Agilent Technologies B4610A Data Import Tool for Offline Viewing and Analysis

Similar documents
Agilent Automotive Power Window Regulator Testing. Application Note

Agilent U2000 Series USB Power Sensors

The Next Generation in Automated Oscilloscope Test

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

PCI Express 1.0 (2.5 GT/s) Protocol Test

Agilent U2000 Series USB Power Sensors

Agilent Technologies. Troubleshooting Three-Phase AC Motors with U1210 Series Handheld Clamp Meters. Application Note

Agilent E6832A W-CDMA Calibration Application

Agilent Television Power Consumption Testing. Application Note

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent 87421A/87422A Power Supply

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Agilent N5970A Interactive Functional Test Software: Installation and Getting Started

Agilent MATLAB Data Analysis Software Packages for Agilent Oscilloscopes

High-Speed Inter Connect (HSIC) Solution

Agilent 4338B Milliohm Meter

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Installation Guide E Dielectric Probe Kit 85071E Materials Measurement Software

U7248A High Speed Inter-Chip (HSIC) Electrical Test Software Infiniium Oscilloscopes

DDR Memory Overview, Development Cycle, and Challenges

802.11ac Power Measurement and Timing Analysis

Agilent Mobile WiMAX R&D Test Set Solutions: Software and Technical Support Contract

81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

What is the difference between an equivalent time sampling oscilloscope and a real-time oscilloscope?

Keysight Technologies N1918A Power Analysis Manager and U2000 Series USB Power Sensors. Demo Guide

Building Hybrid Test Systems, Part 1

Agilent U2000 Series USB Power Sensors

Agilent E5063A ENA Series Network Analyzer

Application Note. Double click System tray icon after service started. Click start/continue button

Think SAFETY When Selecting a Handheld Multimeter

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

Agilent 4339B/4349B High Resistance Meters

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

PXI and AXIe Modular Instrumentation

Agilent Infoline Web Services. Quick Reference Guide. Scan and use your phone to go to Infoline at

Updating the QIAcube operating software

Agilent FieldFox Remote Viewer

Time-Correlated Multi-domain RF Analysis with the MSO70000 Series Oscilloscope and SignalVu Software

Keysight Technologies Connecting Data Acquisition Systems to a Wireless Network

Testing WiMAX receiver performance in a multipath propagation environment using Agilent s E6651A with an EB Propsim C8 radio channel emulator

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

PXI and AXIe Modular Instrumentation

Keysight Technologies The Advantages Of Remote Labs In Engineering Education

Release Notes: PowerChute plus for Windows 95 and Windows 98

Agilent EEsof EDA.

Evaluating Oscilloscope Bandwidths for Your Application

Agilent OSS Wireless QoS Manager

Variable Frequency Drive Troubleshooting with U1610A/U1620A

AT-S39 Version 1.3 Management Software for the AT-8024 and AT-8024GB Fast Ethernet Switches. Software Release Notes

Using an Agilent InfiniiVision Series MSO To Debug an Automotive CAN Bus

Quantum View Manage Administration Guide

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

Agilent EEsof EDA.

Image Lab Software for the GS-900 Densitometer

PANDUIT Physical Layer Infrastructure Management. EMC Smarts Integration Module

Agilent VEE Pro Data Sheet

Making Basic Measurements. Publication Number August Training Kit for the Agilent Technologies Series Logic Analysis System

WD Sentinel DX4000. Small Office Storage Server. Administrator s Quick Install Guide

Free 15-day trial. Signata Waveform Viewer Datasheet

IFS ApplIcAtIonS For Document management

Make Better RMS Measurements with Your DMM

Agilent IMS-SIP Network Emulator Software (E6966A)

Keysight E2688A, N5384A High-Speed Serial Data Analysis and Clock Recovery Software

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

PRODUCT DATA. PULSE WorkFlow Manager Type 7756

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

Project Manager Editor & Debugger

Keysight N6854A Geolocation System. Configuration Guide

AN4108 Application note

Integrating CaliberRM with Software Configuration Management Tools

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

Quantum View SM Manage Administration Guide

How does a venture capitalist appraise investment opportunities?

Report on Government Information Requests

Supplies 1. Toner cartridges. Printing. Using color. Paper handling. Maintenance. Troubleshooting. Administration. Index

NetFlow Feature Acceleration

The Real Total Cost of Ownership of Your Test Equipment

Agilent P940xA/C Solid State PIN Diode Switches

Configuring DHCP for ShoreTel IP Phones

Image Lab Software How to Obtain Stain-Free Gel and Blot Images. Instructions

Microsoft Voucher Ordering Processes

We decided that we would build IFS Applications on standards so our customers would not be locked into any particular technology. We still do.

Creating Datalogging Applications in Microsoft Excel

Dash 18X / Dash 18 Data Acquisition Recorder

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Achieving Functional Safety with Global Resources and Market Reach

CISCO IP PHONE SERVICES SOFTWARE DEVELOPMENT KIT (SDK)

Agilent Technologies N5393B PCI Express 2.0 (Gen2) Electrical Performance Validation and Compliance Software for Infiniium Oscilloscopes

CISCO CONTENT SWITCHING MODULE SOFTWARE VERSION 4.1(1) FOR THE CISCO CATALYST 6500 SERIES SWITCH AND CISCO 7600 SERIES ROUTER

Agilent Test Solutions for Multiport and Balanced Devices

TekSmartLab TBX3000A, TSL3000B Datasheet

Theatres/Channels All theatres. Indirect channel. Author/Owner

N6171A MATLAB Data Analysis Software for Agilent Instruments

NI USB-6008/6009 OEM USER GUIDE

Agilent Compatibility of the U2000 Series USB Power Sensors with Agilent Instruments. Application Note

AN2146 APPLICATION NOTE

MANUFACTURING DATA MANAGEMENT FOR MASTERCAM

Dash 8Xe / Dash 8X Data Acquisition Recorder

Transcription:

Agilent Technologies B4610A Data Import Tool for Offline Viewing and Analysis Data sheet Increase your team s productivity and equipment usage View and analyze acquired data when the oscilloscope or logic analyzer that acquired it is no longer available Share the entire data capture with local and geographically dispersed team members Gain instant insight into your target s operation and quickly identify the root cause of your debug problems with multiple analysis and viewing tools Enable others to make additional measurements with the acquisition hardware Take advantage of an efficient method for data storage, retrieval and sharing The B4610A data import tool lets you view and analyze data from Agilent 16900, 16800, 1680 and 1690 Series logic analyzers Agilent InfiniiVision 5000, 6000, and 7000 Series oscilloscopes Data files created in a compatible CSV format from EDA or other tools.

A quick tour of the application Once you receive the B4610A data import tool, you can install the free offline viewer on a PC and quickly view and analyze your saved data in just a few simple steps. Thereafter, simply import new data files for viewing. This example goes through the steps for importing data captured from an Agilent InfiniiVision MSO 7000 Series oscilloscope into the offline viewer. Figure 1. The B4610A data import tool can be used with all InfiniiVision scopes, including the 7000 Series, for advanced offline analysis Step 1. Install the free offline viewer software on your PC and enable the B4610A license The B4610A is shipped with a CD that includes the free offline viewer software. You can also download the free viewer from www.agilent.com/find/la-sw-download Follow the instructions on your entitlement certificate to redeem and enable the purchased B4610A license. 2

Step 2. Acquire, save and transfer the data via a USB drive to the PC with the offline viewer For this oscilloscope example, the B4610A data import tool enables you to import InfiniiVision 5000, 6000, or 7000 Series DSO/MSO oscilloscope data that you save to a thumb drive in.alb format. 1 Acquire a trace with your InfiniiVision DSO/MSO oscilloscope 2 Save the data in the ALB format Insert a USB thumb drive into a USB port of the oscilloscope Press the Save/Recall key on the front panel of the scope Press Formats from the menu below the screen Select ALB data file from the format menu Press Save. This will save the file onto the USB drive you plugged into the scope. 3 Transfer the data from your oscilloscope via a USB drive to your PC to view and analyze the entire deepmemory record. Figure 2. Save acquired data from any InfiniiVision scope to a USB drive using.alb Format 3

Step 3. Start the offline viewer and import the acquired or created data for viewing and analysis. To start the off line viewer select start --> all programs --> Agilent logic analyzer --> Agilent logic analyzer 4

Figure 3. Select Import from the Offline Startup Options dialog Figure 4. Select the appropriate module file type for data import. Select "Module binary file" for InfiniiVision oscilloscopes Figure 5. Import the.alb file previously saved in step 2 Figure 6. Once the data is imported a new data import module is created on the overview tab 5

Gain rapid insight from display and analysis tools Once you have imported your data you can add disply and analysis tools to get rapid insight and solve problems. With the Waveform/Chart Display you can: Validate correct hardware operation by viewing timing relationships between multiple buses and signals, including analog and digital signals from an Agilent InfiniiVision oscilloscope. Group signals into an unlimited number of buses. Re-order signals/buses to group related signals or place signals of interest next to each other. Individually color and size the signals/buses to highlight and differentiate areas of interest. Figure 7. Simultaneously view time-correlated analog and digital waveforms on your PC screen View data in a format you understand binary, hex, decimal, ASCII, or user-defined symbols. Compare signals/buses directly with the Overlay feature. The ability to overlay waveforms can be useful when you are looking for problems concering the relationship between digital and analog signals. Graphically validate digitized signals to and from A/D converters by charting the values of a bus over time. Display a bus or signal using meaningful names (symbols) rather than numeric values. Figure 8. Chart mode for A/D or DSP design verification 6

Easily make measurements and mark areas of interest with time and voltage markers Track down tough problems and accurately place markers to make critical timing and voltage measurements. Designate the same point in time throughout every display with up to 1,024 timecorrelated markers. Mark and navigate to points of interest with individually colored, named and annotated markers. Make quick, precise measurements on digital signals with snap-to-edge marker placement. Receive instant feedback on the exact position of the display data relative to the entire trace. Track a symptom on one bus to its cause on another bus or signal using time-correlated global markers. Figure 9. Use markers to measure the time between the rising edge and falling edge on a signal of interest Quickly navigate through deep traces to find the data of interest Draw a box to zoom in and out to get just the view you want. Scroll rapidly through the measurement using the scroll bars. Traverse the trace quickly using beginning, trigger and end icons. Receive instant feedback on the exact position of the display data relative to the entire trace. 7

Find meaning in the most complex data with Find and Filter tools The Find tool allows you to quickly search for specific bus/ signal patterns in deep traces. Focus on just the information you need. Filter uninteresting data such as idle states from deep, complex acquisition traces. Perform multiple analysis scenarios without re-acquiring data when you re not sure what you're looking for. Gain quick insight into the frequency of an event. Scroll through the trace with the filter tool s color highlighting enabled. Figure 10. Gain quick insights into event frequency throughout a trace by using the color selection in the Filter tool. Advanced filtering capabilities of data record. Shown here is a data write value of D5 on My Bus 1 and voltage level range of 2 to 2.5 V. Save time performing your favorite analysis scenarios. Store, recall and share your favorite search/filter conditions, each individually named for easy recognition. Locate the next occurrence of a given event in the trace by simply drawing a box around the event of interest. The Filter tool lets you show or suppress events, based on criteria such as the cycle type or chip select. You can also display each type of event in a different color. 8

Other display and analysis tools Listing Packet viewer Source correlation VBA View Displays data patterns and sequences of events in the same order they were captured and placed into memory. Displays summarized and detailed packet information simultaneously within two panes. The window is automatically customized for the protocol family being decoded. The upper packet summary pane displays decoded packets and fields. The lower pane contains tabs for viewing selected packet details, header, payload, and lane information. Displays time-correlated source code and inverse assembly simultaneously in a split display. Requires access to source files via the LAN or instrument hard drive to provide source code correlation. Source correlation does not require any modification or recompilation of your source code. The VbaView window works with the integrated Microsoft Visual Basic for Applications (VBA) to provide custom data visualization charts. VBA View is a licensed feature that requires purchase of the B4606A advanced customization environment. The offline viewer also supports additional analysis tools for data captured with a logic analyzer. Refer to the 16800 (5989-5063EN) or 16900 Series logic analyzer (5989-0421EN) data sheets for more information. 9

B4610A characteristics When used with a logic analyzer or a file generated in a compatible CSV format Logic analyzer compatibility Supported data import file formats Supported saved file formats Data sharing Requires Agilent 16900, 16800, 1680, or 1690 Series logic analyzers with software version 3.70 or higher. The data import tool reads data from module CSV or module binary (ALB) files and makes it available to analysis tools and display windows. Module CSV or module binary (ALB) files can be: Created by external tools Created by instruments like Agilent 16900, 16800, 1680 or 1690 Series logic analyzers Saved from any logic analyzer module using the main menu's File>Export... command Data import modules (and import file names) are saved with logic analyzer configurations (both ALA and XML format). If a configuration is saved "with data" and then opened again, the import module's data is present, and is not re-read from the import file. If a configuration is saved "without data" (setup only) and opened again, the data import module file must re-read the import file Once the data has been imported using the B4610A and saved as a.ala file, the.ala file can be shared with any number of other users who have downloaded the offline viewer without the need for additional B4610A licenses. Agilent logic analyzer application software version 3.70 or higher. The software is included with the B4610A data import tool or it can be downloaded from www.agilent.com/find/la-sw-download When used with an InfiniiVision oscilloscope Oscilloscope compatibility Data import file format Supported saved file formats Data sharing Requires Agilent InfiniiVision 5000, 6000 and 7000 Series oscilloscopes with software version 5.0 or higher. InfiniiVision oscilloscopes create module binary (ALB) files compatible with the B4610A data import tool. The traces viewed are single-shot measurements. Data import modules (and import file names) are saved in an ALA configuration. If a.ala configuration is saved "with data" and then opened again, the import module's data is present, and is not re-read from the import file. If a configuration is saved "without data" (setup only) and opened again, the data import module with must re-read the import file Once the data has been imported using the B4610A and saved as a.ala file, the.ala file can be shared any number of other users who have downloaded the offline viewer without the need for additional B4610A licenses. Agilent logic analyzer application software version 3.70 or higher. The software is included with the B4610A data import tool or it can be downloaded from www.agilent.com/find/la-sw-download 10

Ordering information Ordering options for the Agilent B46104 data import tool The B4610A creates data import modules. Data import modules are a licensed feature. You can use data import modules without a license, but the amount of data that can be imported is limited to 16 rows (states). When ordering the B4610A you are required to select one of the following licensing options. B4610A-010 B4610A-020 Perpetual node-locked license B4610A-010 provides a perpetual node-locked license that is locked to a specific PC. The user can create an unlimited number of data import modules on the Overview tab. Each data import module can import a different.alb file. Includes entitlement certificate and CD with application software Perpetual server (floating) license The B4610A-020 provides a perpetual server (floating) license that is locked to a license server. The PC with the free offline viewer checks out a license from the license server. Each floating license enables the user to create a single data import module on the Overview tab. The data import module can import one.alb file at a time. Includes entitlement certificate and CD with application software For the most up-to-date and complete application and product information, please visit our web site at: www.agilent.com/find/logic-sw-apps or www.agilent.com/find/infiniivisionoffline Related literature Publication title Publication type Publication number Agilent 16900 Series Logic Analysis System Mainframes Data sheet 5989-0421EN Agilent 16800 Series Portable Logic Analyzers Data sheet 5989-5063EN Agilent InfiniiVision 7000 Series Oscilloscopes Data sheet 5989-7736EN Agilent InfiniiVision 6000 Series Oscilloscopes Data sheet 5989-2000EN Agilent InfiniiVision 5000 Series Portable Oscilloscopes Data sheet 5989-6110EN 11

www.agilent.com www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open Agilent Email Updates Agilent Direct www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of system-ready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. www.lxistandard.org LXI is the LAN-based successor to GPIB, providing faster, more efficient connectivity. Agilent is a founding member of the LXI consortium. Remove all doubt Our repair and calibration services will get your equipment back to you, performing like new, when promised. You will get full value out of your Agilent equipment throughout its lifetime. Your equipment will be serviced by Agilenttrained technicians using the latest factory calibration procedures, automated repair diagnostics and genuine parts. You will always have the utmost confidence in your measurements. Agilent offers a wide range of additional expert test and measurement services for your equipment, including initial start-up assistance, onsite education and training, as well as design, system integration, and project management. For more information on repair and calibration services, go to: www.agilent.com/find/removealldoubt For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Americas Canada (877) 894-4414 Latin America 305 269 7500 United States (800) 829-4444 Asia Pacific Australia 1 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 1 800 112 929 Japan 0120 (421) 345 Korea 080 769 0800 Malaysia 1 800 888 848 Singapore 1 800 375 8100 Taiwan 0800 047 866 Thailand 1 800 226 008 Europe & Middle East Austria 0820 87 44 11 Belgium 32 (0) 2 404 93 40 Denmark 45 70 13 15 15 Finland 358 (0) 10 855 2100 France 0825 010 700 Germany 01805 24 6333 Ireland 1890 924 204 Israel 972-3-9288-504/544 Italy 39 02 92 60 8484 Netherlands 31 (0) 20 547 2111 Spain 34 (91) 631 3300 Sweden 0200-88 22 55 Switzerland (French) 44 (21) 8113811 (Opt 2) Switzerland (German) 0800 80 53 53 (Opt 1) United Kingdom 44 (0) 118 9276201 Other European countries: www.agilent.com/find/contactus Revised: October 8, 2008 Product specifications and descriptions in this document subject to change without notice. www.agilent.com/find/logic_sw_apps www.agilent.com/find/infiniivision_offline Agilent Technologies, Inc. 2009 Printed in USA, February 9, 2009 5989-7834EN