic. They are available in five different widths and consist of heat-insulated polyurethane (PU) plates. The individual hole pattern of the perforated plate ensures optimum fresh air ventilation throughout the house. Furthermore, this system guarantees an ideal adaptation to maximum summer air temperatures or conditions. The PU plates can also be used as partially or completely perforated ventilation ceilings. Air distributed by a perforated air channel in the ceiling of a dry sow house with ESF system DiffAir ceiling Fresh air provided throughout the entire ceiling DiffAir ceilings consist of glassreinforced plastic (GRP) trapezoidal or aluminium sheets. Aluminium sheets have the advantage of being incombustible. DiffAir ceilings are installed at a height of 2.40 to 3 m. They serve both as a diffuse air supply system and economical ceiling insulation, consisting of specially treated glass wool. Two layers of the glass wool are provided, permeable to airflow. An additional layer of fleece between the glass wool and the DiffAir plate acts as a water repellent. Fresh air enters uniformly along the entire ceiling for an even distribution while ensuring the maximum permitted air speed in the animal area. DiffAir plate made of aluminium Structure of a DiffAir ceiling DiffAir ceiling in combination with the CL 600 exhaust air chimney Technical data DiffAir plate made of GRP DiffAir plate made of aluminium Standard dimensions: 5.10 m x 1.05 m 5.10 m x 1.05 m (customised lengths upon request) (customised lengths upon request) Plate thickness: 0.9 mm or 1.5 mm 0.35 mm Weight: approx. 3 kg/m 2 (incl. glass wool) approx. 2.7 kg/m 2 (incl. glass wool) Perforation: approx. 7 % approx. 7 % Insulating material: 2 glass wool layers of 4 cm each and glass fibre non-woven Fastening material: Plumber sealing screws V2A; 4.5 x 35 mm Max. span: 1.20 m for a plate thickness of 0.9 mm 1.20 m for a plate thickness of 0.35 mm 2.40 m for a plate thickness of 1.5 mm

FRESH AIR CHIMNEY FOR NEGATIVE- AND BALANCED-PRESSURE VENTILATION FAC 2 (Fresh Air Chimney) Supplying fresh air directly from the roof The FAC 2 fresh air chimney draws fresh air from the rooftop and distributes it evenly throughout the barn. The stable pipe system is GRP coated on both the inside and the outside, and is insulated with 30 mm of polyurethane. This gives the chimney a long service life and makes cleaning easier. FAC 2 is available in four diameters (650, 730, 820 and 920 mm). The fresh air distributor at the lower end of the chimney ensures that the entering air is distributed evenly inside the house. This creates a stable airflow even with minimum ventilation. FAC 2 is available with central or individual control. For individual control, the actuator is installed directly in the chimney. Central control of multiple chimneys is carried out with only one actuator via cables and tension rods. As pigs are very sensitive to draughts, a recirculation unit including a fan is a standard feature of FAC 2. This unit distributes cold incoming air more evenly in the house, especially in winter. As an option, FAC 2 can be equipped with a fan inside the chimney. This fan pushes the fresh air drawn in by the chimney through the fresh air distributor and into the house to create a balanced pressure system. FAC 2 is especially suitable where 4 fresh air distribution along the side walls or an inserted ceiling is not possible or not wanted; 4 the barn is extremely wide and very low so that good air circulation with only wall inlets is not feasible; 4 a balanced-pressure ventilation should be used, e.g. to compensate for air leakages in the building. FAC 2 with actuator for individual control FAC 2 with wire mesh guard and recirculation unit with fan for even distribution of the fresh air Air performance in m 3 /h of FAC 2 when fully opened Pa / Ø 650 mm 730 mm 820 mm 920 mm -10 Pa 4 900 6 100 6 700 9 500-20 Pa 7 000 8 900 11 000 13 700-30 Pa 8 600 11 000 13 500 16 900 Balanced pressure: 13 600 17 900 24 700 24 600 The recirculation fan creates a mixture of fresh air and warm house air. A temperature sensor installed in one of the fresh air chimneys allows the recirculation fans to switch on or off at a specific temperature. Germany: Big Dutchman Pig Equipment GmbH Postfach 1163 49360 Vechta Tel. +49(0)4447 801-0 Fax -237 big@bigdutchman.de www.bigdutchman.de USA: Big Dutchman, Inc. Tel. +1 616 392 5981 bigd@bigdutchmanusa.com www.bigdutchmanusa.com Brazil: Big Dutchman (Brasil) Ltda. Tel. +55 54 2101 5900 bigdutchmanbrasil@bigdutchman.com.br www.bigdutchman.com.br Russia: OOO Big Dutchman Tel. +7 495 2295 171 ikotov@bigdutchman.ru www.bigdutchman.ru Asia/Pacific: BD Agriculture (Thailand) Ltd. Tel. +66 2 349 6531 info@bigdutchman.com www.bigdutchman.com China: Big Dutchman (Tianjin) Livestock Equipment Co., Ltd. Tel. +86 10 6476 1888 bdcnsales@bigdutchman.com www.bigdutchman.org.cn Technical details subject to change. en 10/2015